EEx ed/emd pendant control stations

Similar documents
Terminal Box. Specifications TNCN

Pendant control stations 6

Explosion proof enclosures

Pendant control stations 6

9 Control Equipment. Control Button Series 8082

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Instructions for Safe Use

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

I E D C E R T. Net MA N A G E ME N T S Y S T E M ISO 9001: RAVI. Pendant Stations LADY Series

Operating Instructions

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Guide to enclosures for potentially explosive atmospheres

Technical Data. Dimensions

distributing & controlling system solutions

Hazardous Locations Training

Equipment vs. Component

Making sense of Intrinsic Safety and Intrinsically Safe Tools

Hazardous location. Definitions

Terminal Boxes Series 8146

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Compact pressure switch Flameproof enclosure Ex d Model PCA

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

INTERNATIONAL STANDARD

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

Operating Instructions

EDS / EFS Series Control Stations

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

CONSULTING Training Courses

Safety instructions VEGADIS DIS81.CEIA/V****

EDS / EFS Series Control Stations

IECEX CERTIFICATION SCHEMES VERSUS ATEX DIRECTIVES

Acclaim III Recessed Fluorescent Luminaires ATEX

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Manual. Simrad StructureScan LSS-1 Sonar Module. English

Plug and Socket Devices SolConeX 16 A Series 8570

Control and Signaling Units

A good connection. International approvals.

Technical Data. Dimensions

Solenoid Valve Island Type 3965

Plug and Socket Devices CES 63 A Series 8579

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

2CMC300001D0003 November Enclosed switches ATEX

Operating Instructions

Control Stations Made of Polyester Resin Series 8146

Floodlight Range Installation Guide

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Control and Distribution Boxes made of Stainless Steel Series 8150

StructureScan HD Module. Installation Guide ENGLISH

Wolflite Safety Handlamp H-251E

ATEX Fans 08/02/2008. Data subject to change without prior notice

Inductive slot sensor

Fire Alarm System Accessories

7 Lighting Technology

IMPORTANT SAFETY NOTICE

Technical data sheet TDS0070

5/3/2010. Article 500 address the requirements for hazardous locations: Wiring Equipment

Products Solutions Services. CompEx training From the process safety experts

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

SEISMIC VELOCITY TRANSDUCER T1-40

FGM 160 ATEX EC type examination certificate

Safety Storage Cabinets

CUSTOMS UNION. CUSTOMS UNION CERTIFICATE OF CONFORMANCE No. RU C-DE.ГБ05.В Series RU No

Electro-pneumatic control valves

Linear Luminaire with LED Series EXLUX 6402/2

Manual. Solar Fountain Mobile Phone Charger

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

INFRARED QUARTZ WALL HEATER

Electrical Equipment in Hazardous Areas: Field Inspections

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

WB/WBS 3, 4, 5, 7, 8, 11, 14, 30

Inductive sensor NI10-M18-Y1X-H1141

2 & 5-Wire Overfill Sensors

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions

Understanding European versus U.S. temperature code ratings for solenoidoperated. A White Paper From ASCO

Decree of the Ministry of the Environment on fire safety of ventilation systems

STORE HAZARDOUS SUBSTANCES SAFELY. incompatibles gas cylinders

Fire & Explosion Risks in Service Stations

Mureva Assembly surface mounted wiring devices

An Introduction to ATEX -

General 1-2-Opto-electronics Safety Switches 4-Emergency

Safety dialogue solutions

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

Accessories SUNNY REMOTE CONTROL

DC400 Dispensing Cutoff System

Charging what can be more simple? SAE J1772

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

Flameproof Audible Signal 115 db (A) Series YA90

Scraper Passage Indicator. Electrical Indicator. Features

TEIP11-PS I/P signal converter for standard signals. Measurement made easy

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Series 8146/5-V37 and Series 8150/5-V37

Single sub-base valve

Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction

Professional Series ATEX Portable Radios

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

Transcription:

XAW-P Features The XAW-P range of Pendant control stations consists of several sizes from 2 to 16 ways. Booted operators (interchangeable) From 1 to 3 contacts per way Pilot light (with LED multivoltage, multicurrent) Emergency mushroom head Ø40 Standard and flexible composition ne or two step(s) action per way P 65 as standard Cable boot suitable for Ø10 to Ø22 mm cable Standard and flexible arrangement ATEX approved for Gas and Dust applications (Zones 1, 2, 21 and 22) Technor Atex, BP 708, ZA Les Montagnes, FR-16430 Champniers, France Tel: +33 5 45 93 01 10, Fax: +33 5 45 93 01 15, E-mail: technor@technoratex.fr www.technor.com

Applications The XAW-P range of pendant control stations is suitable for all kind of industry where an explosive atmosphere may be present. This range is certified ATEX 2 GD General specifications Material Metal, Rubber and GRP P Rating P65 according to EC 60529 Temperature -20 C to +60 C (without lighting functions) -20 C to +50 C (with lighting functions) Approvals ATEX - NERS 03ATEX0122 Standards Cenelec EN50014, EN50018, EN50019, EN50028,EN500281-1-1 Ex-Code 2 GD - EEx ed C / EEx emd C Mounting Assembly of components only by Technor Connection Screw clamp terminals From 1 x 0,5 mm² cable to 2 x 1,5 mm² cable (with or without ferrule) Cable entry capacity for Ø10 to Ø22 mm cable XAWP8... Use of each unit must be solely limited to its intended purpose These devices must be installed, used and maintained in accordance with: - Standard EN 60 079-14 (electrical installations and gaseous explosive atmosphere) - Standard EN 60 079-17 (inspection and maintenance in hazardous areas) - Standard EN 50 281-1-2 (electrical apparatus for use in the presence of combustible dust. Part 1-2: electrical apparatus protected by enclosures Selection, installation and maintenance). - Decrees, orders, laws, directives, circulars of applications, standards, regulations and any other document about their installation s place. We cannot accept any responsibility for failure to observe these regulations mportant: Approved and qualified staff must carry out device installation, assembling, connection, operation, maintenance and repairing. The function of these products must be respected. «Liability for manufacturer traceability is ensured at the first known delivery destination.» XAWP4... ZA2BS54 + ZBWE102

XAW-P EEx ed/emd pendant control stations Stations Fitted with interchangeable booted operators and cable boot suitable for Ø10 to Ø22mm Number of way Function Contact blocks mounted on each way Reference Weight Kg XAWP271 0,940 2 + XAWP281 1,000 XAWP471 1,290 4 + XAWP481 1,400 XAWP671 1,650 6 + XAWP681 1,800 Fitted with interchangeable booted, operators with start and emergency stop functions. With labels in yellow blank and cable boot suitable for Ø10 to Ø22mm cable Number of way Function Contact blocks mounted on each way Reference Weight Kg 4 For Direction and Start + For All For Stop Function XAWP472 XAWP482 1,320 1,380 6 For Direction and Start For Stop Function XAWP672 1,650 + For All XAWP682 1,690 8 For Direction and Start For Stop Function XAWP872 2,000 + For All XAWP882 2,250

Double step stations Fitted with double step mechanism on each. Legend plate 30x40mm black or white symbols on white or black background. Cable boot suitable for Ø10 to Ø22mm Number of way Function Contact blocks Reference Weight Kg 2 XAWP2271 1,000 4 XAWP4271 1,400 6 XAWP6271 1,800 Double step stations Fitted with double step mechanism on each indicator. lluminated or not start label, red Ø40 Mushroom head latching to release, yellow blank label, cable boot suitable for Ø10 to Ø22mm Number of way Function Contact blocks Reference Weight Kg 4 3 1 For Start 4 2 For Stop XAWP4272 with standard START XAWP4373 with illuminated START 1,350 6 3 1 For Start 4 2 For Stop XAWP6272 with standard START XAWP6373 with illuminated START 1,800 8 3 1 For Start 4 2 For Stop XAWP8272 with standard START XAWP8373 with illuminated START 2,250

