Overview of the DEP 216/256 Input Module

Similar documents
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

DLP-PU/E Instruction Manual

Modular I/O System Analog and Digital Interface Modules

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Allen-Bradley/Rockwell

CompactLogix Power Supplies Specifications

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

40.3. Control Relays and Timers

THE INPUT/OUTPUT SYSTEM. Key Points

Model SPDT Relays

WD-AMX Water Detection Controllers

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

AC-DC Converter Application Guidelines

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

Digital Expansion Modules Specifications

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

AutoRanging Digital MultiMeter

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

MINI MCR-SL-R-UI(-SP)

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Power Supplies 3. SDN-P DIN Rail Series

HM-W536 Install Guide

Manual Ranging MultiMeter

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

GST301. (Single Protection Zone) Operation Manual

38 Series - Relay interface modules A

38 Series - Relay interface modules A

ADM1TE 5/30A DIN rail single phase two wire energy meter

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

RM4TG20 three-phase network control relay RM4-T - range V

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

S-series Mass Connection Solutions

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

650W Single Output Power Supply

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

Rosemount 333 HART Tri-Loop

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Digital input modules

Top Microsystems Proprietary Specification P/N: W090015HK-XP RB V.A0 SPECIFICATION

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Safety automation solutions

Cross-beam scanning system to detect slim objects. 100 mm in

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

T7560A,B,C Digital Wall Module

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

Operating Instructions. UL325 Compliant Non-monitored

Contents. Document information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

Energy Management Energy Meter Type EM23 DIN

Rosemount 333 HART Tri-Loop

Model 1756 Test Lead Kit

2002 IS Catalog. Page

Radiant Temperature Sensor TY7321

MCR1900 Media Converter 19-Slot Chassis

Optocoupler, Phototransistor Output, with Base Connection

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

FEMA ELECTRÓNICA. Serie ISC SIGNAL CONVERTERS WITH GALVANIC ISOLATION. MODEL ISC-IAC for AC Currents ISC-IDC for DC Currents USER S MANUAL

SAFETY MANUAL SIL Switch Amplifier

Optocoupler, Phototransistor Output, with Base Connection

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

7-41 POWER FACTOR CORRECTION

Safety technique. Emergency stop module BO 5988 safemaster

Optocoupler, Phototransistor Output, with Base Connection

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

Inductive Proximity Sensors

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

NX safety stand-alone

Pluggable interface relays CR-P Pcb relays

STRATO LED Drivers 70W, Single output

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

For a complete explanation of all the functions and configurations available please refer to the SC6006: Manual of operation.

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

Arc Flash Avoidance and its Application to Overhead Traveling Cranes

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

User's Guide. True RMS Industrial Multimeter

DUCT SMOKE DETECTOR D4120

1756 ControlLogix I/O Specifications

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

48 SERIES Relay interface modules 10 A

Control Devices Catalogue. Control Devices. Preferred and Standard Products

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Transcription:

Overview of the DEP 216/256 Input Module At a Glance Purpose What s in this Chapter? The purpose of this chapter is to describe the DEP 216/256 input module. This chapter contains the following topics: Topic Page What is the DEP 216/256 Input Module? 432 DEP 216/256 Input Module LEDs 433 DEP 216/256 Input Module Field Wiring 434 DEP 216/256 Input Module Specifications 435 890 USE 109 00 March 2003 431

DEP 216/256 Input Module What is the DEP 216/256 Input Module? Brief Product Description The DEP 216/256 is a 24 Vdc, 16-point discrete input module. It senses input signals received from field sensing devices such as pushbuttons, limit and proximity switches, or other 24 Vdc input sources and converts those signals into logic voltage levels that can be used by the PLC. Signals are field wired in two groups, eight signals per group. Inputs are opto-isolated from the system bus. The DEP 256 functions just like the DEP 216 except that the DEP 256 operates at extended temperature. Note: The DEP 256 model is available with conformal coating. The conformal coating model is DEP 256C and it meets Railway standard EN 50 155. 432 890 USE 109 00 March 2003

