FYRESIDE GAS FIREPLACE LOG SET

Similar documents
INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

NOTE! READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING.

AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM FOR NATURAL OR PROPANE GAS EPK-1 PILOT KITS

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

VENTED NATURAL GAS LOGS

GAS SAFETY PRECAUTIONS

San josé OWNER S MANUAL

Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: Natural Gas

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

HEATMASTER, LLC AMERICAN GAS LOG

orlando OWNER S MANUAL

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

INSTALLATION INSTRUCTIONS

SL280UHV SERIES GAS FURNACE WARNING

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

INSTALLATION AND OPERATING INSTRUCTIONS

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series:

ASK THE EXPERT: Burner Troubleshooting Information & Maintenance

Your safety and the safety of others are very important.

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

CARING FOR YOUR WATER HEATER

TWO BURNER PROPANE CAMPING STOVE

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Electronic Ignition Fire Pit Insert

USE AND CARE MANUAL FOR OUTDOOR USE ONLY MADE IN THE U.S.A.

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

WARNING: FOR OUTDOOR USE ONLY

SPARK MODERN FIRES RETROFIT FIRE RIBBON VENTED DECORATIVE APPLIANCE OWNER S OPERATION AND INSTALLATION MANUAL

OUTDOOR GAS FIREPLACE USER GUIDE North America _2 EF

INSTALLATION MANUAL GAS COOKTOP. Please read this guide thoroughly before installation. P/No.: MFL

!"" #$% "!&' ( ( ) *

TWO BURNER PROPANE CAMPING STOVE

Electronic Ignition Fire Pit Insert

Owner s Manual PATIO HEATER

The growing popularity of Gas Fireplaces has created a demand for an ever increasing array of styles and sizes to fit every decor and budget.

G670 Intermittent Pilot Ignition Controls

30" GAS RANGE INSTALLATION INSTRUCTIONS (For Models with Sealed Top Burners)

HEAT WAVE DUCT KIT KIT #

30" GAS RANGE INSTALLATION INSTRUCTIONS (For Models with Sealed Top Burners)

INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE

UNVENTED (VENT-FREE) GAS LOG HEATER OWNER S OPERATION AND INSTALLATION MANUAL. BGe18NR, BGe18PR, BGe2436NR and BGe2436PR

T360 Barbecue. Assembly Manual (G30531) Propane 1 YEAR LIMITED WARRANTY

Assembly Instructions & User s Manual Triton Classic Gas & Charcoal Grill Model #: FSOGBG3005

Gas-Fired, Residential Storage Type Water Heaters

Operator: Save these instructions for future use!

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

Installation Instructions for Alarm Module Kit A043F059

VENT-FREE GAS LOG SET

Applies to: Models F, B, FE, and BE FOR YOUR SAFETY

Instantaneous gas water heater

3 WATT LED SPOTLIGHT Model No. SLM

READ AND SAVE THESE INSTRUCTIONS

Evaluate, Clean, and Tune Guidance

Tankless Water Heater

Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces

Churrasco/Grill Manual Models: 2ft, 3ft, 4ft, 5ft & 6ft (with or without motor driven spits)

2010 Residential Water Heater Replacement Check List

Please keep this manual for f uture reference.

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

Crux TM. Canister mounted stove for outdoor use SWE OPTIMUS CLEVER COOKING SINCE 1899

Float and Thermostatic Traps Series H, C and X

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

OBSOLETE. VS8510,VS8520 Millivolt Gas Valve

INSTALLATION INSTRUCTIONS

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

OUTDOOR LP HOT WATER HEATER CARE, USE AND SAFETY INSTRUCTIONS

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

OBSOLETE. VS8420 Millivolt Gas Valve

GNOME PELLET E.I. Pellet Heater Owner's Manual Installation and Operating Instructions. Please read this entire manual before installation.

