E3X-NT11 E3X-NT21 E3X-NM11

Similar documents
Color Mark Sensor with Red or Green LED E3S-VS

Universal Voltage Terminal Photoelectric E3JM

E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity

Fiber-Optic Photoelectric Sensor

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm

Capacitive Prox E2K-X

Absolute Rotary Encoder E6CP

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Incremental Rotary Encoder E6B2

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Cross-beam scanning system to detect slim objects. 100 mm in

Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option

W 36: Mastering complex tasks reliably

How To Read A Pipe From A Sensor

BOS 73K... BOS 74K...

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

Optical Fiber Photoelectric Sensor

W150: Miniature photoelectric switch series with completely integrated electronics

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

technical data (according to IEC )

Solid-State Timer H3G

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Type Supply voltage Output Connection Sensing range Standard target Timer function Part number Polarized VDC NPN/PNP Pre-leaded 500 mm to 10 m

SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Smart Sensing Solutions Since 1954

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

intelligent solutions

Smart DeviceNet Remote I/O Terminals

W 160: Miniature series for optimum solutions

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

LM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs

photoelectric highlights

Electrical connection

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Liquid Leakage Sensor Amplifier

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

LUT Luminescence scanners: Seeing what no-one else can

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Bar Code Label Detection. Size and Edge Detection APPLICATIONS

Ordering Information. Short Barrel Inductive Prox E2E3-WIREDC. Short Barrel 3-Wire Prox Sensors Meet IP67

Multifunction devices

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Product and functional description

Liquid Level Limit Switch liquiphant T FTL 20

GST301. (Single Protection Zone) Operation Manual

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2010

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Quick Connect. quick - simple - efficient.

Safety technique. Emergency stop module BO 5988 safemaster

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

38 Series - Relay interface modules A

38 Series - Relay interface modules A

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

Inductive Proximity Sensors

MULTI-BEAM LS10 Light Screen System

Multifunction Digital Timer

WD-AMX Water Detection Controllers

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Count input Display Time range h or 3999d23.9h (selectable) 999h59m59s or 9999h59.9m (selectable) 3. Case Color B: Black

Intersection Preassembled 19-inch Rack

Speed Control Relays SX2

40.3. Control Relays and Timers

I STAR COMPUTER CO., LTD

pre-wired E3FC-TN11 2M *1 E3FC-TP11 2M *1

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Solid State Timers Type F

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Preset Counter signo 721

80 Series - Modular timers 16 A. Features

Inwall 4 Input / 4 Output Module

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

TRANSISTOR/DIODE TESTER

Type Contact material Contact form Construction Model General purpose AgCdO SPDT Semi-sealed G2R-1

Transcription:

R Auto-Tuning Fiber-Optic Sensor High Performance DC Amplifier with Pushbutton Sensitivity Adjustment H tenance is made easier with pushbutton sensitivity adjustment H Sensing distance is up to 100% longer than standard amplifiers H Choose either single channel or four channel models H Compact housing: 32 mm and 10 mm housing widths H Four amplifiers in a single housing saves space and wiring H Four fiber-optic cables can be mounted directly next to each other without mutual interference Ordering Information J AMPLIFIERS Type Single channel Four channel Off-delay timer None Provided Provided Remote teach input None Provided Provided Part number NPN T11 T21 M11 PNP T41 T51 M41 J FIBER-OPTIC CABLES Please see the E32 Fiber-Optic Cables section. J ACCESSORIES Description Replacement protective cover for Tjj Replacement protective cover for Mjj Part number E39-G8 E39-G9 2