DEP 216/256 Input Module DEP 216/256 Input Module LEDs LEDs The DEP 216/256 module has two green LEDs, opposite terminal screws 1 and 12. When one of these LEDs is ON, it indicates that power is available to the eight inputs directly below it. The module also has 16 red LEDs, eight opposite terminal screws 3... 10 and eight opposite terminal screws 14... 21; when any one of these LEDs are ON, it indicates voltage present at the corresponding input. 890 USE 109 00 March 2003 433

DEP 216/256 Input Module DEP 216/256 Input Module Field Wiring Introduction The DEP 216/256 is a 24 Vdc, 16-point discrete input module. It senses input signals received from field sensing devices such as pushbuttons, limit and proximity switches, or other 24 Vdc input sources and converts those signals into logic voltage levels that can be used by the PLC. Signals are field wired in two groups, eight signals per group. Inputs are opto-isolated from the system bus. The DEP 256 functions just like the DEP 216 except that the DEP 256 operates at extended temperature. Simplified Schematic for DEP 216/256 24 Vdc 24 V Common A simplified schematic for the DEP 216/256 input module is provided below. 0.16A In1 In2 In3 In4 In5 In6 In7 In8 In9 In10 In11 In12 In13 In14 In15 In16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Green Red Opto Coupler I/O Bus Interface 5 V First of 16 Input Circuits GND 434 890 USE 109 00 March 2003

DEP 216/256 Input Module DEP 216/256 Input Module Specifications Table of Specifications for DEP 216/256 The following table contains DEP 216/256 input module specifications. Module Topology Power Supplies Number of Inputs 16 Number of Groups 2 Points/group 8 Isolation Optocoupler on each input External Source Requirement Rated Signal Value Internally Provided Source from I/O bus Internal Power Dissipation Electrical ON State Signal Level Characteristics Environmental Characteristics 24 Vdc for eight inputs 24 Vdc +25 percent/-15 percent 5 V; 15 ma 2 W typical 12... 30 Vdc OFF State Signal Level -2... +5 Vdc ON State Input Current 7 ma @ 24 Vdc 8.5 ma @ 30 Vdc Response Time 4 ms typical Operating Mode True High Wire Size/terminal One wire 14 AWG Two wires 20 AWG Operating Temperature 0... 60 degrees C for DEP216-40... +70 degrees C for DEP256 I/O Map Discrete 1x/0x 16 in/0 out Dimensions W x H x D 40.3 x 145 x 117.5 mm 1.6 x 5.6 x 4.5 in Weight 220 g 0.5 lb Agency Approvals DEP216: VDE 0160; UL 508; CSA 22.2 No.142; and FM Class I, Div 2 Standards. DEP256C: Railway standard EN 50 155; European Directive EMC 89/336/ EEC. UL 508; CSA 22.2 No.142; and FM Class I, Div 2 pending. 890 USE 109 00 March 2003 435

DEP 216/256 Input Module 436 890 USE 109 00 March 2003

Overview of the DEP 217 Input Module At a Glance Purpose What s in this Chapter? The purpose of this chapter is to describe the DEP 217 input module. This chapter contains the following topics: Topic Page What is the DEP 217 Input Module? 438 DEP 217 Input Module LEDs 439 DEP 217 Input Module Field Wiring 440 DEP 217 Input Module Specifications 441 890 USE 109 00 March 2003 437

