Boss Water Systems Australia Reverse Osmosis System Model 021-4P

Similar documents
Simply complete the enclosed Warranty Form with contact details, or us with your details and date of purchase.

Watts Pure Water Systems

How To Replace A Reverse Osmosis Water Tank

Installation Instructions

Thank you... Welcome to your new world of better living with water2buy s Aquasmart Reverse Osmosis water. How your Reverse Osmosis unit works

RPlus. Installation & Service Manual. 5-Stage Reverse Osmosis Drinking Water System. Plus

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

AQUAPRO INDUSTRIAL CO.,LTD. Reverse Osmosis Parts Introduction

PURE WATER. Installation, Operation and Maintenance Manual. Kwik-Change Reverse Osmosis System Model PWROKC4. Important.

Installation and Operation Manual

Whole House Water Treatment System. Installation, Operation and Maintenance Manual. Multi-Pure Model TO15000

Stenner Pump Chlorinator Installation & Start Up Guide

R.O. DRINKING WATER SYSTEM MODEL

Aqua-Pure AP-RO5500 Reverse Osmosis Drinking Water Filtration System

Installation Instructions S

Installation Instructions

Installation guide Nordic mixer taps. Before installing read this guide first

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

STABITHERM INSTALLATION & SERVICE BOOKLET

Reverse Osmosis (RO) Drinking Water System. Product Manual

4 Stage Barracuda RO/DI Instruction & Owner s Manual

Assembly and instructions

3M Water Filtration Products. CFS01 Series, CFS02 Series, CFS11 Series, and CFS12 Series Housings. Installation and Instruction Manual For:

INSTRUCTIONS MANUAL PROLINE PLUS PROLINE PLUS PUMP

INSTALLATION & SERVICE MANUAL

INSTALLATION & SERVICE MANUAL

SECTION 11 drinking Water Systems

Reverse Osmosis. Drinking Water Systems. Installation Manual

Fixtures - Parts - Accessories to shampoo bowls

HYDROTECH ADVANCED REVERSE OSMOSIS WATER TREATMENT SYSTEMS

VOYAGER 570G. 744A Sprayer Control

B150 Series Commercial Brewer. Direct Plumb Kit

8 plumbing. plumbing PulteGroup, Inc. All Rights Reserved.

Providing Temperature. Regulated Warm Water. to your Sanicare. Hand Spray Bidet

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual

STAINLESS STEEL TANK TABLE OF CONTENTS TROUBLESHOOTING... 1 TESTING WATER TEMPERATURE... 3 TANK & JACKET ASSEMBLY... 4.

AMX300 DirectConnect Mixing Valve Kits

GE SmartWater INSTALLATION INSTRUCTIONS. Heavy Duty Water Filtration System GNWH38F SAFETY PRECAUTIONS PROPER INSTALLATION

Pro-OX 7800 Iron Filter Installation & Start-Up Guide

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

TWO-WAY DIVERTER WITH THREE-WAY HAND SHOWER

Line to Refrigerator Ice/Water Dispenser

Treatment options for hydrogen sulfide. Testing for hydrogen sulfide

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

A3650/11LMWS (Metal Lever) A3650/11LPWS (Porcelain Lever)

OWNER S MANUAL. FOOTWORKS tm Faucet Controller. Foot Operated Faucet Control Valves for Commercial Sinks

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Water Treatment and Reverse Osmosis Systems

Chill 4 Hole Bath Shower Mixer

Iron Air Charge 2510-SXT Installation & Start-Up Guide

Porcelain Vessel Sink Installation


WIRELESS REMOTE ASSEMBLY, 24VDC, 1 TRANS,1 REC

Installation Instructions AQ-5100, AQ-5200 & AQ-5300 Under Counter Water Filter Single Stage (5100), Two Stage (5200) and Three Stage (5300) systems

Air Conditioner Water Heater Model ACWH18

D-Series Economy Reverse Osmosis Systems

Traditional Sonar and DSI Sonar Installation

Your safety and the safety of others are very important.

