Sample Probe Module. User s Manual. A Swagelok Pre-Engineered. Subsystem. Pre-engineered subsystems available in weeks, not months.

Similar documents
Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Stainless Steel Single and Dual Circulation Kits

Multipurpose Ball Valves

Float and Thermostatic Traps Series H, C and X

Submersion/Insertion Toroidal Sensor

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Toroidal Conductivity Sensor

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Your safety and the safety of others are very important.

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

PTU Series Ultrahigh-Purity Pressure Transducers

USER MANUAL. 10 GPM Small Single Line Cryogenic Coupling

Powers Controls TH 192 S Single Temperature Room Thermostat

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

IOM SERIES 820-E/P Electro-Pneumatic Positioner

Proportional Relief Valves

Easy Tool Retracting System CMC-SR2159ER36

Stainless Steel Valves For the Sanitary Industries

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

James M. Pleasants Company

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

! WARNING. Before using product, read and understand instructions.

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Air-Oxygen Blender. Service Manual. Model No. PM5200 Series PM5300 Series (shown)

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

PRESSURE REDUCING CONTROL VALVE

These features have made Lo Torc valves the choice of high pressure plug value users, worldwide:

Fisher 1061 Pneumatic Piston Rotary Actuator with Style F & G Mounting Adaptations

TYPE E Main Valve Sizes 3 /8 through 12

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

SureSite Magnetic Liquid Level Indicator

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

DeZURIK 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT

Model 43AP Pneumatic Controller, Style B

STABITHERM INSTALLATION & SERVICE BOOKLET

MCR1900 Media Converter 19-Slot Chassis

Series Hose Reels

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250/F-350 Single Wheel 2WD Ford F350 Dually 2WD IMPORTANT NOTES

Installation, Maintenance, & Repair Series 4000B/LF4000B

V47 Series Temperature Actuated Modulating Water Valves

Pallet Jack. OWNER S MANUAL Model MH1230. Important Safety Instructions Assembly Instructions Parts and Hardware Identification

A99B Series Temperature Sensors

Fisher 249 Caged Displacer Sensors

TECHNICAL DATA. Dry 122a. November 12, 2013

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

Model 5600 & 5600 Econominder

STC 3S A Series Solenoid Valves

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

Universal Adjustable Fuel Pressure Regulator

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

Submersion/Insertion Toroidal Sensor

Installation and Maintenance Instructions

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Your safety and the safety of others are very important.

Oil and Coolant Circulating Heating System. Model - OCSM

Installer s Guide 18-AH39D1-13

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

SELF-STEERING AXLE TABLE OF CONTENTS

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Ball Valves (HB Series) Catalog 4121-HB Revised, April 2005

NITROUS TRANSFER PUMP INSTRUCTIONS

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Tech Bulletin. Hose / Cord Replacement and Required Wraps. Series RT

Shut-off & Lockout Valves 1/4" to 1-1/2" port size

Installing a Probe. Typical Installation

TY-FLO Needle Valves

Trunnion-Design Ball Valves

SELECTION, APPLICATION AND MAINTENANCE

TECHNICAL INSTRUCTIONS REPAIR KITS Hydroguard Series 420 Thermostatic Valve All Models (1 9)

AMX300 DirectConnect Mixing Valve Kits

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250 Single Wheel 4WD Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113)

Before installation it is important to know what parts you have and what the capabilities of these parts are.

HM Series - DBB. Single, Double Block & Bleed Valves. Continuously Improving Flow Control

Valves, Automation & Controls. series 84 /99 HIGH PERFORMANCE 3-PIECE BALL VALVE REDUCE & FULL PORT, STANDARD & FIRE SAFE.

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Installation Instructions

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

Transcription:

Sample Probe Module User s Manual A Swagelok Pre-Engineered Subsystem Pre-engineered subsystems available in weeks, not months. Field-tested design ensures optimum system performance.

