CO 2 Unit Coolers for Supermarket Refrigeration Systems

Similar documents
Part A: Fluid properties

Low GWP Replacements for R404A in Commercial Refrigeration Applications

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:

Engineers Newsletter. HVAC Refrigerants: A Balanced Approach. providing insights for today s hvac system designer. volume Refrigerant History

Refrigerant Choices for Commercial Refrigeration. Finding the Right Balance

Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems

Commercial CO2 Refrigeration Systems. Guide for Subcritical and Transcritical CO2 Applications

The phase out of R22. Phase out of HCFCs

RS-44 (R424A) : Q & A

Supermarket Refrigeration Trends in the Asia Pacific Region. Brian Rees Group Technical Manager McAlpine Hussmann Ltd.

Refrigeration and Air Conditioning with Reduced Environmental Impact

Industry insight. Refrigerant gases: an industry in transition.

A car air-conditioning system based on an absorption refrigeration cycle using energy from exhaust gas of an internal combustion engine

Certification in the safe and efficient use of alternative refrigerants

Technical Note: Comparing R407C and R410A as Alternatives for R22. A Technical Note from the Experts in Business-Critical Continuity

News in Data Center Cooling

PG Student (Heat Power Engg.), Mechanical Engineering Department Jabalpur Engineering College, India. Jabalpur Engineering College, India.

RS-52 (R428A) RS-52: PHYSICAL PROPERTIES RS-52 R502 Molecular weight Temperature glide o C Boiling point (1 atm)

Commercial CO 2 Refrigeration Systems

Thermo Scientific Ultra-Low Temperature TSX Series Freezers

Low-GWP Refrigerants for Air Conditioning and Refrigeration Applications. Samuel F Yana Motta

A Performance Comparison of Vapour Compression Refrigeration System Using Eco Friendly Refrigerants of Low Global Warming Potential

How does solar air conditioning work?

Advances in Gas Cooler Design and the New Gas Cooler Product Selector

HFCS, REFRIGERATION AND AIR-CONDITIONING: MINIMISING CLIMATE IMPACT, MAXIMISING SAFETY

Low-GWP Alternatives in Commercial Refrigeration: Propane, CO and 2 HFO Case Studies

RS-24 (R426A): Q & A

R407C GUIDELINES FOR UTILIZATION OF. DATE: August 2009 REFERENCE DOCUMENT NO. RD-0005-E GUIDELINES FOR UTILIZATION OF R407C

ADVANCES IN SUPERMARKET REFRIGERATION SYSTEMS

THE REPLACEMENT OF R-22

Optimization of combined heating and cooling in Supermarkets

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM WITH R404A, R407C AND R410A

Guide to good leak testing

R-32. The next generation refrigerant for air conditioners and heat pumps

SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

The EC Ozone Regulation. Legislative Update and Strategies for HCFC Phase-out

Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems

The Voice of European Air-Conditioning, Refrigeration and Heat Pumps Contractors

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No1, 2010

HIGH-EFFICIENCY CO 2 HEAT PUMP WATER HEATER SYSTEMS FOR RESIDENTIAL AND NON-RESIDENTIAL BUILDINGS

Chapter 3.4: HVAC & Refrigeration System

Environmental perspective in intelligent products and processes

Energy Procedia Energy 00 Procedia (2011) (2012) 56 65

High Pressure Ammonia Systems New Opportunities

The Development of Heat Pump Water Heaters Using CO 2 Refrigerant

R-32. The next generation refrigerant for air conditioners and heat pumps. Superior energy efficiency and low GWP

How To Calculate The Performance Of A Refrigerator And Heat Pump

Air-cooled Chillers with High Speed Centrifugal Compressors

Heating and Cooling Technology and Global Solutions for Food Distribution:

Rittal White Paper 508: Economized Data Center Cooling Defining Methods & Implementation Practices By: Daniel Kennedy

HCFC phase-out has started.

