500 SERIES - SAFETY VALVE

Similar documents
Non-Code Liquid Relief, ASME Section VIII, Air/Gas and Steam, National Board Certified, Safety and Relief Valves

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

Float and Thermostatic Traps Series H, C and X

The First Line of Safety

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

KUNKLE SAFETY AND RELIEF VALVE PRODUCTS OVERVIEW

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

Your safety and the safety of others are very important.

T&P and ASME Safety Relief Valves

Operation & Maintenance Manual

TECHNICAL DATA. Dry 122a. November 12, 2013

How To Make A Pressure Relief Valve

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi

Installation Manual DIAPHRAGM WELL TANK

! WARNING. Before using product, read and understand instructions.

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

INDIRECT WATER HEATER. Installation and Operating Instruction Manual

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

Installation Manual DIAPHRAGM WELL TANK

1805 Series Relief Valves

AMX300 DirectConnect Mixing Valve Kits

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

TYPE E Main Valve Sizes 3 /8 through 12

BERMAD Fire Protection

needle valves Needle Valves Index At a Glance 1

Blowdown vessels Meeting the requirements of HSE PM60

Air Eliminators and Combination Air Eliminators Strainers

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

NITROUS TRANSFER PUMP INSTRUCTIONS

VAD. Variable Area Desuperheaters

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

V47 Series Temperature Actuated Modulating Water Valves

relief valves 500 Series Adjustable Popoff & Inline Relief Valves 0.5 to 150 psig (10 bar)

TD01211 PIN: NX nd Edition. Water Motor Alarm MODEL: NX010 TECHNICAL DATA

AIR LINE VALVES AND GAUGES

Type 92S Pilot-Operated Steam Regulator

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

SV615 Safety Valve. 1. Safety information. 2. Product information. 3. Supply. 4. Handling. 5. Before fitting the valve. 6.

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

Ball Valves (HB Series) Catalog 4121-HB Revised, April 2005

OSHA Tank Venting DEFINITIONS

Select Radiators Installation Guide

API Flanged Safety Relief Valves Series 526 CATALOG

Pentair Pressure Relief Valve Engineering Handbook

Types 66R and 66RR Low-Pressure Relief Valves

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN

APCO SLOW CLOSING AIR/VACUUM VALVES

Morrison Bros. Co. General Product Specifications

Steam Coil Installation, Operation and Maintenance

Submersion/Insertion Toroidal Sensor

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

Automatic Self-Cleaning Strainers

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) Internet Address:

Type 119 Control Valve

TECHNICAL DATA 2. LISTINGS AND APPROVALS. Spray Nozzle 11. December 20, 2013

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

PBX Series Quick Fit Connector Bimetallic Steam Traps

IMPORTANT SAFETY NOTICE

Select the Right Relief Valve - Part 1 Saeid Rahimi

Proportional Relief Valves

BLADDER SURGE CONTROL SYSTEM

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

OPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES

NFPA31FuelOilPiping 1 Revised

CEILING CASSETTE FAN COIL UNIT

CARING FOR YOUR WATER HEATER

NORMAN FILTER COMPANY PRODUCT OVERVIEW

Technical Data. Installation

WATER PRESSURE REDUCING VALVES

PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM

STORED PRESSURE STAINLESS STEEL

Many Products...One Source

WD600 STEAM TRAPS. Thermodynamic Steam Trap

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, Instruction No.

ESFR DRY PENDENT SPRINKLER VK502 (K14.0) TECHNICAL DATA

In-Line Air Separators

Commercial Semi-Instantaneous Water Heaters

FLASH TANK ECONOMIZER PRODUCT GUIDE

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Rated Burst Pressure 200 Series: 2.5 : 1 H200 Series: 4 : 1

167D Series Switching Valves

Oil and Coolant Circulating Heating System. Model - OCSM

James M. Pleasants Company

Commercial Electric Water Heater

Wafer Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Vogt Valves The Connection Bulletin for Forged Steel Flow Control Valves CB 15

REGULATING VALVE APPLICATIONS

Compact. Performance. Safety Relief Valves Serie 437 Serie 459. The-Safety-Valve.com

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Hose Clamps & Fittings

INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303

Fisher 377 Trip Valve

REGULATORS 175/153 Series

Baumann Way Bronze or Stainless Steel Control Valve

Transcription:

INDUSTRIES, INC. 500 SERIES - SAFETY VALVE INSTALLATION, OPERATION, & MAINTENANCE Part I Document Number: ES-1196-1 Revision Level: D Issued By: T. HAMILTON Date: 3/3/16 Approved By: Date: Conbraco Industries, Inc. P.O. Box 247 Matthews, NC 28106 (704) 841-6000 Fax (704) 841-6020 http://www.conbraco.com