2 Contents System Manual............... 3 Introduction 4 Configurations 4 Dimensions 6 Installation 10 Operation 16 Maintenance............................ 17 SPV Heater Option 19 SPV Probe Packing Gland Lockout Bracket Option 23 Troubleshooting 25 System Component User Instructions...............27 Swagelok Tube Fitting Instructions for 1 in. (25 mm) and smaller fittings, MS-12-01 27 Packing Adjustment for 40G Series Ball Valves, MS-INS-40G 28

3 Sample Probe Module (SPM) System Manual

4 Introduction The Swagelok (SPM) is a pre-engineered solution for use in online process analyzers, that consists of a welded sample probe (SPW) or retractable probe (SPR) and a block-andbleed sample probe valve (SPV). Configurations The SPV is available in four configurations. See the Application Guide, MS-02-425, for additional information. Secondary block valve SPV61 The SPV61 is a double block and bleed valve containing a primary block valve, a secondary block valve, and a bleed valve. No interlocks are used on this configuration. This configuration is intended for use with welded probes. Bleed valve Primary block valve SPV61 SPV62 The SPV62 is a double block and bleed valve containing a primary block valve, a secondary block valve, and a bleed valve with the addition of mechanical valve interlocks between the primary block valve and the bleed valve. This configuration is intended for use with welded probes. Secondary block valve Bleed valve Valve interlocks Primary block valve SPV62

5 Configurations SPV63 The SPV63 is a single block and bleed valve containing a primary block valve, a bleed valve, and a probe lock spool with a patent pending probe interlock. The spool has thru-hole geometry optimized for 1/4 in. and 3/8 in. retractable tube probes. Probe lock spool Bleed valve Block valve SPV63 SPV64 SPV64 a single block and bleed valve containing a primary block valve, a bleed valve, and a probe lock spool with a patent pending probe interlock with the addition mechanical valve interlocks between the primary block valve and the bleed valve. The SPV64 is optimized for 1/4 in. and 3/8 in. retractable tube probes. Probe lock spool Valve Interlocks Bleed valve Block valve SPV64

6 Dimensions Dimensions, in inches (millimeters), are for reference only and are subject to change. SPW Welded Probes Outlet and Inlet Flange ASME B16.5 Flanges B D dia, E number of holes Nominal Flange Size 3/4 in. 1 in. 1 1/2 in. 2 in. ASME Dimensions, in. Mounting Holes Class A B C D E 150 3.88 2.75 0.57 0.62 4 600 4.62 3.25 1.13 0.75 4 1500 5.13 3.50 1.51 0.88 4 150 4.25 3.12 0.63 0.62 4 600 4.88 3.50 1.20 0.75 4 150 5.00 3.88 0.76 0.62 4 600 6.12 4.50 1.39 0.88 4 1500 7.00 4.88 1.76 1.13 4 150 6.00 4.75 0.83 0.75 4 600 6.50 5.00 1.51 0.75 8 DIN 2526 Form C Flanges C 8.0 to 36 in. (203 to 914 mm) A Nominal Flange Size 25 mm 40 mm 50 mm DIN Dimensions, mm Mounting Holes Class A B C D E PN16 115 85 18 14 4 PN40 115 85 20 14 4 PN16 150 110 19 18 4 PN40 150 110 21 18 4 PN16 165 125 21 18 4 PN40 165 125 23 18 4 Probe with Flush Flange Outlet JIS B2220 Flanges Nominal Flange Size 25 mm 40 mm 50 mm JIS Dimensions, mm Mounting Holes Class A B C D E 16 125 90 15 19 4 40 130 95 23 19 4 16 140 105 18 19 4 40 160 120 26 23 4 16 155 120 18 19 8 40 165 130 28 19 8

7 Dimensions SPW Welded Probes SPR Retractable Probes 3.00 (76.2) 8.0 to 36 (203 to 914) 2.56 (65.0) 8.0 to 36 in. (203 to 914 mm) 1.00 (25.4) cap hex 1.00 (25.4) body hex 1/2 in. male NPT A Probe with Stub Outlet Stop collar 0.23 0.25 (5.8) (6.4) Tube Size A, in. (mm) 1/4 in. 0.38 (9.6) 3/8 in. 0.50 (12.7)

R R R 8 Dimensions Dimensions, in inches (millimeters), are for reference only and are subject to change. Double Block-and-Bleed SPV Sample Probe Valves (SPV61, SPV62) 0.87 (22.1) 1.44 (36.6) 0.55 (14.0) orifice SPV62 Shown 3.21 (81.5) 1.88 (47.8) Maximum thickness of insulation 5.54 (141) A 10.6 (269) 4.64 (118) 6.01 (153) Inlet Size A, in. (mm) 1/2, 3/4 in. 9.48 (241) 1 in. 9.74 (247)

