1 SPARK MODERN FIRES RETROFIT FIRE RIBBON VENTED DECORATIVE APPLIANCE OWNER S OPERATION AND INSTALLATION MANUAL Z21.60b-2004 / CSA 2.26b-2004 APPROVED 321-L-06-5 WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or gas supplier. - Installation and service must be performed by a qualified installer, service agency, or the gas supplier. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. - WHAT TO DO IF YOU SMELL GAS: Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor s phone. Follow the gas supplier s instructions. If you cannot reach your gas supplier, call the fire department. WARNING: This appliance is for installation only in a solid-fuel burning masonry or UL127 factory-built fireplace, constructed of noncombustible material, and connected to a working flue (see page 4 for minimum flue opening). WARNING: This is a gas-fired appliance. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. INSTALLER: Leave this manual with the appliance. CONSUMER:Retain this manual for future reference NOTE: This appliance is not approved for installation in bedrooms or bathrooms.

2 SAFETY INFORMATION 2 WARNINGS WARNING: Keep flue open when operating unit. IMPORTANT: Read this owner s manual carefully and completely before trying to assemble, operate, or service this Fire Ribbon. Improper use of this unit can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning. DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the fire Ribbon may not be working properly. Get fresh air at once! Have Fire Ribbon serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes. Natural and Propane /LP Gas: Natural and propane /LP gases are odorless. An odor making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this Fire Ribbon. WARNING: Any change to this Fire Ribbon or its controls can be dangerous. 1. This appliance, as supplied, is only for use with the type of gas indicated on the rating plate. 2. If you smell gas: shut off gas supply do not try to light any appliance do not touch any electrical switch; do not use any phone in your building immediately call to your gas supplier from a neighbor s phone. Follow the gas supplier s instructions if you cannot reach your gas supplier, call the fire department 3. Never install the Fire Ribbon: in a recreational vehicle where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the Fire Ribbon in the high traffic areas in windy or drafty areas 4. Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. Inspect chimney flue for damage. 5. Fire Ribbon is designed to be smokeless. If it ever appears to smoke, turn off appliance and call a qualified service person. NOTE: During initial operation, slight smoking could occur due to unit curing and the burning of manufacturing residues. 6. To reduce the creation of soot, follow the instructions in Cleaning and Maintenance, page Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns, as it could increase soothing. 8. Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this Fire Ribbon. 9. This Fire Ribbon needs fresh, outside air ventilation to run properly. 10. Keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids. 11. Do not burn solid fuel in the fireplace after installing the Fire Ribbon. Do not use this appliance to cook food or burn paper or other objects. 12. Fire Ribbon becomes hot when in use. Keep children and adults away from hot surface to avoid burns or clothing ignition. Fire Ribbon will remain hot for a time after shut-down. Allow surface to cool before touching. 13. Carefully supervise young children when they are in the room with Fire Ribbon. 14. Do not use appliance if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the room appliance and to replace any part of the

3 control system and any gas control which has been under water. 15. Turn the Ribbon off and let cool before servicing, installing, or repairing. Only a qualified service person should install, service, or repair Fire Ribbon. LOCAL CODES Install and use Fire Ribbon with care. Follow local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSZ223.1, also known as NFPA 54 available from: American National Standards Institute, Inc., 1430 Broadway, New York, NY National Fire Protection Association, Inc., Batterymarch Park, Quincy, MA PRODUCT ASSEMBLY WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specially approved with this appliance may result in property damage or personal injury. packaging (see Parts List, page 14). 2. Connect the Burner Assembly to gas supply using supplied flex connector and shutoff valve. 3. Evenly fill the media compartment with burner media (broken tempered glass) fully covering the burner as shown on a picture. If you are NOT planning to add optional topping media, then fill the media compartment in full and proceed to the step 5. NOTE: If you are planning to add some topping media (optional colored glass or lava rock), leave approximately ¾ not filled on top of burner media and proceed to the next step. 4. Place and evenly distribute topping media (optional colored glass or lava rock) on top of burner media as shown on a picture. Make sure that pilot opening is not blocked with excess of media. 5. Carefully leak test all connections following the procedure on page Having free access to the valve and manifold compartment of the Burner Assembly turn ON the appliance following the procedure on page 7. Make sure the flame is even along the burner and appliance is fully operational and safe for use. Turn OFF the appliance and let it cool before proceeding to the next step. 7. Cover manifold and valve compartment of the Burner Assembly with Front Cover making sure that access window is located above the valve as shown on a picture. Cover the window with Access Panel as shown on a picture. 1. Remove Burner Assembly, Front Cover, Access Panel and Burner Media from 3

4 INSTALLATION CAUTION: Do not remove the metal data plates attached to the Fire Ribbon. These plates contain important information. WARNING: Before installling in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and distribute soot within the house. Inspect chimney flue for damage. NOTICE: Installation, service, and repair of this appliance must be performed by a qualified installer, service agency, company or gas supplier experienced with this type of gas appliances. Only factory authorized components listed in this instruction may be used in accordance with the manufacturer s instructtions and all codes and requirements of the authority having jurisdiction. Any modifications to this appliance or use of unauthorized components or accessory items will void the manufacturer s warranty, and may result in a hazardous condition. NOTE: This vented appliance must be installed only in a solidfuel burning fireplace with a working flue and constructed of noncombustible material. The installation of appliances designed for manufactured home (U.S. only) or mobile home installation must conform with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the USA, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard. The fireplace must include a working flue and venting system with minimum opening. Please, make sure that the following technical data related to proper installation of the Fire Ribbon are applicable before installation is attempted. Minimum firebox size: - Height 18 - Depth 14 - Width/Model: RETRO RETRO RETRO RETRO RETRO RETRO RETRO Fuel Pressure Specification: - Inlet (NG) w.c. - Manifold (NG) 3.5 w.c. - Inlet (LP) w.c. - Manifold (LP) 10 w.c. VENTING SPECIFICATIONS FOR INSTALLATION The fireplace chimney flue and vent must be drafting properly. To check the vent for proper drafting: Light a tightly rolled newspaper on the end and place it at the inside front edge of the fireplace. Observe the smoke and be sure the vent is properly drawing it up the chimney. If the smoke spills out into the room, extinguish the flame and remove any obstruction until proper venting is achieved. The chimney flue must remain open a minimum of 3 at all times during the operation of this Fire Ribbon. INSTALLING DAMPER CLAMP Secure the damper stop clamp provided to the leading edge of the damper as shown below. If for any reason this clamp doesn t work on your fireplace, another suitable clamp or permanent stop must be installed, or the damper blade must be cut or removed. 4

