Transient Stability Analysis of Power System With UPFC Using PSAT

Similar documents
COMPARISON OF THE FACTS EQUIPMENT OPERATION IN TRANSMISSION AND DISTRIBUTION SYSTEMS

Topics. HVDC Fundamentals

A COMPARISON ON PERFORMANCE OF TCSC/SSSC FOR A RADIAL SYSTEM

Voltage Stability Improvement using Static Var Compensator in Power Systems

Distributed Flexible AC Transmission System (D FACTS) Jamie Weber ext. 13

Transient analysis of integrated solar/diesel hybrid power system using MATLAB Simulink

The design and performance of Static Var Compensators for particle accelerators

NEURO-FUZZY BASED POWER QUALITY IMPROVEMENTS IN A THREE PHASE FOUR WIRE DISTRIBUTION SYSTEM USING DSTATCOM

How To Improve Power Quality

2012 San Francisco Colloquium

Analysis of the Effect of Tap Changing Transformer on Performance of SVC

Analysis of Space Vector Pulse Width Modulation VSI Induction Motor on various conditions

Advance Electronic Load Controller for Micro Hydro Power Plant

Design and Development of Speed Control of Induction motor drive using Pulse-Width Modulation

Principles of Adjustable Frequency Drives

STATCOM Application at VELCO Essex Substation

DC TRANSMISSION BASED ON VOLTAGE SOURCE CONVERTERS

High-Megawatt Converter Technology Workshop for Coal-Gas Based Fuel Cell Power Plants January 24, 2007 at NIST

HVDC-VSC: transmission technology of the future

Harmonic Reduction and Load Balancing of Three Phase Four Wire DSTATCOM using Three Leg VSC and a Zig Zag Transformer

Simulation and Analysis of PWM Inverter Fed Induction Motor Drive

CO-ORDINATION OF PARALLEL AC-DC SYSTEMS FOR OPTIMUM PERFORMANCE

How To Improve Power Quality

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: [633] [Choudhary, 3(12): December, 2014] ISSN:

Design and Simulation of Soft Switched Converter Fed DC Servo Drive

Performance Analysis of Grid connected Wind Energy Conversion System with a DFIG during Fault Condition

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

Renewable Energy Applications: Photovoltaic and Wind Energy Conversion Systems (WECS)

A MULTILEVEL INVERTER FOR SYNCHRONIZING THE GRID WITH RENEWABLE ENERGY SOURCES BY IMPLEMENTING BATTERY CUM DC-DC CONERTER

Development of Novel Power Electronic Topologies for the Integration of Battery Energy Storage in FACTS Devices

Smart Grid and Renewable Energy Grid Integration. Jian Sun, Professor and Director Department of ECSE & Center for Future Energy Systems

Analysis and Control of Three Phase Multi level Inverters with Sinusoidal PWM Feeding Balanced Loads Using MATLAB

Reactive Power Control of an Alternator with Static Excitation System Connected to a Network

Grid Interconnection of Renewable Energy Sources Using Modified One-Cycle Control Technique

Performance Enhancement of Wound Rotor Induction Motor by VSI with Dynamic Capacitor Controlled Rotor Circuit

A Fuzzy Based Solution for Improving Power Quality in Electric Railway Networks

Alternate Arm Converter Operation of the Modular Multilevel Converter

General Validation Test Program for Wind Power Plants Connected to the Hydro-Québec Transmission System

300 MW Variable Speed Drives for Pump-Storage Plant Application Goldisthal

Parametric variation analysis of CUK converter for constant voltage applications

Control of Distributed Generation Units in Stand-Alone Industrial Networks

AN ULTRA-CHEAP GRID CONNECTED INVERTER FOR SMALL SCALE GRID CONNECTION

Chapter 3 AUTOMATIC VOLTAGE CONTROL

Fundamentals of Power Electronics. Robert W. Erickson University of Colorado, Boulder

2Azerbaijan Shahid Madani University. This paper is extracted from the M.Sc. Thesis

FACTS. Solutions to optimise network performance GRID

New Pulse Width Modulation Technique for Three Phase Induction Motor Drive Umesha K L, Sri Harsha J, Capt. L. Sanjeev Kumar

Renewable Energy Grid Integration

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

POWER TRANSMISSION FROM OFFSHORE WIND FARMS

ABB PSPS Erich Steinmann; Generator control-2013

Mathematical Modeling and Dynamic Simulation of a Class of Drive Systems with Permanent Magnet Synchronous Motors

Guidelines for Large Photovoltaic System Integration

Microcontroller based speed control of three phase induction motor using v/f method