R R 9 Dimensions Single Block-and-Bleed SPV Sample Probe Valves (SPV63, SPV64) 0.87 (22.1) 1.44 (36.6) 0.55 (14.0) orifice SPV64 Shown 3.21 (81.5) 1.88 (47.8) Maximum thickness of insulation 4.50 (114) A 10.4 (264) 4.64 (118) 6.01 (153) Inlet Size A, in. (mm) 1/2, 3/4 in. 8.44 (214) 1 in. 8.69 (221) Weight, All Configurations 22 lb (10 kg)

10 Installation SPV61 and SPV62 Sample Probe Valve with SPW Welded Probe Installation Warning Depressurize the system before installing the SPV and SPW. 1. Relieve pressure from the system. 2. Verify the probe is the correct length for your application. Swagelok recommends the end of the probe reach the middle third of the process pipe. 3. Connect the SPW probe to a flanged process nozzle. Use the visual indicator on the flange to orient the angled cut on the end of the probe downstream. 4. Actuate all valves on the SPV to the closed position. Probe Visual Indicator 5. Connect the SPV inlet to the SPW. a. SPW with pipe stub outlet - connect the SPV inlet directly to the NPT pipe stub on the SPW. (Use adapter fittings as necessary for different size connections.) b. SPW with flange outlet - use a flange adapter and appropriate pipe fittings (not supplied) to connect the SPV inlet to the SPW outlet flange. 6. Connect the outlet of the SPV to the system outlet line. 7. Connect the bleed valve outlet of the SPV to the system vent line. 8. If necessary, add support by mounting to any of the four heater mounting holes (longer M8 bolts may be needed) or the two thru holes on the lower left corner of the body. Additional support is more likely to be needed when any of the following conditions exist. a The SPV is mounted horizontally. b The SPV does not have a rigid outlet or bleed valve outlet connection (Configurations 61 and 63). c The SPV does not have a heater connected with rigid conduit. d The SPV inlet connection is 1/2 in. NPT. e The valve will experience significant vibration. 9. Supply pressure and check for inlet connection leaks using Snoop liquid leak detector. 10. Open the primary and secondary block valves and check for connection leaks using Snoop liquid leak detector.

11 Installation Outlet Bleed valve outlet Secondary block valve Bleed valve Primary block valve Inlet SPW with stub option Flanged process interface nozzle SPV62 with SPW Welded Probe

12 Installation SPV63 and SPV64 Sample Probe Valve with SPR Retractable Probe Installation Warning You must depressurize the system before installing the SPV and SPR. 1. Relieve pressure from the system. 2. Actuate both valves and the probe lock spool on the SPV to the closed position. 3. Connect the valve inlet to the sample supply line. 4. Connect the bleed valve outlet to the system vent line. 5. Verify the probe is the correct length for your application. Swagelok recommends the end of the probe reach the middle third of the process pipe. 6. For SPRs without the optional probe isolation valve, install an appropriate isolation valve to the outlet of the tube probe. Orient the valve with the handle upstream. 7. Actuate the isolation valve to the closed position. 8. Connect the retractable probe packing gland body to the 1/2 in. NPT SPV outlet. 9. Tighten the probe packing gland cap according to the table. 10. If necessary, add support by mounting to any of the four heater mounting holes (longer M8 bolts may be needed) or the two thru holes on the lower left corner of the body. Additional support is more likely to be needed when any of the following conditions exist. a The SPV is mounted horizontally. b The SPV does not have a rigid outlet or bleed valve outlet connection. c The SPV does not have a heater connected with rigid conduit. d The SPV inlet connection is 1/2 in. NPT. e The valve will experience significant vibration. 11. Check for inlet connection leaks using Snoop liquid leak detector. 12. Open the primary block valve. Verify the bleed valve is in the closed position. Check for connection leaks using Snoop liquid leak detector. 13. Open the probe lock spool. 14. Slightly loosen the probe packing gland cap 1/64 turn at a time until the probe can be inserted through the SPV. 15. Install the probe to the desired insertion depth. Use the visual indicator on the tube probe for orientation. Fluorocarbon FKM 55 to 60 (74.5 to 81.3) Seal Material PTFE Grafoil Torque, ft lb (N m) 55 to 60 (74.5 to 81.3) 90 to 100 (122 to 135) 16. Set the probe in the desired orientation, typically with the cut angle facing downstream. Tighten the packing gland cap according to the table. 17. Supply pressure and check for connection leaks using Snoop liquid leak detector. 18. Connect the outlet port of the probe isolation valve to the system outlet line.