5 CHECK GAS TYPE FIREPLACE INSTALLATION Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type or conversion kit. INSTALLING GAS PIPING TO FIREPLACE / BURNER SYSTEM LOCATION WARNING A qualified installer or service person must connect appliance to gas supply. Follow all local codes. CAUTION For propane/lp units, never connect fireplace directly to the propane/lp supply. This burner system requires an external regulator (not supplied). Install the external regulator between the burner system and propane/lp supply. INSTALLATION ITEMS NEEDED Before installing fireplace and burner system, make sure you have the items listed below. External regulator (supplied by installer) Piping (check local codes) Sealant (resistant to propane/lp gas) Equipment shutoff valve* Test gauge connection* Sediment trap (recommended) Tee joint Pipe wrench approved flexible gas line with gas connector (if allowed by local codes not provided) * A CSA design-certified equipment shutoff valve with 1 /8" NPT tap is an acceptable alternative to test gauge connection. Purchase the CSA design-certified equipment shutoff valve from your dealer. For propane/lp connections only, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 13 inches of water. If you do not reduce incoming gas pressure, burner system regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 32. Pointing the vent down protects it from freezing rain or sleet. External Regulator 100 lb. (min) Propane/LP Supply Tank Vent Pointing Down CAUTION Use only new black iron or steel pipe. Internally tinned copper or copper tubing can be used per National Fuel Code, section 2.6.3, providing gas meets hydrogen sulfide limits, and where permitted by local codes. Gas piping system must be sized to provide minimum inlet pressure (listed on data plate) at the maximum flow rate (BTU/hr). Undue pressure loss will occur if the pipe is too small. When using copper or flex connectors use only fittings approved for gas connections. The gas control inlet is 3 /8" NPT. Figure 32 - External Regulator with Vent Pointing Down (Propane/LP Only)

6 FIREPLACE INSTALLATION WARNING Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. CAUTION A manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1 /8" NPT pressure tapping point should be installed upstream of the appliance. See Figure 33. NOTE : The gas line connection may be made using 1 /2" rigid tubing or an approved flex connector. Since some municipalities have additional local codes it is always best to consult your local authorities and the current edition of the National Fuel Gas Code ANSI.Z223.1, NFPA54. In Canada CAN/CGA-B149 (1 or 2) Installation Code. A listed manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1 /8" NPT pressure tapping point should be installed upstream of the appliance. See Figure 33. IMPORTANT: Install main gas valve (equipment shutoff valve) in an accessible location. The main gas valve is for turning on or shutting off the gas to the fireplace. Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces. Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged burner system valves. CAUTION Use pipe joint sealant that is resistant to liquid petroleum (LP) gas. We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 33. Locate sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel supply and burner system. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into the burner system gas controls. If sediment trap/drip leg is not installed or is installed wrong, burner system may not run properly. CSA Design-Certified Equipment Shutoff Valve with 1 /8" NPT Tap* Approved Flexible Gas Line Sediment Trap/Drip Leg Tee Joint Pipe Nipple Cap Natural Gas From Gas Meter (5" W.C. to 10.5" W.C. Pressure) Propane/LP From External Regulator (11" W.C. to 13" W.C. Pressure) Figure 33 - Gas Connection 26

7 FIRE RIBBON RETROFIT BURNER MODEL SPECIFICATIONS BURNER TUBE MEDIA BURNER TRAY PILOT 4" 10" CONTROL ACCESS PANEL (L) see chart below MODEL # OVERALL LENGTH (L) FIREPLACE WIDTH (min) INPUT RATE (BTU/Hr) N.G. L.P. # ORIF. ORIF. SIZE N.G. L.P. N.G. (L.P.) RETRO 2 - NG/LP 24" 28" 41,000 33,500 2 (1) RETRO 3 - NG/LP 36" 40" 61,000 54,000 3 (1) RETRO 4 - NG/LP 48" 52" 82,000 72,000 4 ( 1) RETRO 5 - NG/LP 60" 64" 102,000 90,000 5 ( 2) RETRO 6 - NG/LP 72" 76" 116, ,000 6 ( 2) RETRO 7 - NG/LP 84" 90" 129, ,000 7 ( 2) RETRO 8 - NG/LP 96" 100" 142, ,500 8 ( 2) Minimum fireplace depth required = 14 Minimum fireplace height required = 18

8 LIGHTING INSTRUCTION FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This apliance is equiped with a pilot which must be lit by hand while following these instructions exactly. B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS: Do not try to light any appliance. Do not touch any electric switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in, or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part of it has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water. LIGHTING PILOT FOR THE FIRST TIME INITIAL LIGHTING DANGER Purge air from the supply line as follows: Never use an open flame to check for gas leak. Open main shutoff valve. Unscrew main pressure test point. Leave inlet test screw open until gas comes in. When gas is flowing, tighten inlet screw immediately. LEAK TESTING 1. Follow the pipe from the gas supply line connection to the gas valve. Check connection for leaks with soap and water mixture. 2. Next check for gas leaks at the burner with soap and water mixture. 3. Check the pilot for gas leaks with soap and water mixture.

9 Continued LIGHTING PILOT FOR THE FIRST TIME APPROVED LEAK TESTING METHOD You may check for gas leaks with the following methods only: WARNING Soap and water solution WARNING An approved leak testing spray If using a soap and water solution to test Electronic sniffer for leaks, DO NOT spray solution onto control body. DANGER Never use an open flame to check for gas leak. NOTE: Remove any excessive pipe compound from the connections. Excessive pipe compound can set off electronic sniffers. Check for gas leaks in each of the following locations: Pipe from the gas supply line connection to the gas valve Burner connections, pilot Field made joints / gas shutoff valve All joints on valve and control body Factory made joints, each joint and connection LIGHTING INSTRUCTIONS 1. STOP! Read the safety information on previous page. 2. Remove lower cover. 3. Turn the gas control knob to the "OFF" position. 4. Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow "B" in the safety information on the previous page. If you don't smell gas, go to the next step. 5. Locate the Pilot Assembly on the back of Fire Ribbon WA Thermopile PilotAssembly IgnitorElectrode 6. Depress and turn pilot gas knob counterclockwise to "PILOT" position. Knob at Pilot Position 7. Depress fully and hold pilot gas knob. Light pilot with a match or barbeque lighter. Keep knob fully depressed for a few seconds. Release and check that pilot continues to burn. If the pilot does not stay lit, repeat steps 1 and 2. If the pilot knob does not pop up when released, STOP and immediately call service technician or gas supplier If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" position and call your service technician or gas supplier. 9

