1 Limitation of Minimal Excitation Current by Load Angle Regulation Tomislav Idzotic 1), Gorislav Erceg 2), Damir Sumina 3) Faculty of Electrical Engineering and Computing Unska 3, Zagreb, Croatia Tel. / Fax: + (385 1) / ) [email protected], 2) [email protected], 3) [email protected] Abstract - A synchronous generator connected to an AC system in capacitive operating mode is near its stability limit. In such conditions, if some disturbances in the system appear, a synchronous generator could lose the synchronism. The classical solution of this problem is to keep a generator in stabile operating range of P-Q diagram by limiting the minimal excitation current. This article analysis impact of additional control algorithms which are included in classical excitation regulation system with the purposes of keeping a generator in synchronism when some disturbances appear and generator is near its stability limit. These control algorithms include load angle estimation by corresponding P-Q diagram and load angle regulator which task is to keep the load angle of a synchronous generator operating in capacitive mode on the reference value so that generator remains in synchronism. I. INTRODUCTION. A synchronous generator which is connected to an AC system has to remain in synchronism even in some extreme situations that can appear in the operating conditions keeping a generator in the range of permissible loading. In the real system, the exceeding of allowed loading would cause the activation of generator protection and disconnection of a synchronous generator from an AC system. The voltage regulators of synchronous generators have the excitation current limitations as it is dictated by P- Q diagram (fig. 1.). This enables optimal utilization of the permissible loading and safer work of a generator that is operating in parallel with a distribution network. of the excitation current, limit the load angle and a generator will not lose synchronism. These minimal limitations in excitation current can be done based on P-Q diagram of a synchronous generator or by load angle regulation in under-excitation operating mode. These papers present minimal limitation of the excitation current based on the load angle regulation. Presented solution in classical regulation structure, in which the voltage regulator is superior to excitation current regulator, includes the load angle regulator. When load angle is near its unstable value, the voltage regulator is turned off and the load angle regulator is turned on until load angle is decreased. In this situation load angle regulator sets the excitation current reference to its maximal value and on that way decreases the load angle so that generator remains in synchronism. So this regulation method enables stabile work of generator near the stability limits and expands the operating range of generator. The load angle estimation is based on voltage and current measurement of a synchronous generator. By load angle estimation is avoided additional sensor. II. THE EXCITATION REGULATION STRUCTURE OF A SYNCHRONOUS GENERATOR The excitation regulation structure with load angle estimation and additional load angle regulator is presented on the fig. 2. uref Ugen controller ifref If controller pwm if ϑ ref ϑ controller ϑkrit ugen ϑestimated Q if iw uuv uwv Fig. 1. P-Q diagram of a synchronous generator including all limitations Under-excitation (capacitive) operating mode of a synchronous generator is appeared in systems with underloaded long power transmission lines, by connecting long power transmission lines to voltage and by asynchronous work of regulating transformer regulators. Minimal limits DIGITAL CONTROL SYSTEM Fig. 2. The excitation regulation structure of a synchronous generator with load angle estimation and additional load angle regulator According to the simulation results it is chosen PID regulator. Proportional and derivative part of the PID regulator determine the system response during start up and
2 integral part assures that the load angle is equal to its wanted reference value in static operating conditions. In the moment of turning off the voltage regulator and turning on the load angle regulator the state of the integrator of the voltage regulator is written into the integrator of the load angle regulator. So this transition between two regulators is smooth and there is no unwanted step in excitation current reference. III. MEASUREMENT AND ESTIMATION OF THE LOAD ANGLE OF A SYNCHRONOUS GENERATOR For load angle estimation is used voltage-current vector diagram (fig. 3.). I ( X q E X d ) I X q ϑ I ϕ U I X q cos ϕ I R sin ϕ tg ϑ = (1) U + I X q sin ϕ + I R cos ϕ respectively I X q P I R Q ϑ = arctg. (2) U S + I X q Q + I R P Quadrature-axis synchronous reactance X q is needed for this estimation method. Its value is well known from the producers and is not very dependent on saturation. In situations when short circuit appears, generator voltage suddenly falls and generator current rises. In such situations, measuring equipment goes to saturation, and the measured results of active and reactive power are not reliable. The estimated value for load angle is not correct too. In such cases, the system forces the excitation current. The excitation current rises to its maximal value that is determined by its maximal limit. When short circuit appears, the load angle estimator sets the load angle to its maximal value and force the excitation current to its maximum limit. The load angle estimation algorithm is implemented in the developed digital system DIRES 21 [2] (fig. 4.). IV. EXPERIMENT Fig. 3. Vector diagram From diagram on the fig. 3. is obtained: Experimental verification of the excitation regulation system of a synchronous generator is made on the laboratory model of the aggregate (fig. 5.). Digital excitation regulation system includes four DSPs ADMC3 [2]. The excitation winding of a synchronous generator is fed by IGBT converter. Fig. 4. Load angle estimation algorithm
3 cos ϕ =.8 3 x 38V 3 x 38V Fig. 5. Digital regulation system and laboratory model of the aggregate The analysis is made with and without load angle regulator on the step change of the prime mover moment of the aggregate. Experimental responses of the excitation system of the synchronous generator operating in capacitive mode (capacitive loading Q=.8 pu of the nominal power) on the step change of active power P=1. pu without load angle regulator are shown on the fig. 6. In this case the generator loses the synchronism. When load angle regulator is included in excitation system the generator remains in synchronism (fig. 7.) Voltage ( % ) Current ( % ) Active power ( % ) Reactive power ( % ) -5-25
4 Excitation current ( % ) Estimated load angle (degrees ) Fig. 6. Experimental responses on the step change of moment without load angle regulator and Q=.8 pu Voltage ( % ) 98, , , , Current ( % ) 15 Active power ( % ) Reactive power ( % ) Excitation current ( % ) Estimated load angle (degrees ) Fig. 7. Experimental responses on the step change of moment with load angle regulator and Q=.8 pu (cap) Maximal load angle value is 7 º el. Even when the voltage regulator reference is set to zero, the generator remains in synchronism during step change of active power P=1. (fig. 8.).