Specifications Description General-purpose Multi-function Four-channel Part number NPN T11 T21 M11 Supply voltage PNP T41 T51 M41 12 to 24 VDC ±10%, 10% ripple max. Current consumption 50 ma max. 150 ma max. Required fiber-optic cables Light source mode Sensitivity Mutual interference protection Please see the E32 Fiber-Optic Cables section. Pulse modulated red LED (680 nm) Light-, Dark- (switch selectable) Pushbutton setting (see operation section) Provided Remote teach option Provided DC solid state Type NPN open collector PNP open collector Max. load 100 ma, 30 VDC max. Max. -state voltage drop 1 VDC max. at 100 ma Response time 500 µs max. at rated detection distance Timing functions OFF: delay, 40 ms, selectable or OFF Circuit protection Teaching confirmation function Indicators Materials Case PBT plastic Mounting Cover Output short protection, DC power reverse polarity protection Indicators (red/green LED) and buzzer (orange LED) and stability (green LED) Polycarbonate DIN-rail track, or on flat surface through holes in bracket (provided) Connections Pre-leaded 3 conductor cable, 4 conductor cable, 7 conductor cable, 2 m (6.5 ft) 2 m (6.5 ft) 2 m (6.5 ft) Weight Enclosure ratings UL NEMA IEC Approvals UL Ambient temperature CSA 100g(3.5oz.)with2mcable IP 50 (with cover on) Operating: --25 C to 55 C (--13 F to 131 F) with no ice buildup Storage: --40 C to 70 C (--40 F to 158 F) 3

J OUTPUT CIRCUIT DIAGRAMS T11 T21 Teaching Teaching 12 to 24 VDC Pink 12 to 24 VDC Remote teaching input M11 x4 x4 Teaching White Grey Orange 12 to 24 VDC Channel no. 1 2 3 4 wire color White Grey Orange Pink Remote teaching input T41 T51 Teaching 12 to 24 VDC Teaching Pink Remote teaching input 12 to 24 VDC M41 x4 x4 Teaching Pink White Grey Orange Remote teaching input 12 to 24 VDC Channel no. 1 2 3 4 wire color White Grey Orange 4

Nomenclature T11 (NPN) T21 (NPN) T41 (PNP) T51 (PNP) M11 (NPN) M41 (PNP) Teaching Teaching button Four operation s Four stability s Channel selector Mode selector Timer switch (see note) mode selector Teaching button Teaching mode selectors Note: The T11 or T41 do not have a timer function. Mode selector J CHOOSING THE RIGHT ING METHOD Refer to the following table to select the most suitable sensitivity setting method. Teaching method Maximum sensitivity setting No-object teaching With/Without-object teaching Typical application Detection of the existence of objects that interrupt light perfectly If teaching is impossible by stopping the movement of sensing objects Detection of a slight difference in reflection Detection of objects with no background objects To detect bright or dark objects by teaching only with background objects Elimination of background object influence Color discrimination Background objects with unstable reflection Detection of object surface irregularities Note: 1. None of the four channels has any when the M (four channels) is in teaching mode (i.e., all the four channels will be in teaching mode). 2. If the set distance is very short (i.e., 0 to 12 mm for the E32-TC200 and 0 to 4 mm for the E32-DC200), no-object teaching is not possible due to excessive light, in which case, perform with/without-object teaching. 3. In principle, use the M (four channels) for the close connection of a maximum of four Fiber Units. When closely connecting two to three Fiber Units to more than one T (one channel), perform with/without-object teaching, in which case teaching must be performed on a single T at a time. Therefore, turn on only the T on which teaching is performed. If all the Ts are turned on, interrupt the emitters of the Fiber Units on which teaching is not performed. 5

J MAXIMUM SENSITIVITY TING Note: The sensitivity of the T and M are set to maximum before shipping. When resetting the sensitivity of the T or M to maximum after no-object teaching or with/without-object teaching, follow the steps described below. Procedure T M 1 Locate the sensor head within the rated sensing range with the j. 2 Set the mode selector to. 3 The flashing function of the j will be activated. Therefore, adjust the optical axes so that the tip of the emitting fiber will be lit. If the optical axes are divergent, the tip of the emitting fiber will flash and the built-in buzzer of the j will beep. 4 Press the teaching button for three seconds minimum with or without a sensing object. In the case of the M, select a channel with the channel selector, at which time the stability for the selected channel will flash. The teaching (red) turns green. The built-in buzzer beeps once when the color of the teaching is red. The built-in buzzer beeps continuously when the color of the teaching is green. Note: The built-in buzzer will stop beeping when the teaching button is no longer being pressed. 5 Set the mode selector to to complete the sensitivity setting. The teaching is OFF. Note: When the sensitivity is set to maximum, the sensitivity will be automatically adjusted regardless of the set distances of the fibers or light. 6 Select the logical required with the operation mode selector. L --- D CH L D 1 2 3 4 6

