Electric Actuator AE-80 Double Acting Nema 4x anual Override.07 4.6 AE-80 Features Hard anodized aluminum hosing with external powder coating for severe duty applications Enclosure: IP67 ISO 5 mounting 90 operation Position indicator anual override standard 0V / Ph / 60Hz Thermally protected induction motor.44 Actuator Specs Torque (in-lbs) 80 Output Square 0.4 ISO 5 ounting Duty Cycle 50% Operating Time, 90 @ 0V (secs) 5 Rated current @ 0V (Amp.) 0.A otor Insulation Class Weight (lbs).64 Limit Switches Cable Entry Internal Htr. Temperature Range F0 / F04 / F05 E - ea for & (5A, 50VAC) PIGTAIL - F to 40 F.44.44.8.4 4-6 8-5 Ø.4 Ø.97 Ø.65 See next page for wiring diagram Jomar Valve 74 iller Drive, Warren, I 4809 www.jomarvalve.com phone: (586) 68-0 fax: (586) 979-85 0485
Electric Actuator AE-80 Wiring Diagram PE Y&G Grey Brown White Full- Signal Full- Signal C OLS CLS Black Red K L Blue N 0485 Jomar Valve 74 iller Drive, Warren, I 4809 www.jomarvalve.com phone: (586) 68-0 fax: (586) 979-85
Electric Actuator AE-80 Double Acting Nema 4x anual Override.07 4.6 AE-80 Features Hard anodized aluminum hosing with external powder coating for severe duty applications Enclosure: IP67 ISO 5 mounting 90 operation Position indicator anual override standard 0V / Ph / 60Hz Thermally protected induction motor.44 Actuator Specs Torque (in-lbs) 80 Output Square 0.4 ISO 5 ounting Duty Cycle 50% Operating Time, 90 @ 0V (secs) 5 Rated current @ 0V (Amp.) 0.A otor Insulation Class Weight (lbs).64 Limit Switches Cable Entry Internal Htr. Temperature Range F0 / F04 / F05 E - ea for & (5A, 50VAC) PIGTAIL - F to 40 F.44.44.8.4 4-6 8-5 Ø.4 Ø.97 Ø.65 See next page for wiring diagram Jomar Valve 74 iller Drive, Warren, I 4809 www.jomarvalve.com phone: (586) 68-0 fax: (586) 979-85 0485
Electric Actuator AE-80 Wiring Diagram PE Y&G Grey Brown White Full- Signal Full- Signal C OLS CLS Black Red K L Blue N 0485 Jomar Valve 74 iller Drive, Warren, I 4809 www.jomarvalve.com phone: (586) 68-0 fax: (586) 979-85
Electric Actuator AE-50 Double Acting Nema 4x anual Override 4.08 AE-50 Features Hard anodized aluminum hosing with external powder coating for severe duty applications Enclosure: IP66, O-ring sealed ISO 5 mounting 90 operation Position indicator anual override standard 0V / Ph / 60Hz Thermally protected induction motor Spring loaded terminal block for ease in wiring 5.08 4.49 4.96 Actuator Specs Torque (in-lbs) 50 Output Square 0.55 ISO 5 ounting IEC Duty Cycle (S) Operating Time, 90 @ 0V (secs) Rated current @ 0V (Amp.) 0.7A otor Insulation Class Weight (lbs) 6.6 Limit Switches Auxiliary Limit Switches F0 / F05 / F07 ax 0 min Cable Entry - PG.5 Internal Htr. Temperature Range E - ea for & (A, 50VAC) - ea for & (A, 50VAC) Yes - 5W -4 F to 58 F 4-8 0.55 4-6 4-5 0.5.4.97.76 See next page for wiring diagram Jomar Valve 74 iller Drive, Warren, I 4809 www.jomarvalve.com phone: (586) 68-0 fax: (586) 979-85 0485
Electric Actuator AE-50 Wiring Diagram Incoming Power AC PH ( V) Proposed Customer s Wiring Actuator Wiring Lamp Lamp Stop Aux. ACLS Aux. AOLS Neutral Live C 0 Aux. Com 4 5 6 7 8 9 0 G/F TP Option Condenser G/F ACLS AOLS BRO Base Earth TP Heater CLS OLS 0485 Jomar Valve 74 iller Drive, Warren, I 4809 www.jomarvalve.com phone: (586) 68-0 fax: (586) 979-85
