HEAT PUMP SIZING. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

Similar documents

Glossary of Heating, Ventilation and Air Conditioning Terms

Hybrid (Dual Fuel) - Gas Heat and Air Source Heat Pump

GEOTHERMAL HEATING AND COOLING INTRODUCTION

Below are detailed instructions for using the EMS load calculator.

The formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

Models: Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel. Blower Housing

RESEARCH HIGHLIGHT. Performance Assessment of a Cold-Climate Air Source Heat Pump

HVAC Efficiency Definitions

Thermostatic Wiring Principles by Bob Scaringe Ph.D., P.E.

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL WH483 WH602. Contents. General Notes. Important. Description

Air-Conditioning Buying Guide

WON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin / March 2013

Models: WA182, WA242. Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel.

Energy Efficiency. Energy Efficient Home Cooling:

Air Conditioning Contractors of America

TECHNICAL MANUAL GDS8 & GHS8

Geothermal Comfort Systems

QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM

UNDERSTANDING AND USING THE HVAC DESIGN REVIEW FORM

ARMSTRONG AIR HEAT PUMPS

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

Understanding Heating Seasonal Performance Factors for Heat Pumps

HEAVY DUTY STORAGE GAS

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Solar Heating Basics Page 1. a lot on the shape, colour, and texture of the surrounding

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Comparing Fuel Costs of Heating and Cooling Systems

Residential Air Conditioning. Program Standards

How To Make A High Efficiency Thermostat

INSTALLATION INSTRUCTIONS MC95HAE-1 MASTER CONTROLLER

Heating & Cooling Efficiency

Air Conditioning Sign-Off Sheet

Tech Byte 27: Small Computer Room and IT Closet Cooling

Makeup Air For Exhaust Systems In Tight Houses. Tony Jellen Engineering Projects

HVACPowDen.xls An Easy-to-Use Tool for Recognizing Energy Efficient Buildings and HVAC Systems

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

E2 Series Electric Furnaces

Residential HVAC Load Sizing Training October 14, David Kaiser Green Code Plan Reviewer

Strategy Guideline: HVAC Equipment Sizing

Certified Residential Energy Auditor (REA) Study Guide

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

Your Guide to Buying an Energy-Efficient Central Air Conditioner

Ductless Heat Pumps. Gary Nordeen January

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INSTALLATION INSTRUCTIONS HOT GAS BYPASS SYSTEM DESIGN MANUAL

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Data Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT?

Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes

Commercial Energy Savings Guide.

Heat Pumps for Swimming Pools

Sustainable Design and Energy-Efficient Building Techniques for Existing Housing

THE PSYCHROMETRIC CHART AND ITS USE

GCS16 GCS20 WARNING CAUTION

PACKAGE AIR CONDITIONERS REPLACEMENT PARTS MANUAL

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

A Glossary of HVAC Terms:

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL W70A1 W70L1. Models: Contents. General Notes. Important. Description

5 Factors For Finding Your HVAC Comfort Zone

Buying a new air conditioning system is a big decision. Bahr s has

Glossary of HVAC Terms

Cased/Uncased Coils For Gas And Oil Furnaces

Laundry Hot Water Systems

Creating Efficient HVAC Systems

WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

OIL FURNACES CLASSIC PREMIUM CLASS UPFLOW OIL FURNACES. ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA

Commercial Gas Furnace Upflow

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

WaterFurnace Explains GEOTHERMAL HEATING & COOLING

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

HSX19 Air Conditioner Up to SEER. Home Comfort Systems HSX19. The most quiet and efficient central air conditioner you can buy.

Low Profile Unit Cooler

Split System Cooling Product Data

The Toledo Edison Company Toledo, Ohio Page 1 of 1. P.U.C.O. No. 8 SCHEDULE OF RATES FOR ELECTRICITY SUPPLY

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

TWE+TTA TWE+TWA T.R.

Project Aug 2011 ADRIAN. Prepared by Victor Carroll

How To Calculate Total Cooling Requirements For Data Center

5.6 Technical Specification: Premium Efficiency Electric Air Conditioning Equipment

SECTION HEAT PUMPS

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%

Ground Source Heat Pumps The Fundamentals. Southington, Connecticut John F. Sima III P.E.

The efficient heat pump

Chilled Water HVAC Systems

AircoSaver Energy Savings for At&t Mobility San Diego

Residential HVAC System Sizing

Saving Heating Costs In Warehouses

RESEARCH HIGHLIGHT. The Impact of Heat Pump Water Heaters on Whole-House Energy Consumption

How To Save Energy On A Power Supply

Calculating Total Cooling Requirements for Data Centers

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler

Energy Efficiency. Energy Efficient Water Heating: Purchasing a new electric water heater. Hot water use has a significant impact on your bill.