PROPANE CONSTRUCTION HEATER

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Instruction Manual for Residential Manufactured Home Gas Water Heaters

WARNING: IMPROPER SERVICING AND START-UP OF THIS EQUIPMENT MAY CREATE A POTENTIAL HAZARD TO EQUIPMENT AND TO OPERATORS OR PERSONS IN THE BUILDING.

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

CAUTION - FOR YOUR SAFETY

THREE. Heating and Cooling

OTF Oil Fired Pool Heater

OUTDOOR PIZZA OVEN INNOVATIVE DESIGN CREATES CULINARY PERFECTION

GAS DOUBLE OVEN RANGE

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

PARTS NEEDED FOR CONVERTING FROM LP TO NG

VENT-FREE GAS LOG SET


IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

UNVENTED (VENT-FREE) INFRARED GAS HEATER SAFETY INFORMATION AND INSTALLATION MANUAL

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

Table of Contents WARNING SYMBOLS AND DEFINITIONS

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

RESIDENTIAL GAS-FIRED WATER HEATERS OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Owner s Manual & Safety Instructions

heating 3 & cooling heating and cooling 2010 PulteGroup, Inc. All Rights Reserved.

Electric Water Heater

Installation Operation & Maintenance Manual

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

HIGH PRESSURE RADIANT GAS BROODER MODELS: SHP17B (-6) MODULATING

AWWA Butterfly Valve Operation and Maintenance Manual Series 511A & 510A 20 and Smaller

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Transcription:

FYRESIDE GAS FIREPLACE LOG SET Owner s Manual AVAILABLE IN THE FOLLOWING LOG STYLES Live Oak (YE) Live Oak Custom (YDE) Split Live Oak (SE) Canyon Oak (CE) FOR INSTALLATION IN SOLID-FUEL BURNING FIREPLACES Natural and propane models WARNING If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, personal injury, or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS: 1. Do not try to light any appliance. 2. Do not touch any electrical switch; do not use any phone in the building. 3. Immediately call the gas supplier from a neighbor s phone and follow the gas supplier s instructions. 4. If you cannot reach the gas supplier, call the fi re department. Installation and service must be performed by an NFI Certified or other qualified professional installer, service agency, or the gas supplier. REV 8-1602020945 WITH GLOWING EMBER BURNER Important: Read these instructions carefully before starting installation of the log set. WHEN THE LOG SET IS OPERATING, THE DAMPER MUST BE FULLY OPEN. THE LOG SET IS TO BE BURNED ONLY IN A FULLY VENTED, NONCOMBUSTIBLE FIREPLACE WITH DAMPER AND CHIMNEY FREE OF ANY OBSTRUCTIONS. THE FIREPLACE MUST BE DESIGNED AND APPROVED TO BURN WOOD. Like burning natural fi rewood, the log set is designed to burn with a yellow, smoky fl ame. For this reason, it must be adequately vented. The fireplace damper must be fully open when you burn the gas log set. If adequate ventilation is not provided as detailed on this instruction, DO NOT USE THIS LOG SET. If fumes from the burner emerge into the room when the damper is fully open, creating a smell like a smoldering oil lamp, it indicates that the fireplace draft is defective. Check chimney fl ue for obstructions. DO NOT OPERATE LOGS UNTIL THE FIREPLACE DRAFT IS CORRECTED. Check with the dealer or installer. Do not use fi rewood with this unit. Accepted by leading national and local building codes and authorities. INSTALLER & CONSUMER These instructions MUST be retained with this appliance. International Building City of Conference Offi cials Los Angeles of Building Conference of General Offi cials America Inc. Approval Report No. 93-10 Listing No. 1188 M-730225 CAL-1001 Fyreside Products 14724 East Proctor Avenue City of Industry, CA 91746 1 L-A2-006