13 Installation Probe isolation valve Tube probe Outlet Cap Body Probe packing gland Bleed valve Bleed valve outlet Primary block valve Probe lock spool (red handle) Inlet SPV64 with SPR Retractable Probe

14 Installation SPV Sample Probe Valve Installation Assemble Swagelok tube fittings according to Swagelok Tube Fitting Installations for 1 in. (25 mm) and Smaller Fittings, page 27. Warning You must depressurize the system before installing the SPV. 1. Relieve pressure from the system. 2. Actuate all valves to the closed position. 3. Connect the valve inlet to the sample supply line. 4. Configurations 61 and 62 only: Connect the outlet to the outlet line. 5. Configurations 63 and 64 only: It is recommended to plug the outlet port until a retractable probe is installed. 6. Connect the bleed valve outlet to the system vent line. 7. If necessary, add support by mounting to any of the four heater mounting holes (longer M8 bolts may be needed) or the two thru holes on the lower left corner of the body. Additional support is more likely to be needed when any of the following conditions exist. a The SPV is mounted horizontally. b The SPV does not have a rigid outlet or bleed valve outlet connection (Configurations 61 and 63). c The SPV does not have a heater connected with rigid conduit. d The SPV inlet connection is 1/2 in. NPT. e The SPV will experience significant vibration. 8. Supply pressure to the valve and check for connection leaks using Snoop liquid leak detector. Note: The probe interlock valve on Configurations 63 and 64 does not have a seat shut-off seal and will always allow flow to pass through in both the open and closed positions. 9. Open the primary block valve and check for connection leaks using Snoop liquid leak detector. 10. Open the secondary block valve and check for connection leaks using Snoop liquid leak detector (Configurations 61 and 62).

15 Installation Outlet Secondary block valve Bleed valve outlet Mounting holes Inlet Primary block valve SPV61

16 Operation General notes: 1. The valve is closed when the handle crosses the flow path. 2. The valve is open when the handle is inline with the flow path. SPV61 All valve handles are free to open and close. SPV62 The secondary block valve (SBV) is free to open and close. The primary block valve (PBV) and the bleed valve (BLV) are interlocked which prevents specific valve handles from being actuated under certain conditions. When either the PBV or BLV is open the other is locked closed. The PBV and the BLV can be closed at the same time. SPV64 The valve contains a primary block valve (PBV), a bleed valve (BLV) and a probe lock spool (PLS), with interlocks between the PBV and PLS as well as valve interlocks between the PBV and BLV. The primary block valve (PBV) and the bleed valve (BLV) are interlocked which prevents specific valve handles from being actuated under certain conditions. When either the PBV or BLV is open the other is locked closed. The PBV and the BLV can be closed at the same time. The primary block valve (PBV) can only be closed when the probe lock spool (PLS) is in the closed position. This prevents a probe from being inserted through the valve and damaging the PBV sealing ball. When the PBV is in the closed position, interlocks prevent the PLS from being opened. When the PBV is in the open position the PLS can be opened to allow the insertion of a retractable probe. SPV63 The bleed valve (BLV) is free to open and close. The primary block valve (PBV) can only be closed when the probe lock spool (PLS) is in the closed position. This prevents a probe from being inserted through the valve and damaging the PBV sealing ball. When the PBV is in the closed position, interlocks prevent the PLS from being opened. When the PBV is in the open position the PLS can be opened to allow the insertion of a retractable probe.

17 Maintenance Follow these steps before performing any downstream system maintenance. SPV Sample Probe Valve with SPW Welded Probe 1. Close the primary block valve. 2. Open the bleed valve. Note: This will depressurize the downstream analytical system to the next check valve. 3. Close the secondary block valve. Warning The probe is still under pressure from the process line. Depressurize the process line and system before performing any maintenance on the valve or the probe. Bleed valve (shown closed) Secondary block valve (shown open) Primary block valve (shown open) SPV62 with SPW Welded Probe