Transcription:

HEAT PUMP SIZING Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914... Moving ahead, just as planned. Manual No.: 2100-057 Rev. A Superseds: 2100-057 File: Volume I, Tab 1 Date: 08/30/95

CONTENTS Structure Heat Loss and Balance Points... 1 Air to Air Heat Pumps... 1 Water to Air Heat Pumps... 2 i

STRUCTURE HEAT LOSS AND BALANCE POINTS AIR TO AIR HEAT PUMPS To utilize the system performance curves or equipment specification sheets published by Bard Manufacturing Company as a tool in determining how many outdoor thermostats to use and at what temperature to set each individual thermostat, there is certain information that must be previously determined: 1. Using ACCA Manual J, calculate both the cooling and heating capacities required for the structure based upon the areas summer and winter design conditions. 2. Having determined the cooling and heating capacities required, make the unit selection primarily based on cooling capacity. It has become a generally accepted practice to use the next larger size unit if the cooling calculation falls between unit rating sizes (recommended that the unit selected is not greater than 25% larger than is calculated). Remember, the heat pump units are generally referred to in nominal tonnage sizes (2-1/2 ton, 3 ton, etc.), and the actual rated Btuh may be slightly greater or less than nominal tonnage ratings. Be sure to take into consideration that the unit capacity varies with outdoor temperature. Referring to the application chart on the specification sheets, the unit can be selected from the temperature column nearest the cooling design temperature. 3. Having made the unit selection, the heating capacity at various outdoor temperatures can be determined from the application charts or the performance curves. From this information you can determine how much of the total heat required can be supplied by the heat pump. Any heating capacity over and above that available from the heat pump system must come from an alternate source, in most cases supplemental resistance electric heating elements installed either in the indoor blower coil cabinet or in the form of a duct hater. In most areas of the country the supplemental resistance heat is sized as near as possible to 100%. There are some geographic regions where it has been acceptable to size the supplemental heat at approximately 85% with no problems encountered. 4. Determination of the total installed KW of the supplemental electric heaters is made by taking the heating load calculation (@ the outdoor winter design condition) and dividing that value by 3,413. Example: 78,000 Btuh winter design = 22.85KW 3,413 Heaters are rated nominally 25KW @ 240V 23KW @ 230V Would probably elect to use nominal 25KW heater. 5. The electric heaters used in most Bard units are nominal 5KW increments (4.6KW @ 230V). A unit built with 10KW heater is actually two 5KW heaters, nominally mounted on the same end plate. Whenever there is a 10KW heater installed, it is controlled by one two-pole contactor. In essence we are then switching a 10KW load. If this is unacceptable, an outdoor thermostat can be used to hold off one of the 5KW heaters based on outdoor temperature. 6. Having determined the above items 1-5, we can now select the appropriate performance curve matching the unit selected for installation. Example: Model 30HPQ3/B36EHQ 25KW This selection made based upon cooling design calculation of 30,000 Btuh @ 90º F. Total installed electric heat see item 4 example. 7. Using the correct performance curve, or develop your own performance curve for particular unit by using a specification sheet, locate the outdoor design temperatures (heating) and unit rated Btuh on a (B008) graph. After you have located the points, connect them for the performance curve line for the unit selected) plot the heating design point, in this example 78,000 Btuh @ 0º F. See Figure 1. Draw a straight line between this point and 70º F and 0 Btuh. The 70º F value is used because it is generally assumed that if it is 70º F outside temperature, there is enough self-heating in a typical structure that no additional heat is required. (Some people prefer to use 65º F rather than 70º F for this self-sufficiency point.) Page 1