10 Continued T LIGHTING BURNER MAIN BURNER SWITCH The ON/REMOTE/OFF switch for the main burner can be found on remote control receiver beneath the cover. This switch allows you to turn on and to turn off the main burner without using the gas valve knob. Make sure the button is in the "ON" position to operate the main burner. Receiver Slide Button ADJ. OFF REMOTE ON LEARN LIGHTING THE BURNER Depress and turn the knob counterclockwise to the ON position. It will take less than four (4) seconds for the burner to ignite. On/Off Switch PILOT POSITION Depress and turn knob to pilot position to keep burner off while maintaining the pilot light. On Position Pilot Position TO TURN OFF GAS TO APPLIANCE 1. Remove lower cover. Depress and turn knob clockwise to OFF position. 2. Replace lower cover. Off Position 10

11 CLEANING AND MAINTENANCE WARNING Turn off gas before servicing fireplace. It is recommended that a qualified service technician perform these check-ups at the beginning of each heating season. BURNER, PILOT AND CONTROL COMPARTMENT Keep the control compartment clean by vacuuming or brushing at least twice a year. Make sure the burner porting, pilot air opening and burner air opening are free of obstructions at all times. PILOT FLAME The flames from the pilot should be visually checked as soon as the unit is installed and periodically during normal operation. The pilot flame must always be present when the fireplace is in operation. The pilot flame has two distinct flames, one engulfing the thermopile and the other reaching to the main burner. Thermopile BURNER Inspect area around the injector. Remove any lint or foreign material with a brush or vacuum. VENTING SYSTEM Have the venting system of the solid fuel burning fireplace inspected and cleaned annually by a qualified agency. Pilot Flame 1 11

12 TROUBLESHOOTING WARNING:Turn off Fireribbon and let cool before servicing. Only a qualified service person should service and repair this appliance. Note: All troubleshooting items are listed in order of operation. POSSIBLE CAUSE Unit is smoking / sooting excessively (Note: It is natural and unavoidable for appliance sets to produce moderate levels of carbon (soot) where flames contact the media. This is especially true with propane/lp gas.) REMEDY 1. Poor fuel quality 2. Fireplace venting system not drafting properly 3. Excessive flame impingement or blockage 4. Improper fuel/air mixture 1. Contact local natural or propane/lp gas company 2. Adjust damper wide open and/or have fireplace and venting professionally cleaned and checked 3. Separate the stones to allow more flame passage 4. Remove any foreign items from the flame pattern and/or check for proper orifice sizing Burner is excessively noisy (Note: The movement and combustion of gas will create low, unavoidable levels of noise.) 1. Passage of air/gas across irregular surfaces 2. Excessive gas pressure on natural gas units 1. Relieve any tight bends or kinks in gas supply line 2. Check/reset gas regulator pressure Burner flame is too low or too high Remote does not function 1. Incorrect gas supply or pressure 2. Blocked burner orifice or burner manifold ports 3. Improper burner orifice size 1. Battery is not installed. Battery power is low 1. Check for proper gas supply pressure 2. Free burner orifice and manifold ports of any burrs, paint, or other blockage 3. Verify proper burner orifice sizing (see page 6) 1. Replace batteries in receiver and remote control 12

13 Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY IMPORTANT: Operating unit where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time. WARNING: If you smell gas Shut off gas supply. Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor s phone. Follow the gas supplier s instructions. If you cannot reach your gas supplier, call the fire department. Pilot lights but flame goes out when control knob is released Burner does not light after pilot is lit Delayed ignition burner 1. Control knob not fully pressed in 2. Control knob not pressed in long enough 3. Manual shutoff valve not fully open 4. Pilot flame not touching thermopile, which allows thermopile to cool, causing pilot flame to go out. This problem could be caused by one or both of the following: A) Low gas pressure B) Dirty or partially clogged pilot 5. Thermopile connection loose at control valve 6. Thermopile damaged 7. Control valve damaged 1. Burner orifice clogged 2. Inlet gas pressure is too low 3. Burner orifice diameter is too small 4. Thermopile leads disconnected or improperly connected 1. Pilot flame needs adjusting 1. Press in control knob fully 2. After pilot lights, keep control knob pressed in 30 seconds 3. Fully open manual shut-off valve 4. A) Contact local natural gas company B) Clean pilot (see Cleaning and Maintenance, page 10) or replace pilot assembly 5. Hand tighten until snug, then tighten 1/4 turn more 6. Replace thermopile 7. Replace control valve 1. Clean burner orifice 2. Contact local natural or propane/lp gas company 3. Replace burner orifice 4. Reconnect leads 1. Adjust pilot flame for approximately 1" blue flame 13

14 OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Fire Ribbon produces unwanted odors Gas odor even when control knob is in OFF position Gas odor during combustion 1. Unit burning vapors from paint, hair spray, glues, cleaners, chemicals, new carpet, etc. (See IMPORTANT statement above) 2. Gas leak. See Warning statement at top of page 1. Gas leak. See Warning statement at top of page 2. Control valve defective 1. Gas leak. See Warning statement at top of page 1. Open flue to maximum. Stop using odor causing products while unit is running 2. Locate and correct all leaks (see Checking Gas Connections, page 5) 1. Locate and correct all leaks (see Checking Gas Connections, page 5) 2. Replace control valve 1. Locate and correct all leaks (see Checking Gas Connections, page 5) 14

15 ILLUSTRATED PARTS LIST SE E NE XT PAGE FOR PART DESCRIPTION

16 PARTS LIST This list contains replaceable parts used in your firebox Key # Part Number according to the Fire Ribbon Model for Natural Gas (and LP) Part Description RETRO-2 RETRO-3 RETRO-4 RETRO-5 RETRO-6 RETRO-7 RETRO-8 Q-ty 1 Burner Assembly R R R R R R R (R200012) (R200013) (R200014) (R200015) (R200016) (R200017) (R200018) 2 Main Gas Valve R R R R R R R (R200020) (R200020) (R200020) (R200020) (R200020) (R200020) (R200020) 3 Valve Bracket R R R R R R R Pilot Assembly R R R R R R R (R200022) (R200022) (R200022) (R200022) (R200022) (R200022) (R200022) 5 Burner Flex Connector D D D D D D D Manufold Flex Connector C C C C C C C Damper Clamp F F F F F F F Continued on Next Page 1