TABLE OF CONTENTS 2 TABLE OF CONTENTS 3 IMPORTANT PRE-INSTALLATION AND FIREPLACE SAFETY INFORMATION 4 FIREPLACE OPERATING SAFETY INFORMATION 5 IMPORTANT INFORMATION 5 PARTS LIST 6 INSTALLATION 6 INSTALLING THE BURNER 7 GRANULE, EMBER, AND GRATE PLACEMENT 8 LOG PLACEMENT 9 LIGHTING INSTRUCTIONS 9 MAINTENANCE & SERVICE 10 TROUBLESHOOTING 11 FLAME DESCRIPTION 12 WARRANTY IMPORTANT For all valves, the air MUST be purged from the gas line before the pilot will light properly. The time taken to do this will depend on the length of gas line from the meter to the unit and the length of time since the unit or gas line was last used (in the case of non-use during warm weather for example). It may take from 3-15 minutes before all the air is purged and the pilot will light properly. This is done using the method for lighting the pilot, but holding in the control valve for a longer period. Follow the LIGHTING INSTRUCTIONS in this manual for your specifi c valve type. REV 8-1602020945 2 L-A2-006

IMPORTANT PRE-INSTALLATION AND FIREPLACE SAFETY INFORMATION CAUTION: Installation and repair must be done by an NFI Certified or other qualified professional installer. Installer: Carefully read these instructions before installing this gas burner system. Be sure you understand all safety precautions and warnings contained in this manual. A. CAUTION: If not installed, serviced, and used correctly per these instructions, this product can cause serious personal injury, property damage, or loss of life. B. WARNING: Before installing in a solid-fuel-burning fireplace, the chimney flue, damper, and firebox must be thoroughly CLEANED of soot, creosote, ashes, and loose paint, and must be inspected by a qualifi ed chimney cleaner. Some older fi replaces may need repair prior to installing this appliance. C. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is NOT CONVERTIBLE for use with other gasses. CHECK GAS TYPE (natural or L.P.): The gas supply must be the same as stated on your burner system rating plate. If gas supply is different, DO NOT INSTALL. Contact your dealer for immediate assistance. D. INSUFFICIENT GAS PRESSURE WILL KEEP THE UNIT FROM OPERATING PROPERLY. DO NOT USE IF GAS PRESSURE IS LOWER THAN THE MINIMUM REQUIREMENT. E. The minimum inlet gas-supply pressure for purposes of input adjustment is 5" water column (w.c.) on natural gas and 11" w.c. on L.P. gas. Insuffi cient gas pressure will affect proper operation of the pilot (if equipped). Do not install this gas appliance if minimum pressure is not available. The maximum inlet gas-supply pressure is 10.5" w.c. on natural gas and 13" w.c. on L.P. gas. The L.P. source must be regulated. (Do not connect this appliance directly to an unregulated L.P. gas tank - this can cause an explosion.) Do not connect this appliance to a portable L.P. gas cylinder. F. The gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate (BTU/hr). Undue pressure loss will occur if the pipe is too small, or the run is too long. Gas supply pipe must be 1 / 2 " minimum interior diameter. If the gas line is longer than 20', a larger diameter line may be necessary. Refer to the NFPA 54 guidelines for further details. G. Input ratings shown in BTU per hour are for elevations up to 2,000 ft. For elevations above 2,000 ft., refer to the National Fuel Gas Code or contact manufacturer before installing this product. H. This gas appliance and its main gas valve must be disconnected from the gas-supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig. I. This gas appliance must be isolated from the gas-supply piping system by closing the equipment shutoff valve connected to the gas-supply line during any pressure testing of the gas-supply piping system at test pressures equal to or less than 1/2 psig. J. To install the gas appliance in your fireplace, the fireplace MUST meet the minimum size requirements (see minimum fireplace dimension table in SPECIFICATIONS section). K. This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) home, where not prohibited by local codes. Installation of appliances designed for manufactured home (U.S. only) or mobile home installation must conform with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not applicable, ANSI/ NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard. L. DO NOT install this burner system if the fireplace hearth is recessed. The fireplace floor must be at the same level as or higher than the fireplace front opening. If glass doors are used: the fi replace floor must not be blocked by the door frame; the frame must have openings to allow for fresh air circulation. 3