5 Voltage ( % ) Current ( % ) 15 Active power ( % ) Reactive power ( % ) Excitation current ( % ) Estimated load angle (degrees) Fig. 8. Experimental responses on the step change of moment with voltage regulator reference equal to zero V. CONCLUSIONS Presented experimental results show positive performance of the load angle regulator, which is added in classical excitation regulation system, on the stability of a synchronous generator in static as well as in dynamic operating conditions. In static operating conditions with increased active power, load angle regulator keeps the load angle on its reference value so that generator remains in stabile operating range. In dynamic operating conditions load angle regulator quickly increases the excitation current of a synchronous generator and on that way improve the stability of a synchronous generator which is connected to an AC system. Load angle regulator added in classical excitation system improves the stability of a synchronous generator in capacitive operating mode. SYMBOLS ϑ - load angle of a synchronous generator X d, X q reactances of a synchronous generator R armature resistance of a synchronous generator P active power of a synchronous generator Q reactive power of a synchronous generator S apparent power of a synchronous generator U, I voltage and current of a synchronous generator ϕ - phase angle REFERENCES [1] Analog Devices, ADSP-21 Family User s Manual, Analog Devices Inc, Third Edition, 1995 [2] Erceg G., Idzotic T., Tonkovic N., "Digital Control System of a Synchronous Generator", EPE-PEMC, 22. [3] Erceg G., Idzotic T., Tonkovic N., "Hydro generating unit digital control system, Hydro, 23.
6 [4] Girgis G.K., Vu H.D., Verification of limiter performance in modern excitation control systems, IEEE Trans. on Energy Conversion, Vol. 1, No. 3, [5] Eberly T.W., Schaefer R.C., Minimum/maximum excitation limiter performance goals for small generation, IEEE Trans. on Energy Conversion, Vol. 1, No. 4, [6] Ramos A.J.P., Lins L.R., Fittipaldi E.H.D., Monteath L., Performance of under excitation limiter of synchronous machines for system critical disturbances, IEEE Trans. on Power Systems, Vol. 12, No. 4, [7] Working group of the excitation systems subcommittee, Underexcitation limiter models for power system stability studies, IEEE Trans. on Energy Conversion, Vol. 1, No. 3, 1995.