Mohan Chandrasekharan #1

Topics: Refrigerant Proliferation, Global Drivers/Regulation

Guidance for Stationary Refrigeration & Air- Conditioning

Heat Recovery In Retail Refrigeration

Refrigerants for Residential and Commercial Air Conditioning Applications

HFC-free refrigeration technology for the retail business in the Netherlands

Low Global Warming Fluids for Replacement of HFC-245fa and HFC-134a in ORC Applications

Natural Alternatives in the Refrigeration & Air Conditioning Sectors

Replace Your CFC Air Conditioning Chiller

Planning for the ban on R22 in building air conditioning

Why and How we Use Capacity Control

Open Cycle Refrigeration System

THE HUMIDITY/MOISTURE HANDBOOK

Refrigeration and air-conditioning. Alfa Laval s offering at a glance

Vacuum. How It Relates to Refrigeration And Air Conditioning Service

Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.

Refrigerants for residential and commercial air conditioning applications

DRAFT. Appendix C.2 - Air Conditioning Thermodynamics 1

HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

P08 Köldmedier med låg växthuseffekter

Rusty Walker, Corporate Trainer Hill PHOENIX

Refrigerant Levy Panel Working Bank What are the op8ons? Peter Brodribb B. Eng (Mech), MBA

Guidelines of how to instrument, measure and evaluate refrigeration systems in supermarkets PAU GIMÉNEZ GAVARRELL

Automobile Air Conditioning Primer

New EU Legislation on F- Gases

2010 Report of the Refrigeration, Air Conditioning and Heat Pumps Technical Options Committee (RTOC)

An Assessment of Alternative Refrigerants for Automotive Applications based on Environmental Impact

Production of R-134a

THE POSSIBILITY OF USING LIQUIFIED PETROLEUM GAS IN DOMESTIC REFRIGERATION SYSTEMS

Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems

Refrigerant identification and equipment issues in relation to HCFC phase-out. Ole Reinholdt Nielsen

Urban Fare Express Installs First Hillphoenix Advansor Transcritical CO2 Booster System in North America

TECHNICAL ANNEX. Alternatives to HCFCs/HFCs in unitary air conditioning equipment at high ambient temperatures. November 2014

Repair, Retrofit, or Replace Choices for Servicing R-22 Equipment

DuPont Opteon XP10: A new option for more environmentally sustainable commercial refrigeration

Tim Facius Baltimore Aircoil

imagine SOLAR AIR CONDITIONING MADE EASY

UNIT 2 REFRIGERATION CYCLE

Alarm and Detection/Suppression

SIMULATION OF THERMODYNAMIC ANALYSIS OF CASCADE REFRIGERATION SYSTEM WITH ALTERNATIVE REFRIGERANTS

As supermarkets look to lessen

Administrator Lisa P. Jackson Environmental Protection Agency Ariel Rios Building 1200 Pennsylvania Avenue, N.W. Washington, DC

State of the Art Energy Efficient Data Centre Air Conditioning

ADVANCING FLAMMABLE REFRIGERANT ADOPTION IN NORTH AMERICA

A/C System Control Strategies for Major Refrigerant Options

Warm medium, T H T T H T L. s Cold medium, T L

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Transcription:

CO 2 Unit Coolers for Supermarket Refrigeration Systems White Paper September 2009 By: Celena L. Evans Group Manager-Product Management www.thecoldstandard.com

Table of Contents Overview Introduction 3 Historical Refrigerant Usage in North America 4-5 Environmental Focus Global Warming Potential of Refrigeration Systems 6 Carbon Dioxide as a Refrigerant 7 Key Differences of Carbon Dioxide 8 Refrigeration System Types Overview of CO 2 Systems 9 Non-Cascade Systems 10 Cascade Systems 11-12 Carbon Dioxide Refrigeration Systems Benefits 13 Keys to Successful Implementation 13 The Future of Carbon Dioxide Refrigeration Systems 14 References 15 About the Author Celena L. Evans 15 Figures Fig. 1 Historical Use of Refrigerants in North America 4 Fig. 2 ODP and GWP for Various Refrigerants 6 Fig. 3 Carbon Dioxide (CO 2 ) Properties 8 Fig. 4 Compatibility of Refrigeration Systems with CO 2 9 Fig. 5 Direct Expansion Refrigeration Cycle 10 Fig. 6 Subcritical CO 2 Cascade - (DX) 11 Fig. 7 Subcritical Secondary Loop CO 2 System 12

