THE USE OF THE COEFFICIENT OF VARIATION FOR COMPARISON OF FORCE-TIME CURVES FROM HANDGRIP TESTS

Similar documents
MEASURES OF VARIATION

Content Sheet 7-1: Overview of Quality Control for Quantitative Tests

Guidelines for publishing manuscripts

Impacts of Demand and Technology in Brazilian Economic Growth of

Basic gait parameters : Reference data for normal subjects, years of age

Marcio J. Santos, P.T., Ph.D.

This unit will lay the groundwork for later units where the students will extend this knowledge to quadratic and exponential functions.

Means, standard deviations and. and standard errors

INTRODUCING THE NORMAL DISTRIBUTION IN A DATA ANALYSIS COURSE: SPECIFIC MEANING CONTRIBUTED BY THE USE OF COMPUTERS

Pie Charts. proportion of ice-cream flavors sold annually by a given brand. AMS-5: Statistics. Cherry. Cherry. Blueberry. Blueberry. Apple.

Ergonomics and Repetitive Strain Injury

TEXTO PARA DISCUSSÃO N 265 ECONOMIC GROWTH, CONVERGENCE AND QUALITY OF HUMAN CAPITAL FORMATION SYSTEM. Luciano Nakabashi Lízia de Figueiredo

The Solar Radio Burst Activity Index (I,) and the Burst Incidence (B,) for

1) Write the following as an algebraic expression using x as the variable: Triple a number subtracted from the number

TEACHING CALCULUS USING E-LEARNING IN A MOODLE PLATFORM

Session 7 Bivariate Data and Analysis

Six-servo Robot Arm. DAGU Hi-Tech Electronic Co., LTD Six-servo Robot Arm

Business Statistics. Successful completion of Introductory and/or Intermediate Algebra courses is recommended before taking Business Statistics.

How to Verify Performance Specifications

2. Filling Data Gaps, Data validation & Descriptive Statistics

Statistical Confidence Calculations

Week 4: Standard Error and Confidence Intervals

Introduction to Quantitative Methods

Simple linear regression

STATS8: Introduction to Biostatistics. Data Exploration. Babak Shahbaba Department of Statistics, UCI

Real sport for fit men and women!

Hirsch s index: a case study conducted at the Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo

THE ISSUE OF PERMANENCE AT AN ONLINE CLASS: an analysis based upon Moodle platform s accesses

Statistical estimation using confidence intervals

Institute of Actuaries of India Subject CT3 Probability and Mathematical Statistics

99.37, 99.38, 99.38, 99.39, 99.39, 99.39, 99.39, 99.40, 99.41, cm

DETERMINATION OF THE EFFECTIVE VOLUME OF AN EXTRAPOLATION CHAMBER FOR X-RAY DOSIMETRY

Chapter 10. Key Ideas Correlation, Correlation Coefficient (r),

Schools Value-added Information System Technical Manual

business statistics using Excel OXFORD UNIVERSITY PRESS Glyn Davis & Branko Pecar

2013 MBA Jump Start Program

Probability Distributions

The Need of Continuous Teachers Training in the Coaching of Vocational Education 1

Descriptive Statistics

Fairfield Public Schools

12/15-Lead ECG Protocol approved October 2005 revised October 2008

Multifocal Motor Neuropathy. Jonathan Katz, MD Richard Lewis, MD

Business Information Management I

DESCRIPTIVE STATISTICS AND EXPLORATORY DATA ANALYSIS

Author: Dr. Society of Electrophysio. Reference: Electrodes. should include: electrode shape size use. direction.

MBA 611 STATISTICS AND QUANTITATIVE METHODS

Using R for Linear Regression

THE SIX SIGMA BLACK BELT PRIMER

Course Text. Required Computing Software. Course Description. Course Objectives. StraighterLine. Business Statistics

Industry Environment and Concepts for Forecasting 1

Dr. Enas Elsayed. Brunnstrom Approach

2 Describing, Exploring, and

The Role of SPOT Satellite Images in Mapping Air Pollution Caused by Cement Factories

PELLISSIPPI STATE COMMUNITY COLLEGE MASTER SYLLABUS INTRODUCTION TO STATISTICS MATH 2050

Muscle Physiology. Lab 5. Human Muscle Physiology

Injuries from lifting, loading, pulling or pushing can happen to anyone in any industry. It is important to be aware of the risks in your workplace.

