Certification Document macle GmbH HP Proliant DL380e - Gen8 10/01/2013. macle GmbH HP Proliant DL380e - Gen8 storage system DSS

Similar documents
Certification Document macle GmbH Grafenthal-S1212M 24/02/2015. macle GmbH Grafenthal-S1212M Storage system

Certification Document macle GmbH GRAFENTHAL R2208 S2 01/04/2016. macle GmbH GRAFENTHAL R2208 S2 Storage system

Certification Document bluechip STORAGEline R54300s NAS-Server 03/06/2014. bluechip STORAGEline R54300s NAS-Server system

Test Report Newtech Supremacy II NAS 05/31/2012. Newtech Supremacy II NAS storage system

HA Certification Document Armari BrontaStor 822R 07/03/2013. Open-E High Availability Certification report for Armari BrontaStor 822R

Step-by-Step Guide. to configure Open-E DSS V7 Active-Active iscsi Failover on Intel Server Systems R2224GZ4GC4. Software Version: DSS ver. 7.

How To Compare Two Servers For A Test On A Poweredge R710 And Poweredge G5P (Poweredge) (Power Edge) (Dell) Poweredge Poweredge And Powerpowerpoweredge (Powerpower) G5I (

Figure 1A: Dell server and accessories Figure 1B: HP server and accessories Figure 1C: IBM server and accessories

TREND MICRO SOFTWARE APPLIANCE SUPPORT

White Paper Open-E NAS Enterprise and Microsoft Windows Storage Server 2003 competitive performance comparison

Fusionstor NAS Enterprise Server and Microsoft Windows Storage Server 2003 competitive performance comparison

HP recommended configuration for Microsoft Exchange Server 2010: HP LeftHand P4000 SAN

HP ProLiant Gen8 vs Gen9 Server Blades on Data Warehouse Workloads

VTrak SATA RAID Storage System

HP recommended configurations for Microsoft Exchange Server 2013 and HP ProLiant Gen8 with direct attached storage (DAS)

Proof Point: Example Clustered Microsoft SQL Configuration on the HP ProLiant DL980

Brainlab Node TM Technical Specifications

Performance characterization report for Microsoft Hyper-V R2 on HP StorageWorks P4500 SAN storage

RAID 5 rebuild performance in ProLiant

1000-Channel IP System Architecture for DSS

How To Perform A File Server On A Poweredge R730Xd With Windows Storage Spaces

Praktijkexamen met Project VRC. Virtual Reality Check

Cache, 2 GB DDR2-SDRAM, Supermicro PDSMA+ mainboard, 5 PCI

QUESTIONS & ANSWERS. ItB tender 72-09: IT Equipment. Elections Project

F600Q 8Gb FC Storage Performance Report Date: 2012/10/30

Servers, Clients. Displaying max. 60 cameras at the same time Recording max. 80 cameras Server-side VCA Desktop or rackmount form factor

NIVEO Network Attached Storage Series NNAS-D5 NNAS-R4. More information:

Frequently Asked Questions: EMC UnityVSA

Seradex White Paper. Focus on these points for optimizing the performance of a Seradex ERP SQL database:

Qsan Document - White Paper. Performance Monitor Case Studies

Terminal Server Software and Hardware Requirements. Terminal Server. Software and Hardware Requirements. Datacolor Match Pigment Datacolor Tools

DeltaV Virtualization Hardware

Deployment Guide. How to prepare your environment for an OnApp Cloud deployment.