FIREPLACE OPERATING SAFETY INFORMATION A. Adults shall be present when this gas appliance is operating. This unit shall not be left burning when unattended or while anyone is sleeping. B. Keep the area of the gas burner system clear and free from combustible materials, gasoline, and other fl ammable vapors and liquids. C. DO NOT use this appliance if any part has been underwater. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been underwater. Attempted operation may result in fi re or explosion resulting in property damage, personal injury or loss of life. D. A fireplace screen must be in place when the system is burning. Provisions for adequate combustion air must be maintained. Unless other provisions for combustion air are provided, the screen shall have an opening(s) for introduction of combustion air. Combustion air is adequate when all fl ames curl into the fi replace and away from the screen. When a glass fireplace enclosure (door) is used, leave the doors fully open when the system is in operation. E. Do not remove the rating plates or the warning tags. These are an integral safety and identifi cation component of this appliance. F. Be sure to read the CLEANING AND SERVICING and FLAME DESCRIPTION sections. 4

IMPORTANT INFORMATION Check to be sure the gas log set is designed for the proper gas type. These log sets are designed for use with natural gas unless clearly labeled for propane gas. Sets designed for use with propane gas must be installed with a safety pilot system. Never use propane gas in a log set designed for natural gas or natural gas in a log set designed for use with propane gas. The installation, including provisions for combustion and ventilation air, must conform with local codes or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 and NFPA54. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system when testing at test pressures in excess of 1/2 psi. The appliance must be isolated from the gassupply piping system by closing its individual manual shutoff valve during any pressure testing of the gas-supply system at test pressures equal to or less than 1/2 psi. This is accomplished by closing the gas-supply line valve. The minimum inlet gas-supply pressure for the purpose of input adjustment is 5" water column (w.c.) for natural gas and 10" w.c. for propane gas. The maximum inlet gas-supply pressure for this burner is 10.5" w.c. for natural gas and 13" w.c. for propane gas. A fi replace screen must be in place when the log set is burning. WHEN GLASS FIREPLACE ENCLOSURES (DOORS) ARE USED, OPERATE THE GAS LOG SET WITH THE GLASS DOORS FULLY OPEN. The minimum-size fi replace in which the series burner is to be installed is listed in the table below: Log Set Size Technical Data Table Minimum Fire Box Dimensions Front Opening Width* Depth Height 18" 24" 14" 18" 20" 26" 14" 18" 24" 30" 14" 18" 30" 36" 15" 18" * This required width allows for centering of the log set. Add 4" to front width if the burner is to be installed with a pilot kit. PARTS LIST 6 3 7 ITEM NO. DESCRIPTION 1. Front bottom log 2. Rear bottom log 5 4 8 9 3. Top log 4. Top log 2 5. Top log 6. Top log 1 7. Fireplace grate 8. Burner pan 9. Fuel injector (natural gas) Air mixer (propane gas) 12 13 11 10 10. Embers 11. or Select sand granules (natural gas) Vermiculite granules (propane gas) 12. Damper clamp (64-YE SET ILLUSTRATED) 13. Stabilizer clips (replacement package also includes a damper clamp) 5