TImath.com. F Distributions. Statistics

Chapter 2: Frequency Distributions and Graphs

CONNECTING LESSONS NGSS STANDARD

DESCRIPTIVE STATISTICS. The purpose of statistics is to condense raw data to make it easier to answer specific questions; test hypotheses.

Section A. Index. Section A. Planning, Budgeting and Forecasting Section A.2 Forecasting techniques Page 1 of 11. EduPristine CMA - Part I

Measurement & Data Analysis. On the importance of math & measurement. Steps Involved in Doing Scientific Research. Measurement

Chapter 5 Analysis of variance SPSS Analysis of variance

Gait with Assistive Devices

Wingz Ergonomic Computer Keyboard An overview of research leading to a new keyboard design

2013 MBA Jump Start Program. Statistics Module Part 3

Introduction; Descriptive & Univariate Statistics

Directions for Frequency Tables, Histograms, and Frequency Bar Charts

Data Interpretation QUANTITATIVE APTITUDE

Case Study in Data Analysis Does a drug prevent cardiomegaly in heart failure?

Athletics (Throwing) Questions Javelin, Shot Put, Hammer, Discus

3.2. Solving quadratic equations. Introduction. Prerequisites. Learning Outcomes. Learning Style

Public Funding and the Beginning of a New Era in Higher Education in Brazil

Hemiplegic shoulder pain/shoulder subluxation

Science popularization actions for teaching food science and technology in Rio de Janeiro state*

Schneps, Leila; Colmez, Coralie. Math on Trial : How Numbers Get Used and Abused in the Courtroom. New York, NY, USA: Basic Books, p i.

Laboratory Guide. Anatomy and Physiology

Exploratory data analysis (Chapter 2) Fall 2011

PROPERTIES OF THE SAMPLE CORRELATION OF THE BIVARIATE LOGNORMAL DISTRIBUTION

Passive Range of Motion Exercises

Descriptive Statistics

Biomedical Engineering Undergraduate Courses

BASIC ELECTRONICS AC CIRCUIT ANALYSIS. December 2011

3. What is the difference between variance and standard deviation? 5. If I add 2 to all my observations, how variance and mean will vary?

Describing, Exploring, and Comparing Data

Advanced Topics in Statistical Process Control

CHAPTER THREE COMMON DESCRIPTIVE STATISTICS COMMON DESCRIPTIVE STATISTICS / 13

Exercise and FES cycle fact sheet

An introduction to Value-at-Risk Learning Curve September 2003

New Method for Optimum Design of Pyramidal Horn Antennas

4.1 Exploratory Analysis: Once the data is collected and entered, the first question is: "What do the data look like?"

Sample lab procedure and report. The Simple Pendulum

Check List for identifying Special Needs Children among School age children. Cerebral Palsy

Education & Training Plan. Accounting Math Professional Certificate Program with Externship

Irrational Numbers. A. Rational Numbers 1. Before we discuss irrational numbers, it would probably be a good idea to define rational numbers.

NCSS Statistical Software Principal Components Regression. In ordinary least squares, the regression coefficients are estimated using the formula ( )

MULTIPLE REGRESSION WITH CATEGORICAL DATA

SENSITIVITY ANALYSIS AND INFERENCE. Lecture 12

Module 3: Correlation and Covariance

Transcription:

VI International Conference on Computational Bioengineering ICCB 2015 M. Cerrolaza and S.Oller (Eds) THE USE OF THE COEFFICIENT OF VARIATION FOR COMPARISON OF FORCE-TIME CURVES FROM HANDGRIP TESTS JOSÉ MARQUES NOVO JR. *, RENATO DE SOUZA LIMA JR. AND CAIO SADAO MEDEIROS KOMINO * Laboratory of Innovation and Entrepreneurship for Assistive Technology, Sport and Health Physical Education Department - Federal University of São Carlos-UFSCar Rodovia Washington Luis, km235/sp310 CEP:13565-905 São Carlos/SP/Brazil e-mail: marques.novojr@ufscar.br web page: http://www.ufscar.br Graduate Inter Bioengineering Program - São Paulo University-USP São Carlos/SP/Brazil email: renatosljf@hotmail.com, caio.komino@usp.br Key words: Force-time curves, coefficient of variation, curve comparison, handgrip tests, biomechanic method Abstract. The aim of this study was identify some characteristics of the Variation Coefficient (CV) applied to the force-time curves obtained from six handgrip tests (5s isometric test) with four subjects. This work shows the CV within the 0-1s interval, which holds the maximum force value. The CV values are arranged as a time series data, and the analysis are made by two steps: with all curves and without an anomalous curve, identified by graphical criteria. The CV s are graphically exhibited and their lowest values were considered for measuring similarities of the curves. Thus, these procedures indicate that the mean curve is the best parameter for representing the performance of the subject in the handgrip test. 1 INTRODUCTION Different methodologies, aiming at a higher reliability on the analysis of the data obtained in evaluation tests on muscular force (both quantity and qualitatively), are mentioned in this field literature. Among these mentions, we can quote the exploratory analysis through graphic methods [1], [2]. Recently, some studies that explore graphic tools of diagnosis have been applied to these signs, such as: the force-time chart itself, the differentiation and mitigation procedures, the function of autocorrelation and mathematical models identification [3], [4]. [5], [6], [7]. However, the adjustment of these models to the signs of force hasn t been enough to identify similarities or verisimilitude of force-time curves. The use of Coefficient of Variation (CV), determined by the relation between the standard patterns and its respective mean values, has been proposed by WINTER [8] and also verified in other areas [9] as well as in investigations of this sort of data in the sense of making possible to compare and to estimate the accuracy of experiments. In order to do so, it has been common the use of limits the distribution of the CV values as follows: low (<10% or x +s), mean (between 10% and 20% or x -s<cv x +s), high (between 20% and 30% or x +s<cv x +2s), very high (above 30% or CV x +2s). According to GILL [9], CV values are pertinent within the ratio from 5 to 50% and values below 1% are rare.

This study proposes to apply the CV definition to each instant of the force signs (time series) focusing at identifying the behavior of this series in relation to the force-time curves and to the limits of its distribution. 2 MATERIALS AND METHODS The data used in this study have been obtained through the following protocol: sitting subject and previous warming up of the hand and the arm involved. Subject with their shoulder in an ordinary position (90 elbow, neutral position of the wrist, forearm supported by the chair which us appropriated to the tests.) Following the commands of the researcher, the subjects executes a maximum voluntary contraction of the hand (clench mode) for up to 5 seconds. Six attempts were conducted with intervals of 1.5 minute. The force-time curves were obtained from each one of these attempts. The signs were sampled at a frequency of 420 Hz with 4 healthy subjects without any lesion, trauma or pathology in their tested hands. The subjects were 2 men and 2 women, (24.5 ± 3.1 years old). From the curves obtained during the tests was identified the point of initial effort for each curve, immediately after the stage of pre-load (the load corresponding to the value at t=0s, Figure 1), using the technique proposed by Amaral et al. [10,11]. The CV definition was applied to the force-time curves, which represents the standard pattern as a percentage of the mean and that is calculated using the following formula: st CV t = 100 xt where s is the square root of the residual variance and x is the value mean of the force in all the curves, at every t instant. For more signs of force used, it has been estimated the mean values, standard deviation and coefficient of variation for each instant of time which resulted in time series of 420 samples (during one second). The estimates of the series have been obtained in two steps: the first one using all signs of force and the second being apart from one of the six curves for each subject that had less visual similarity (different form from the rest) so it could be possible to ascertain possible changes in the behavior of the CV curves. 3 RESULTS AND DISCUSSION The charts shown correspond to one of the subjects part of this test. The procedures for the identification of the CV curves features are presented in the figures and were equally applied to the data of every volunteer. Figure 1 presents the six signs obtained in the tests performed displaying the values of force in the rapid phase (0 to 1 second period). It can be seen that one of the force-time curves doesn t follow the same behavior pattern of the rest which seems to indicate, at least by visual inspection, lack of similarity. Non-similarity of curves may indicate that the test wasn t performed according to the protocol required from the subject or even, in the case of patients, it may indicate an anomaly or pathology associated to the isometric effort. Thus, it is graphically possible to see the behavior of the mean curve due to the presence of a nonsimilar curve. The following text elucidates such procedure. 2