How To Write An Article On An Hp Appsystem For Spera Hana

Out-of-box comparison between Dell and HP blade servers

Appendix 3. Specifications for e-portal

Microsoft SharePoint Server 2010

SMB Direct for SQL Server and Private Cloud

Adaptec: Snap Server NAS Performance Study

Out-of-box comparison between Dell, HP, and IBM blade servers

10.2 Requirements for ShoreTel Enterprise Systems

LaCie 12big Rack Network

10GbE Ethernet for Transfer Speeds of Over 1150MB/s

HP ProLiant Server Booklet. Virtualization Reliability Efficiency Agility

Pivot3 Reference Architecture for VMware View Version 1.03

TS500-E5. Configuration Guide

HP ProLiant DL580 Gen8 and HP LE PCIe Workload WHITE PAPER Accelerator 90TB Microsoft SQL Server Data Warehouse Fast Track Reference Architecture

MESOS CB220. Cluster-in-a-Box. Network Storage Appliance. A Simple and Smart Way to Converged Storage with QCT MESOS CB220

UCS M-Series Modular Servers

MedInformatix System Requirements

How To Back Up A Computer To A Backup On A Hard Drive On A Microsoft Macbook (Or Ipad) With A Backup From A Flash Drive To A Flash Memory (Or A Flash) On A Flash (Or Macbook) On

Selling Compellent NAS: File & Block Level in the Same System Chad Thibodeau

Hardware & Software Specification i2itracks/popiq

CONSTRUCTION / SERVICE BILLING SYSTEM SPECIFICATIONS

Windows 2008 Server Installation

StarWind iscsi SAN: Configuring Global Deduplication May 2012

Cisco MCS 7825-H3 Unified Communications Manager Appliance

Introduction to MPIO, MCS, Trunking, and LACP

Part-1: SERVER AND PC

Analysis: Determining the Impact of Switching on VSAN Performance. Do budget network

Microsoft SharePoint Server 2010

Arrow ECS sp. z o.o. Oracle Partner Academy training environment with Oracle Virtualization. Oracle Partner HUB

HP Proliant BL460c G7

TEST REPORT Dell PERC H700 average percentage win in IOPS over FEBRUARY 2006 Dell PERC 6/i across RAID 5 and RAID 10. Internal HDD tests

LSI MegaRAID CacheCade Performance Evaluation in a Web Server Environment

Enterprise Edition. Hardware Requirements

Microsoft Windows Server 2003 with Internet Information Services (IIS) 6.0 vs. Linux Competitive Web Server Performance Comparison

Cisco MCS 7816-I3 Unified Communications Manager Appliance

Visual UpTime Select Server Specifications

Post-production Video Editing Solution Guide with Microsoft SMB 3 File Serving AssuredSAN 4000

Multiple Public IPs (virtual service IPs) are supported either to cover multiple network segments or to increase network performance.

Mini server, BIG performance AC100

iscsi Performance Factors

The functionality and advantages of a high-availability file server system

Summary. Key results at a glance:

New!! - Higher performance for Windows and UNIX environments

ADVANCED NETWORK CONFIGURATION GUIDE

Fujitsu PRIMERGY BX924 S2 Dual-Socket server

EMC VMAX3 FAMILY VMAX 100K, 200K, 400K

NEWSTAR ENTERPRISE and NEWSTAR Sales System Requirements

Microsoft SQL Server 2012 on Cisco UCS with iscsi-based Storage Access in VMware ESX Virtualization Environment: Performance Study

How To Run Apa Hadoop 1.0 On Vsphere Tmt On A Hyperconverged Network On A Virtualized Cluster On A Vspplace Tmter (Vmware) Vspheon Tm (

LB-IPC. High Performance, Ultra Low Noise Low Power Consumption. Features. Applications

SERVER CLUSTERING TECHNOLOGY & CONCEPT

LSI MegaRAID FastPath Performance Evaluation in a Web Server Environment

napp-it ZFS Storage principles for Video Performance Dual Xeon, 40 GB RAM Intel X540, mtu 9000 (JumboFrames) Server OS: Oracle Solaris 11.3 SMB 2.

Dell EqualLogic Best Practices Series

Michael Kagan.