WIND TURBINE TECHNOLOGY

Reactive Power Generation by DFIG Based Wind Farms with AC Grid

Project description. Power Electronics for Reliable and Energy efficient Renewable Energy Systems

Modelling, Simulation and Performance Analysis of A Variable Frequency Drive in Speed Control Of Induction Motor

Comparison of an Efficient Buck Converter Configuration for the DC Power Distribution Of Future Green Data Centers

Reactive Power and Importance to Bulk Power System OAK RIDGE NATIONAL LABORATORY ENGINEERING SCIENCE & TECHNOLOGY DIVISION

Control Strategy for Three Phase Shunt Active Power Filter with Minimum Current Measurements

Closed Loop PWM Control for Induction Motor Drive Using Dual Output Three Phase Inverter

Droop Control Forhybrid Micro grids With Wind Energy Source

A student friendly toolbox for power system analysis using MATLAB

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

Simulation and Analysis of Parameter Identification Techniques for Induction Motor Drive

Solar Power Plant Design and Interconnection

MODELLING AND SIMULATION OF SVPWM INVERTER FED PERMANENT MAGNET BRUSHLESS DC MOTOR DRIVE

HVDC Light, a tool for electric power transmission to distant loads

Control of a Three Phase Induction Motor using Single Phase Supply

Recent Siemens HVDC Activities Yuriy Kazachkov Siemens PTI

Keywords: Self-Excited Induction Generator (SEIG), Single Phase Synchronous D-Q Frame Theory, Static Synchronous Compensator (STATCOM).

Application of GA for Optimal Location of FACTS Devices for Steady State Voltage Stability Enhancement of Power System

Low Frequency AC Transmission System

System Protection Schemes in Eastern Denmark

Limitation of Minimal Excitation Current by Load Angle Regulation

Verification of Short Circuit Test Results of Salient Poles Synchronous Generator

Power Quality & Custom Power

Simulation of VSI-Fed Variable Speed Drive Using PI-Fuzzy based SVM-DTC Technique

Holly STATCOM FACTS to replace critical generation, operational experience

Simulation on Micro Wind Power Generator with Battery Energy Storage for Critical Load

The Grid Interconnection of Renewable Energy at Distribution Level with the Features of High Power-Quality Improvement

Requirements for Offshore Grid Connections. in the. Grid of TenneT TSO GmbH

SAMPLE OF THE STUDY MATERIAL PART OF CHAPTER 3. Symmetrical Components & Faults Calculations

Scholars Research Library

Modeling and Analysis of DC Link Bus Capacitor and Inductor Heating Effect on AC Drives (Part I)

Submarine Cable Power Transmission using DC High-Voltage Three-Level Converters

Knowing the FACTS. FACTS that enhance power quality in rail feeder systems

Mechanical and electrical rebuilding of a turbine generator for phase-shift operation

System configuration of v-f control with solar PV generator operating at MPPT with a battery storage System

Wide Area Monitoring Current Continental Europe TSOs Applications Overview

Control Development and Modeling for Flexible DC Grids in Modelica

TRANSIENT STABILITY ANALYSIS AND ENHANCEMENT OF IEEE- 9 BUS SYSTEM

Modeling and Control for Smart Grid Integration with MPPT of Solar/Wind Energy Conversion System S. Sathish Kumar 1, B.Swapna 2, Dr.C.

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

6545(Print), ISSN (Online) Volume 4, Issue 2, March April (2013), IAEME & TECHNOLOGY (IJEET)

Transcription:

Transient Stability Analysis of Power System With UPFC Using PSAT Rajesh Kr Ahuja, Mukul Chankaya Dept. of Electrical Engineering, YMCA University of Science &Technology, Faridabad (Haryana), India Abstract UPFC is a versatile FACTS controller that can regulate the Power Flow through the Line by controlling its Series and shunt parameters. In shunt it is having STATCOM and in series SSSC are employed can independently control the Line Power Flow. Two Converters improves the flexibility and provide additional degree of freedom in Power System. With the application of UPFC, Transient stability of the system can be Improved. This Paper shows that how Transient Stability of the Inter Area system is Improved. The Mathematical Model of Transient Stability is also given in this Paper. Keywords Power system, FACTS, Transient stability, Inter area power system. I. INTRODUCTION In recent years, energy, environment, deregulation of power utilities have delayed the construction of both generation facilities and new transmission lines. FACTS devices are available, which can help Power Engineers to deal with problems like Large Signal Stability and economic Factors that gives strong incentives to raise the Stability limit of the System, depending upon the diverse conditions. Facts devices can provide fast control of Active and Reactive power through Power system. Among the converter based FACTS devices Static Synchronous Compensator (STATCOM) and Unified Power Flow Controller (UPFC) are the popular FACTS devices. They play an important role, not only in increasing the amount of energy transported over the lines, but also in oscillatory and transient-stability enhancement, system reliability, and controllability over the power flow. Considering the practical application of the UPFC in power systems, it is of importance and interest to investigate the benefits as well as model of these devices for power system Transient Analysis. Unified Power Flow Controller (UPFC) is a power electronic based device that has capability of controlling the power flow through the line by controlling appropriate its series and shunt parameter. It has been reported that UPFC can improve transient stability of a system. II. PRINCIPLE OF UPFC One FACTS controller in particular, the Unified Power Flow Controller (UPFC), is capable of concurrently or selectively controlling transmission line power flows, voltage magnitudes and phase angles in a power system. Here in fig.1 given below UPFC is shown with both PWM and Phase Control strategy. The Unified Power Flow Controller (UPFC) concept was proposed by Gyugi in 1991. UPFC is an electrical device for providing fast-acting reactive power compensation on high-voltage electricity transmission networks. The UPFC is a combination of a Static Synchronous Compensator (STATCOM) and a Static Synchronous Series Compensator (SSSC) coupled via a common DC voltage link. The UPFC is made out of two voltage-source converters (VSC) with semiconductor devices having turn-off capability, sharing a common dc capacitor and connected to a power system through coupling transformers. The basic UPFC structure is depicted in Figure shown above. This figure represents control strategies (pulse-width modulation (PWM) and phase control). The reactive power is generated/absorbed independently by each converter and does not flow through the dc link. There are two basic control strategies that can be utilized to control the switching of the semiconductor switches in the converters, i.e., PWM and phase controls. GTO switches operate adequately at the low switching frequencies required in phase control, but present high losses at the high switching frequencies needed for PWM control. 708

Transmission Line V pq V+ V pq Supply Transformer Series Transformer ac Converter 1 + _ V dc Converter 2 ac Figure 2 11 Bus test System Without FACTS devices Measured Variable Parameter Settings control Figure 1.UPFC is shown with both PWM and Phase Control strategy. However, recent advances in high voltage IGBT technology have led to the development of the Integrated Gate Commutated Thyristor (IGCT), which is basically an optimum combination of thyristor and GTO technology at low cost, low complexity, and high efficiency. It can handle higher switching frequencies with relatively low losses, allowing for the practical implementation of PWM control methodologies. III. PSAT SIMULATION MODEL SYSTEM ( I )UNDER STUDY In this Model there are 11 Buses, Bus No. 3 is kept as Slack bus which maintain its voltage at 1 p.u. and Bus 1,2 & 4 are Generator (PV) Buses. Fault is simulated at Bus 8 at 1sec. and Fault clearing time at 1.05 sec. V ref Z ref Q ref Q* ref The all four Generators has been modeled with Power Rating of 900MVA and 20KV at 60HZ frequency. All buses connected to each other by π- Section of transmission line. The automatic voltage regulator used is type 3 in PSAT tool of MATLAB with the range of +100KV to -100KV and having the gain of 200p.u. for maintaining the voltage level as near to 1p.u. Turbine Governor is used of type 2 and having the ref. speed of 1 p.u. and the droop is kept 0.02p.u. with max. torque and min. torque limit at1.2 and 0.3p.u. Generators are connected to the system via transformers maintaining the system voltage at 230KV and 100MVA. Load is also connected to the Bus7 and Bus8. In this Model, Voltage profile at all 11 buses and Rotor angle are studied without any FACTS devices. SYSTEM ( II )UNDER STUDY The all the parameters of Generators, Slack bus, Transformers and Load are kept same as were in above given Model. UPFC is employed in between Bus8 where fault is simulated and Bus9 POD controller for maintaining the voltage at faulty bus. The Voltage profile of all the buses and Rotor angle are studied at different Fault clearing time with UPFC and there results are compared with the results of 11Bus test system without any FACTS device. 709