Use of Nano-scale materials in Water Purification

Installation Instructions

Culligan Good Water Machine Drinking Water System Owners Guide

UNIT 7: PLUMBING KEY CONCEPTS. 1. Identify tools for plumbing. 2. Location of shutoff valves for the main and individual fixtures

PLUMBING CARE AND REPAIR

MAC FAUCETS. Owner s Manual. Models: FA444

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS BL-8704

Water Treatment Filtration Lab. discharged into an aquatic ecosystem? We had to build a water filtration system with

DC Water. household water quality guide. dcwater.com district of columbia water and sewer authority. George S. Hawkins, General Manager

PWC-500/1000/1010/1500

Model 5600 & 5600 Econominder

Indiana Department of Environmental Management. Well Disinfection

Triac Printed Circuit Board Replacement

LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

1.8 CRANKSHAFT OIL SEALS

Lenntech psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503

SunMor SM-V30 Solar Water Heater Installation Manual

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250/F-350 Single Wheel 2WD Ford F350 Dually 2WD IMPORTANT NOTES

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Wastewater Reuse. Typical treated wastewater is:

Geyser-R Heat pump water heater Installation manual

Bacteria Control Troubleshooting Guide for Automated Watering Systems

Thermo Scientific Barnstead TII Pure Water Systems. Pure water. Pure research. Total confidence.

VIPCLEAN Via Goretta 96/A Mappano di Caselle (TO) Tel Fax

Installation Instructions / Warranty

INSTALLATION INSTRUCTIONS MK-8704

Providing Temperature. Regulated Warm Water. to your Sanicare. Hand Spray Bidet

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

Water Treatment & Purification Chemicals

Complete. Water Solutions. for Rural India

Industrial Strength Rocket Launcher

Restoring bore pump performance

OWNER S GUIDE ADVANCED REVERSE OSMOSIS WATER TREATMENT SYSTEMS MODEL SERIES MODEL SERIES MODEL SERIES MODEL SERIES 12304

Model 5600 & 5600 Econominder

A meaningful, cost-effective solution for polishing reverse osmosis permeate

VERTEX OWNERS INSTALLATION MANUAL. Water Dispenser. Water Products PureWaterCooler VERTEX WATER PRODUCTS

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Transcription:

Boss Water Systems Australia Reverse Osmosis System Model 021-4P Congratulations on your purchase of the most advanced water purifier system available! Installation and Service Guide short web version, this is not the instruction manual you will receive with your purchase of a PSI-021-4P but a shortened version that is available on our web site, it is a shorter version due to other suppliers likely to copy this instruction manual as their own.

REVERSE OSMOSIS WATER PURIFIERS Of all the water purifier system types on the market by far the most superior is the reverse osmosis process. Reverse osmosis works by forcing water through a membrane, if the water molecule is small enough it will pass across the membrane material and into the product line (pure water). A water molecule is 2 parts hydrogen and 1 part oxygen (H2O) but if a molecule had extra atoms attached the molecule is larger and won t pass through the membrane and is rejected, the contaminated molecule then goes into the waste line and is ejected from the system. The term waste water is not a kind way of describing the contaminated (waste) water that is rejected by the reverse osmosis as it is water that is contaminated in some way and not simply waste as such, the reverse osmosis process is a selection process, if the water molecule is pure it will pass into the pure water part, anything else is rejected. The reverse osmosis process is the best water purity of any type of process and is similar to Distillation but distilled water is almost devoid of oxygen and tastes flat and dead, reverse osmosis water process actually adds oxygen to the water resulting in extremely pure sweet tasting water with almost all the poisons and impurities removed. Waste Water The PSI-021-4P is designed for simple installation and operation and is well within the abilities of a home handyman to maintain, the filters should be changed at the recommended service intervals to maintain continual un-troubled service life. Operating parameters System Pressure 300 to 600 kpa (40 to 87 psi) PH range 3.0 to 11.0 Maximum Supply TDS level (low waste 500 mg/l = 500 ppm TDS units) Temperature 2 to 40 degrees Turbidity <1.0 Net Turbidity (NTU)

Caution This Reverse Osmosis system is designed for operation on microbiologically safe water which is usually Chlorinated mains water supplies, this system is not suitable for installation on Un-Chlorinated water supplies, contact your selling agent to have a UV steriliser added for microbiologically unsafe water such as Tank, Dam or Bore water. Pressurised Storage Tank Membrane Flushing Valve/ Flow Restrictor Reverse Osmosis Membrane Stage 3 Sediment Filter Stage 1 Carbon Post Filter stage 4 Carbon Filter Stage 2 Stage 1 Sediment pre-filter, this filter is a 1 micron polyspun sediment filter cartridge for mechanical removal of Grit, dust, Rust, mud, algae ect. This cartridge is normally replaced every 12 months but if dirty mains water is encounted more frequent change may be required. Stage 2 Carbon pre-filter, this filter is a high grade carbon block cartridge to protect the membrane from chlorine which can damage a TFC (thin film composite) membrane, this carbon cartridge will also assist the membrane by removing THMs, TCEs, pesticides and other organic pollutants. This cartridge is usually changed every 12 months unless very dirty from the mains supply is encountered or very heavy usage.