SERVER POWER CALCULATOR ANALYSIS: CISCO UCS POWER CALCULATOR AND HP POWER ADVISOR

Linux NIC and iscsi Performance over 40GbE

Configuring the HP DL380 Gen9 24-SFF CTO Server as an HP Vertica Node. HP Vertica Analytic Database

TEST REPORT OCTOBER 2009 SMB Workload performance testing: PowerEdge T110 vs. an older small business desktop running typical small

Artikel-Detailinformationen

Boosting Data Transfer with TCP Offload Engine Technology

Vendor and Hardware Platform: Fujitsu BX924 S2 Virtualization Platform: VMware ESX 4.0 Update 2 (build )

Industry First X86-based Single Board Computer JaguarBoard Released

StarWind Virtual SAN Best Practices

I/O PERFORMANCE OF THE LENOVO STORAGE N4610

HP high availability solutions for Microsoft SQL Server Fast Track Data Warehouse using SQL Server 2012 failover clustering

IT Business Management System Requirements Guide

Transcription:

macle GmbH HP Proliant DL380e - Gen8 storage system 687567-DSS 1

Executive summary After performing all tests, the macle GmbH HP Proliant DL380e - Gen8 system has been officially certified according to the Open-E Hardware Certification Program Guide 2.1. During the tests, it was found that the system is functional and efficient. With the Open-E DSS V7 operating system installed, the macle GmbH HP Proliant DL380e - Gen8 is stable and performs well. In general, the system can be used for many different applications, but the following are recommended: iscsi storage The following features make macle GmbH HP Proliant DL380e - Gen8 good iscsi storage: HW RAID5, or RAID50 for high performance and data safety. Four 1GbE and two 10GbE interfaces for fast MPIO connection and flexible network topology Redundant power supply for system reliability. NAS filer The following features make macle GmbH HP Proliant DL380e - Gen8 a good NAS filer solution: Eight high capacity SATA hard drives provide a plenty of space for user files. Hardware RAID5, RAID50 for fault tolerance and the most efficient use of available disk space. Two 10GbE and four 1GbE interfaces for independent connection to different networks or link aggregation for improved throughput. Storage for Virtualization The following features make macle GmbH HP Proliant DL380e - Gen8 great storage for a virtualization: Hardware RAID5 and RAID50 ensures failure-free work and great performance, even for demanding virtual environments. Two 10GbE and four 1GbE interfaces for efficient network connections to virtualization systems. The HP 4GB Enterprise Performance Flash keeps the OS Save Certification notes For link aggregation, it is recommended to use balance-alb bonding mode. 2

HP Proliant DL380e - Gen8 hardware components... 4 HP Proliant DL380e - Gen8 photos... 5 Auxiliary systems hardware components... 6 Administration functionality... 7 Network functionality... 8 Network test topology... 8 802.3ad bonding mode test... 9 Balance-alb bonding mode test... 10 Balance-rr bonding mode test... 12 Single NIC performance test... 14 RAID functionality... 16 RAID test topology... 16 Hardware RAID0 test... 17 Hardware RAID5 test... 18 Hardware RAID50 test... 19 NAS functionality... 20 NAS test topology... 20 SMB test... 21 iscsi functionality... 22 iscsi Initiator test topology... 22 iscsi Target test topology... 22 iscsi Initiator test... 23 iscsi Target test... 24 3

HP Proliant DL380e - Gen8 hardware components Technical specifications about the certified system are listed below: Model HP Proliant DL380e - Gen8 Operating system Open-E DSS V7 build 7637 Enclosure/chassis HP Proliant DL380e - Gen8 CPU Intel Xeon E5-2407 2.2 GHz Motherboard HP Proliant DL380e - Gen8 Memory 2x 4GB DDR3 ECC-REG Hynix PC3-1600 Network HP FlexibleLOM 1Gb 4-port 331FLR Ethernet Adapter (BCM5719) (on-board) Network Broadcom NetXtreme II HW RAID HP Smart Array P420 Hard disk drives 8x 3TB HP MB3000GBKAC (ST33000650NS) Boot media drive 4GB HP SDHC Flash Media (583039-001) TABLE 1: Hardware components list of Certified System with Open-E DSS V7 4

HP Proliant DL380e - Gen8 photos FIGURE 1: Front photo FIGURE 2: Rear photo FIGURE 3: Top photo 5