INSTALLATION The damper clamp with hex bolt (Fig. 6-1) is provided as a means to prevent full closure of the damper blade. The clamp is easily attached to most damper blades with pliers or a wrench, and must be permanently installed. The clamp is designed to prevent accidental closure of the damper when installed as illustrated (Fig. 6-2 and Fig. 6-3). Should the clamp not fit, or fail to provide the permanent vent opening listed in the table found above, have a permanent stop installed, remove the damper blade, or have the damper cut to provide the minimum permanent Set screw opening required. Note: These are minimum damper opening specifications. The damper must be completely opened when operating this gas appliance to achieve the best ventilation possible. Damper clamp Fig. 6-1 Open Closed Fig. 6-2 Fig. 6-3 INSTALLING THE BURNER The gas log set must be installed by a qualifi ed professional service technician. Instructions must be followed carefully to ensure proper performance and full benefi t from the gas log set. Check to be sure the log set is designed and labeled for the type of gas (natural or propane gas) supplied to the fireplace. Fireplace floor must be level, clean, and smooth. WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. REFER TO THE PARTS LIST WHEN FOLLOWING THESE INSTRUCTIONS. If your burner is to be installed with a pilot kit; carefully follow the instructions supplied with your pilot kit for specific gas connection. The burner pan is supplied with an air mixer for propane gas or a fuel injector for natural gas. The air mixer / fuel injector must be used in ALL installations. The air mixer / fuel injector has a precisely sized orifi ce to ensure only the proper quantity of gas enters the burner. This allows maximum performance and gas conservation. 1. MAKE SURE THE FIREPLACE GAS SUPPLY IS TURNED OFF. 2. Locate the gas-supply stub inside the fi replace and remove the cap, if attached (see Fig. 6-4). CAUTION: When removing the cap, make sure the stub does not turn, loosening the connection inside the wall. 3. Attach a flex connector and any required fittings (not included) to the fuel injector / air mixer on the burner pan, using a pipe compound resistant to all gases as needed. Tighten securely. DO NOT REMOVE THE FUEL INJECTOR / AIR MIXER. 4. Place the burner system into the fi replace so the open burner pan faces outward. 5. Locate the grate (Item 7) and attach the stabilizer clips (Item 13) to the 2 outer bars of the grate with screws and nuts. The stabilizer clips should be positioned towards the middle of the bars (Fig. 6-5). Place a clip on each side of the bar, insert the screw, attach the nut, and loosely tighten. Repeat for the other side. 6. Place the grate over the burner pan so the stabilizer clips fi t over the back edge of the burner pan to lock it in position. Completely tighten the clips in place. Fig. 6-4 Fig. 6-5 Stabilizer clips on grate GRATE STABILIZER CLIPS BACK WALL OF FIREPLACE Gas line cap Gas supply line stub BURNER PAN 6

7. Center this assembly in the fireplace and place it as far back in the fi replace as possible. Remove the grate for the gas connection and granule/ember placement. 8. Be sure gas to the fireplace is off. Attach the flex connector and any required fittings to the gassupply stub using a pipe compound resistant to all gases as needed. Tighten securely. Ensure the pan rests level on the fireplace floor after connection. Adjust the pan if necessary. 9. LEAK TEST: Use a long-necked butane lighter, or lay a lighted match next to the burner pipe, and carefully turn on the gas supply until the burner ignites. Test at all connections for leaks using the appropriate soapy water solution. If bubbles INSTALLATION (cont.) appear, a leak is present. Turn off the gas and tighten at all connections. Repeat until no leaks are present. If a leak persists, turn off the gas supply and contact the local gas company or dealer. NEVER USE A FLAME TO CHECK FOR LEAKS. Turn off the gas supply prior to proceeding. GRANULE, EMBER, AND GRATE PLACEMENT GRANULE PLACEMENT The granules supplied with the unit are specially selected for use with either propane gas or natural gas. They maximize fl ame distribution and reduce carbon buildup. 1. Fill the burner pan completely with the granules* (Item 11). See Fig. 7-2. Avoid spilling the granules on the pilot kit (if equipped). *Note: Use only select sand for natural gas burners and vermiculite for propane gas burners. 2. Slope the granules at the same angle as the burner pan. This is important to ensure quiet lighting and even fl ame distribution. Fig. 7-1 - Fireplace valve * Not included Fuel injector Place granules in pan & slope to angle of pan Back wall of fireplace Burner pan Fig. 7-2 Granule placement EMBER PLACEMENT Sprinkle the glowing embers (Item 10) lightly and evenly over the entire surface of the granules. Break up any clumps that may have developed during shipment. Important: Do not add any additional embers to this log set. Any additional embers may cause unsafe operation. GRATE PLACEMENT Replace the grate so that the stabilizer clips fi t over the back edge of the pan, locking it in position. Burner Pan Small adapter * Gas supply line Flex connector * Large adapter * 7