Determination of Load Angle for Salient-pole Synchronous Machine
.478/v48--8- MEASUREMENT SCIENCE REVIEW, Volume, No. 3, Determination of Load Angle for Salient-pole Synchronous Machine D. Sumina, A. Šala, R. Malarić 3 Faculty of electrical engineering and computing,
SYNCHRONOUS MACHINES
SYNCHRONOUS MACHINES The geometry of a synchronous machine is quite similar to that of the induction machine. The stator core and windings of a three-phase synchronous machine are practically identical
Circuits with inductors and alternating currents. Chapter 20 #45, 46, 47, 49
Circuits with inductors and alternating currents Chapter 20 #45, 46, 47, 49 RL circuits Ch. 20 (last section) Symbol for inductor looks like a spring. An inductor is a circuit element that has a large
Advance Electronic Load Controller for Micro Hydro Power Plant
Journal of Energy and Power Engineering 8 (2014) 1802-1810 D DAVID PUBLISHING Advance Electronic Load Controller for Micro Hydro Power Plant Dipesh Shrestha, Ankit Babu Rajbanshi, Kushal Shrestha and Indraman
Equipment: Power Supply, DAI, Transformer (8341), Variable resistance (8311), Variable inductance (8321), Variable capacitance (8331)
Lab 5: Single-phase transformer operations. Objective: to examine the design of single-phase transformers; to study the voltage and current ratios of transformers; to study the voltage regulation of the
MICRO HYDRO POWER PLANT WITH INDUCTION GENERATOR SUPPLYING SINGLE PHASE LOADS
MICRO HYDRO POWER PLANT WITH INDUCTION GENERATOR SUPPLYING SINGLE PHASE LOADS C.P. ION 1 C. MARINESCU 1 Abstract: This paper presents a new method to supply single-phase loads using a three-phase induction
Application for Small Generator Facility Interconnection Tier 2, Tier 3 or Tier 4 Interconnection
Application for Small Generator Facility Interconnection Tier 2, Tier 3 or Tier 4 Interconnection (See ARSD chapter 20:10:36 for the requirements for a Tier 2, Tier 3, or Tier 4 Interconnection.) Applicant/Interconnection
Transient analysis of integrated solar/diesel hybrid power system using MATLAB Simulink
Transient analysis of integrated solar/diesel hybrid power system using ATLAB Simulink Takyin Taky Chan School of Electrical Engineering Victoria University PO Box 14428 C, elbourne 81, Australia. [email protected]
Understanding Delta Conversion Online "Power Regulation" - Part 2
Application Note #40 Understanding Delta Conversion Online "Power Regulation" - Part 2 Introduction This application note is the second in a series on delta conversion theory of operation. For complete
Chapter 3 AUTOMATIC VOLTAGE CONTROL
Chapter 3 AUTOMATIC VOLTAGE CONTROL . INTRODUCTION TO EXCITATION SYSTEM The basic function of an excitation system is to provide necessary direct current to the field winding of the synchronous generator.
Lab 8: DC generators: shunt, series, and compounded.
Lab 8: DC generators: shunt, series, and compounded. Objective: to study the properties of DC generators under no-load and full-load conditions; to learn how to connect these generators; to obtain their
TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES
SED-635 Digital Excitation System SED-635 is a complete excitation system capable of adapting to control synchronous generators of any size. The integration of the TOUCH SCREEN operator interface and a
2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?
Extra Questions - 2 1. A straight length of wire moves through a uniform magnetic field. The e.m.f. produced across the ends of the wire will be maximum if it moves: a) along the lines of magnetic flux
Physical Address: City: State: Zip Code:
Application for Small Generator Facility Interconnection Tier 2, Tier 3 or Tier 4 Interconnection (For Small Generator Facilities with Electric Nameplate Capacities of 10 MW and less) Applicant Contact
VOLTAGE REGULATOR AND PARALLEL OPERATION
VOLTAGE REGULATOR AND PARALLEL OPERATION Generator sets are operated in parallel to improve fuel economy and reliability of the power supply. Economy is improved with multiple paralleled generators by
Topics. HVDC Fundamentals
Topics HVDC Fundamentals Conventional Converters Capacitor Commutated Converters Voltage Source Converters Reactive Power Requirements System Configurations Tapping Control basics High Power Transmission
POWER QUALITY ISSUES IN A STAND-ALONE MICROGRID BASED ON RENEWABLE ENERGY
POWER QUALITY ISSUES IN A STAND-ALONE MICROGRID BASED ON RENEWABLE ENERGY IOAN ŞERBAN, CORNELIU MARINESCU Key words: Microgrid (MG), Power quality, Dump load, Frequency control. The paper presents several
Keywords: synchronous generator, synchronous motor, automatic voltage regulator, V- curves, synchronizing power, hunting, excitation system
SYNCHRONOUS MACHINES Tze-Fun Chan Hong Kong Polytechnic University, Hong Kong, China Keywords: synchronous generator, synchronous motor, automatic voltage regulator, V- curves, synchronizing power, hunting,