17 PARTS LIST (Continued) This list contains replaceable parts used in your firebox Key # Part Number according to the Fire Ribbon Model for Natural Gas (and LP) Part Description RETRO-2 RETRO-3 RETRO-4 RETRO-5 RETRO-6 RETRO-7 RETRO-8 Q-ty 8 Orifice / Air Mixer R (R200061) 1 R (R200062) 1 R (R200063) 1 R (R200064) 2 R (R200065) 2 R (R200066) 2 R (R200067) 2 Continued on Next Page

18 PARTS LIST (Continued) This list contains replaceable parts used in your firebox Key # Part Number according to the Fire Ribbon Model for Natural Gas (and LP) Part Description RETRO-2 RETRO-3 RETRO-4 RETRO-5 RETRO-6 RETRO-7 RETRO-8 Q-ty 9 Burner Manifold R R R R R R R (R200032) (R200033) (R200034) (R200035) (R200036) (R200037) (R200038) 10 Front Cover R R R R R R R Access Panel D400058P D400058P D400058P D400058P D400058P D400058P D400058P 1 12 Remote Control Receiver RCB-R RCB-R RCB-R RCB-R RCB-R RCB-R RCB-R 1 xxx Glass Burner Media (not shown) G G G G G G G N/A xxx Top Media (many available) xxx xxx xxx xxx xxx xxx xxx N/A NOTE: Specifications, finishes and dimensions are subject to change!

19 INSTALLATION RECORD The installer should complete the form below that describes the details of the installation. Having this written record of installation information available will greatly expedite trouble-shooting should any problem arise with your fireplace. The installer should keep a duplicate of this form for their records. Accurate completion of this form is required for warranty coverage and for any technical support by Spark Modern Fires. Date Purchased: Purchaser/Dealer: Installer: Fireplace S/N on product ID tag: Date Installed: FUEL: Natural Gas L.P. Propane Inlet Pressure Measured After Installation: Manifold Pressure Measured After Installation: In. W.C. High Fire: In. W.C. Low Fire: In. W.C. VENTING: Please Verify The Brand And Model Of Venting Used: Vent Termination (Cap): Horizontal Vertical Snorkel Vent Cap Model No: CONFIGURATION: Total Horizontal Run: Total Vertical Run: Quantity 90 Elbows: Quantity 45 Elbows: Feet/Inches Feet/Inches Vent Configuration Sketch Required Below: ALTITUDE: Was Stove Derated? Feet Above Sea Level Yes No If Yes To What Orifice Size? Unusual Structure Near Vent? Inside Corner Trees/Shrubs Other Termination: (Please Describe) Prevalent Wind Conditions? Other Installation Notes: SMF32011

20 WARRANTY INFORMATION KEEP THIS FOR WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory. LIMITED LIFETIME WARRANTY The following components are warranted for life to the original owner, subject to proof of purchase: Fire Ribbon Burner Assembly. BASIC WARRANTY Spark Modern Fires warrants the components and materials in your gas appliance to be free from manufacturing and material defects for a period of two years from date of installation. After installation, if any of the components manufactured by Spark Modern Fires in the appliance are found to be defective in materials or workmanship, Spark Modern Fires will, at its option, replace or repair the defective components at no charge to the original owner. Spark Modern Fires will also pay for reaonable labor costincurred in replacing or repairing such components for a period of two years from date of installation. Any products presented for warranty repair must be accompanied by a dated proof of purchase. This Limited Lifetime Warranty will be void if the appliance is not installed by a qualified installer in accordance with installation instructions. The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance, and does not extend to (1) firebox/burner assembly damaged by accident, neglet, misuse, abuse, alterations, negligence of others, including the installation thereof by unqualified installers, (2) the costs of removal, reinstallation or transportation of defective parts on the appliance, or (3) indentical or consequential damage. All service work must be performed by an authorized service representative. This warranty is expressly in lieu of other warranties, express or implied, including the warranty of merchantability of fitness for purpose and of all other obligations or liabilities. Spark Modern Fires does not assume for it any other obligations or liabilities in connection with sale or use of the appliance. It states that do not allow limitations on how long an implied warranty lasts, or do not allow exclusion of indirect damage, those limitations of exclusions may not apply to you. You may also have additional right not covered in the Limited Lifetime Warranty. Spark Modern Fires reserves the right to investigate any and all the claims against this Warranty and decide upon method of settlement. For information about this warranty contact: Spark Modern Fires 53 Chestnut Woods Rd. Redding, CT U.S.A. Rev.7 11/2013

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS Installation and service must be provided by a qualified installer, service agency or gas supplier Grand Canyon Gas Logs, logs are made

More information

VENTED NATURAL GAS LOGS

VENTED NATURAL GAS LOGS VENTED NATURAL GAS LOGS MODEL #WAN18N-2 WAN24N-2 CAUTION - FOR YOUR SAFETY WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY,

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...

More information

NOTE! READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING.

NOTE! READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING. INSTALLATION AND OPERATION GUIDE FOR HARGROVE GAS LOGS PROPANE GAS ADEQUATE FIREPLACE VENTILATION IS REQUIRED FOR SAFETY. GAS LOGS MUST BE INSTALLED BY PERSONNEL QUALIFIED FOR INSTALLING GAS APPLIANCES.

More information

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL Propane Conversion Kit Supersedes: 145.25-IOM2 (708) Form 145.25-IOM2 (908) PROPANE CONVERSION KIT INSTALLATION MANUAL "LPKIT " - PROPANE CONVERSION KIT Kits are available for field conversion from natural

More information

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION

More information

GAS SAFETY PRECAUTIONS

GAS SAFETY PRECAUTIONS GAS SAFETY PRECAUTIONS Instructions on what to do when a user smells gas can be obtained from the local gas supplier. These instructions must be posted in a prominent location where the unit is to be operated.