18 Maintenance SPV Sample Probe Valve with SPR Retractable Probe - Removing the Probe WARNING Excessive loosening of the probe packing gland will result in sudden extraction of the probe from the system or leakage. 1. Slightly loosen the probe packing gland cap 1/64 turn at a time until the probe can be retracted by pulling it through the SPV. 2. Pull the probe through the SPV until the stop collar contacts the probe packing gland body. 3. Close the probe lock spool (PLS). 4. Close the primary block valve (PBV). 5. Open the bleed valve (BLV). Note: This will depressurize the downstream analytical system to the next check valve. 6. Remove the probe from the SPV by removing the probe packing gland body. Probe isolation valve Cap Body Probe packing gland Primary block valve Probe lock spool (red handle) SPV64 with SPR Retractable Probe

19 SPV Heater Option General Safety WARNING: HOT SURFACE External surfaces of this product may reach temperatures of over 250 F (120 C) during normal operation. Configurations The optional heater comes in two voltages (120 VAC or 240 VAC) and the heater block comes in two materials (316 stainless steel or black anodized aluminum). All heaters contain a non-resettable thermal fuse that interrupts power to the heater before the heater reaches 392 F (200 C). All heaters include a solid state PID temperature controller that can be adjusted from 50 to 300 F (10 to 148 C) 3/4 in. Female NPT Heater Assembly

20 SPV Heater Option Heater Installation SPV heater kits mount to the SPV to heat and maintain a specific temperature. The heater can be set to maintain the heater block temperature from 50 F to 300 F (10 C to 148 C). The environmental temperature rating of the heater is -4 F to 122 F (-20 C to 50 C). Kit Contents Heater assembly (4) M8 55 hex head screws SPV62 with Heater Installed (4) M8 lock washers Tools needed 13 mm wrench or socket Torque wrench capable of 120 in. lbs (13.5 N m)

21 SPV Heater Option Heater Installation 1. Remove the four M8 hex screws covering the heater mounting holes on the valve body mounting surface. 2. Clean the valve body mounting surface. 3. Position the heater on the body and assemble using the supplied M8 55 mounting bolts and washers. Tighten the bolts to 120 in. lbs (13.5 N m). 4. Remove the junction box cover and make the wire and conduit connections. The installation must meet local codes. The junction box has a 3/4 in. female NPT thread connection. The electrical source and wires must meet the minimum wire gauge size and maximum current draw for a 110/240 VAC 500W 50/60 Hz heater draw. M8 55 mounting bolt WARNING Disconnect power to the heater before opening electrical box lid. Failure to do so may result in electric shock and may also present an explosion hazard. WARNING The supply must not exceed 110 % of the rated voltage. CAUTION Use appropriate wire and connections to withstand the temperature range of the heater. Note: There is a limited thread engagement of the terminal block mounting screws in the aluminum mounting plate. The use of anaerobic thread locking adhesive and a low tightening torque are recommended. a Make a ground connection, an internal ground and an external ground screw are provided. b Connect the AC supply to the standoff pillars labeled 2 and 4. 5. Replace the junction box cover. 6. The handles on the SPV valve have large stand-off distances to accommodate up to 1 in. (25 mm) thick insulation around the heater and valve assembly. Internal ground lead External ground screw Lock washer Valve body mounting surface SPV62 with Heater AC supply connected to top of standoff pillars 2 and 4. 3/4 in. NPT gland connection Thermistor wire (blue) Heater wire (tan) Heater Wire Connections

22 SPV Heater Option Heater Operation WARNING Disconnect power to the heater before opening electrical box lid and setting the temperature. Failure to do so may result in electric shock and may also present an explosion hazard. 1. Disconnect power to the heater. 2. Remove the electrical box lid. 3 Turn the adjuster screw located on the control unit to the required temperature position/setting as indicated on the label. Note: Turn the screw fully counterclockwise for position 1 and fully clockwise for postion 3. 4. Replace the electrical box lid. 5. Reconnect unit to power. Note: It is recommended to insulate the valve and heater assembly by wrapping the assembly with insulation when there is a temperature difference of more than 50 F (10 C) between the set temperature and the environmental temperature. Allow at least 60 minutes for the temperature to reach the revised set point. The temperature of the valve body can be monitored using the optional dial thermometer or by other user supplied means. Depending on environmental conditions and whether the valve is insulated, more time may be required for the heater to reach the set temperature. Adjuster screw Internal ground lead External ground screw 3/4 in. NPT Gland connection Thermistor wire (blue) Heater wire (tan) Heater Wire Connections AC supply connected to top of standoff pillars 2 and 4.