NOTE: Not all the performance curves are drawn with 0 Btuh in the left hand column coinciding with the outdoor temperature value line across the bottom of the graph. The 0 Btuh point will have to be marked on the graph on the 70º F (or 65º F) vertical line. Each heavy horizontal line represents 10,000 Btuh. This line drawn between the heating design condition and 0 Btuh at 70º F outside temperature is called the structure heat loss line. 8. At whatever point the heating capacity curve intersects the structure heat loss line is called the balance point. The heat pump balance point is the outdoor temperature at which the heat pump would be operating 100% of the time and supplying just enough heat to match the heat loss from the structure. At outdoor temperatures above the #1, or heat pump balance point, the heat pump would cycle on demand from the wall thermostat. At outdoor temperatures below the #1 balance point, the heat pump would be operating 100% of the time because it could not supply as much heat as would be lost through the structure walls, ceiling, etc. 9. At this point, the second stage of the wall thermostat would take over and cycle on the first bank of supplemental heat (as mentioned earlier, normally in 10KW banks). There is a nominal 1-1/2º F differential between first and second stage of the two-stage wall thermostat. The 10KW heater will supply roughly 34,130 Btuh (one watt = 3.413 btu). Draw a line vertically from the #1 balance point to a point 34,000 Btu above the #1 balance point, and then draw a new heating capacity line, until this new line intersects the structure heat loss line. This would be the #2 balance point, and the outdoor temperature at which we must now bring in additional supplemental heat by means of an outdoor thermostat. It is suggested that the outdoor thermostat be set a few degrees above the calculated balance point to allow for small discrepancies which are sure to exist. 10. Depending upon the amount of installed electric heat and the manner in which you desire to stage that heat, any number of balance points can be determined. If different KW increments of electric heat are involved, simply work accordingly by figuring 3.413 Btu/watt. WATER TO AIR HEAT PUMPS To utilize the specification sheet published by Bard Manufacturing Company as a tool to determine unit size for a particular structure, there is certain information that must be previously determined: 1. Using ACCA Manual J, calculate both the cooling and heating capacities required for the structure based upon the areas summer and winter design conditions. 2. Having determined the cooling and heating capacities required, make the unit selection primarily based on cooling load plus 25% or 75 to 85% of heating load design loss, whichever is larger. Ground loop systems usually sized for cooling and well systems sized for cooling or heating. If unit is too oversized for cooling, it will not air condition properly in summer. Oversized equipment does not operate at optimum efficiency and has a high first cost. Be sure to take into consideration that the unit capacity varies with supply water temperatures. 3. Having made the unit selection, the heating or cooling capacities at various ground temperatures can be determined from specifications. From this information you can determine how much of the total heat required can be supplied by the heat pump. Any heating capacity over and above that available from the heat pump system must come from an alternate source, in most cases supplemental resistance electric heating elements installed either in the indoor blower coil cabinet or in the form of a duct heater. On a retrofit installation the existing fossil fuel furnace may be used for supplemental heat. In most areas of the country the supplemental resistance heat is sized as near as possible to 100%. There are some geographic regions where it has been acceptable to size the supplemental heat at approximately 85% with no problems encountered. 4. Determination of the total installed KW of the supplemental electric heaters is made by taking the heating load calculation (@ the outdoor winter design condition) and dividing that value by 3,413). Example: 40,460 Btuh winter design = 11.85KW 3,413 Heaters are rated nominally 15KW @ 240V 4.6KW @ 230V Would probably elect to use nominal 15KW heater. 5. The electric heaters used in most Bard units are nominal 5KW increments (4.6KW @ 230V). A unit built with 10KW heater is actually two 5KW heaters, normally mounted on the same end plate. Page 2