More information

CARING FOR YOUR WATER HEATER

CARING FOR YOUR WATER HEATER http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected

More information

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE? WHAT IS A BTU? The standard energy measurement is the BTU (British Thermal Unit). Each BTU unit is determined by the amount of thermal energy required to raise the temperature of one pound of water by

More information

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems American Fireglass Outdoor Fire pit kit information General instructions/warnings for outdoor gas pan and burner systems We strongly recommend that our burner products be installed by a licensed and certified

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS VGBQ SERIES CONVERSION KIT VIKING RANGE CORPORATION 111 Front Street Greenwood, Mississippi (MS) 38930 USA (662) 455-1200 IMPORTANT: PLEASE READ AND FOLLOW 1. Before beginning,

More information

TWO BURNER PROPANE CAMPING STOVE

TWO BURNER PROPANE CAMPING STOVE OWNER S MANUAL ASSEMBLY AND OPERATING INSTRUCTIONS TWO BURNER PROPANE CAMPING STOVE WARNING READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS IN THIS MANUAL TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE. Propane

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS 36C01 Combination Gas Valves (24 Volt and 120 Volt Models) INSTALLATI INSTRUCTIS FAILURE TO READ AND FOLLOW ALL INSTRUCTIS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CTROL COULD CAUSE

More information

SL280UHV SERIES GAS FURNACE WARNING

SL280UHV SERIES GAS FURNACE WARNING 2010 Lennox Industries Inc. Dallas, Texas, USA 506677 01 11/2010 Supersedes 506409 01 SL280UHV SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could

More information

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........

More information

San josé OWNER S MANUAL

San josé OWNER S MANUAL San josé OWNER S MANUAL Assembling & operating manual San josé 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.

More information

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: 150000 200605 LP Gas

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: 150000 200605 LP Gas Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series: 150000 200605 LP Gas Tools needed Bottle brush Non-abrasive scouring pad Small utility brush Heavy-duty pipe cleaners Air hose

More information

Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: 233010 Natural Gas

Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: 233010 Natural Gas Cleaning Instructions, Pilot Replacement and Valve Change Model No.: 233010 Natural Gas 8mm open-end wrench 9mm open-end wrench 10mm open-end wrench 12mm open-end wrench 13mm open-end wrench Phillips screw

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLER/CONSUMER RETAIN THIS APPLIANCE MANUAL WITH THE INSTALLED APPLIANCE INSTALLATION AND OPERATING INSTRUCTIONS GOLDEN BLOUNT TOP-VENT FIREPLACES MODEL HD5030-TV EL GRANDE HD4240-TV SKYSCRAPER CSA

More information

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2000 Conforms to / Conforme à ANSI std Z83.7 2000 Suitable for indoor or outdoor installation / Unvented / Unattended Type

More information

orlando OWNER S MANUAL

orlando OWNER S MANUAL orlando OWNER S MANUAL 2 Assembling & operating manual Orlando 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.

More information

TWO BURNER PROPANE CAMPING STOVE

TWO BURNER PROPANE CAMPING STOVE 842-A100-S_CmpStove.qxd 2/10/06 11:20 AM Page 1 OWNER S MANUAL TWO BURNER PROPANE CAMPING STOVE FAILURE TO FOLLOW ALL S AND INSTRUCTIONS IN THIS MANUAL COULD LEAD TO PERSONAL INJURY, INCLUDING DEATH. RETAIN

More information

!"" #$% "!&' ( ( ) *

! #$% !&' ( ( ) * !"" #$% "!&' (( ) * G Whiz Gas Popper Instruction Manual Model #5908 Part No. 74874 Revised October 1997 Cincinnati, OH 45241-4807 USA GAS SAFETY PRECAUTIONS Instructions on what to do when a user smells

More information

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. UNVENTED (VENT-FREE) INFRARED GAS HEATER SAFETY INFORMATION AND INSTALLATION MANUAL Models GWRP16A, GWRn18A, GWRP26A, GWRn30A GWRP16TA, GWRn18TA, GWRP26TA and GWRn30TA WARNING: If the information in this

More information

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS WARNING Improper installation, adjustment, alteration, service, or maintenance of this product can cause

More information

HEATMASTER, LLC AMERICAN GAS LOG

HEATMASTER, LLC AMERICAN GAS LOG Models: HEATMASTER, LLC AMERICAN GAS LOG DG-SS-18/24/30NG AGL-SS-18/24 NG H-SS-24NG HM2-SS-24NG Outdoor Burner/Hearth Kits For use use with Natural gas only Installation Instructions Installation and service

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. NATURAL GAS TO PROPANE CONVERSION KIT ALPKT7- INSTALLATION INSTRUCTIONS PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements... INSTALLATION INSTRUCTIONS...

More information

Applies to: Models F, B, FE, and BE FOR YOUR SAFETY

Applies to: Models F, B, FE, and BE FOR YOUR SAFETY Form CP-F/B-GC (Version A.2) Obsoletes Form CP-F/B-GC (Version A) Gas Conversion Kits and Instructions Applies to: Models F, B, FE, and BE Model B Model F All gas conversion must be done by a qualified

More information

OWNER S OPERATION AND INSTALLATION MANUAL

OWNER S OPERATION AND INSTALLATION MANUAL BLUE FLAME VENT- FREE PROPANE/LP GAS SPACE HEATER OWNER S OPERATION AND INSTALLATION MANUAL HB06ML- HB0ML- HB0TL- Table of Contents Important Safety Information...2 Product Features...3 Proper Ventilation

More information

UNVENTED (VENT-FREE) GAS LOG HEATER OWNER S OPERATION AND INSTALLATION MANUAL. BGe18NR, BGe18PR, BGe2436NR and BGe2436PR

UNVENTED (VENT-FREE) GAS LOG HEATER OWNER S OPERATION AND INSTALLATION MANUAL. BGe18NR, BGe18PR, BGe2436NR and BGe2436PR UNVENTED (VENT-FREE) GAS LOG HEATER OWNER S OPERATION AND INSTALLATION MANUAL PFS US Remote-Ready BURNER SYSTEM MODELS BG18NR, BG18PR, BG2436NR, BG2436PR, BGe18NR, BGe18PR, BGe2436NR and BGe2436PR FOr

More information

Tankless Water Heater

Tankless Water Heater Tankless Water Heater USER S INFORMATION MANUAL Models WGRTNG199 / WGRTLP199 WGRTCNG199 / WGRTCLP199 NOTICE: Westinghouse reserves the right to make product changes or updates without notice and will not