Table of Contents Maximum Pressure/Temperature Chart... 2 Installation Instructions... 3 Operating Instructions... 3 Maintenance and Testing Instructions... 4 500 Series Part Number Matrix... 4 Nameplate Information... 5 Amendment Register... 6 IMPORTANT Conbraco pressure relief valves are safety devices designed for the protection of lives and property. These valves will provide years of service when properly installed and maintained. The information contained herein is intended for use by qualified personnel to properly maintain these devices. Serious property damage and injury or death may occur should a pressure relieving device fail to operate correctly. Any installation, maintenance, adjustment, repair or testing should only be performed by experienced personnel properly trained and qualified in accordance with applicable codes and standards. When maintaining or repairing Conbraco pressure relief valves, use only original Conbraco parts to ensure safe and reliable operation. Contact your local Conbraco factory representative for the name of a factory authorized repair center near you. Or visit us on the web at www.conbraco.com. Maximum Pressure/Temperature Chart Warning Application must not exceed the pressure/temperature limitations below. Series 510 520 530 540 Body Trim Bronze Brass Bronze Carbon Steel Max. Set Steam 250 psi (1724 kpa) 300 psi (2068 kpa) 900 psi (6205 kpa) D/E 900 psi (6205 kpa) D/E Max. Set Air/Gas/Liquid 300 psi (2068 kpa) 900 psi (6205 kpa) D/E 900 psi (6205 kpa) D/E 900 psi (6205 kpa) D/E Max. Temperature 406ºF (208ºC) 422ºF (217ºC) 800ºF (427ºC) 800ºF (427ºC) ES1196-1, IOM, 500 Series Rev. D 2

Installation Instructions This quality Conbraco safety valve, along with proper installation, use and maintenance will provide many years of reliable service and protection against excessive pressure build-up of steam, air or non-hazardous gas. Use of this valve for any other purpose or media places all responsibility upon the user. Before installing valve, or operating equipment to which it is installed, read all instructions carefully. Caution - Always wear proper safety equipment. Caution Valve may be very hot to the touch. Wear protective equipment if necessary. 1. Installation must be performed by qualified service personnel only. 2. It is the piping system designer s responsibility to implement appropriate protective measures to minimize reaction forces and moments which result from supports, attachments, piping, etc. 3. Service is to be compatible with the materials of construction. Prior to selection it is the user s responsibility to determine that the valve is appropriate for the intended application. Application not to allow corrosion >.001 /year (.025 mm/year). 4. The capacity rating of this valve must equal or exceed that of the equipment to which it is installed. 5. Do not use the test lever as a lifting device during installation. 6. Insure that all connections, including the valve inlet, are clean and free of any foreign material. 7. Use pipe compound sparingly or tape on external threads only. 8. Do not use a pipe wrench! Use proper type and size wrench on wrench pads only. 9. Valves for compressible fluid service shall be connected to the vessel in the vapor space above any contained liquid or to piping connected to the vapor space on the vessel which is to be protected. Mount in a vertical upright position. Vacuum Relief: Install female NPT to vacuum source, male NPT open to atmosphere. Do not plug or cap male NPT. Valves for use in liquid service shall be connected below the normal liquid level. 10. Do not plug or obstruct valve body drain. A body drain line should be installed to dispose of condensate. 11. See ASME Boiler and Pressure Vessel Code and local jurisdiction for additional installation and operating instructions. Caution - During operation, this valve may discharge large amounts of high pressure steam, hot liquid, air or gas. To reduce the potential for bodily injury and property damage, a discharge line must be installed that: a) is connected from the valve outlet to a safe point of discharge with no intervening valve; b) allows complete drainage of the valve and discharge line; c) is independently supported and securely anchored to avoid applied stress on the valve; d) is as short and straight as possible; e) is, over it s entire length, of a pipe size equal to or greater than the valve outlet. Use only schedule 40 pipe for discharge. Do not use schedule 80, extra strong or double strong pipe or connections. Do not cap, plug or obstruct discharge pipe outlet! If discharge is piped upward, a condensate drain must be provided in the elbow below the vertical pipe to prevent condensate from returning into the valve. A Conbraco Drip Pan Elbow is ideal. Operating Instructions To achieve topmost performance and maximum service life, it is necessary to maintain a proper pressure margin between the set pressure of the safety valve and the operating pressure of the equipment. The minimum recommended operating pressure margin for this type of safety valve is 5 psi or 10% of the nameplate set pressure, whichever is greater. Failure to maintain this operating margin may result in leakage past the seat and an accumulation of deposits on the seating surface. Excessive deposits may prevent the safety valve from operating properly, and a dangerous pressure build-up and equipment rupture may result. ES1196-1, IOM, 500 Series Rev. D 3