Overview Introduction Supermarket Refrigerant Usage The global supermarket industry is becoming increasingly committed to preserving the environment. One indicator is the existence of corporate sustainability programs. According to the Food Marketing Institute (FMI), over two-thirds of supermarkets have a corporate sustainability program in place or have plans to begin one within two years. As part of these sustainability programs, many supermarkets are taking a closer look at their refrigeration systems in an effort to reduce the overall environmental impact of their stores. Over the last few decades, synthetic refrigerants such as CFCs and HCFCs are being phased out by regulation. Increasing concern and regulatory actions related to the environmental impact of hydro fluorocarbon (HFC) refrigerants has prompted a re-emergence of carbon dioxide (CO 2 ) based refrigeration systems and other low GWP solutions around the world. CO 2 based refrigeration is of interest due to low global warming potential, low price, potential for energy reduction, non-toxicity and a positive safety rating.

Historical Refrigerant Usage In North America The first mechanical refrigeration system using carbon dioxide as a refrigerant was introduced in 1866 by aeronaut, scientist and inventor, T.S.C. Lowe. It was promoted as a safe refrigerant compared to the more noxious alternatives, ammonia and sulfur dioxide, and quickly gained popularity with use peaking in the 1930s (Figure 1). In the late 1930s, CO 2 was replaced in commercial refrigeration by a new refrigerant called freon. Freon was also considered safe, but operated at much lower pressures and required refrigeration components that were less expensive to fabricate. Over the years, a multitude of chlorofluorocarbons (CFCs) and hydro chlorofluorocarbons (HCFC) have been used in commercial refrigeration, as shown in Figure 1. The Montreal Protocol banned CFCs in 1996 and set in place a phase out schedule for HCFCs. This government mandate eliminated use of refrigerants R-12 and R-502. HCFCs, including R-22, are currently being banned by law and in 2010 production will be reduced by 25%. The majority of the U.S. commercial refrigeration industry is moving to HFCs such as R-404, R-507, R-410 and R-134. While HFCs have zero ozone depletion potential (ODP), they have a high global warming potential (GWP). There is also a new, emerging class of refrigerant, Hydrofluoro olefins (HFO), which are low GWP, but are still in the early stages of commercial evaluation. These are still in fact HFCs, but because of the dramatically lower GWP compared to traditional HFCs they have been called HFOs to establish a clear distinction. Figure 1: Historical Use of Refrigerants in North America 90 80 CO 2 R-22 70 60 R-12 % 50 40 30 20 NH 3 10 0 1930 1940 1950 1960 1970 1980 1990 2000 Sinetef 1998 Source: Sintef, 1998

Historical Refrigerant Usage In North America (cont.) There is an emergence of programs building awareness of and the need to reduce refrigerant charge in order to minimize the risks associated with any potential refrigerant leaks. Some regions of the world, such as Europe, have already imposed caps on HFC refrigerants and it is expected that the United States and Canada will soon follow suit. As a result CO 2, which has zero ODP and a GWP of 1, is gaining renewed interest for refrigeration applications.