LOG PLACEMENT 1. Log placement is very important for the proper operation and performance of the gas log set. Although you have some fl exibility in the log arrangement, it is necessary to follow the log placement instructions carefully to fully enjoy the log set. 2. Place the longest log in front with the flat side facing to the rear. The secondlongest log is placed on the back of the grate with the fl at side facing the rear. Provide a minimum 3" space between the front and rear logs (Fig. 8-1). 3. Place the middle/top logs diagonally with space between the logs so that the fl ames are not choked off. Adjust the middle/top logs until desired look, and fl ame pattern are achieved. Flexibility is possible provided excessive sooting does not result from flames striking the logs too directly. 3" Fig. 8-1 CAUTION: Burn hazard. Logs will remain hot for some time after use. You must maintain the log layout as shown to ensure proper operation of your log set. If you need to reposition any log to maintain the proper layout, use heat-resistant gloves or allow logs adequate time to cool before handling. 8

LIGHTING INSTRUCTIONS Before operating your gas log set: 1. Be sure your fi replace is free from fl ammable liquids or combustible materials. 2. Be sure your damper is open. 3. Smell all around the gas log set for the odor of escaping gas. IF YOU SMELL GAS, FOLLOW THE INSTRUCTIONS ON P. 1. If your gas log set is operated by the fireplace valve: 1. Lay a lighted long-stem match on the surface of the embers near the gas inlet (do not hold the match in your hand) or use a lighted long-necked butane lighter (Fig. 9-1). 2. Slowly turn the fi replace remote valve to the ON position. Your log set should light. 3. If the log set does not light before the match goes out, immediately turn the valve to the OFF position. 4. Wait approximately fi ve (5) minutes to clear out any gas, and repeat steps 1-3 above. 5. If your log set fails to light again, turn the valve to the OFF position and contact your dealer or gas supplier. 6. To extinguish your gas log set, turn the valve to the OFF position. Be sure the valve is turned fully off to avoid any gas leakage. If your burner is operated by a pilot kit: Fig. 9-1 Apply match - then turn on gas 1. Carefully follow the lighting instructions supplied with your pilot kit for the steps to ignite the burner. MAINTENANCE & SERVICE Maintenance Once installed and operating properly, your gas log set will require regular maintenance. You should inspect your log set and controls (where installed) for the following: 1. Excessive sooting - Some sooting of your log set is normal, adding to the appearance of burned wood. If excessive sooting accumulates, clean the logs using any of the following options: Option 1. Spray the logs with clean water when they are being burned and hot. The soot will lift off and burn off. Option 2. Brush the soot off with a stiff brush when the logs are cold. Do not use water or soot cleaners at the same time as brushing the soot off. 2. Moisture may cause the granules and Glowing Embers in your burner pan to settle. To improve the burn, follow these tips. a. Settling of sand (or vermiculite) - Using a screwdriver or fl at-blade knife, carefully stir the granules, loosening the material. Clear up any spills. b. Embers - Break up any clumps that may have formed, then redistribute the embers on the granules. 3. Debris around the control (where used) - Inspect control and pilot to be sure it is free of dirt or debris. Service While some minor service conditions may be handled by the owner of the log set, it is recommended that a qualifi ed professional service technician be called to maintain and service the gas log set and any installed control system. The TROUBLESHOOTING section of these instructions serves as a guide for ensuring optimum performance of your gas log set. 9