Available online at www.sciencedirect.com Available online at www.sciencedirect.com
Available online at www.sciencedirect.com Available online at www.sciencedirect.com Procedia Procedia Engineering Engineering () 9 () 6 Procedia Engineering www.elsevier.com/locate/procedia International
Simulation and Analysis of Parameter Identification Techniques for Induction Motor Drive
International Journal of Electronic and Electrical Engineering. ISSN 0974-2174 Volume 7, Number 10 (2014), pp. 1027-1035 International Research Publication House http://www.irphouse.com Simulation and
Control Strategies of the Doubly Fed Induction Machine for Wind Energy Generation Applications
Control Strategies of the Doubly Fed Induction Machine for Wind Energy Generation Applications AUTHORS Dr. Gonzalo Abad, The University of Mondragon, SPAIN. Dr. Miguel Ángel Rodríguez, Ingeteam Transmission
Modeling and Simulation of a Novel Switched Reluctance Motor Drive System with Power Factor Improvement
American Journal of Applied Sciences 3 (1): 1649-1654, 2006 ISSN 1546-9239 2006 Science Publications Modeling and Simulation of a Novel Switched Reluctance Motor Drive System with Power Factor Improvement
Renewable Energy Laboratory for Engineering Students
dspace User Conference 2010 India Sept 24 th 10 Renewable Energy Laboratory for Engineering Students H.T Jadhav, S. D. Joshi Rajarambapu Institute Of Technology ABSTRACT Renewal Energy is now included
8 Speed control of Induction Machines
8 Speed control of Induction Machines We have seen the speed torque characteristic of the machine. In the stable region of operation in the motoring mode, the curve is rather steep and goes from zero torque
Effective: September 10, 2006 Vermont Attachment 1 to Rule 5.500 Public Service Board Page 1 of 6
Public Service Board Page 1 of 6 STANDARD APPLICATION FOR INTERCONNECTION OF GENERATION RESOURCES IN PARALLEL TO THE ELECTRIC SYSTEM OF: (Interconnecting Utility) Preamble and Instructions: An owner of
Requirements for Offshore Grid Connections. in the. Grid of TenneT TSO GmbH
Requirements for Offshore Grid Connections in the Grid of TenneT TSO GmbH Bernecker Straße 70, 95448 Bayreuth Updated: 21 December 2012 1/10 Requirements for Offshore Grid Connections in the Grid of TenneT
Lab 14: 3-phase alternator.
Lab 14: 3-phase alternator. Objective: to obtain the no-load saturation curve of the alternator; to determine the voltage regulation characteristic of the alternator with resistive, capacitive, and inductive
AN ULTRA-CHEAP GRID CONNECTED INVERTER FOR SMALL SCALE GRID CONNECTION
AN ULTRA-CHEAP GRID CONNECTED INVERTER FOR SMALL SCALE GRID CONNECTION Pramod Ghimire 1, Dr. Alan R. Wood 2 1 ME Candidate Email: [email protected] 2 Senior Lecturer: Canterbury University
Reactive Power Control of an Alternator with Static Excitation System Connected to a Network
Reactive Power Control of an Alternator with Static Excitation System Connected to a Network Dr. Dhiya Ali Al-Nimma Assist. Prof. Mosul Unoversity Dr. Majid Salim Matti lecturer Mosul University Abstract
7. Reactive energy compensation
593 7. Reactive energy compensation 594 7. REACTIVE ENERGY COMPENSATION Reactive energy compensation is an important element for reducing the electricity bill and improving the quality of the electrical
Appendix N: GENERATOR DATA SHEET FOR SYNCHRONOUS GENERATORS CONNECTED TO PG&E ELECTRIC SYSTEM
Appendix N: GENERATOR DATA SHEET FOR SYNCHRONOUS GENERATORS CONNECTED TO PG&E ELECTRIC SYSTEM TECHNICAL DATA SHEET FOR SYNCHRONOUS MACHINES IN THE PG&E SYSTEM FOR POWER FLOW, TRANSIENT STABILITY, AND FAULT
COMPARISON OF THE FACTS EQUIPMENT OPERATION IN TRANSMISSION AND DISTRIBUTION SYSTEMS
COMPARISON OF THE FACTS EQUIPMENT OPERATION IN TRANSMISSION AND DISTRIBUTION SYSTEMS Afshin LASHKAR ARA Azad University of Dezfoul - Iran [email protected] Seyed Ali NABAVI NIAKI University of Mazandaran
Equipment: Power Supply, DAI, Variable resistance (8311), Variable inductance (8321)
Lab 4: 3-phase circuits. Objective: to study voltage-current relationships in 3-phase circuits; to learn to make delta and Y connections; to calculate and measure real, apparent, and reactive powers. Equipment:
A COMPARISON ON PERFORMANCE OF TCSC/SSSC FOR A RADIAL SYSTEM
IMPACT: International Journal of Research in Engineering & Technology (IMPACT: IJRET) ISSN(E): 31-8843; ISSN(P): 347-4599 Vol. 3, Issue 9, Sep 015, 7-18 Impact Journals A COMPARISON ON PERFORMANCE OF TCSC/SSSC
Basics of Electricity
Basics of Electricity Generator Theory PJM State & Member Training Dept. PJM 2014 8/6/2013 Objectives The student will be able to: Describe the process of electromagnetic induction Identify the major components
Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.