XAW-P EEx ed/emd pendant control stations Design your own pendant control station. XAWP... XAWP...D

Accessories and spare parts Type Function Reference Empty pendant control station for mounting exclusively by TECHNR Slow break contact block Complete booted operator Selector switches (Stayput) 02 buttons XAWP029 04 buttons XAWP049 06 buttons XAWP069 08 buttons XAWP089 12 buttons XAWP069D 16 buttons XAWP089D N/ ZBWE101 N/C ZBWE102 White (W) XAWP9411 Black (B) XAWP9412 Green (G) XAWP9413 Red (R) XAWP9414 2 pos. Black XBW5AD21 3 pos. Black XBW5AD33 lluminator Start Green (G) XLW5AW3331 White XLW5AV013 Green XLW5AV033 Pilot light + head (-24V to 415V AC-DC) Red XLW5AV043 Yellow XLW5AV053 Blue XLW5AV063 Blank plug XAWZ3 Double step push-buttons White (W) XAWP9421 (use only with ZBWE101 contact blocks) Black (B) XAWP9422 Emergency Mushroom head (Ø40) ZA2BS54 + ZBWE102 Emergency Mushroom head (Ø30) ZA2BS44 + ZBWE102 ZBWE101 XAWP9411 ARRW for Double step ARRW for Single step UP ZBWY4953 UP ZBWY4951 DWN ZBWY2956 DWN ZBWY2954 RGHT ZBWY4903 RGHT ZBWY4901 LEFT ZBWY2906 LEFT ZBWY2904 FRWARD ZBWY4965 FRWARD ZBWY4963 REVERSE ZBWY2968 REVERSE ZBWY2966 XLW5AV033 FAST UP FAST DWN FAST RGHT FAST LEFT FAST FRWARD FAST REVERSE - - - - EMERGENCY STP ZBWY4952 ZBWY2955 ZBWY4902 ZBWY2905 ZBWY4964 ZBWY2967 ZBWY4980 ZBWY2931 ZBWY2178 ZBWY2179 ZBWY2186 ZBWY2330

XAW-P EEx ed/emd pendant control stations

Hazardous area information & terminology ATEX Directive The ATEX Directive, derived from the French ATmosphères EXplosibles and formally known as 94/9/EC, contains the ESR (Essential Safety Requirements) to which electrical equipment and protective systems used within potentially explosive atmospheres must conform. The new ATEX Directive currently in place within the European Union was made mandatory on 1st July 2003. Primarily intended for manufacturers of hazardous area equipment for use in the presence of flammable gases, vapours, fumes or dusts, the new directive requires a quality management system to be implemented. Procedures for design, manufacture and verification of products are to be approved by a notified body (i.e. NERS, etc ) and all equipment conforming to the new directive will feature CE and epsiolon Ex. Zone Classification with the presence of DUST Zone 21 Zone 22 An area in which an explosive atmosphere in the form of a cloud of combustible dust in air is likely to occur in normal operation of the plant. A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is not likely to occur in normal operation, if it does occur, will persist for a short period only. Applicable EX protection EEx e Protection for electrical components that do not spark under normal working conditions but where measures are applied to prevent high temperatures and the occurence of arcs and sparks internally. EEx d Protection Parts, which can ignite a potentially explosive atmosphere, are surrounded by an enclosure, which are designed to withstand the pressure of an internal explosion and to prevent the propagation of the explosion to the atmosphere surrounding the enclosure. EEx m Protection Parts that could ignite a potentially explosive atmosphere by means of heat or sparks are embedded in a sealing compound such that the potentially explosive atmosphere cannot be ignited. The compound is resistant to physical, electrical, thermal and chemical influences. Zone Classification with the presence of GAS Zone 1 (Category 2) Zone 2 (Category 3) An area in which explosive gas is likely to be present during normal operation of the plant. An area in which explosive gas is not continuously present, but may exist for a short period of time. XAW126-E13-01 FEBRUARY 2007 VERSN 1.0 ARTDRECTR.N SPESALTRYKK