1 POSSIBLE CAUSE A. Insuffi cient or excessive gas pressure TROUBLESHOOTING SOLUTIONS BURNER SHUTTING DOWN DURING OPERATION A1. Check gas pressure (Read E.- G. of IMPORTANT PRE-INSTALLATION AND FIREPLACE SAFETY INFORMATION section, & check with local gas company). A2. Other gas appliances may be on the same gas line, dropping gas pressure to log set. Check pressures with everything operating to ensure adequate pressure. B. Log placement B. Reference the LOG PLACEMENT section in this manual for recommended log positioning. C. Flue area, fireplace, or damper dirty from soot C. Clean around, above, and under damper thoroughly. Clean fireplace, removing loose material, including soot and creosote. D. Fireplace too small for unit D. Ensure minimum requirements are met. (See FIREPLACE SIZE REQUIREMENT section in this owner s manual.) E. Pilot flame lifting off E. Check gas pressure (see section A1). (if pilot is equipped) thermocouple/generator F. Pilot (remote compatible) F. Contact your dealer for instructions on replacement. (if pilot is equipped) G. Blockages on burner G. Vacuum any lava granules or material that may have fallen onto burner pipe area. 2 A. Pilot flame lifting off thermocouple/generator B. Electronic spark not lighting pilot PILOT WILL PILOT NOT WILL LIGHT NOT (IF LIGHT PILOT IS EQUIPPED) A. Check gas pressure (see Section 1, A1 of this table). B. Check to ensure sparking when activated. Note: You may need to turn or press ignitor several times to ignite pilot. See LIGHTING INSTRUCTIONS for your control valve. C. Ignitor electrode wire loose C. Check wiring and reconnect any loose wiring. D. Gas supply off/manual D. Turn on gas supply or open manual shutoff valve. shutoff valve closed E. Air in gas line E. Bleed the gas supply line and repeat LIGHTING INSTRUCTIONS until air is removed. F. Pilot hood blocked F. Check for debris or dirt / Clean pilot G. Dead batteries (electronic pilots only) G. Replace batteries as needed. 3 LOW FLAME HEIGHT A. Gas pressure A. Check gas pressure (see Section 1, A1 of this table). 4 BURNER NOT BURNING EVENLY A. Burner orifi ce clogged A. Clean burner orifi ce. B. Top burner lights; bottom burner has delayed ignition. 5 B1. Check gas pressure. Can be caused by too small of a gas line (see Section 1, A1 of this table). B2. Low propane tank level. Vacuum burner tube for soot blockage and fill propane tank. ODORS A. Gas leak A. Shut off gas, if possible. Follow instructions on front page. Have a qualifi ed professional installer or the gas company correct all leaks. B. New home, new carpet, or new paint B. When these odors are drawn into the fi replace, this may cause objectionable odors. Thoroughly ventilate the area before restarting your log set. 10

6 POSSIBLE CAUSE TROUBLESHOOTING (Cont.) SOOTING SOLUTIONS A. On logs, in fi rebox, or room A. Check gas pressure (see Section 1, A1 of this table). B. Drafts in room B. Eliminate drafts by closing heating and air conditioning vents, returns, and outside air vents. Fans blowing directly into fi replace should be turned off when set is operating. C. Air shutters blocked (if applicable) C. Air shutters are blocked with debris. Vacuum debris away from air shutter. D. Log placement D. See solution in Section 1, B. E. Using natural-gas burner on propane gas or propane burner on natural gas E. If the gas listed on the nameplate does not match the gas you are burning, shut down the burner system immediately. Then call your dealer. F. Adding any accessories to log sets F. Shut down log set and take off any logs or accessories that do not belong with the set. 7 PILOT WILL PILOT NOT WILL STAY NOT LIT (IF STAY PILOT LITIS EQUIPPED) A. Valve won t hold A. Contact your dealer for instructions on replacement. B. Pilot hood not aimed at thermocouple B. Pilot hood bent; replace pilot or angle pilot hood properly so pilot fl ame hits thermocouple. C. Pilot line bent / kinked at connection to valve C. Replace pilot line. D. Thermocouple is loose D. Tighten thermocouple nut at gas control valve. (Do not over tighten). E. Thermocouple cracked or worn out E. Replace thermocouple. F. Excessive down draft F. Install chimney cap / Outside chimney too close to other peaks / Check chimney fl ue for proper height / Poorly designed chimney. Observe the flames. The main burner flames should be blue at the base and a combination of blue/ yellow at the body and at the tips. They should be 5"(127mm) to 8"(203mm) above the logs, with the center fl ame being the tallest (see cover photo). The ember flames should be 1/4" (6mm) above the embers. FLAME DESCRIPTION 11