Lab 9: Synchronous motor. Objective: to examine the design of a 3-phase synchronous motor; to learn how to connect it; to obtain its starting characteristic; to determine the full-load characteristic of
Variable Frequency Drives - a Comparison of VSI versus LCI Systems
Variable Frequency Drives - a Comparison of VSI versus LCI Systems Introduction TMEIC is a leader in the innovative design and manufacture of large ac variable f requency drive systems. TMEIC has been
Large Generators and High Power Drives
Large Generator and High Power Drive Content of lecture 1. Manufacturing of Large Electrical Machine 2. Heating and cooling of electrical machine 3. Eddy current loe in winding ytem 4. Excitation of ynchronou
THIS paper reports some results of a research, which aims to investigate the
FACTA UNIVERSITATIS (NIŠ) SER.: ELEC. ENERG. vol. 22, no. 2, August 2009, 227-234 Determination of Rotor Slot Number of an Induction Motor Using an External Search Coil Ozan Keysan and H. Bülent Ertan
ε: Voltage output of Signal Generator (also called the Source voltage or Applied
Experiment #10: LR & RC Circuits Frequency Response EQUIPMENT NEEDED Science Workshop Interface Power Amplifier (2) Voltage Sensor graph paper (optional) (3) Patch Cords Decade resistor, capacitor, and
Mathematical Modeling and Dynamic Simulation of a Class of Drive Systems with Permanent Magnet Synchronous Motors
Applied and Computational Mechanics 3 (2009) 331 338 Mathematical Modeling and Dynamic Simulation of a Class of Drive Systems with Permanent Magnet Synchronous Motors M. Mikhov a, a Faculty of Automatics,
ATTACHMENT F. Electric Utility Contact Information Utility Name. For Office Use Only
ATTACHMENT F CATEGORY 2 GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 20 KW BUT LESS THAN OR EQUAL TO 150 KW Also Serves as Application for Category
INTRODUCTION TO SYNCHRONIZING AUTOMATIC SYNCHRONIZING CONSIDERATIONS AND APPLICATIONS
INTRODUCTION TO SYNCHRONIZING AUTOMATIC SYNCHRONIZING CONSIDERATIONS AND APPLICATIONS INTRODUCTION It is the intention of this presentation to provide an explanation of the automatic synchronizing process,
System Protection Schemes in Eastern Denmark
System Protection Schemes in Eastern Denmark Joana Rasmussen COWI A/S, Energy Department System Protection Schemes in Eastern Denmark 1.Advanced system protection schemes are investigated and perspectives
ABB PSPS Erich Steinmann; Generator control-2013
ABB PSPS Erich Steinmann; Generator control-2013 GENERATOR CONTROL THE MODULAR SOLUTION FOR GENERATORS To make sure that power is efficiently converted into electric energy, it is necessary to supervise
Verification of Short Circuit Test Results of Salient Poles Synchronous Generator
Verification of Short Circuit Test Results of Salient Poles Synchronous Generator Abdul Jabbar Khan 1, Amjadullah Khattak 2 1 PG Student, University of Engineering and Technology, Peshawar, Department
Full representation of the real transformer
TRASFORMERS EQVALET CRCT OF TWO-WDG TRASFORMER TR- Dots show the points of higher potential. There are applied following conventions of arrow directions: -for primary circuit -the passive sign convention
Mathematical Modelling of PMSM Vector Control System Based on SVPWM with PI Controller Using MATLAB
Mathematical Modelling of PMSM Vector Control System Based on SVPWM with PI Controller Using MATLAB Kiran Boby 1, Prof.Acy M Kottalil 2, N.P.Ananthamoorthy 3 Assistant professor, Dept of EEE, M.A College
LOSSELESS STARTING METHOD FOR THE WOUND ROTOR INDUCTION MOTOR
LOSSELESS STARTING METHOD FOR THE WOUND ROTOR INDUCTION MOTOR Sergiu Ivanov Mihai Rdulescu University of Craiova, Romania INDA Craiova Faculty of Electrical Engineering 30, Mr#e#ti Street 107, Decebal
Control of a Three Phase Inverter Feeding an Unbalanced Load and Operating in Parallel with Other Power Sources
Control of a Three Phase Inverter Feeding an Unbalanced Load and Operating in Parallel with Other Power Sources Keywords Hauck Matthias, Späth Helmut Elektrotechnisches Institut, Universität Karlsruhe
EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3 OUTCOME 4 - ALTERNATING CURRENT
EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3 OUTCOME 4 - ALTERNATING CURRENT 4 Understand single-phase alternating current (ac) theory Single phase AC