The mean value and the variation ratio referring to the association of mean ± standard deviation for every sign are displayed on Figure 2 where it is also observed the non-similar curve. In this picture it is possible to ascertain the distinction between this sign and the variation ratio obtained for every sign. This fact indicates the high CV value and low similarity between the sign displayed and other signs part of this conjunct. From the exclusion of the curve mentioned and taking into consideration only the other five curves inserted in the variation ratio, new time series were obtained for the mean value, standard deviation and CV whose curves are displayed in Figure 3. It can be observed that the variability of the variation ratio, for the interval between 0 and 0.4 second, is inferior to that one obtained for the variation ratio when every curve was being taken into consideration. By its own definition, the exclusion of the most discrepant values from the conjunct, contributes to the decreasing of CV values. This indicates that CV can be an identification parameter of the level of similarity between curves. The values of the coefficients of variation, for the conjunct of all six signs and only for the remaining 5 signs, are displayed in Figure 4. It can be noted the changes in the CV curves apart from the isolated sign due to the variability reduction and the variation ratio of the standard deviation. From approximately 0.4 second the CV values found don t seem to present significant differences. Coefficients of variation present different decreasing ratios in both situations. From approximately 0.1 second the coefficients of variation (taking into consideration only the remaining 5 curves) are presented in the ratio between 10% and 5% as per GILL [9.] For the rest of the subjects, the times in which the CV values have reached the ration between 5% and 10% were: 0.7s; 0.5s and 1.0s. In every one of them, the procedure was the same: the exclusion of only one of the curves out of 6 conjuncts. Mean CV values for definite intervals, considering all the signs and after the exclusion of the isolated sign, are displayed in Table 1 where the numerical results affirm the qualitative evaluations performed through the visual inspection. It is seen, though, that the percentage reduction obtained for the CV mean values in the intervals between zero and 0.3 seconds, after the exclusion of the isolated sign. For the other intervals, the proximity of the percentage affirms the concept of similarity between the force signs. Figure 1: Six force-time curves of one of the subjects obtained in the tests of isometric clench of the hand. The chart displays only the interval 0-1 second (beginning of the test.) 3

Figure 2: Mean values and its respective standard deviations for 0-1s interval considering the curve to be excluded (anomalous curve) Figure 3: Mean values and its respective standard deviations considering the exclusion of one of the curves. 4

. Figure 4: : CV values curves obtained before and after the exclusion of the isolated curve. Therefore, through a qualitative analysis performed by graphic similarity, one of the curves was excluded causing to change the mean curve shape, its respective values and standard deviations and, then, the CV values as well. It was noted that, after the exclusion of the curve, the CV values in the period from 0.1 to 0.2s decreased (as already stated, for the rest of the subjects the decreasing of CV values occurred in different periods, namely: 0.7s; 0.5s and 1.0s.) However, for all the volunteers, the rest of the CV values have remained intact up to the very end of the test (5s.) The CV mean values for each interval in the test of isometric clench (5s), are displayed on Table 1. It is also noted on Table 1 that for the rapid phase of the test (initial effort from 0 to 1.0s) the curves show more variability which does not occur from 1.0s (force maintenance phase.) Such behaviors may indicate the particularities during the performance of the test: the positioning of the hand during the test, slow variation of force at the beginning of the test, pain or even unreported/unnoticed discomfort. Table 1: CV Mean values for definitive intervals for a volunteer. Coefficient of Variation (mean values, %) time (s) CV (all curves) CV (curve excluded) 0-0,1 41,15 21,46 0,1-0,2 29,38 4,67 0,2-0,3 8,45 3,88 0,3-0,4 5,62 4,76 0,4-0,5 5,86 6,23 0,5-0,6 6,01 6,67 0,6-0,7 7,05 7,55 0,7-0,8 7,98 8,15 0,8-0,9 8,14 8,07 0,9-1,0 8,43 8,44 1,0-5,0 7,25 7,52 5