Auxiliary systems hardware components Auxiliary systems with MS Windows or Open-E DSS V7 installed, used in Open-E Hardware Certification Process. Model Operating system Enclosure/chassis Motherboard CPU Memory Network Network Hard disk drives HP ProLiant DL360e - Gen8 Server MS Windows Server 2008 R2 DL360 G5 HP Proliant DL360 G5 2x Intel X5460 QC 3.16GHz/12MB cache CPU 2x Samsung M395T5750GZ4-CE66 DDR2-667 2GB FB-DIMM NC373i embedded dual gigabit network Broadcom NetXtreme II BCM57712 10Gigabit Ethernet 146GB 10K SAS ST9146803SS TABLE 2: Hardware components of first Workstation with MS Windows Model Operating system Enclosure/chassis Motherboard CPU Memory Network Network Hard disk drives HP ProLiant DL360e - Gen8 Server MS Windows Server 2008 R2 DL360 G5 HP Proliant DL360 G5 2x Intel X5460 QC 3.16GHz/12MB cache CPU 2x Samsung M395T5750GZ4-CE66 DDR2-667 2GB FB-DIMM NC373i embedded dual gigabit network Broadcom NetXtreme II BCM57712 10Gigabit Ethernet 1x Hitachi 1TB SATA TABLE 3: Hardware components of second Workstation with MS Windows Model HP Proliant DL380e - Gen8 Operating system Open-E DSS V7 build 7637 Enclosure/chassis HP Proliant DL380e - Gen8 CPU Intel Xeon E5-2407 2.2 GHz Motherboard HP Proliant DL380e - Gen8 Memory 2x 4GB DDR3 ECC-REG Hynix PC3-1600 Network HP FlexibleLOM 1Gb 4-port 331FLR Ethernet Adapter (BCM5719) (on-board) Network Broadcom NetXtreme II HW RAID HP Smart Array P410 Hard disk drives 8x 3TB HP MB3000GBKAC (ST33000650NS) Hard disk drives 4GB HP SDHC Flash Media (583039-001) (Boot drive) Model HP Proliant DL380e Gen8 TABLE 4: Hardware components of Workstation with Open-E DSS V7 6

Model Netgear ProSafe Plus XS708E TABLE 5: Network switch details for 10GbE connections Administration functionality The following functionality has been tested. Drive identifier Power button Front and rear LEDs OK OK OK TABLE 6: Administration functionality test 7

Network functionality Tests performed in this section check the functionality, performance and stability of the network solutions available in the Open-E DSS V7 product on the certified system. The tests rely on configuring the iscsi targets and copying the data from many Workstations with MS Windows through various network connections with big block size using appropriate testing tools. Network test topology Network topology for Network testing is shown below. FIGURE 4: Network topology for Network testing 8

802.3ad bonding mode test 1. Test description The test relies on configuring the iscsi targets and copying the data from many Workstations with MS Windows through an 802.3ad bonding mode network connection with a 4MB block size using the Iometer testing tool. 2. Test for 802.3ad bonding mode test performed on HP FlexibleLOM 1Gb 4-port 331FLR Ethernet Adapter (BCM5719) (on-board) 802.3ad bonding mode performance test NIC model Workstations with MS Windows HP FlexibleLOM 1Gb 4-port Ethernet Adapter 1 st Workstation 111.05 112.21 passed 2 nd Workstation 111.55 112.14 passed 3 rd Workstation 111.52 112.13 passed 4 th Workstation 111.29 112.12 passed TABLE 7: 802.3ad bonding mode performance test table for HP FlexibleLOM 1Gb 4-port 331FLR Ethernet Adapter (BCM5719) (on-board) 1st Workstation 2nd Workstation 3rd Workstation 4th Workstation 0 20 40 60 80 100 120 FIGURE 5: 802.3ad bonding mode performance test chart for HP FlexibleLOM 1Gb 4-port 331FLR Ethernet Adapter (BCM5719) (on-board) 9