Environmental Focus Global Warming Potential of Refrigeration Systems As refrigerants with very low ozone depletion potential become more commonplace, the concern has shifted to the global warming potential of refrigerants. Refrigeration systems contribute to global warming directly through refrigerant leaks and indirectly through CO 2 -equivalent emissions resulting from energy needed to operate the system. The vast majority of the global warming is a result of the indirect contribution (power generation), not the direct contribution (leaks). Industry experts have recently agreed to a model that takes into account both the indirect and direct impact of greenhouse gases on global warming. This model, Life-Cycle Climate Performance (LCCP) provides a holistic approach to estimating greenhouse gas emissions during the lifetime of a product. Supermarket refrigeration systems can contain up to 5,000 lbs of refrigerant and the industry average leak rate is 23.5% according to a 2008 statistic from the U.S. Environmental Protection Agency (EPA). The Food Marketing Institute (FMI) reports that refrigeration systems account for nearly half the electricity consumption in a typical supermarket, which is an indirect contributor to global warming. A summary of ODP and GWP of various refrigerants is shown in Figure 2. Figure 2: ODP and GWP for Various Refrigerants REFRIGERANT TYPE ODP GWP (100yr) R-12 CFC 0.820 10,600 R-22 HCFC 0.034 1,700 R-404A HFC 0 3,800 R-410A HFC 0 2,000 R-290 (Propane) Natural 0 ~20 R-717 (Ammonia) Natural 0 <1 R-744 (CO 2 ) Natural 0 1 HFO-1234yf HFO 0 4 Source: Calm & Hourahan, 2001 Currently, the primary driver for using CO 2 refrigeration systems in the United States is to support the overall goals within the supermarket industry toward lower refrigerant charge and lower leak rates. It is anticipated in the near future that carbon footprint will be regulated and reported in financial statements for public companies and carbon credits traded as is, or will soon be the case in other regions of the world, which will further encourage supermarkets to consider CO 2 refrigeration systems.

Carbon Dioxide as a Refrigerant As a result of the movement toward low ozone depletion potential and low global warming potential, alternative and natural refrigerants, including ammonia, hydrocarbons, glycol and carbon dioxide are gaining interest. In addition to its efficiency, carbon dioxide (CO 2 ), also referred to as R-744, is currently viewed as a viable alternative to HFCs for low temperature applications in supermarket refrigeration as it carries a high safety rating because it is non toxic (within a ventilated space) and non flammable. Similar to HFCs, it is also non-ozone depleting. CO 2 has a very low GWP base value of 1 and is a low cost alternative to HFC or hydrocarbons refrigerants. As a result of its physical properties and high volumetric cooling capacity, CO 2 technology naturally lends itself as a viable option for all refrigeration processes.

Key Differences of Carbon Dioxide Carbon dioxide is different from other refrigerants in many ways. Key differences are higher volumetric capacity and high operating pressures. Figure 3 shows at pressures below 75 PSI (5.2 bar) and a temperature of -56.6 F (-49.2 C), CO 2 will turn into a solid. In the subcritical phase, CO 2 is similar to HFC refrigerants except that it has very high pressure. At a room temperature of 77 F (25 C), the pressure of CO 2 is 913 PSI (62 bar). At temperatures above 88 F (31 C), the density of liquid and vapor are identical, and liquid CO 2 cannot be distinguished from vapor. Because vapor CO 2 cannot condense into liquid, in this state the properties of temperature and pressure are no longer related. This is called supercritical. Carbon dioxide in the supercritical phase operates best in a high pressure range (1600-2500 PSI). Transcritical CO 2 systems, which can operate in the supercritical range, are more efficient when operated in the sub-critical range. That is why transcritical CO 2 systems are more widely accepted in regions where ambient temperatures are frequently below 88 F (31 C). Carbon dioxide has a very high volumetric capacity, as much as 5 or 6 times HFCs at medium temperature. This means that the same volume of CO 2 can absorb much more heat than HFCs; therefore, much less CO 2 is required to provide the same cooling effect as HFCs. The pressures at which CO 2 operates are much higher than the working pressure of most common refrigeration components which are designed for pressures of 400 to 650 PSI, which means that special attention must be taken in designing the system and selecting appropriate components. Figure 3: Carbon Dioxide (CO 2 ) Properties T e m 31.1 C 88 F Supercritical p er a t u r e Solid Liquid Vapor Critical Point 5.2 bar 75 PSIA Pressure 72 bar 1058 PSIA

Refrigeration System Types Overview of CO 2 Systems A refrigeration system using carbon dioxide (CO 2 ) as a refrigerant is similar in nature to a refrigeration system using HFC refrigerants. A key difference is that CO 2 operates at higher pressures. In general there are two categories of refrigeration systems non-cascade and cascade. The table below (Figure 4) summarizes suitability of various refrigeration systems for use with CO 2 refrigerant. Figure 4: Compatibility of Refrigeration Systems with CO 2 Non- Cascade Cascade System Type Direct Expansion (DX) Transcritical Subcritical Direct Expansion (DX) Secondary Loop CO 2 Compatible? NO- operating pressures of CO 2 are too high YES- best suited for ambients under 88 F, otherwise inefficient YES YES