DEP 217 Input Module What is the DEP 217 Input Module? Brief Product Description Note: Some A120 I/O modules (DEP 211/214/215/217, DAP211/217, ADU204/ 211/214/216, DAU204, VIC2xx, and MOT20x) require a loadable (SW-IODR-001) for proper operation when using certain PLCs (A984-1xx, E984-24x/251/255) with Modsoft. The DEP 217 is a 24 Vdc, 16-point discrete true low input module. It senses levels provided by field devices such as pushbuttons, limit and proximity switches, or other 24 Vdc input sources and converts those signals into logic voltage levels that can be used by the PLC. Signals are field wired in two groups, eight signals/group. Inputs are opto-isolated from the system bus. Note: The DEP 217 is a true low module; therefore, a high (greater than or equal to external source minus 6Vdc) is read by the PLC as a logic 0. Conversely, a low (less than or equal to external source minus 12Vdc) is read by the PLC as a logic 1. 438 890 USE 109 00 March 2003

DEP 217 Input Module DEP 217 Input Module LEDs LEDs The DEP 217 module has two green LEDs, opposite terminal screws 1 and 12. When one of these LEDs is ON, it indicates that power is available to the group directly below it. The module also has 16 red LEDs, eight opposite terminal screws 3... 10 and eight opposite terminal screws 14... 21; when any one of these LEDs are ON, it indicates 3 external source minus 12 V at the corresponding input. 890 USE 109 00 March 2003 439

DEP 217 Input Module DEP 217 Input Module Field Wiring Introduction The DEP 217 is a 24 Vdc, 16-point discrete true low input module. It senses levels provided by field devices such as pushbuttons, limit and proximity switches, or other 24 Vdc input sources and converts those signals into logic voltage levels that can be used by the PLC. Signals are field wired in two groups, eight signals/group. Inputs are opto-isolated from the system bus. Note: The DEP 217 is a true low module; therefore, a high (greater than or equal to external source minus 6Vdc) is read by the PLC as a logic 0. Conversely, a low (less than or equal to external source minus 12Vdc) is read by the PLC as a logic 1. Wiring Diagram and Simplified Schematic for DEP 217 24 Vdc 24 V Common A wiring diagram and simplified schematic for the DEP 217 input module is provided below. 0.16 A In1 In2 In3 In4 In5 In6 In7 In8 In9 In10 In11 In12 In13 In14 In15 In16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Red First of 16 Input Circuits Green 5 V GND I/O Bus Interface 440 890 USE 109 00 March 2003

DEP 217 Input Module DEP 217 Input Module Specifications Table of Specifications for DEP 217 The following table contains DEP 217 input module specifications. Module Topology Number of Inputs 16 Number of Groups 2 Points/group 8 Isolation Optocoupler on each input Required Loadable SW-IODR-001 (See Requirements for CE Compliance, p. 779) Power Supplies External Source Requirement 24 Vdc for eight inputs Rated Signal Value Sinking device Internally Provided Source from I/O bus 5 V; 25 ma Electrical Characteristics Internal Power Dissipation False Condition Signal Level True Condition Signal Level 3 W typical greater than or equal to external source minus 6 Vdc less than or equal to external source minus 12 Vdc 7 ma @ 0 Vdc 4 ms typical True Low True Condition Input Current Response Time Operating Mode Wire Size/ One wire 14 AWG terminal Two wires 20 AWG I/O Map Discrete 1x/0x 16 in/0 out Dimensions W x H x D 40.3 x 145 x 117.5 mm 1.6 x 5.6 x 4.5 in Weight 220 g 0.5 lb. Agency Approvals VDE 0160; UL 508; and CSA 22.2 No.142 Standards 890 USE 109 00 March 2003 441

DEP 217 Input Module 442 890 USE 109 00 March 2003

Overview of the DEP 218 Input Module At a Glance Purpose What s in this Chapter? The purpose of this chapter is to describe the DEP 218 input module. This chapter contains the following topics: Topic Page What is the DEP 218 Input Module? 444 DEP 218 Input Module LEDs 445 DEP 218 Input Module Field Wiring 446 DEP 218 Input Module Specifications 448 890 USE 109 00 March 2003 443