Stage 3 This is the membrane which is the main filter in a reverse osmosis system, pore size is less than 0.0005 micron, the membrane is a thin film composite, NSF stand 42, 53 and 58, normal replacement is usually between 3 to 5 years. Stage 4 This is the carbon polishing post filter which provides final filtration to provide superb tasting clean water. Normal replacement is 12 months. Installation Select a suitable location avoiding locations where the system could come into contact with things like hot water pipes, also consider ease of maintenance. Check where the faucet (tap) will be installed looking at things like possible damage to pipes and electrical wires when drilling, choose a location that will be the most convenient for use. Choose a location for the storage tank, the tank can be more remote than the main filter system, a back corner cupboard is often used, the tank tube line is 1.8 metres, try to have as short a tube to the tank and faucet as practicable because the shorter the tube the faster the flow will be. All tube is colour coded for installation ease Blue tube connects from the mains supply to the entry point of the unit. Yellow tube connects the main filter unit to the storage tank. The black line connects the main filter unit for waste to the sink drain, this waste line can be run outside to be collected for use in the garden. The white line connects the main filter unit to the faucet (tap) The mains connection best suited to your installation will have been selected at the time of ordering, separate instructions are supplied with the mains connection kit, use the supplied plumbers thread tape on all threaded joints, connect to cold water mains supply only. Faucet Installation The RO water faucet may be installed on any flat surface at up to 50 mm [2 ] in diameter. Check the underside of the location for interference.

Determine desired location for the faucet on your sink surface. A. Place a piece of masking tape or duct tape on location where the hole is to be drilled. Mark the centre of the hole on the tape. B. Using a variable speed drill on the slowest speed, drill a 1/8 (3 mm) pilot hole at the centre of the desired location. C. Enlarge the hole to ¼ (6 mm). Keep the drill speed on the slowest speed. D. Enlarge the hole to 7/16 th to ½ (11 to 13 mm) Keep the drill speed on the slowest speed. E. Pass the Escutcheon plate (chrome washer) and large black washer over the threaded mounting tube at the base of the faucet. F. From top of sink, slide the threaded mounting tube through the hole drilled in the sink. Align the faucet body. G. From under the sink, slide the smaller rubber washer on the threaded part of the faucet first, then the plastic washer, locking washer and then the thin threaded nut, Tighten with a spanner. Holding the tube from the filter system, place the brass cup nut on first, then the nylon olive and then insert the nylon thimble into the end of the tube as far as it will go. Insert the tube into the base of the threaded part of the faucet, push it in firmly (about ¼ ) and slide nut up to thread and tighten firmly, do not over tighten. Storage Tank Place storage tank in a convenient position. Tank can be placed on its stand, either upright or on its side. Activating the System For the First Time First open the Faucet, turn Feed Water Valve counter clockwise until fully open. Check plumbing kit assembly for leakage. Make sure all water supply/drain lines are secure and free from leakage. Turn storage tank valve one quarter turn counter clockwise to open the valve [the handle should be in line with the tubing as it enters the connection] Let the water flow out the Faucet until all the air has been expelled from the system. Water will be slightly discoloured [non-toxic carbon fines] and have some aeration. This will take about 15 minutes. Close the RO water faucet. In 15 minutes, check the connections for leaks and correct if necessary. Allow the tank to fill, this should take about 1 hour, open the faucet and drain the tank, this process is repeated a second time. The membrane contains a food grade preservative which prevents the membrane from bacteria in shipping and storage, the process of draining the tank twice is only done when the system is new or a new membrane is installed, this process expels the preservative.

Flush valve maintenance. This unit is fitted with a membrane-flushing valve and is normally closed. About once a month Turn the Faucet on and drain the tank, at the same time turn the small red or blue valve at the front of the unit to the open position and leave it on for about 10 minutes to clear any possible build-up of particles, failure to do this will shorten membrane life. This flush valve needs to be operated when the tank is filling, if you open the valve and nothing happens the system is in shut down mode, release some water from the faucet to start the unit filling again and open the flushing valve again. Drain the tank as part of the membrane flushing process. When this valve is in the closed position it operates as a flow restrictor. As stated earlier this is a web version of our installation instructions, a full printed version is supplied in your system with more detail.