Electric Actuator AE-450 Double Acting Nema 4x anual Override 6.0.7.0 4.04 AE-450 Features Hard anodized aluminum hosing with external powder coating for severe duty applications Enclosure: IP67 ISO 5 mounting 90 operation Position indicator anual override standard 0V / Ph / 60Hz Thermally protected induction motor Set screw terminal block 4-8 4-5.55 4-6.75.8 Actuator Specs Torque (in-lbs) 450 Output Square 0.55 ISO 5 ounting Duty Cycle 0% Operating Time, 90 @ 0V (secs) 0 Rated current @ 0V (Amp.) 0.4A otor Insulation Class E Weight (lbs) 4.4 Limit Switches F0 / F05 / F07 Cable Entry - G/ Internal Htr. Temperature Range - ea for & (5A, 50VAC) - F to 40 F.4.97.76 See next page for wiring diagram Jomar Valve 74 iller Drive, Warren, I 4809 www.jomarvalve.com phone: (586) 68-0 fax: (586) 979-85 0485
Electric Actuator AE-450 Wiring Diagram PE Y & G 7 6 Brown Grey 5 4 Full- Signal Full- Signal C OLS CLS Black Red K L Blue N PE 0485 Jomar Valve 74 iller Drive, Warren, I 4809 www.jomarvalve.com phone: (586) 68-0 fax: (586) 979-85
Electric Actuator AE-700 Double Acting Nema 4x anual Override Note:.5 of clearance needed to remove cover 4.65 AE-700 Features Hard anodized aluminum hosing with external powder coating for severe duty applications Enclosure: IP67, O-ring sealed ISO 5 mounting 90 operation Adjustable mechancial stops to prevent over travel Position indicator anual override standard 0V / Ph / 60Hz Thermally protected induction motor Worm gearing, no break required Spring loaded terminal block for ease in wiring.6.68 6.0.98 Actuator Specs Torque (in-lbs) 700 Output Square 0.67 ISO 5 ounting IEC Duty Cycle (S) IEC Duty Cycle (S4) Operating Time, 90 @ 0V (secs) 4 F05 / F07 Rated current @ 0V (Amp.) 0.97A otor Insulation Class Weight (lbs) 7.7 Limit Switches Auxiliary Limit Switches Cable Entry Internal Htr. Temperature Range ax 0 min 50%,,00 start/hr E - ea for & (A, 50VAC) - ea for & (A, 50VAC) - /4" NPT Yes - W -4 F to 58 F 4-8.67 4-6.7.05 4.76.97.76 See next page for wiring diagram Jomar Valve 74 iller Drive, Warren, I 4809 www.jomarvalve.com phone: (586) 68-0 fax: (586) 979-85 0485
Electric Actuator AE-700 Wiring Diagram Incoming Power AC PH (0V) Neutral Live Aux. Full 50VAC,A Aux. Full 50VAC,A Proposed Customer s Wiring Actuator Wiring Lamp C 0 Lamp Stop 4 5 6 7 8 9 0 5 6 7 8 YEL TP ACLS AOLS Capacitor Option Base Earth TP G/F G/F Heater CLS OLS 0485 Jomar Valve 74 iller Drive, Warren, I 4809 www.jomarvalve.com phone: (586) 68-0 fax: (586) 979-85
Electric Actuator AE-700 Double Acting Nema 4x odulating anual Override Note:.5 of clearance needed to remove cover 4.69.98 AE-700 4.09 7.48.9 Features Hard anodized aluminum hosing with external powder coating for severe duty applications Enclosure: IP67, O-ring sealed ISO 5 mounting Remote Position Contoller (RPC) modulation 90 operation Adjustable mechancial stops to prevent over travel Auto Calibration Position indicator anual override standard 0V / Ph / 60Hz Thermally protected induction motor Worm gearing, no break required Spring loaded terminal block for ease in wiring 4.7.9 7.56 Actuator Specs Torque (in-lbs) 700 Output Square 0.67 ISO 5 ounting F05 / F07 IEC Duty Cycle (S) ax 0 min IEC Duty Cycle (S4) 50%,,00 start/hr Operating Time, 90 @ 0V (secs) 4 Rated current @ 0V (Amp.) 0.97A otor Insulation Class E Weight (lbs) 7.7 Limit Switches - ea for & (A, 50VAC) Auxiliary Limit Switches - ea for & (A, 50VAC) Cable Entry /4" NPT Internal Htr. Yes - W Temperature Range 0 F to 50 F Input Signal Output Signal 4-6 4-8 Jomar Valve 74 iller Drive, Warren, I 4809 www.jomarvalve.com phone: (586) 68-0 fax: (586) 979-85 0485.67 Potentiometer (Feedback) Load Resistance Input Resistance Delay Time Adjustment RPC Specifications.47.76 4-0mA, 0-0VDC, -0VDC, -5VDC, 0-5VDC 4-0mA Kohm 00 Ohm - 750 Ohm 50 Ohms.0-8.5 sec Dead Band Adjustment 0. - 4.5% Resolution in /,000 See next page for wiring diagram