More information

VENT-FREE GAS LOG SET

VENT-FREE GAS LOG SET VENT-FREE GAS LOG SET MODEL # VFL-CY24DR VFL-HT24DR VFL-CY30DR VFL-HT30DR WARNING: This appliance is equipped for (Natural and Propane) gas. Field conversion is not permitted other than between natural

More information

UNVENTED (VENT-FREE) INFRARED GAS HEATER SAFETY INFORMATION AND INSTALLATION MANUAL

UNVENTED (VENT-FREE) INFRARED GAS HEATER SAFETY INFORMATION AND INSTALLATION MANUAL UNVENTED (VENT-FREE) INFRARED GAS HEATER SAFETY INFORMATION AND INSTALLATION MANUAL Model: IWH10NLTB Model:IWH16NLTB WARNING: If the information in this manual is not followed exactly, a fi re or explosion

More information

LPM-06 CONVERSION KIT

LPM-06 CONVERSION KIT LPM-06 CONVERSION KIT TWO-STAGE FURNACE NATURAL GAS TO L.P. GAS CONVERSION Goodman Manufacturing Company, L.P. 2009-2011 5151 San Felipe, Suite 500, Houston, TX 77056 www.goodmanmfg.com -or- www.amana-hac.com

More information

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference. User s Guide Oreck Air Purifier with HEPA Filtration Important! Read this manual carefully, and keep for future reference. Enjoy Congratulations on your purchase of the Oreck Air Purifier with HEPA Filtration.

More information

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series: 220000-450000

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series: 220000-450000 Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series: 220000-450000 10 mm open end wrench 12 mm open end wrench 9/16 open end wrench 5/8 open end wrench 11/16 open end wrench 9/16

More information

DIRECT VENT GAS FURNACE FOR THROUGH THE WALL OR WINDOW INSTALLATION

DIRECT VENT GAS FURNACE FOR THROUGH THE WALL OR WINDOW INSTALLATION DIRECT VENT GAS FURNACE FOR THROUGH THE WALL OR WINDOW INSTALLATION OWNER'S OPERATION AND INSTALLATION MANUAL SA25N SA25P SA40N SA40P WARNING: If the information in these instructions is not followed exactly,

More information

G670 Intermittent Pilot Ignition Controls

G670 Intermittent Pilot Ignition Controls Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin Issue Date 0300 Intermittent Pilot Ignition Controls Figure 1: Intermittent Pilot Ignition Control

More information

Instruction Manual for Residential Manufactured Home Gas Water Heaters

Instruction Manual for Residential Manufactured Home Gas Water Heaters Instruction Manual for Residential Manufactured Home Gas Water Heaters FOR USE ONLY IN MANUFACTURED HOMES GAMA certification applies to all residential gas water heaters with capacities of 20 to 100 gallons

More information

OUTDOOR GAS FIREPLACE USER GUIDE North America 630165_2 EF5000. www.escea.net

OUTDOOR GAS FIREPLACE USER GUIDE North America 630165_2 EF5000. www.escea.net OUTDOOR GAS FIREPLACE USER GUIDE North America 630165_2 EF5000 www.escea.net Any service work carried out on this appliance must only be done by a recognised escea technician or authorized personnel. The

More information

CAUTION - FOR YOUR SAFETY

CAUTION - FOR YOUR SAFETY WARNING: This appliance is equipped for (Natural and Propane) gas. Field conversion is not permitted other than between natural or propane gases. Vent-Free Gas Log Heater MODEL: PCD8T PCD24TD PCD24M CAUTION

More information

OBSOLETE. VS8510,VS8520 Millivolt Gas Valve

OBSOLETE. VS8510,VS8520 Millivolt Gas Valve APPLICATION The VS8510, VS8520 Millivolt Gas Valve is compact and has a 60,000 Btuh capacity (1 in. pressure drop for straight through configuration). Its design makes it ideal for fireplace and space

More information

2010 Residential Water Heater Replacement Check List

2010 Residential Water Heater Replacement Check List 2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This

More information

HIGH PRESSURE RADIANT GAS BROODER MODELS: SHP17B (-6) MODULATING

HIGH PRESSURE RADIANT GAS BROODER MODELS: SHP17B (-6) MODULATING HIGH PRESSURE RADIANT GAS BROODER MODELS: SHP17B (-6) MODULATING INSTALLATION AND OPERATION INSTRUCTIONS OWNER/INSTALLER: For your safety this manual must be carefully read before installing, operating

More information

Mini-led spotlight with magnetic base

Mini-led spotlight with magnetic base Mini-led spotlight with magnetic base Model 95799 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission

More information

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK FIREPLACE HEATER FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK If you have any questions about the operation of your fireplace heater, please contact Crane Customer Care. Toll Free: 888-599-0992

More information

Voltmaster Trash Pumps Model TSP2, TSP3 and TSP4

Voltmaster Trash Pumps Model TSP2, TSP3 and TSP4 Model TSP2, TSP3 and TSP4 Owner s Manual July 2010 Table of Contents 1 Introduction...................................................... 1 1.1 Read before using..............................................

More information

VENT-FREE GAS LOG SET

VENT-FREE GAS LOG SET VENT-FREE GAS LOG SET MODEL # VFL-CO18DT VFL-MD18DT VFL-CO24DT WARNING: This appliance is equipped for (Natural and Propane) gas. Field conversion is not permitted other than between natural or propane

More information

ASK THE EXPERT: Burner Troubleshooting Information & Maintenance

ASK THE EXPERT: Burner Troubleshooting Information & Maintenance ASK THE EXPERT: Burner Troubleshooting Information & Maintenance The burner is the heart of your BBQ. It is subject to a number of conditions that can cause damage, and lead to potential safety issues.