Chapter 24. Three-Phase Voltage Generation
Chapter 24 Three-Phase Systems Three-Phase Voltage Generation Three-phase generators Three sets of windings and produce three ac voltages Windings are placed 120 apart Voltages are three identical sinusoidal
Performance Analysis of Grid connected Wind Energy Conversion System with a DFIG during Fault Condition
Performance Analysis of Grid connected Wind Energy Conversion System with a DFIG during Fault Condition Sasi.C Assistant Professor Department of Electrical Engineering Annamalai University Chidambaram,
Synchronous motor. Type. Non-excited motors
Synchronous motor A synchronous electric motor is an AC motor in which the rotation rate of the shaft is synchronized with the frequency of the AC supply current; the rotation period is exactly equal to
Distributed Flexible AC Transmission System (D FACTS) Jamie Weber. [email protected], 217 384 6330 ext. 13
Distributed Flexible AC Transmission System (D FACTS) Jamie Weber [email protected], 217 384 6330 ext. 13 Slide Preparation: Kate Rogers Davis [email protected], 217 384 6330, Ext 14 2001 South First
Qatar University College of Engineering Electrical Engineering Department. A Graduation Project Report
Qatar University College of Engineering Electrical Engineering Department A Graduation Project Report Design of Power System Stabilizer Based on Microcontroller for Power System Stability Enhancement By
A bidirectional DC-DC converter for renewable energy systems
BULLETIN OF THE POLISH ACADEMY OF SCIENCES TECHNICAL SCIENCES Vol. 57, No. 4, 2009 A bidirectional DC-DC converter for renewable energy systems S. JALBRZYKOWSKI, and T. CITKO Faculty of Electrical Engineering,
Inductors in AC Circuits
Inductors in AC Circuits Name Section Resistors, inductors, and capacitors all have the effect of modifying the size of the current in an AC circuit and the time at which the current reaches its maximum
WIND TURBINE TECHNOLOGY
Module 2.2-2 WIND TURBINE TECHNOLOGY Electrical System Gerhard J. Gerdes Workshop on Renewable Energies November 14-25, 2005 Nadi, Republic of the Fiji Islands Contents Module 2.2 Types of generator systems
BASIC ELECTRONICS AC CIRCUIT ANALYSIS. December 2011
AM 5-202 BASIC ELECTRONICS AC CIRCUIT ANALYSIS December 2011 DISTRIBUTION RESTRICTION: Approved for Pubic Release. Distribution is unlimited. DEPARTMENT OF THE ARMY MILITARY AUXILIARY RADIO SYSTEM FORT
REPORT ON CANDIDATES WORK IN THE CARIBBEAN ADVANCED PROFICIENCY EXAMINATION MAY/JUNE 2008 ELECTRICAL AND ELECTRONIC TECHNOLOGY (TRINIDAD AND TOBAGO)
CARIBBEAN EXAMINATIONS COUNCIL REPORT ON CANDIDATES WORK IN THE CARIBBEAN ADVANCED PROFICIENCY EXAMINATION MAY/JUNE 2008 ELECTRICAL AND ELECTRONIC TECHNOLOGY (TRINIDAD AND TOBAGO) Copyright 2008 Caribbean
PacifiCorp Original Sheet No. 476 FERC Electric Tariff, Substitute 6 th Rev Volume No. 11 APPENDIX 2 TO SGIP
PacifiCorp Original Sheet No. 476 APPENDIX 2 TO SGIP SMALL GENERATOR INTERCONNECTION REQUEST (Application Form) Transmission Provider: Designated Contact Person: Address: Telephone Number: An Interconnection
(3 )Three Phase Alternating Voltage and Current
EEE 2015 EECTRCS (3) Monophase 1 Three phase Three phase electric power is a common method of alternating current electric power generation, transmission, and distribution. t is a type of polyphase system
TDMS Test & Data Management Software
Test & Data Management Software TDMS protective relays energy meters transducers power quality CT-VT-PT transformers ground grid circuit breakers batteries surge arresters The Integrated Testing Solution
Application of GA for Optimal Location of FACTS Devices for Steady State Voltage Stability Enhancement of Power System
I.J. Intelligent Systems and Applications, 2014, 03, 69-75 Published Online February 2014 in MECS (http://www.mecs-press.org/) DOI: 10.5815/ijisa.2014.03.07 Application of GA for Optimal Location of Devices
Control Development and Modeling for Flexible DC Grids in Modelica
Control Development and Modeling for Flexible DC Grids in Modelica Andreas Olenmark 1 Jens Sloth 2 Anna Johnsson 3 Carl Wilhelmsson 3 Jörgen Svensson 4 1 One Nordic AB, Sweden, [email protected].