WARRANTY FYRESIDE UNVENTED DECORATIVE GAS APPLIANCE LIMITED WARRANTY Robert H. Peterson Co. ("RHP") warrants your Fyreside unvented decorative gas appliance to be free from defects in material and workmanship. Fyreside unvented ceramic refractory gas logs are warranted for FIVE (5) YEARS. Fyreside unvented burner component parts, except valves, ODS pilots, and controls, are warranted for TWO (2) YEARS. Fyreside valves, ODS pilots, and controls are warranted for ONE (1) YEAR (excluding batteries). A COPY OF YOUR SALES SLIP FOR PROOF OF PURCHASE IS REQUIRED This warranty applies to the original purchaser for products which are installed in the United States or Canada and which are operated and maintained as intended for single family residential usage. This warranty is valid only with proof of purchase, shall commence on the date of purchase, and shall terminate (both as to original and any replacement products) on the anniversary date of the original purchase of the product stated on the above schedules. This warranty covers defects in material and workmanship. This warranty does not cover parts which become defective as a result of negligence, misuse, use not in compliance with the Owner s Manual/Installation Instructions, accidental damage, improper handling, improper storage, improper installation, lack of required routine maintenance (as specifi ed in the Owner s Manual/Installation Instructions), electrical damage, local gas impurities or failure to protect against combustibles. Product must be installed (and gas must be connected) as specifi ed in the Owner s Manual/Installation Instructions by a qualified professional installer. Modifi cations to products which are not specifi cally authorized will void this warranty. Accessories, parts, valves, remotes, etc. when used must be Peterson products or this warranty is void. Warrantied items will be repaired or replaced at Peterson s sole discretion. This warranty does not apply to rust, corrosion, oxidation, or discoloration unless the affected part becomes inoperable. This warranty does not cover labor or labor related charges, except as provided by separate specifi c written programs from the Peterson Co. All repair work must be performed by a qualifi ed professional service person and requires prior approval of Peterson. Peterson may require the defective product or part to be returned to the factory to determine the cause of failure. Peterson will pay freight charges if the product or part is determined to be defective. This warranty does not cover breakage in shipment from our (Independent) distributor to its customer if the damage is determined to have occurred during that shipment. This warranty specifi cally excludes liability for indirect, incidental, or consequential damages. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion may not apply to you. This warranty gives you specifi ed legal rights, and you may have other rights that vary from state to state or province. For additional information regarding this warranty, or to place a warranty claim, contact the R. H. Peterson dealer where the product was purchased. TO REGISTER YOUR PRODUCT ONLINE GO TO: WWW.RHPETERSON.COM, AND CLICK ON PRODUCT REGISTRATION. THANK YOU FOR YOUR PURCHASE. Quality Check Date: Burner Orifices Nat. L.P. Leak Test: Model#: Main: Burn Test: Serial#: Other: Gas Type: Nat. / L.P. Air Shutter: Inspector: Robert Fyreside H. Peterson Products Co. 14724 East East Proctor Avenue City City of of Industry, CA CA 91746 12