Non-Cascade Systems All non-cascade systems contain a single compressor based refrigeration loop and heat is rejected to the ambient. Non-cascade systems can be direct expansion or transcritical. Direct Expansion A direct expansion system is most prevalent in commercial refrigeration as it is simplest in design. The basic components of a DX refrigeration system are a compressor, condenser, flow control (expansion valve) and evaporator as shown in Figure 5. A direct expansion refrigeration cycle is not suitable for application with CO 2 because at room temperature, it is subcritical and high pressure (913 PSI/62 bar). Figure 5: Direct Expansion Refrigeration Cycle Condenser Compressor Flow Control Evaporator Transcritical A transcritical CO 2 system operates in transcritical mode whenever refrigerant is above 88 o F. Transcritical systems operate at higher pressures (maximum 2100 PSI) than HFC systems. The condenser becomes a gas cooler at temperatures above 88 o F and the CO 2 leaving the evaporator is supercritical, a state where vapor cannot condense and one cannot distinguish liquid from vapor. A key benefit of a transcritical system is that it totally eliminates HFCs from the system, thereby eliminating high GWP refrigerants. This reduces the direct component of global warming. A disadvantage of transcritical CO 2 systems is that components capable of being operated safely in such high pressure environments can be more expensive. Another disadvantage is that systems designed for transcritical CO 2 are less efficient when operated in warmer ambients, as is common in most regions of North America. These are the primary reasons why transcritical CO 2 systems are rarely installed in North America. At temperatures below 88 o F, the CO 2 is subcritical and the system is similar to a direct expansion system. A transcritical designed system is also capable of operating as subcritical and is more efficient when doing so. 10

Cascade Systems A cascade CO 2 system is a system made of two refrigeration circuits or loops working together as a single system, but using two different refrigerants. These loops never intermingle. One loop is always a compression loop (i.e. DX) and interfaces with the ambient. Typically a refrigerant, such as R-404A, ammonia or hydrocarbons, is used as the working fluid. The other loop is circuited through the evaporators to cool the load that needs to be refrigerated. This loop uses CO 2 on the low side loop and an HFC on the high side loop to keep the CO 2 in the sub-critical pressure range (maximum 600 PSI). CO 2 in the subcritical range in a cascade system can be direct expansion (DX) or secondary loop. Cascade Subcritical Direct Expansion When the low side loop is direct expansion, the CO 2 is completely evaporated and only vapor exits the evaporator, meaning superheat exists at the exit. A compressor is used to circulate refrigerant. A system diagram is shown in Figure 6. The primary benefit of a subcritical cascade DX CO 2 system is reduced refrigerant charge. Components suitable for these operating pressures are more readily available and therefore more affordable than those needed for a transcritical CO 2 system. In fact, standard components can typically be used. This type of system avoids high pressures associated with a transcritical CO 2 DX system, keeping operating pressures in the range of a traditional HFC system (approximately 450 PSI), which can minimize safety issues. Figure 6: Subcritical CO 2 Cascade - (DX) Cond T C =115 F MT R-404A Compressors Heat Exchanger LT Subcritical CO 2 Compressors MT Case Loads Evap T MT_E =20 F LT Case Loads Evap T LT_E =-25 F 11

Cascade Systems (cont.) Cascade Secondary Loop (Liquid Recirculation) Another approach for subcritical CO 2 is pumped fluid, commonly referred to as secondary loop, shown in Figure 7. The key difference between this and a DX system is a pump is used to circulate the refrigerant instead of a compressor. An excess of refrigerant is provided to the evaporator and only a portion is evaporated, so both liquid and vapor exit the evaporator and there is no superheat. This is also referred to as a flooded coil. Figure 7: Subcritical Secondary Loop CO 2 System Cond T C =115 F MT R-404A Compressors Flooded Coil Heat Exchanger Liquid CO 2 Pumps LT Subcritical CO 2 Compressors MT Case Loads Evap T MT_E =20 F LT Case Loads Evap T LT_E =-25 F 12