dspace DSP DS-1104 based State Observer Design for Position Control of DC Servo Motor
dspace DSP DS-1104 based State Observer Design for Position Control of DC Servo Motor Jaswandi Sawant, Divyesh Ginoya Department of Instrumentation and control, College of Engineering, Pune. ABSTRACT This
Genetic Algorithm approach to find excitation capacitances for 3- phase smseig operating single phase loads
Genetic Algorithm approach to find excitation capacitances for 3- phase smseig operating single phase loads Authors & Affiliation: V.Ravi Kiran, V.Manoj and P.Praveen Kumar Asst. Professor, EEE Dept GMRIT,
Current Loop Tuning Procedure. Servo Drive Current Loop Tuning Procedure (intended for Analog input PWM output servo drives) General Procedure AN-015
Servo Drive Current Loop Tuning Procedure (intended for Analog input PWM output servo drives) The standard tuning values used in ADVANCED Motion Controls drives are conservative and work well in over 90%
ELECTRICAL ENGINEERING
ELECTRICAL ENGINEERING The master degree programme of Teacher Training in Electronical Engineering is designed to develop graduates competencies in the field of Curriculum Development and Instructional
Design of Four Input Buck-Boost DC-DC Converter for Renewable Energy Application
Design of Four Input Buck-Boost DC-DC Converter for Renewable Energy Application A.Thiyagarajan Assistant Professor, Department of Electrical and Electronics Engineering Karpagam Institute of Technology
100% Stator Ground Fault Detection Implementation at Hibbard Renewable Energy Center. 598 N. Buth Rd 3215 Arrowhead Rd
100% Stator Ground Fault Detection Implementation at Hibbard Renewable Energy Center Introduction Roger Hedding Steven Schoenherr, P.E. ABB Inc. Minnesota Power 598 N. Buth Rd 3215 Arrowhead Rd Dousman,
Alternative and Renewable Energy Systems
Alternative and Renewable Energy Systems Known as the standard for technical training systems in use across virtually every industry and around the globe, Lab-Volt is now using its expertise to provide
Power Quality Paper #3
The Effect of Voltage Dips On Induction Motors by: M D McCulloch 1. INTRODUCTION Voltage depressions caused by faults on the system affect the performance of induction motors, in terms of the production
Reactive Power and Importance to Bulk Power System OAK RIDGE NATIONAL LABORATORY ENGINEERING SCIENCE & TECHNOLOGY DIVISION
Reactive Power and Importance to Bulk Power System OAK RIDGE NATIONAL LABORATORY ENGINEERING SCIENCE & TECHNOLOGY DIVISION Outline What is Reactive Power and where does it come from? Why is it important?
PHYSICS 111 LABORATORY Experiment #3 Current, Voltage and Resistance in Series and Parallel Circuits
PHYSCS 111 LABORATORY Experiment #3 Current, Voltage and Resistance in Series and Parallel Circuits This experiment is designed to investigate the relationship between current and potential in simple series
Fault Monitoring of the Electric Machine in a Hybrid Vehicle
Fault Monitoring of the Electric Machine in a Hybrid Vehicle Christofer Sundström, Erik Frisk, and Lars Nielsen Vehicular Systems, Dept. of Electrical Engineering, Linköping University, SE-581 83 Linköping,
POWER TRANSMISSION FROM OFFSHORE WIND FARMS
POWER TRNSMISSION FROM OFFSHORE WIND FRMS Thorsten Völker University of pplied Sciences Bremerhaven Germany BSTRCT The future for wind power generation in Germany is offshore wind energy. The preferred
Hybrid Power System with A Two-Input Power Converter
Hybrid Power System with A Two-Input Power Converter Y. L. Juan and H. Y. Yang Department of Electrical Engineering National Changhua University of Education Jin-De Campus, Address: No.1, Jin-De Road,
Microcontroller-based experiments for a control systems course in electrical engineering technology
Microcontroller-based experiments for a control systems course in electrical engineering technology Albert Lozano-Nieto Penn State University, Wilkes-Barre Campus, Lehman, PA, USA E-mail: [email protected]
ELECTRICAL ENGINEERING
EE ELECTRICAL ENGINEERING See beginning of Section H for abbreviations, course numbers and coding. The * denotes labs which are held on alternate weeks. A minimum grade of C is required for all prerequisite
Simulation of VSI-Fed Variable Speed Drive Using PI-Fuzzy based SVM-DTC Technique
Simulation of VSI-Fed Variable Speed Drive Using PI-Fuzzy based SVM-DTC Technique B.Hemanth Kumar 1, Dr.G.V.Marutheshwar 2 PG Student,EEE S.V. College of Engineering Tirupati Senior Professor,EEE dept.