Balance-alb bonding mode test 1. Test description The test relies on configuring the iscsi targets and copying the data from many Workstations with MS Windows through a Balance-alb bonding mode network connection with a 4MB block size using the Iometer testing tool. 2. Test for Balance-alb bonding mode test performed on Broadcom NetXtreme II Balance-alb bonding mode performance test NIC model Workstations with MS Windows Broadcom NetXtreme II 10Gigabit Ethernet 1 st Workstation 524.67 136.34 passed 2 nd Workstation 529.78 200.68 passed 3 rd Workstation 523.91 133.18 passed 4 th Workstation 526.81 277.89 passed TABLE 8: Balance-alb bonding mode performance test table for Broadcom NetXtreme II 1st Workstation 2nd Workstation 3rd Workstation 4th Workstation 0 200 400 600 800 1000 1200 FIGURE 6: Balance-alb bonding mode performance test chart for Broadcom NetXtreme II 10

3. Test for Balance-alb bonding mode test performed on HP FlexibleLOM 1Gb 4-port 331FLR Ethernet Adapter (BCM5719) (on-board) Balance-alb bonding mode performance test NIC model Workstations with MS Windows HP FlexibleLOM 1Gb 4-port Ethernet Adapter 1 st Workstation 111.38 92.49 passed 2 nd Workstation 111.67 110.90 passed 3 rd Workstation 111.25 110.75 passed 4 th Workstation 111.52 110.71 passed TABLE 9: Balance-alb bonding mode performance test table for HP FlexibleLOM 1Gb 4-port 331FLR Ethernet Adapter (BCM5719) (on-board) 1st Workstation 2nd Workstation 3rd Workstation 4th Workstation 0 20 40 60 80 100 120 FIGURE 7: Balance-alb bonding mode performance test chart for HP FlexibleLOM 1Gb 4-port 331FLR Ethernet Adapter (BCM5719) (on-board) 11

Balance-rr bonding mode test 1. Test description The test relies on configuring the iscsi targets and copying the data from many Workstations with MS Windows through a Balance-rr bonding mode network connection with a 4MB block size using the Iometer testing tool. 2. Test for Balance-rr bonding mode test performed on Broadcom NetXtreme II Balance-rr bonding mode performance test NIC model Workstations with MS Windows Broadcom NetXtreme II 10Gigabit Ethernet 1 st Workstation 283.88 215.12 passed 2 nd Workstation 282.71 352.69 passed 3 rd Workstation 282.78 219.85 passed 4 th Workstation 285.93 279.40 passed TABLE 10: Balance-rr bonding mode performance test table for Broadcom NetXtreme II 1st Workstation 2nd Workstation 3rd Workstation 4th Workstation 0 200 400 600 800 1000 1200 FIGURE 8: Balance-rr bonding mode performance test chart for Broadcom NetXtreme II 12

3. Test for Balance-rr bonding mode test performed on HP FlexibleLOM 1Gb 4-port 331FLR Ethernet Adapter (BCM5719) (on-board) Balance-rr bonding mode performance test NIC model Workstations with MS Windows HP FlexibleLOM 1Gb 4-port Ethernet Adapter 1 st Workstation 90.48 80.35 passed 2 nd Workstation 77.68 64.11 passed 3 rd Workstation 64.19 73.34 passed 4 th Workstation 82.87 78.20 passed TABLE 11: Balance-rr bonding mode performance test table for HP FlexibleLOM 1Gb 4-port 331FLR Ethernet Adapter (BCM5719) (on-board) 1st Workstation 2nd Workstation 3rd Workstation 4th Workstation 0 20 40 60 80 100 120 FIGURE 9: Balance-rr bonding mode performance test chart for HP FlexibleLOM 1Gb 4-port 331FLR Ethernet Adapter (BCM5719) (on-board) 13