Carbon Dioxide Refrigeration Systems Benefits While there are several different approaches, there are numerous benefits of using a CO 2 refrigeration system: High Volumetric capacity reduced compressor and pipe size Low HFC Refrigerant Charge HFCs are eliminated or restricted to a machine room; therefore, line runs are shorter and overall volume is minimized. Lower HFC Refrigerant Costs CO 2 costs are currently 90% less than traditional refrigerants ($1/lb versus $11/lb for R-404A) Reduced Carbon Footprint CO 2 has GWP of 1 vs. HFC GWP of 3300 Reduced Carbon Emissions because refrigerant is confined to a machine room, there are fewer braze joints and a significant reduction in potential for leaks in the system. Additionally, various studies cite benefits of better temperature control due to smaller and warmer pipe temperatures, reduced installation cost and space savings due to smaller line sizes and reduced copper piping, and energy savings potential. Keys to Successful Implementation A coil circuited for carbon dioxide (CO 2 ) fits into essentially the same cabinet as any other unit cooler, but the circuiting is different. An installation should include provisions for additional cooling of the CO 2 to keep CO 2 under 88 o F at all times in the event of a power outage. Additionally, while CO 2 is plentiful, lead times can be long, so customers will need to keep a sufficient charge on site, particularly in remote areas. One of the biggest concerns about CO 2 as a refrigerant is related to safety. With CO 2, a small increase in temperature results in significant increases in pressure. Most building codes require a more complex pressure relief system and a means of pressure relief in any portion of the system that can be isolated. The system should also be designed to vent CO 2 directly to the atmosphere to prevent personal injury in occupied spaces. Systems do require additional controls such as detectors and alarms to ensure safe operation since CO 2 is odorless and colorless. These additional controls may add cost and complexity to the system, compared to a traditional direct expansion system. Successful installation relies heavily on organizations establishing clear design criteria to understand every aspect of the design. Support materials and information such as pressure drop calculators, capacity and circuiting are needed. Finally, installing contractors and staff who will work with the system will require special training. Once more experience is gained with CO 2 systems, it can be expected that up front costs will decrease and in time will fall to levels lower than comparable HFC systems in terms of total cost. 13

The Future of Carbon Dioxide Refrigeration Systems Over a dozen CO 2 based supermarket installations have been completed successfully in the United States, along with many more across the globe. Additionally, future legislation may make it difficult to cost effectively operate a supermarket with high GWP refrigerants. Outside North America, in regions such as Australia, HFCs are coming under increasing scrutiny and are already being subject to more stringent regulation. This will likely further drive the supermarket industry across the globe toward natural refrigerants such as CO 2. 14

References FMI Supermarket Facts: Industry Overview 2007 Calm, J.M. and G. C. Hourahan, Refrigerant Data Summary, Engineered Systems, 18(11):74-88, November 2001 EPA Green-MAC-LCCP (http://www.epa.gov/cppd/mac/compare.htm) Hinde, David, Shitong, Zha, Ph.D, and Lin Lan. Carbon Dioxide in North American Supermarkets, ASHRAE Journal, February 2009 About the Author Celena L. Evans Celena L. Evans is Group Manager Product Management for Heatcraft Refrigeration Products, a subsidiary of Lennox International. At Heatcraft she is responsible for product management, leading product development projects and market research for commercial refrigeration products and market segments. Her professional experience includes engineering, project management and marketing roles spanning several major corporations. Ms. Evans received a Master of Business Administration from The Goizueta Business School at Emory University. She also holds a Bachelor of Science degree in Mechanical Engineering from the University of Rochester, a Master of Science in Mechanical Engineering from Georgia Tech and is a Project Management Professional (PMP). 15

www.heatcraftrpd.com/esolutions For more information on Bohn CO 2 Unit Coolers, contact your sales representative or visit us at www.thecoldstandard.com. A Brand of Heatcraft Refrigeration Products, LLC 2175 West Park Place Blvd. Stone Mountain, GA 30087 (800) 537-7775 www.thecoldstandard.com BN-CUCWP-0909 Version 000