Three phase circuits
Three phase circuits THREE PHASE CIRCUITS THREE-PHASE ADVANTAGES 1. The horsepower rating of three-phase motors and the kva rating of three-phase transformers are 150% greater than single-phase motors
A MULTILEVEL INVERTER FOR SYNCHRONIZING THE GRID WITH RENEWABLE ENERGY SOURCES BY IMPLEMENTING BATTERY CUM DC-DC CONERTER
A MULTILEVEL INVERTER FOR SYNCHRONIZING THE GRID WITH RENEWABLE ENERGY SOURCES BY IMPLEMENTING BATTERY CUM DC-DC CONERTER 1 KARUNYA CHRISTOBAL LYDIA. S, 2 SHANMUGASUNDARI. A, 3 ANANDHI.Y 1,2,3 Electrical
Performance Enhancement of Wound Rotor Induction Motor by VSI with Dynamic Capacitor Controlled Rotor Circuit
Performance Enhancement of Wound Rotor Induction Motor by VSI with Dynamic Capacitor Controlled Rotor Circuit K.Ranjith kumar kumar, Dr.S.Palaniswami K.Priyadharsini, Senior Senior Lecturer Lecturer Professor
RECENTLY, interest in distributed generation systems
IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL 19, NO 6, NOVEMBER 2004 1551 Control of Distributed Generation Systems Part II: Load Sharing Control Mohammad N Marwali, Member, IEEE, Jin-Woo Jung, Student
Synchronized real time data: a new foundation for the Electric Power Grid.
Synchronized real time data: a new foundation for the Electric Power Grid. Pat Kennedy and Chuck Wells Conjecture: Synchronized GPS based data time stamping, high data sampling rates, phasor measurements
Microcontroller based speed control of three phase induction motor using v/f method
International Journal of Scientific and Research Publications, Volume 3, Issue 2, February 2013 1 Microcontroller based speed control of three phase induction motor using v/f method Mrs.DeepaliS.Shirke,
Micro-Step Driving for Stepper Motors: A Case Study
Micro-Step Driving for Stepper Motors: A Case Study N. Sedaghati-Mokhtari Graduate Student, School of ECE, University of Tehran, Tehran, Iran n.sedaghati @ece.ut.ac.ir Abstract: In this paper, a case study
operating under normal conditions supplying - isolated loads - an infinite bus - a fin1 te bus load.
Electrical Equipment - Course 230.2 GENERATORS: PART 8 LOADING 1. INTRODUCTION On completion of this lesson the trainee will be able to: 1. Explain how a small.generator or generators behave when they
REMOTE HOST PROCESS CONTROL AND MONITORING OF INDUSTRY APPLIANCES
REMOTE HOST PROCESS CONTROL AND MONITORING OF INDUSTRY APPLIANCES 1 Abinath.T.R, 2 Sudhakar.V, 3 Sasikala.S 1,2 UG Scholar, Department of Electrical and Electronics Engineering, Info Institute of Engineering,
Test & Data Management Software
Test & Data Management Software TDMS protective relays energy meters transducers power quality CT-VT-PT transformers ground grid circuit breakers batteries surge arresters The Integrated Testing Solution
Basic Electrical Technology Dr. L. Umanand Department of Electrical Engineering Indian Institute of Science, Bangalore. Lecture - 33 3 phase System 4
Basic Electrical Technology Dr. L. Umanand Department of Electrical Engineering Indian Institute of Science, Bangalore Lecture - 33 3 phase System 4 Hello everybody. So, in the last class we have been
Wind Turbine Operation in Power Systems and Grid Connection Requirements
Wind Turbine Operation in Power Systems and Grid Connection Requirements A. Sudrià 1, M. Chindris 2, A. Sumper 1, G. Gross 1 and F. Ferrer 1 1 Centre for Technological Innovation in Static Converters and
Dually Fed Permanent Magnet Synchronous Generator Condition Monitoring Using Stator Current
Summary Dually Fed Permanent Magnet Synchronous Generator Condition Monitoring Using Stator Current Joachim Härsjö, Massimo Bongiorno and Ola Carlson Chalmers University of Technology Energi och Miljö,
Prof. Krishna Vasudevan, Prof. G. Sridhara Rao, Prof. P. Sasidhara Rao
6 Synchronous motor 6.1 Principle of operation In order to understand the principle of operation of a synchronous motor, let us examine what happens if we connect the armature winding (laid out in the
Keywords: Self-Excited Induction Generator (SEIG), Single Phase Synchronous D-Q Frame Theory, Static Synchronous Compensator (STATCOM).
ISSN 2319-8885 Vol.04,Issue.20, June-2015, Pages:3756-3762 www.ijsetr.com Power Quality Improvement by using STATCOM for Three-Phase Loads MANJULA VIJAYALAKSHMI 1, M. PRAVEEN KUMAR 2 1 PG Scholar, Dept
300 MW Variable Speed Drives for Pump-Storage Plant Application Goldisthal
May 24 MW Variable Speed Drives for Aurélie Bocquel APCG / 4BOC4 (MW-Goldisthal 1-5-24).PPT MW Variable Speed Drives for Content Major benefits of the cyclo-converter driven doubly-fed induction machines