DEP 218 Input Module What is the DEP 218 Input Module? Brief Product Description WARNING Operational Hazard The DEP 218 module will only operate properly when used with an A984, E984, or Micro 512/612 controller. Failure to follow this precaution can result in death, serious injury, or equipment damage. The DEP 218 is a 115 Vac, 16-point input module with 1.8kV isolation between field devices and the bus. It senses input signals received from field sensing devices such as pushbuttons, limit and proximity switches, or other 115 Vac input sources and converts those signals into logic voltage levels that can be used by the controller. Signals are field wired in two groups, eight signals/group. Inputs are optoisolated from the system bus. Note: The DEP 218 is designed for capacitive loads. Without any discharge bypass resistor. When using field devices with resistive loads you should use 120K 1/4 Watt resistors (approximately) across the input terminals of the DEP 218. This allows accurate switching of phase firing type solid state sensors by ensuring that the capacitor discharges within the sensor required 50 milliseconds. If your application permits, a DEP 210 may be substituted for the DEP 218. The DEP 210 has an internal input discharge circuit. 444 890 USE 109 00 March 2003

DEP 218 Input Module DEP 218 Input Module LEDs LEDs The DEP 218 module has one green LED opposite terminal screw 1. When this LED is ON, it indicates the presence of working voltage from the power supply. The module also has 16 red LEDs, eight opposite terminal screws 3... 10 and eight opposite terminal screws 14... 21; when any one of these LEDs is ON, it indicates voltage present at the corresponding input. A front view and fill-in labels of the DEP 218 module is provided below. DEP 218 DEP 218 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 22 18 19 20 21 ready N 1 2 3 4 5 6 7 8 N N 9 10 11 12 13 14 15 16 N card 890 USE 109 00 March 2003 445

DEP 218 Input Module DEP 218 Input Module Field Wiring Wiring Diagram for DEP 218 A sample wiring diagram for the DEP 218 input module is provided below. ac Neutral ac Hot ac Hot ac Neutral 0.16 A 0.16 A 1 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 Input 8 Input 9 Input 10 Input 11 Input 12 Input 13 Input 14 Input 15 Input 16 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 446 890 USE 109 00 March 2003

DEP 218 Input Module Simplified Schematic for DEP 218 A simplified schematic for the DEP 218 input module is provided below. ac Neutral 1 2 3 FIRST OF 16 INPUT CIRCUITS 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Red 5 V Green 0 V PAB 890 USE 109 00 March 2003 447

DEP 218 Input Module DEP 218 Input Module Specifications Table of Specifications for DEP 218 The following table contains DEP 218 input module specifications. Module Number of Inputs 16 Topology Number of Groups 2 Points/group 8 Isolation Optocoupler on each input point, 1.8 kv field-to-bus Power Supplies External Source Requirement 115 Vac Rated Signal Value 115 Vac 47... 65 Hz Internally Provided Source from the I/O bus 5 V, less tghan 50 ma Internal Power Dissipation 3 W typical Electrical ON State Signal Level 80... 132 Vac Characteristics OFF State Signal Level 0... 35 Vac ON State Input Current 15.5 ma/input @ 115 Vac 6 ma @ 80 V, 20 ma @ 132 V OFF State Input Current 3 ma maximum Response Time ON 10 ms typical OFF 40 ms typical Operating Mode True High Wire Size/ terminal One wire 14 AWG Two wires 20 AWG I/O Map Discrete 1x/0x 16 in/0 out Dimensions W x H x D 40.3 x 145 x 117.5 mm 1.6 x 5.6 x 4.5 in Weight 300 g 0.66 lb Agency VDE 0160; UL 508; and CSA 22.2 No.142 Standards Approvals 448 890 USE 109 00 March 2003

Overview of the DEP 220 Input Module At a Glance Purpose What s in this Chapter? The purpose of this chapter is to describe the DEP 220 input module. This chapter contains the following topics: Topic Page What is the DEP 220 Input Module? 450 DEP 220 Input Module LEDs 451 DEP 220 Input Module Field Wiring 452 DEP 220 Input Module Specifications 454 890 USE 109 00 March 2003 449