23 SPV Probe Packing Gland Lockout Bracket Option Configuration This option prevents unintentional loosening of the probe packing gland cap or removal of the probe fitting with a retractable probe. Installation The probe lock kit is designed to be installed on SPV Configurations 63 or 64. Kit Contents: Base plate Cover plate (1) M8 countersink screw SPV64 with Probe Gland Lockout Bracket (1) M8 shoulder screw Tools needed: 5 mm hex key (1) Flat washer (1) Wave spring washer 13 mm wrench or socket Thread lock adhesive Torque wrench capable of 120 in. lbs (13.5 N m)

24 SPV Probe Packing Gland Lockout Bracket Option Installation 1. Remove the two existing M8 hex screws. 2. Align both holes in the base plate to the threaded holes on the SPV body. 3. Apply a couple drops of thread lock adhesive to the thread of the M8 countersink screw. Use the M8 countersink screw to hold the base plate in position but do not tighten at this time. 4. Place the cover plate on top of the base plate and align the left hole in the cover plate with the left hole on the base plate with the left threaded hole on the SPV body. 5. Place the wave spring washer then the flat washer over the shoulder of the M8 shoulder screw. 6. Apply a couple drops of thread lock adhesive to the thread of the M8 shoulder screw. Install the screw through the cover plate, base plate and into the valve body. Turn the shoulder screw clockwise until the shoulder fits through the washer and cover plate and stops against the base plate but do not tighten at this time. Note: The cover plate will lock in position if the washer is not aligned properly. 7. Rotate the cover plate counterclockwise to expose the M8 countersink screw. Tighten the M8 countersink screw to 120 in. lbs (13.5 N m). 8. Tighten the M8 shoulder screw to 120 in. lbs (13.5 N m). The cover plate can should swing/pivot from the fully open position to the fully locked position and the lock ring on the cover plate should pass through the slot on the base plate. Cover plate Base plate Flat washer Wave spring washer M8 shoulder screw M8 countersink screw Exploded View of Probe Packing Gland Lockout Bracket Option

25 Troubleshooting Symptom Cause Remedy Primary block valve will not open. Bleed valve will not open. Primary block valve will not close. Probe lock valve will not fully open. Probe lock valve will not fully close. Low flow or no flow downstream of the tube probe. Sample response time is too slow. There is leakage around the packing gland. SPM Troubleshooting SPV62 and SPV64 Primary block valve is locked closed by the bleed valve. Bleed valve is locked closed by the primary block valve. SPV63 and SPV64 Primary block valve is locked open by the probe lock valve. Probe lock valve is locked closed by the primary block valve. A probe is installed through the valve and preventing the probe lock valve from closing. The probe is impeding closing of the probe lock valve. SPR and SPW assemblies The probe is partially or fully clogged. The angle cut on the probe end is incorrect. Excessive internal volume. Excessive gas pressure. The packing gland cap needs to be adjusted. The packing gland sealant needs to be replaced. Close the bleed valve. The bleed valve must be closed before the primary block valve can be opened. Close the primary block valve. The primary block valve must be closed before the bleed valve can be opened. Retract the probe (if installed) then close the probe lock valve. The probe lock valve must be closed before the primary block valve can be closed. Open the primary block valve. The primary block valve must be opened before the probe lock valve can be opened. Fully retract the probe until the stop collar contacts the packing gland body. Close the probe lock valve. Verify that the probe is fully retracted. If it is, then the distance from the back stop of the stop collar to the end of the probe may be too long. Clean out the probe. Consider a probe with a larger inside diameter. Change the probe orientation so the open end faces downstream. Reduce the internal volume. Consider a probe with a smaller inside diameter. Reduce the gas pressure downstream. Consider installing a Swagelok Field Station Module immediately downstream. Tighten the packing gland cap according to the torque table on page 12. Replace the packing gland sealant.