Electric Actuator AE-700 Wiring Diagram Incoming Power AC PH (0V) Proposed Customer s Wiring Actuator Wiring NEUTRAL 4 5 LIVE CLOSE LAP C 0 OPEN LAP OPEN STOP CLOSE 6 7 8 9 0 5 6 7 8 9 0 Aux. Full ANU AUTO 50VAC, A Aux. Full 50VAC, A Input Signal Position Indicator + - + - TP ACLS AOLS Base Earth Capacitor TP Option G/F Heater G/F CLS OLS GRY 5 4 POWER OPEN CLOSE + IN - + - OUT P P P Remote Position Controller (RPC) GRY ORA YEL BRO GRY Feed Back Potentiometer 0485 Jomar Valve 74 iller Drive, Warren, I 4809 www.jomarvalve.com phone: (586) 68-0 fax: (586) 979-85
Electric Actuator AE-880 Double Acting Nema 4x anual Override Note: 5 of clearance needed to remove cover 0.6.85 6.0.0.6 AE-880 Features Hard anodized aluminum hosing with external powder coating for severe duty applications Enclosure: IP67, NEA4 and 4X, O-ring sealed ISO 5 mounting 90 operation Adjustable mechancial stops to prevent over travel Position indicator De-clutchable manual override standard 0V / Ph / 60Hz Thermally protected induction motor Double worm gearing, no break required Spring loaded terminal block for ease in wiring Actuator Specs Torque (in-lbs) 880 Output Square 0.67 ISO 5 ounting F07 IEC Duty Cycle (S) ax 0 min IEC Duty Cycle (S4) 0%, 800 start/hr Operating Time, 90 @ 0V (secs) 8.57.46 6.77 4.0.76.57 7.56 9.65 Rated current @ 0V (Amp.) (Running/ax).0/.49 otor Insulation Class F Weight (lbs) 5.4 Limit Switches - ea for & (0A, 50VAC) Auxiliary Limit Switches - ea for & (0A, 50VAC) Cable Entry - /4" NPT Internal Htr. Yes - 5W Temperature Range -4 F to 58 F Torque OL Protection.67 4-8 Ø.76.09 See next page for wiring diagram Jomar Valve 74 iller Drive, Warren, I 4809 www.jomarvalve.com phone: (586) 68-0 fax: (586) 979-85 0485
Electric Actuator AE-880 Wiring Diagram Incoming Power AC PH (0V) Neutral Live Dry Contact (50VAC, 0A) Proposed Customer s Wiring Actuator Wiring Lamp C 0 Lamp Stop AUX. ACLS AUX. AOLS AUX. 4 5 6 7 8 9 0 TP Option TP ACLS AOLS G/F Capacitor G/F Heater BRO Base Earth CLS OLS 0485 Jomar Valve 74 iller Drive, Warren, I 4809 www.jomarvalve.com phone: (586) 68-0 fax: (586) 979-85
Electric Actuator AE-880 Double Acting Nema 4x odulating anual Override Note: 5 of clearance needed to remove cover.9..85 6.0.0 4.7 AE-880 Features Hard anodized aluminum hosing with external powder coating for severe duty applications Enclosure: IP67, NEA4 and 4X, O-ring sealed ISO 5 mounting 90 operation Adjustable mechancial stops to prevent over travel Position indicator De-clutchable manual override standard 0V / Ph / 60Hz Thermally protected induction motor Double worm gearing, no break required Spring loaded terminal block for ease in wiring Actuator Specs Torque (in-lbs) 880 Output Square 0.67 ISO 5 ounting F07 IEC Duty Cycle (S) ax 0 min IEC Duty Cycle (S4) 0%, 800 start/hr Operating Time, 90 @ 0V (secs) 8 Rated current @ 0V (Amp.) (Running/ax).0/.49 otor Insulation Class F Weight (lbs) 5.4 Limit Switches - ea for & (0A, 50VAC) Auxiliary Limit Switches - ea for & (0A, 