. Figure 6 Rotor angle 1,2,3& 4 with UPFC at fault clearing time at 1.2sec. Figure3 11Bus test System With United Power Flow Controller IV. SIMULATION RESULTS Fig 4 14 show the simulation results of rotor angle, voltage at different buses and angular frequencies in PSAT ROTOR ANGLE The graphs shows the Generator rotor angles w.r.t. time in case with and without UPFC. Without using the UPFC the Rotor Angle are increasing and go out of synchronism but with the UPFC they remain in synchronism at time 1.05sec. and 1.2 sec. both. VOLTAGE PROFILE The graph shows the voltages at various buses with and without UPFC at different fault clearing time. Voltage at Bus1 Figure 4 Rotor angle 1,2,3& 4 without UPFC. Figure 5 Rotor angle 1,2,3& 4 with UPFC at fault clearing time a 1.05sec.. Figure 7 Voltage at Bus 1 710

As shown in the fig.7 voltage profile of Bus1 at different fault clearing time with and without UPFC. With FACTS Device (UPFC) the voltage is settling down at 1.2 sec without any oscillatory behavior, whereas without UPFC it takes more then 2 sec due to the oscillations after the major disturbance settles at 1.2 sec. Bus 1 is a PV bus. Voltage at Bus3 Voltage at Bus 2 Voltage at Bus4 Figure 9. Voltage profile at Bus 3 Figure 8 Voltage profile at bus 2 Voltage profile of Bus2 is again a PV bus and showing voltage rise after fault clearance time without UPFC and take more time to settle down but with UPFC it follows the normal profile and settles down quickly. Bus 3 is a Slack bus so Voltage profile will be same with and without FACTS device. Bus 4 is a PV Bus and the settling time is reduced with UPFC Figure 10 Voltage profile at bus 4 711

Voltage at Bus 11 Fig. 12 shows Angular freq at all generator Buses without UPFC. The peak value of remain at 1.0012 The fault is simulated at 1sec and cleared at 1.05sec. Figure 13 Angular freq with UPFC Figure 11 Voltage profile at bus 11 Fig.13 shows Angular freq with UPFC at fault clearing time 1.05sec. At Bus11 settling time is reduced and Voltage reaches to its pre fault value quickly without oscillations. ANGULAR FREQUENCY Figure 14 Angular freq with UPFC Fig.14 shows Angular freq with UPFC at Fault clearing time 1.2sec. Figure 12 Angular freq at all generator Buses With the increase in the fault clearing time the peak value of increases to 1.005. 712

V. CONCLUSION This paper investigates the capability of UPFC on transient stability of a Two-area power system. The analysis of Generator Rotor angle, Voltage Profile and Angular Freq is done with and without UPFC at different fault clearing time. Without UPFC the Rotor angle of all the buses increases and will lead the system out of synchronism whereas without UPFC they are decreasing and settling down. System will remain in synchronism. The Buses of Area 1 i.e. Bus 1,2,5,6 and 7 and The Buses of area 2 Bus 3,4,9,10 and 11 their settling time is more then 2sec without UPFC.With the application of UPFC the settling time is reduced to 1.18 sec. for all buses. The Angular Freq without UPFC settles to 1 p.u. value after 20sec. with UPFC Angular freq starts settling down after 15sec. at fault clearing time 1.05 sec. and 1.2 sec. REFERENCES [1] N.G. Hingorani and L. Gyugyi, Understanding FACTS: concepts and technology of flexible ac transmission systems, IEEE Press, NY, 1999. [2] Y.H. Song and A.T. Johns, Flexible ac transmission systems (FACTS), The Institute of Electrical Engineers, London, 1999. [3] Claudio Cañizares, Edvina Uzunovic, and John Reeve, Transient Stability and Power Flow Models of the Unified Power Flow Controller for Various Control Strategies [4] K. R. Padiyar and A. M. Kulkarni, Control Design and Simulation of Unified Power Flow Controller, IEEE Trans. Power Delivery, vol. 13, no. 4, pp. 1348 1354, Oct. 1998. [5] L. Gyugyi, Dynamic compensation of ac transmission line by solid-state synchronous voltage sources, IEEE Trans. Power Delivery, Vol. 9, pp. 904-911, Apr. 1994. [6] V.Vital, N. Bhatia and A.A. Fouad, Analysis of the Inter-area Mode Phenomenon in Power Systems Following Large Disturbances, IEEE Transactions on Power System, Vol. 6, No. 4, 1991. [7] P. Kundur, Power System Stability and Control, Mc Graw-Hill, Singapore. [8] K.R.Padiyar and A.M.Kulkarni. Control Design and Simulation of Unified Power Flow Controller IEEE Transaction on Power delivery, Vol.13 No 4, October (1998). [9] O.P.Dwivedi, J.G.Singh and S.N.Singh Simulation and Analysis of Unified Power Flow Controller Using SIMULINK National Power System Conference, NPSC( 2004). 713