More information

Owner s Manual PATIO HEATER

Owner s Manual PATIO HEATER RTA International For Evaluation Only Edited by Foxit PDF Editor Copyright (c) by Foxit Software Company, 2004 Owner s Manual PATIO HEATER TOLL FREE After Service Number 1-888-775-1330 IMPORTANT Read this

More information

PROPANE CONSTRUCTION HEATER

PROPANE CONSTRUCTION HEATER Dyna-Glo, Dyna-Glo Pro Dyna-Glo Delux PROPANE CONSTRUCTION HEATER USER S MANUAL AND OPERATING INSTRUCTIONS MODEL # RA18LPDG, RA18LPDGD, RA18LPDGP, RA18LPA, RA18LPB, and RA18LPC C US CSA 2.14b-2009, ANS

More information

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer

More information

ASX7-4-IOM-7 J30-08579

ASX7-4-IOM-7 J30-08579 INSTALLATION INSTRUCTIONS 4" COMBUSTION AIR INLET KIT TUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT HEATERS UNIT CONVERSION & CATEGORY III VENTING FOR SEPARATED COMBUSTION For 30,000 to 75,000 BTU/HR SUPPLEMENT

More information

http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html

http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html BURNER PROBLEM POSSBLE CAUSE(S) CORRECTVE ACTON WLL NOT GNTE 1. Pilot not tit Thermostat set too tow 3. Main burner line clogged Non-functioning

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

UNVENTED LP-GAS FIRED ROOM HEATER

UNVENTED LP-GAS FIRED ROOM HEATER Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference. INSTALLATION Instructions and Owner s Manual READ INSTRUCTIONS CAREFULLY: Read and follow all instructions.

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support

More information

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Condensing Water Heater Operation Manual Model NPE-180A/ 210A/ 240A NPE-180S/ 210S/ 240S * Lead Free Keep this manual near this water heater for future reference whenever maintenance or service is required.

More information

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary. INSTALLATION, OPERATING AND SERVICE MANUAL FOR EASY RADIANT WORKS HEATWAVE MODEL GH-25-40 GAS FIRED, VENTED INFRARED TUBE HEATER FOR RESIDENTIAL & COMMERCIAL / INDUSTRIAL APPLICATIONS. For Your Safety

More information

GNOME PELLET E.I. Pellet Heater Owner's Manual Installation and Operating Instructions. Please read this entire manual before installation.

GNOME PELLET E.I. Pellet Heater Owner's Manual Installation and Operating Instructions. Please read this entire manual before installation. Pellet Heater Owner's Manual Installation and Operating Instructions Please read this entire manual before installation. Save these instructions. SAFETY NOTICE HEATER MUST BE PROPERLY INSTALLED AND MAINTAINED

More information

AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM FOR NATURAL OR PROPANE GAS EPK-1 PILOT KITS

AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM FOR NATURAL OR PROPANE GAS EPK-1 PILOT KITS INSTALLATION & OWNER S MANUAL AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM FOR NATURAL OR PROPANE GAS Models: EPK-1(M)(P) FEATURES: INTERMITTENT PILOT IGNITION NON-STANDING FLAME-SENSING PILOT MANUAL

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries

More information

PREPIPED LIQUID FUEL MANIFOLDS PLPM

PREPIPED LIQUID FUEL MANIFOLDS PLPM PREPIPED LIQUID FUEL MANIFOLDS PLPM INSTRUCTIONS WARNING These instructions are intended for use only by experienced, qualified combustion start-up personnel. Adjustment of this equipment and its components,

More information

Assembly Instructions & User s Manual Triton Classic Gas & Charcoal Grill Model #: FSOGBG3005

Assembly Instructions & User s Manual Triton Classic Gas & Charcoal Grill Model #: FSOGBG3005 Assembly Instructions & User s Manual Triton Classic Gas & Charcoal Grill Model #: FSOGBG3005 Please keep this instruction manual for future reference Customer Service: (888) 922-2336, 7:00 am to 12:00

More information

30" GAS RANGE INSTALLATION INSTRUCTIONS (For Models with Sealed Top Burners)

30 GAS RANGE INSTALLATION INSTRUCTIONS (For Models with Sealed Top Burners) INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. If the information in this

More information

OBSOLETE. VS8420 Millivolt Gas Valve

OBSOLETE. VS8420 Millivolt Gas Valve APPLICATION The VS8420 Millivolt Gas Valve is compact and has a 60,000 Btuh capacity (1 in. pressure drop for straightthrough configuration). The design makes it ideal for fireplace and space heating applications.

More information

The growing popularity of Gas Fireplaces has created a demand for an ever increasing array of styles and sizes to fit every decor and budget.

The growing popularity of Gas Fireplaces has created a demand for an ever increasing array of styles and sizes to fit every decor and budget. Consumer Information Guide to Gas Fireplaces A Gas Fireplace gives you all the ambiance, warmth and comfort of a traditional wood-burning fireplace. They are convenient, easy to use and cost effective.

More information

Instantaneous gas water heater

Instantaneous gas water heater Instantaneous gas water heater Models W 125...T1 installation operation maintenance The Bosch instantaneous water heater is a high efficiency, space saving answer to your water heating needs. All Bosch

More information

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A. 04072 877-854-8006 * FAX (207) 283-8080

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A. 04072 877-854-8006 * FAX (207) 283-8080 Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A. 04072 877-854-8006 * FAX (207) 283-8080 FOR SERVICE ASSISTANCE U.S. AND CANADA CALL: 1-877-854-8006 24 HOURS/DAY 7 DAYS/WEEK TABLE OF CONTENTS

More information

USE AND CARE MANUAL FOR OUTDOOR USE ONLY MADE IN THE U.S.A.

USE AND CARE MANUAL FOR OUTDOOR USE ONLY MADE IN THE U.S.A. S o n o m a PLATINUM EDITION Sonoma Platinum Edition Grill: 27 Model TM USE AND CARE MANUAL FOR OUTDOOR USE ONLY MADE IN THE U.S.A. General Safety Instructions IMPORTANT SAFETY INFORMATION - Read this

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW, DOWNFLOW, UPFLOW/HORIZONTAL & HORIZONTAL ONLY INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this

More information

Installation and Operation Guide for PD5100 Automatic Transfer Switch

Installation and Operation Guide for PD5100 Automatic Transfer Switch Installation and Operation Guide for PD5100 Automatic Transfer Switch Member P r o gr e ssive Dynamics, Inc. 507 Industrial Rd Marshall, MI 49068 www.progressivedyn.com 2012 Progressive Dynamics, Inc.