Whenever there is a 10KW heater installed, it is controlled by one two-pole contactor. In essence we are then switching a 10KW load. If this is unacceptable, an outdoor thermostat can be used to hold off one of the 5KW heaters based on outdoor temperature. 6. Having determined the above items 1-5, we can now select the appropriate unit performance for installation. Example: Model WPV30 This selection made based upon a heating design calculation of 40,460 Btuh @ 0º F. Cooling design calculation of 20,203 Btuh @ 90º F. Using a (B008) graph, plot the heating design point, in this example: 40,460 Btuh @ 0º F. See Figure 2. Draw a straight line between this point and 70º F and 0 Btuh. The 70º F value is used because it is generally assumed that if it is 70ºF outside temperature, there is enough self-heating in a typical structure that no additional heat is required. (Some people prefer to use 65º F rather than 70º F for this self-sufficiency point.) This line drawn between the heating design condition and 0 Btuh at 70º F outside temperature is called the structure heat loss line. 7. Draw a horizontal line across the graph at the Btuh heating capacity of the heat pump at the rated supply water temperature and flow rate. Example: Our unit will supply 28,630 Btuh at a water temperature of 55º F and a flow rate of 4 gallons per minute. 8. At whatever point the heating capacity line intersects, the structure heat loss line is called the balance point. The heat pump balance point is the outdoor temperature at which the heat pump would operate TABLE 1 ELECTRIC HEATER TABLE (KW VS. VOLTAGE) 100% of the time and supply just enough heat to match the heat loss of the structure. At outdoor temperatures above the #1, or heat pump balance point, the heat pump would cycle on demand from the wall thermostat. At outdoor temperatures below the #1 balance point, the heat pump would be operating 100% of the time because it could not supply as much heat as would be lost through the structure walls, ceiling, etc. 9. At this point, the second stage of the wall thermostat would take over and cycle on the first bank of supplemental heat (as mentioned earlier, normally in 10KW banks). There is a nominal 1-1/2º F differential between first and second stage of two-stage wall thermostat. The 5KW heater will supply roughly 17,065 Btuh (one watt = 3.413 Btu). Draw a line vertically from the #1 balance point to a point 17,000 Btu above the #1 balance point, and then draw a new heating capacity line from that point, parallel with the heat pump capacity line, until this new line intersects the structure heat loss line. This would be the #2 balance point. 10. Depending upon the amount of installed electric heat and the manner in which you desire to stage that heat, any number of balance points can be determined. If different KW increments of electric heat are involved, simply work accordingly by figuring 3.413 Btu/watt. Heater 240V 230V 220V 208V Model KW BTUH AMP KW BTUH AMP KW BTUH AMP KW BTUH AMP 4KW 4.0 13,652 16.7 3.68 12,560 16.0 3.36 11,468 15.3 3.0 10,239 14.4 5KW 5.0 17,065 20.8 4.6 15,700 20.0 4.2 14,335 19.1 3.75 12,799 18.0 8KW 8.0 27,304 33.3 7.36 25,120 32.0 6.72 22,935 30.5 6.0 20,478 28.8 10KW 10.0 34,130 41.6 9.2 31,400 40.0 8.4 28,669 38.2 7.5 25,598 36.1 12KW 12.0 40,956 50.0 11.04 37,680 48.0 10.08 34,403 45.8 9.0 30,717 43.3 15KW 15.0 51,195 62.5 13.8 47,099 60.0 12.6 43,004 57.3 11.25 38,396 54.1 20KW 20.0 68,260 83.3 18.4 62,799 80.0 16.8 57,338 76.4 15.0 51,195 72.1 25KW 25.0 85,325 104.2 23.0 78,499 100.0 21.0 71,673 95.5 18.75 63,944 90.1 30KW 30.0 102,390 125.0 27.6 94,199 120.0 25.2 86,008 114.5 22.5 76,793 108.2 9KW-3PH 9.0 30,717 21.7 8.28 28,260 20.8 7.56 25,802 19.8 6.75 23,038 18.7 12KW-3PH 12.0 40,956 28.9 11.04 37,680 27.7 10.08 34,403 26.5 9.0 30,717 25.0 15KW-3PH 15.0 51,195 36.1 13.8 47,099 34.6 12.6 43,004 33.1 11.25 38,396 31.2 18KW-3PH 18.0 61,434 43.4 16.56 56,519 41.6 15.12 51,605 39.7 13.5 46,076 37.5 24KW-3PH 24.0 81,912 57.8 22.08 75,359 55.4 20.16 68,806 52.9 18.0 61,434 50.0 30KW-3PH 30.0 102,390 72.2 27.6 94,199 69.3 25.2 86,008 66.1 22.5 76,793 62.4 All heaters are rated at 240V nominal. Note: The KW, Btuh and Amp change with the applied voltage. Page 3

FIGURE 1 AIR TO AIR HEAT PUMP (GRAPH B008) 120 110 Heat Loss of Building or Heating System Output (Thousands of Btuh) 100 90 80 70 60 50 40 30 20 10 Heating Design Point 10KW Additional Line Capacity Curve Line Outdoor Thermostat Balance Point #2 10KW Line Second Stage Balance Point #1 Structure Heat Loss Line 0-20º -10º 0º 10º 20º 30º 40º 50º 60º 65º 70º Outdoor Temperature ºF Page 4

FIGURE 2 WATER TO AIR HEAT PUMP (GRAPH B008) 120 110 Heat Loss of Building or Heating System Output (Thousands of Btuh) 100 90 80 70 60 50 40 Heating Design Point 30 20 10 Balance Point #2 Balance Point #1 5KW Line Second Stage Unit Capacity Line Structure Heat Loss Line 0-20º -10º 0º 10º 20º 30º 40º 50º 60º 65º 70º Outdoor Temperature ºF Page 5

FIGURE 3 GRAPH B008 120 Heat Loss of Building or Heating System Output (Thousands of Btuh) 110 100 90 80 70 60 50 40 30 20 10 0-20º -10º 0º 10º 20º 30º 40º 50º 60º 65º 70º Outdoor Temperature ºF Page 6