26 Troubleshooting Symptom Cause Remedy Heater block does not heat up and reach the set temperature. Heater block does not cool down and reach the set temperature. Temperature fluctuates and does not stabilize. Heater Troubleshooting Heater not getting appropriate power. Controller set temperature is below ambient temperature. Thermal fuse tripped. Faulty reading from thermistor. Excessive heat losses preventing heater from reaching set temperature or causing more time for heater to reach the set temperature. Controller set temperature is below ambient temperature. Faulty reading from thermistor. Cooling down takes too long. Ambient or process temperature is fluctuating. Controller PID settings too aggressive for the application. Check voltage at the supply terminals 2 and 4. Should be around 120V or around 240V, depending on heater. Adjust controller set temperature to above ambient temperature. Check continuity across terminals 1 and 4. If no continuity then replace heater block. Check resistance across terminals 2 and 3. If the resistance is zero or infinity then thermistor is faulty. Return unit to factory. A properly functioning thermistor will show a steady increase in resistance while heating up and a steady decrease while cooling down. Insulate valve body and heater or decrease the set temperature. Ambient temperature must be below controller set temperature and the process temperature for heater to cool down. Adjust controller set temperature to above ambient temperature or reduce ambient temperature or reduce process temperature. Check resistance across terminals 2 and 3. If the resistance is zero or infinity then thermistor is faulty and return unit to factory. A properly functioning thermistor will show a steady increase in resistance while heating up and a steady decrease while cooling down. Larger temperature differences between set point and ambient temperatures may result in increased cooling times. Allow more time for heater to cool down. Reduce ambient and/ or process temperature fluctuations. Reset controller and if symptom/problem persists return unit to factory.

27 Swagelok Tube Fitting Instructions for 1 in. (25 mm) and smaller fittings Fig. 5 Fig. 1 Fig. 2 Fig. 6 Fig. 3 Fig. 4 Installation These instructions apply to both traditional fittings and to fittings with the advanced backferrule geometry. 1 Fully insert the tube into the fitting and against the shoulder; rotate the nut fingertight. Fig. 1. High-Pressure Applications and High Safety-Factor Systems: Further tighten the nut until the tube will not turn by hand or move axially in the fitting. 2 Mark the nut at the 6 o clock position. Fig. 2. 3 While holding the fitting body steady, tighten the nut one and one-quarter turns to the 9 o clock position. Fig. 3. Note: For 1/16, 1/8, and 3/16 in.; 2, 3, and 4 mm tube fittings, tighten the nut three quarters turn to the 3 o clock position. Gaugeability On initial installation, the Swagelok gap inspection gauge assures the installer or inspector that a fitting has been sufficiently tightened. Position the Swagelok gap inspection gauge next to the gap between the nut and body. Fig. 4. If the gauge will not enter the gap, the fitting is sufficiently tightened. If the gauge will enter the gap, additional tightening is required. Reassembly Instructions You may disassemble and reassemble Swagelok tube fittings many times. Warning Always depressurize the system before disassembling a Swagelok tube fitting. 1 Prior to disassembly, mark the tube at the back of the nut; mark a line along the nut and fitting body flats. Fig. 5. Use these marks to ensure you return the nut to the previously pulled-up position. 2 Insert the tube with preswaged ferrules into the fitting body until the front ferrule seats against the fitting body. Fig. 6. 3 While holding the fitting body steady, rotate the nut with a wrench to the previously pulled-up position as indicated by the marks on the tube and the flats; at this point you will feel a significant increase in resistance. Fig. 7. 4 Tighten the nut slightly. Fig. 7 Caution Do not use the gap inspection gauge with reassembled fittings. Caution Do not mix or interchange parts with those of other manufacturers. For additional information, see the Gaugeable Tube Fittings and Adapter Fittings catalog, MS-01-140.

28 40G Series Valve Packing Adjustment IMPORTANT This valve is factory tested with nitrogen at 1000 psig (69 bar), or the rated pressure if lower than 1000 psig (69 bar). Periodic maintenance: Packing adjustments may be required during the service life of the valve to prevent leakage. Adjusting the Packing 1. Adjust the packing by turning the packing bolt clockwise in 1/16-turn increments until leak-tight performance is achieved. 2. Test valve for proper function and operation. Before removing any installed valve from the system, you must depressurize the system cycle the valve purge the valve

29

Warranty Information Swagelok products are backed by The Swagelok Limited Lifetime Warranty. For a copy, visit swagelok.com or contact your authorized Swagelok representative. Swagelok, Snoop TM Swagelok Company Conax TM Conax Technologies, Grafoil TM GrafTech Internation Holdings, Inc. 2011 Swagelok Company April 2011, R0 MS-13-220