50VAC) Cable Entry - /4" NPT Internal Htr. Yes - 5W Temperature Range 0 F to 50 F Torque OL Protection.46 7.48 6.77 4.0.76 Jomar Valve 74 iller Drive, Warren, I 4809 www.jomarvalve.com phone: (586) 68-0 fax: (586) 979-85 0485.6.57.67.57 4-8 Ø.76 7.56.09 9.65 RPC Specifications Input Signal 4-0mA, 0-0VDC, -0VDC, -5VDC, 0-5VDC Output Signal 4-0mA Potentiometer (Feedback) Kohm Load Resistance 00 Ohm - 750 Ohm Input Resistance 50 Ohms Delay Time Adjustment.0-8.5 sec Dead Band Adjustment 0. - 4.5% Resolution in /,000 See next page for wiring diagram
Electric Actuator AE-880 Wiring Diagram Incoming Power AC PH (0V) ANU Neutral Live AUTO Dry Contact (50VAC, 0A) Input Signal Position Indicator Proposed Customer s Wiring Actuator Wiring Lamp C 0 Lamp Stop 4 5 6 7 8 9 0 AUX. ACLS AUX. AOLS AUX. + - + - 4 Option TP TP GRY ACLS AOLS Base Earth G/F G/F Heater CLS Capacitor BRO OLS GRY 5 + - + - 4 Power IN Remote Position Controller (RPC) P OUT P P GRY ORA Feed Back Potentiometer 0485 Jomar Valve 74 iller Drive, Warren, I 4809 www.jomarvalve.com phone: (586) 68-0 fax: (586) 979-85
Electric Actuator AE-400-9700 Double Acting Nema 4x anual Override Note: 7.68 of clearance needed to remove cover B A C D E AE-400-9700 Features Hard anodized aluminum hosing with external powder coating for severe duty applications Enclosure: IP67, NEA4 and 4X, O-ring sealed ISO 5 mounting 90 operation Adjustable mechancial stops to prevent over travel Position indicator De-clutchable manual override standard 0V / Ph / 60Hz Thermally protected induction motor Double worm gearing, no break required Spring loaded terminal block for ease in wiring Actuator Specs AE-400 AE-00 AE-00 AE-4400 AE-7000 AE-9700 Torque (in-lbs) 400 00 00 4400 7000 9700 Output Square 0.87.06.4.54 ISO 5 ounting F07 / F0 F0 / F F / F4 IEC Duty Cycle (S) ax 0 min ax 0 min IEC Duty Cycle (S4) 50%, 00 start/hr 0%, 800 start/hr Operating Time, 90 @ 0V (secs) Rated current @ 0V (Amp.) (Running/ax) 6.70/.6.7/.6.80/.6.9/5.44 4./7.9 4./7.9 otor Insulation Class F Weight (lbs) 44 55 Limit Switches x SPDT - ea for & (0A, 50VAC) Auxiliary Limit Switches x SPDT - ea for & (0A, 50VAC) Cable Entry - /4" NPT Internal Htr. Yes - 5W Temperature Range -4 F to 58 F Torque OL Protection x SPDT - ea for & (0A, 50VAC) F R V T G ØS J ØU H L V T R K N ØS ØU P AE-400 - AE-4400 AE-7000 - AE9700 See next page for dimensions and wiring diagram Jomar Valve 74 iller Drive, Warren, I 4809 www.jomarvalve.com phone: (586) 68-0 fax: (586) 979-85 0485
Electric Actuator AE-400-9700 Dimensions and Wiring Diagram (400) Proposed Customer s Wiring Actuator Wiring Incoming Power AC PH (0V) Neutral Live Dimensions Actuator A B C D E F G H J K L N P R S T U V AE-400..99 7.76.56.07.6 4.9 9.0 5.7..4 8.54.64.8 4-8 F07 4-0 F0 0.87 AE-00..99 7.76.56.07.6 4.9 9.0 5.7..4 8.54.64.8 4-8 F07 4-0 F0 0.87 AE-00 4.06.07 8.4.56.54.56 5.8 9.45 6.0..64 9.65.68. 4-0 F0 4- F.06 AE-4400 4.06.07 8.4.56.54.56 5.8 9.45 6.0..64 9.65.68. 4-0 F0 4- F.06 AE-7000 4.96.46 8.94.56 4..76 7.0.8 7.05 4..9 0.4.87. 4- F 4-6 F4.4 AE-9700 4.96.46 8.94.56 4..76 7.0.8 7.05 4..9 0.4.87. 4- F 4-6 F4.54 OT C 0 Over Torque Lamp Lamp Lamp Stop Aux. Full 50VAC, 0A Aux. Full 50VAC, 0A 4 5 6 7 8 9 0 4 5 6 7 8 YEL G/F Capacitor TP CTS BRO OTS ACLS AOLS Option Base Earth TP G/F G/F Heater CLS OLS 0485 Jomar Valve 74 iller Drive, Warren, I 4809 www.jomarvalve.com phone: (586) 68-0 fax: (586) 979-85