J WITH/WITHOUT-OBJECT ING Procedure T M 1 Locate the sensor head within the rated sensing range with the j. 2 Set the mode selector to. 3 The flashing function of the j will be activated. Therefore, adjust the optical axes so that the tip of the emitting fiber will be lit. If the optical axes are divergent, the tip of the emitting fiber will flash and the built-in buzzer of the j will beep. 4 Locate a sensing target in the sensing area and press the teaching button once. In the case of the M, select a channel with the channel selector and press the teaching button, at which time the stability for the selected channel will flash. Through-beam Model Reflective Model Reflective Model --- --- Mark Light is interrupted. Base The teaching (red) is lit. The built-in buzzer beeps once. 5 Move the object and press the teaching button. Through-beam Model Reflective Model Reflective Model Mark Light is received. Base If teaching is OK: The teaching (red) turns green. The built-in buzzer beeps once. If teaching is NG: The teaching (red) starts flashing. The operation also starts flashing. (M) The built-in buzzer beeps 3 times. Change the position of the object and the sensing distance that have been set and repeat from the beginning. 6 Set the mode selector to to complete the sensitivity setting. The teaching is OFF. 7 Select the logical required with the operation mode selector. L D CH L D 1 2 3 4 Note: 1. Even if the j is turned off, the j will retain the sensitivity set at the time of teaching. 2. Channels (M) are selected in the following order. When all the channels are selected, it is possible to set the sensitivity of the M on all channels. 1CH 2CH 3CH 4CH ALL 7

J NO-OBJECT ING Procedure T M 1 Locate the sensor head within the rated sensing range with the j. 2 Set the mode selector to. 3 The flashing function of the j will be activated. Therefore, adjust the optical axes so that the tip of the emitting fiber will be lit. If the optical axes are divergent, the tip of the emitting fiber will flash and the built-in buzzer of the j will beep. 4 Press the teaching button for 0.5 to 2.5 seconds without a sensing object. In the case the M, select a channel with the channel selector and press the teaching button, at which time the stability for the selected channel will flash. The teaching (red) is lit. The built-in buzzer beeps once. --- 5 Set the mode selector to. No-object teaching will be set when the first sensing object passes through the sensing area. The teaching (red) turns green (automatically turned off in one second). 6 Select the logical required with the operation mode selector. L D CH L D 1 2 3 4 Note: 1. To detect dark objects in front of bright backgrounds, set the operation mode selector to D.. 2. If the set distance is very short (i.e., 0 to 12 mm for the E32-TC200 and 0 to 4 mm for the E32-DC200), no-object teaching is not possible due to excessive light, in which case, perform with/without-object teaching. 3. If the teaching button is pressed for more than three seconds, the sensitivity of the j will be set to maximum, at which time the green will be lit. 4. The j will be ready to detect objects in approximately one second after the mode selector is set to. J SENSITIVITY ADJUSTMENT Combination of the T/M and Fine Through-beam Fiber Units (E32-T22S/T24S/T84S) No-object Teaching Press the teaching button once with no object in the sensing area. Object Note: If detection is not stable after no-object teaching, perform with/without-object teaching. With/Without-object Teaching Press the teaching button once with no object in the sensing area. 8

NOTE: DIMENSIS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. R OMR ELECTRICS LLC One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMR OMR -LINE Global -- http://www.omron.com USA -- http://www.omron.com/oei Canada -- http://www.omron.com/oci OMR CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Cat. No. CEDSAX4 11/01 Specifications subject to change without notice. Printed in U.S.A.