4 CONCLUSIONS Regarding the CV definition, it can be asserted that low CV indicates low standard deviation and less data dispersion. As a consequence, it can be noted a certain level of similarity or equivalence between the curves. This way, such procedures may identify the mean curve that represents best the performance of each subject during the performance of this sort of test. It can be concluded that, even for the very definition of CV, its values decreases when the curves present similar shapes and that the lowest values of CV (at the beginning of the rapid phase) occurred in specific times for each subject (0.1s; 0.7s; 0.5s and 1.0s). Even for this short period of time, with the exclusion of one of the curves, a higher similarity can be identified between the interval 0 t 0.1s, which is an interval relatively low, coherent with the rapid muscle action in this kind of test. Nevertheless, evaluating the behavior of the curve to be excluded (Figure 2), it can be stated that the first period of the test was conducted with an almost constant amount of force extremely close to zero. Obviously, in this case, the application of the concept of CV at every instant implicates in the problem related to the standard deviation: if it is kept constant and the curves approach zero, the CV values get much higher. It s seen that this increasing wouldn t be caused by the decreasing of the similarity between the curves in these instants, but for the fact that the curves almost reached zero (the subject didn t perform the test following the protocol stablished.) That being said, the use of the Coefficient of Variation would evidence the need to perform a new test. In this work, it has been made clear that CV curves are an important parameter for the identification of similarity between force-time curves in its initial phase, where the rapid muscle action is required in the tests of maximum isometric clench of the hand. Similar studies must be conducted considering the subjects who suffer from neuromuscular pathologies whose CV values might indicate specific behaviors of the muscular force in this sort of test. ACKNOWLEDGEMENT The authors acknowledge the financial support by CNPq, CAPES and FAPESP-BRASIL. REFERENCES [1] Chambers, J.M.; Cleveland, W.S.; Kleiner, B.; Tukey, P.A. Graphical methods for data analysis. Pacific Grove, California: Wadsworth & Brooks/Cole Publishing Co., 1983. [2] Cleveland, W.S. The elements of graphing data. Monterey, California: Wadsworth & Brooks/Cole Publishing Co., 1985. [3] Novo Jr., J.M.; Brenzikofer, R.; Barros, R.M.L.; Zulli, R.; Cliquet Jr., A.; Lima Filho, E. C. Modelamento do comportamento da força muscular nos testes de preensão isométrica da mão: análise por série de tempo. Anais do VII Congresso Brasileiro de Biomecânica (Proceedings of the VII Brazilian Congress on Biomechanics), Florianópolis, SC, Brasil, p.345-9, 1999. [4] Novo Jr., J.M. The muscle response to the strength test: time series data analysis. In: A multicisciplinary approach to human movement. (Org. Ana Faro), Coimbra, Faculdade de Ciências do Desporto e Educação Física, Universidade de Coimbra, p. 185-210, 2001. 6

[5] Novo Jr., J.M.; Brenzikofer, R.; Barros, R.M.L.; Lima Filho, E. C. Contribution of fingers to handgrip force-time curves. Book of abstracts, XVIIIth Congress of the International Society of Biomechanics, ETH Zurich, Switzerland, p.56-7, July 8-13, 2001a [6] Novo Jr., J.M.; Marocolo Jr., M.; Gabriel, A.U.; Lima Filho, E.C. Métodos gráficos para a análise exploratória dos dados obtidos em testes de força muscular isométrica, Anais do IX Congresso Brasileiro de Biomecânica (Proceedings of the VIII Brazilian Congress on Biomechanics), Gramado, RS, Sociedade Brasileira de Biomecânica, Brasil, p.155-160, 2001b. [7] Gabriel, A.U.; Lima Jr.; R.S.; Novo Jr., J.M. Variáveis biológicas como séries de tempo: aplicação de uma função matemática para o estudo do comportamento temporal. Revista Mineira de Educação Física, vol.10, n.1, ano X, p.335, (Proceedings of the Brazilian Forum on Physical Education and Sport Science and Minas Gerais Symposium on Sport Science), 2002. [8] Winter, D.A. The biomechanics and motor control of human gait: normal, elderly and pathological. 2 nd ed, Waterloo:University of Waterloo Press, 1991. [9] Gill, J.L. Design and analysis of experiments in the animal and medical sciences. Arnes, The Iowa State University Press, 1:1-411, 1987. [10] Amaral, J.F.; Castro, E.A.; Mancini, M.; Doimo, L.A.; Novo Júnior, J.M. Rate of force development of upper and lower limbs in elderly women. Motricidade, 8:454-461, Supl. 2, 2012. [11] Amaral, J.F.; Castro, E.A.; Doimo, L.A., Silva, M.V.; Novo Júnior, J.M. Changes in temporal development of the force in different age groups of women. Rev Bras Med Esporte [Internet]. 2015 Feb [cited 2015 May 20] ; 21( 1 ): 70-74. 7