Maintenance and Testing Instructions CAUTION! Before testing, make certain discharge pipe is properly connected to valve outlet and arranged to contain and safely dispose of discharge (see Installation Instructions). Under normal operating conditions a try lever test should be performed biannually in steam service, with a visual inspection every 2 months and an annual pressure test. In air/gas service, perform a visual inspection every 6 months, a lever test annually (when so equipped) and a pressure test every 3 years. Under severe service conditions or if corrosion, pitting, and/or deposits are noticed within the valve body, testing must be performed more often. A try lever test should be performed at the end of any non-service period. CAUTION! Hot, high pressure fluid may be discharged from body drain during lever test. CAUTION! High sound levels may be experienced during lever test. Wear proper safety equipment and exercise extreme care. Test at or near maximum operating pressure by holding the test lever fully open for at least five seconds to flush the valve seat free of sediment and debris. Then release lever and permit valve to snap shut. If lift lever does not actuate, or there is no evidence of discharge, turn off equipment immediately and contact a licensed contractor or qualified service personnel. For resetting, adjustment or repairs contact Conbraco Industries for the location of the nearest authorized service facility. Neither Conbraco Industries, Inc. nor it s agents assume any liability for valves improperly installed or maintained. 500 Series Part Number Matrix EX: 523JHBKMAA0125 POSITION OPTION 1 SERIES # 5 = 500 SERIES 2 BODY/TRIM 1 = BRONZE/BRASS 2 = BRONZE/STAINLESS STEEL 3 = CARBON STEEL/STAINLESS STEEL 4 = STAINLESS STEEL/STAINLESS STEEL 3 - CAP 1 = SCREWED CAP 2 = SCREWED CAP W/GAG 3 = PACKED LEVER 4 = PACKED LEVER W/GAG 4 ORIFICE SPECIFY D/E/F/G/H/J 5 INLET C = ½ NPT D = ¾ NPT E = 1 NPT F = 1-1/4 NPT G = 1-1/2 NPT H = 2 NPT 6 CONNECTION B = MNPT INLET x FNPT OUTLET D = MNPT x 3/4FNPT OUTLET, D ORIFICE, BRONZE BODY ONLY 7 SERVICE J = UV LIQUID K = UV AIR L = UV STEAM M = NON-CODE LIQUID N = NON-CODE AIR P = NON-CODE STEAM Q = VACUUM SERVICE 8 SEAT M = METAL B = NITRILE/BUNA-N E = EPR K = PCTFE (CRYOGENIC SERVICE) S = SILICONE N = NEOPRENE V = VITON 9-10 - OPTIONS AA = DEFAULT; FACTORY ISSUED LETTERS/NUMBERS FOR SPECIAL OPTIONS 11-14 SET PRESSURE 4 DIGITS, 0005 THRU 0900, PSIG; VACUUM SERVICE, HG05 THRU HG30, Hg ES1196-1, IOM, 500 Series Rev. D 4

Nameplate Information CRN 0G8547.5C Valves ISO 4126-1 C ONBRACO INDUSTRIE S INC., USA MODEL 511DCBLMAA0125 0035 SIZE 1/2 IN DN 12 SET 125 PSIG 8.6 BARG A S M E CAP 873 x LB/HR SCFM GPM DT 0432 DO 10 S 0.86 TS 208 UV N ASME Code Symbol When applicable, the ASME UV stamp will be added in the empty box in the upper right corner. The UV symbol signifies the valve has been designed, manufactured, and tested in accordance with Section VIII of the ASME Boiler and Pressure Vessel Code and is approved for use on unfired pressure vessels and pressure piping systems. NB Symbol This symbol indicates the capacity value stamped on the nameplate has been certified by the National Board of Boiler and Pressure Vessel Inspectors. CRN This number is the design registration number in accordance with CSA B51, the Canadian Boiler, Pressure Vessel and Pressure Piping Code. MODEL This is the valve model number as described in the Part Number Matrix. CAP This is the National Board certified capacity rating of the valve, calculated in accordance with the requirements of ASME Section VIII, Division I. One of the three adjacent boxes will be marked to indicate the units of the capacity rating. SET This is the set pressure of the valve in pounds per square inch and bar gauge. SIZE This is the inlet size of the valve in inches. DN This is the metric size designation of the inlet. DO This is the orifice diameter in millimeters. TS This is the maximum allowable temperature in Celsius. S This is the ASME coefficient of discharge indicating reference fluid: G for gas, S for steam, and L for liquid. DATE This is the date of manufacture. The first two numbers indicate the year (04=2004), and the last two numbers indicate the week of the year (32=32 ND week of the year). ES1196-1, IOM, 500 Series Rev. D 5

Amendment Register DATE REV PAGES DESCRIPTION 4/9/03 A ALL NEW RELEASE 4/29/04 B 5 UPDATED NAMEPLATE GRAPHICS 6/24/04 C 3-5 ADDED VACUUM SERVICE; REVISED NAMEPLATE INFO 3/3/16 D 5 UPDATED NAMEPLATE ES1196-1, IOM, 500 Series Rev. D 6