More information

MODEL G300 BRAKE BLEEDER

MODEL G300 BRAKE BLEEDER MODEL G300 BRAKE BLEEDER Installation, Operation & Repair Parts Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV060616 P/N: 81-0035G 1 THIS PAGE INTENTIONALLY

More information

INSTALLATION MANUAL GAS COOKTOP. Please read this guide thoroughly before installation. www.lge.com. P/No.: MFL62725502

INSTALLATION MANUAL GAS COOKTOP. Please read this guide thoroughly before installation. www.lge.com. P/No.: MFL62725502 ENGL ISH ESPA ÑOL INSTALLATION MANUAL GAS COOKTOP Please read this guide thoroughly before installation. P/No.: MFL62725502 www.lge.com READ ALL INSTRUCTIONS BEFORE INSTALLATION IN THE COMMONWEALTH OF

More information

Crux TM. Canister mounted stove for outdoor use SWE OPTIMUS CLEVER COOKING SINCE 1899

Crux TM. Canister mounted stove for outdoor use SWE OPTIMUS CLEVER COOKING SINCE 1899 EN Crux TM Canister mounted stove for outdoor use FR DE NL DK SWE NO FI IT ES PT PL CZ OPTIMUS CLEVER COOKING SINCE 1899 RU FIGURE [1] FIGURE [2] O-ring Art. No. 8017867 FIGURE [3] FIGURE [4] FIGURE [5]

More information

Installation Instructions for Alarm Module Kit A043F059

Installation Instructions for Alarm Module Kit A043F059 Instruction Sheet 07-2013 Installation Instructions for Alarm Module Kit A043F059 1 Introduction The information contained within is based on information available at the time of going to print. In line

More information

Instruction Manual for Residential Gas Water Heaters

Instruction Manual for Residential Gas Water Heaters Instruction Manual for Residential Gas Water Heaters NOT FOR USE IN MANUFACTURED (MOBILE) HOMES GAMA certification applies to all residential gas water heaters with capacities of 20 to 100 gallons with

More information

3 WATT LED SPOTLIGHT Model No. SLM - 3801

3 WATT LED SPOTLIGHT Model No. SLM - 3801 3 WATT LED SPOTLIGHT Model No. SLM - 3801 OWNER'S MANUAL Customer Service Tel: 1-800-268-3319 Superex Canada Ltd, Toronto,M2H 3B8 Made in China Table of Contents A). Important Safety Instructions B). Charging

More information

WARNING: FOR OUTDOOR USE ONLY

WARNING: FOR OUTDOOR USE ONLY Select Models Certified to ANSI Z21.97-2014 CSA 2.41-2014 FPPK Fire Pit Insert Installation & Operation Instructions Installation We suggest that our products be installed by professionals that are locally

More information

Installation Operation & Maintenance Manual

Installation Operation & Maintenance Manual www.montigo.com Operation & Maintenance Manual Check local codes and read all instructions prior to installation. EDVPV BF-Series Wall SS Power Gas Fireplace Vent System EDVPV47 EDVPV58 Warning: Improper

More information

30" GAS RANGE INSTALLATION INSTRUCTIONS (For Models with Sealed Top Burners)

30 GAS RANGE INSTALLATION INSTRUCTIONS (For Models with Sealed Top Burners) INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. If the information in this

More information

Gas-Fired, Residential Storage Type Water Heaters

Gas-Fired, Residential Storage Type Water Heaters Consulting, Resource, Education, Training, and Support Services for Home Inspectors A candle loses no light when it lights another candle. Gas-Fired, Residential Storage Type Water Heaters Most inspectors

More information

DBF 4XL Dryer Booster Fans

DBF 4XL Dryer Booster Fans Installation and Operation Manual Item #: 401315 Rev Date: 121514 DBF 4XL Dryer Booster Fans DBF4XL Kit Includes: Dryer Booster Fan, 1 pc Fan Mounting Bracket and Hardware, 1 pc Wall Label (Mount on wasll

More information

OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608

OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions

More information

OTF Oil Fired Pool Heater

OTF Oil Fired Pool Heater OTF Oil Fired Pool Heater Installation Operation Maintenance Manual Service Policy 722010 Congratulations on the purchase of your new pool heater. In order to maintain peak performance of your pool heater

More information

TANKLESS WATER HEATER USE AND CARE MANUAL

TANKLESS WATER HEATER USE AND CARE MANUAL WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result, causing death, personal injury, or property damage. For Your Safety! Do not store or use gasoline

More information

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions FJ2 2 Ton Trolley Floor Jack Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper operation & maintenance.

More information

RESIDENTIAL GAS WATER HEATERS

RESIDENTIAL GAS WATER HEATERS Instruction Manual RESIDENTIAL GAS WATER HEATERS NOT FOR USE IN MANUFACTURED (MOBILE) HOMES For Your Safety AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER. ALL TECHNICAL AND WARRANTY QUESTIONS:

More information

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The

More information

Firewall. Propane flame projector Safety instructions and operating manual

Firewall. Propane flame projector Safety instructions and operating manual Firewall Propane flame projector Safety instructions and operating manual TBF-PyroTec GmbH Lichterfelder Str. 5A 21502 Geesthacht Tel.: +49(0)4152 157 9950 info@tbf-pyrotec.de www.tbf-pyrotec.de 1 Flame

More information

Ceiling Mount Air Handler Manual

Ceiling Mount Air Handler Manual www.surna.com 303.993.5271 Ceiling Mount Air Handler Manual Models: CMAH12, CMAH18, CMAH24, CMAH30, CMAH36, CMAH48, CMAH60 Revised: September 2014 Table of Contents Warranty Information 4 Limited Warranty

More information

Table of Contents. www.hunterfan.com. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Table of Contents. www.hunterfan.com. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing. www.hunterfan.com Table of Contents What to Expect with Your Installation 30 inches Hanging the Fan Wiring 8 Maintenance, Operation & Cleaning Light Kit 13??? 14 1 9 Troubleshooting 11 5 Blades Motor Housing

More information

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS PRODUCT LITERATURE 1997 Lennox Industries Inc. Dallas, Texas INSTALLATION INSTRUCTIONS GAS UNITS 503,560M 2/97 Supersedes 11/96 TABLE OF CONTENTS UNIT DIMENSIONS................................ 2 PARTS

More information

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model # 900172

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model # 900172 Model # 900172: Page 1 USER MANUAL Bottom Loading Bottled Water Dispenser Model # 900172 TO REDUCE THE RISK OF INJURY AND PROPERTY DAMAGE, USER MUST READ THIS MANUAL BEFORE ASSEMBLING, INSTALLING & OPERATING

More information

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents

More information

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE

More information

INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE

INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. If the information in this

More information