Single NIC performance test 1. Test description The test relies on configuring the iscsi targets and copying the data from Workstations with MS Windows through single NIC with a 4MB block size using the Iometer testing tool. 2. Test for single NIC test performed on Broadcom NetXtreme II Single NIC performance test NIC model Workstations with MS Windows Broadcom NetXtreme II 10Gigabit Ethernet 1 st Workstation 678.9 288.7 passed TABLE 12: Single NIC performance test table for Broadcom NetXtreme II 1st Workstation 0 200 400 600 800 1000 1200 FIGURE 10: Single NIC performance test chart for Broadcom NetXtreme II 14

3. Test for single NIC test performed on HP FlexibleLOM 1Gb 4-port 331FLR Ethernet Adapter (BCM5719) (on-board) Single NIC performance test NIC model Workstations with MS Windows HP FlexibleLOM 1Gb 4-port Ethernet Adapter 1 st Workstation 110.92 112.12 passed TABLE 13: Single NIC performance test table for HP FlexibleLOM 1Gb 4-port 331FLR Ethernet Adapter (BCM5719) (on-board) 1st Workstation 0 20 40 60 80 100 120 FIGURE 11: Single NIC performance test chart for HP FlexibleLOM 1Gb 4-port 331FLR Ethernet Adapter (BCM5719) (on-board) 15

RAID functionality Tests performed in this section check the functionality, performance and stability of Open-E DSS V7 storage devices on the certified system. Tests in this section rely on the creation of the RAID units on 0, 5 and 50 levels, configuring the iscsi target and copying the data from a Workstation with MS Windows via network connection with various block sizes using the Iometer testing tool. RAID test topology Network test topology for RAID testing is shown below FIGURE 12: Network test topology for RAID testing 16

Block size [KB] Certification Document macle GmbH HP Proliant DL380e - Gen8 10/01/2013 Hardware RAID0 test 1. Test description The test relies on creation of the RAID0 unit on all hard disk drives, configuring the iscsi target and copying the data from a Workstation with MS Windows via network connection with various block sizes using the Iometer testing tool. 2. Test for RAID0 and Broadcom NetXtreme II 10Gigabit Ethernet (BCM57712) RAID0 performance test Block size [KB] 4 13.28 51.94 passed 32 96.00 222.43 passed 64 203.66 277.44 passed 128 340.17 354.53 passed 256 490.39 440.54 passed 512 529.59 460.23 passed 1024 555.51 468.46 passed 4096 552.93 482.93 passed TABLE 14: RAID0 performance test table for Broadcom NetXtreme II 4 32 64 128 256 512 1024 4096 0 200 400 600 800 1000 1200 FIGURE 13: RAID0 performance test chart for Broadcom NetXtreme II 17

Block size [KB] Certification Document macle GmbH HP Proliant DL380e - Gen8 10/01/2013 Hardware RAID5 test 1. Test description The test relies on creation of the RAID5 unit on all hard disk drives. configuring the iscsi target and copying the data from a Workstation with MS Windows via network connection with various block sizes using the Iometer testing tool. 2. Test for RAID5 and Broadcom NetXtreme II 10Gigabit Ethernet (BCM57712) RAID5 performance test Block size [KB] 4 14.72 49.78 passed 32 99.34 229.72 passed 64 208.73 298.26 passed 128 342.32 355.69 passed 256 490.46 447.34 passed 512 524.85 472.69 passed 1024 552.20 479.76 passed 4096 554.71 500.92 passed TABLE 15: RAID5 performance test table for Broadcom NetXtreme II 4 32 64 128 256 512 1024 4096 0 200 400 600 800 1000 1200 FIGURE 14: RAID5 performance test chart for Broadcom NetXtreme II 18

Block size [KB] Certification Document macle GmbH HP Proliant DL380e - Gen8 10/01/2013 Hardware RAID50 test 1. Test description The test relies on creation of the RAID50 unit on all hard disk drives. configuring the iscsi target and copying the data from a Workstation with MS Windows via network connection with various block sizes using the Iometer testing tool. 2. Test for RAID50 and Broadcom NetXtreme II 10Gigabit Ethernet (BCM57712) RAID50 performance test Block size [KB] 4 17.11 46.75 passed 32 104.28 226.56 passed 64 204.25 303.83 passed 128 300.30 359.40 passed 256 435.94 462.47 passed 512 485.06 482.42 passed 1024 499.75 493.92 passed 4096 506.42 508.51 passed TABLE 16: RAID50 performance test table for Broadcom NetXtreme II 4 32 64 128 256 512 1024 4096 0 200 400 600 800 1000 1200 FIGURE 15: RAID50 performance test chart for Broadcom NetXtreme II 19