DEP 220 Input Module What is the DEP 220 Input Module? Brief Product Description The DEP 220 is a 24 Vdc +25 percent/-15 percent, 16-point discrete input module similar to the DEP 216 module, with a much faster response time (0.5 ms). It senses input signals received from field sensing devices such as pushbuttons, limit and proximity switches, or other 24 Vdc input sources and converts those signals into logic voltage levels that can be used by the PLC. Signals are field wired in two groups, eight signals per group. Inputs are opt-isolated from the system bus. CAUTION Operational Hazard Modicon recommends using two separate power sources with the DEP 220-one for outputs and one for inputs-in order to avoid electrical switching noise. Failure to follow this precaution can result in injury or equipment damage. Note: Inputs do not work if output supply is disconnected. 450 890 USE 109 00 March 2003

DEP 220 Input Module DEP 220 Input Module LEDs LEDs The DEP 220 module has two green LEDs, opposite terminal screws 1 and 12. When one of these LEDs is ON, it indicates that power available to the eight inputs directly below it. The module also has 16 red LEDs, eight opposite terminal screws 3... 10 and eight opposite terminal screws 14... 21; when any one of these LEDs are ON, it indicates voltage present at the corresponding input. 890 USE 109 00 March 2003 451

DEP 220 Input Module DEP 220 Input Module Field Wiring Introduction The DEP 220 is a 24 Vdc +25 percent/-15 percent, 16-point discrete input module similar to the DEP 216 module, with a much faster response time (0.5 ms). It senses input signals received from field sensing devices such as pushbuttons, limit and proximity switches, or other 24 Vdc input sources and converts those signals into logic voltage levels that can be used by the PLC. Signals are field wired in two groups, eight signals per group. Inputs are opto-isolated from the system bus. CAUTION Operational Hazard Modicon recommends using two separate power sources with the DEP 220-one for outputs and one for inputs-in order to avoid electrical switching noise. Failure to follow this precaution can result in injury or equipment damage. Note: Inputs do not work if output supply is disconnected. 452 890 USE 109 00 March 2003

DEP 220 Input Module Wiring Diagram and Simplified Schematic 24 Vdc 24 V Common A sample wiring diagram and simplified schematic for the DEP 220 input module is provided below. 0.16 A 1 2 In1 3 In2 4 In3 5 In4 6 In5 7 In6 8 In7 9 In8 10 11 12 13 In9 14 In10 15 In 11 16 In12 17 In 13 18 In14 19 In15 20 In16 21 22 Green Red First of 16 Input Circuits 5 V Opto Coupler GND I/O Bus Interface 890 USE 109 00 March 2003 453

DEP 220 Input Module DEP 220 Input Module Specifications Table of Specifications The following table contains DEP 220 input module specifications. Module Number of Inputs 16 Topology Number of Groups 2 Points/group 8 Isolation Optocoupler on each input Power Supplies External Source Requirement 20... 30 Vdc for eight inputs Rated Signal Value +24 Vdc Internally Provided Source from the I/O bus 5 V; less than 25 ma Internal Power Dissipation 2 W typical Electrical ON State Signal Level 12... 30 Vdc Characteristics OFF State Signal Level -2... +5 Vdc ON State Input Current 7 ma @ 24 Vdc 8.5 ma @ 30 Vdc Response Time 0.5 ms typical Operating Mode True High Wire Size/terminal One wire 14 AWG Two wires 20 AWG I/O Map Discrete 1x/0x 16 in/0 out Dimensions W x H x D 40.3 x 145 x 117.5 mm 1.6 x 5.6 x 4.5 in Weight 220 g 0.5 lb Agency VDE 0160; UL 508; and CSA 22.2 No.142 Standards Approvals 454 890 USE 109 00 March 2003