NAS functionality Tests performed in this section check the functionality. performance and stability of the NAS protocols in the Open-E DSS V7 product on the certified system. The tests rely on creating NAS shares and copying the data from a Workstation with MS Windows via network connection with various block sizes using the Iometer testing tool. NAS test topology Network topology for NAS testing is shown below. FIGURE 16: Network topology for NAS testing 20

Block size [KB] Certification Document macle GmbH HP Proliant DL380e - Gen8 10/01/2013 SMB test 1. Test description The tests rely on creating NAS shares and copying the data from a Workstation with MS Windows via network connection with various block sizes using the Iometer testing tool. 2. Test for SMB Broadcom NetXtreme II 10Gigabit Ethernet (BCM57712) SMB performance test Block size [KB] 4 71.24 54.86 passed 32 423.95 271.45 passed 64 777.08 251.00 passed 128 873.41 336.94 passed 256 873.89 396.07 passed 512 858.08 423.86 passed 1024 847.66 428.39 passed 4096 861.41 461.06 passed TABLE 17: SMB performance test table for Broadcom NetXtreme II 4 32 64 128 256 512 1024 4096 0 200 400 600 800 1000 1200 FIGURE 17: SMB performance test chart for Broadcom NetXtreme II 21

iscsi functionality Tests performed in this section check the functionality. performance and stability of the iscsi protocol in the Open-E DSS V7 product on the certified system. iscsi Initiator test topology Network topology for iscsi Initiator testing is shown below. FIGURE 18: Network topology for iscsi Initiator testing iscsi Target test topology Network topology for iscsi Target testing is shown below. FIGURE 19: Network topology for iscsi Target testing 22

Block size [KB] Certification Document macle GmbH HP Proliant DL380e - Gen8 10/01/2013 iscsi Initiator test 1. Test description The test relies on using the storage connected via the built-in iscsi Initiator for NAS volumes. creating SMB shares on these NAS volumes and copying data from a Workstation with MS Windows to them with various block sizes using the Iometer testing tool. 2. Test for iscsi Initiator Broadcom NetXtreme II 10Gigabit Ethernet (BCM57712) iscsi Initiator performance test Block size [KB] 4 52.58 67.74 passed 32 260.32 239.25 passed 64 461.33 342.16 passed 128 632.26 406.65 passed 256 812.87 256.55 passed 512 897.03 275.21 passed 1024 912.30 373.95 passed 4096 1017.53 389.78 passed TABLE 18: iscsi Initiator performance test table for Broadcom NetXtreme II 4 32 64 128 256 512 1024 4096 0 200 400 600 800 1000 1200 FIGURE 20: iscsi Initiator performance test chart for Broadcom NetXtreme II 23

Block size [KB] Certification Document macle GmbH HP Proliant DL380e - Gen8 10/01/2013 iscsi Target test 1. Test description The test relies on creating the iscsi target on the certified system and copying the data from a Workstation with MS Windows to it with various block sizes using the Iometer tool. 2. Test for iscsi Target Broadcom NetXtreme II 10Gigabit Ethernet (BCM57712) iscsi Target performance test Block size [KB] 4 13.48 48.74 passed 32 96.32 221.86 passed 64 204.05 285.71 passed 128 336.43 361.80 passed 256 484.87 442.87 passed 512 510.65 487.38 passed 1024 526.80 488.52 passed 4096 539.71 503.21 passed TABLE 19: iscsi Target performance test table for Broadcom NetXtreme II 4 32 64 128 256 512 1024 4096 0 200 400 600 800 1000 1200 FIGURE 21: iscsi Target performance test chart for Broadcom NetXtreme II 24