Driver Feedback Sign DFS 700 Model

Similar documents
Product Specification instalert Rapid Messenger Variable Message Sign

Frequency selective monitoring and logging of environmental electromagnetic fields

Continuous, remote monitoring and logging of electromagnetic fields

Continuous, remote monitoring and logging of electromagnetic fields

DC Electronic Loads 8500 series

Drayton Digistat +2RF/+3RF

siemens.com/mobility Radar detectors of the Heimdall family High detection rate, easy installation

ETSI EN V1.1.1 ( )

Temperature & Humidity SMS Alert Controller

is then retained absolutely without interruption.

TECHNICAL SPECIFICATION FOR GSM MOBILE TERMINALS

Product Information Sheet UH28CS-12kV Hi Pot Tester

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Multi-Range Programmable DC Power Supplies 9115 Series

User manual BETSO WTCS. 16 channel wireless digital TC slate. 1 Copyright BETSO ELECTRONICS Ltd.

Multi-Range Programmable DC Power Supplies 9115 Series

GETTING TO KNOW YOUR PRE-PAID TELSTRA WI-FI 4G

telstra.com/ppmbb visit a telstra store or partner GETTING TO KNOW YOUR

Waveguide Access Point WGA631. Product Guide

GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G WI-FI

TX OPEN RS232/485 module

IDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited

PCS0100en Persy Control Services B.V. Netherlands

R&S UMS12-OEM Monitoring System Modular monitoring system with open programming interface

User Manual for CH-PFC76810

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Danfoss Link Mobile Phone Butler

Manual. Simrad StructureScan LSS-1 Sonar Module. English

GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G USB + WI-FI

Nardalert S3 Non-Ionizing Radiation Monitor

StructureScan HD Module. Installation Guide ENGLISH

FIREDEX Conventional Fire Panels

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

Current Monitoring Kit QUICK START GUIDE

GeoMax GNSS Zenith10 & Zenith20 Series

RADAR SPEED DISPLAYS.

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

IRIS Touch 600 Range Dialler Installation Manual. Version 1.3

Current Monitoring Kit

SECTION DETECTION AND ALARM

USB-500/600 Series Low-Cost Data Loggers and Accessories

FOR MORE INFORMATION or from a non-telstra phone and say pre-paid telstra.com/ppmbb visit a telstra store or partner

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

AC3200 INTELLIGENT BROADBAND AMPLIFIER

The Foundation User Manual LED Battery Slim Par Fixture (RGBA, DMX 7Ch/4CH)

MS9500 SERIES VOYAGER PRODUCT GUIDE. Single Line, Hand-Held, 1D, High-Density 1D, PDF-417 2D and Wireless Laser Bar Code Scanners

BCST-20 Barcode Scanner. Instruction Manual.

Telephone- and leased line modem for industrial applications TD-36

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

FIBRE-OPTICS POWER METER INSTRUCTION MANUAL

SMS GSM Alarm Messenger

WEATHER STATION FOR SOLAR FARM MONITORING

1 Technical Description Lokal-200PC

ETSI EN V2.1.1 ( ) Harmonized European Standard (Telecommunications series)

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Redundancy Module QUINT-DIODE/40

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Targus Wireless Remote Presenter USER S GUIDE. Making Your Mobile Life Easier. Making Your Mobile Life Easier.

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Digital input modules

ETSI EN V1.2.2 ( )

Uninterruptible Power Supply

Long Distance Industrial Wireless Transmitters and Receivers

USER MANUAL V5.0 ST100

Vehicle IOT Gateway Family Datasheet

USB-500/600 Series Low-Cost Data Loggers and Accessories

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Remote Monitoring and REC 501 Control Unit Product Guide

T Substation Maintenance and Commissioning Test Equipment

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

How To Sell A Talan

PHOENIX CONTACT - 03/2007

Product Information Sheet UH36 Hi Pot Tester

Modular I/O System Analog and Digital Interface Modules

MicroNet dual band IMSI and IMEI catcher

MCOM VEHICLE TRACKING SYSTEM MANUAL

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

BARCODE TICKET SOLUTION RF CARD SOLUTION MAGNETIC TICKET SOLUTION

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

SPL 2-00/-01 OPERATION INSTRUCTIONS

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

MCOM VEHICLE TRACKING SYSTEM MANUAL

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Key. ➍ Micro USB Port ➎ Operating System Toggle Keys ➏ Foam Screen Protectors. ➊ On/Off switch ➋ Bluetooth Connect Button (flashes when searching)

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Page 1 / 14 Groupe MOBILITECHMIOSBOX Technical Specification MWP-DT1010. Technical specifications

Agilent 87421A/87422A Power Supply

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS. 1. Features. 2. Description

Product Specifications

Changers Kalhuohfummi User Manual

GSM Voice Auto Dialer & SMS Sender JC-999

Transcription:

Driver Feedback Sign Model Product Information March 2007 3M Driver Feedback Signs (DFS) are effective speed calming tools for traffic authorities. The new model offers a state-of-the-art LED display technology for informing drivers about their vehicle s speed and/or reminding them of the given speed limit. Vehicle speeds measured by the built in microwave radar are displayed to drivers and logged for analysis of average and 85 th percentile speeds, speed trends by time of day, etc. Driver feedback signs are often used on road where compliance with the posted speed limit is essential for traffic safety. Example locations are: Areas where Speeds change Residential areas Work zones City entrances / Village gateways Accident Sites Dangerous curves Bridges Tunnels Vulnerable Road User Areas Hospitals School vicinities Near retirement homes Factory premises Bus stops University grounds Product Features Multiple Operating Modes Radar Mode displays real-time speed information Speed Limit Mode displays the posted speed Covert Mode measures speed but does not display to drivers Demo Mode for demonstrations and testing of display colour, brightness, and flashing LED Display Display can flashing for additional warning Display is legible to drivers from 100 metres 13-segment LED digits provide better readability than more commonly used 7 segment LED displays Photocell controls the brightness of the display to match ambient light conditions

User Defined Range Settings Limit the highest speed displayed to prevent intentional speeding at the DFS Limit lowest shown speed so that pedestrians runners and bicycles are not detected High Visibility Signface 3M Diamond Grade Reflective Sheeting on the surround increases sign visibility in all weather conditions and at night Multiple Power Options Operate with mains power using power supply unit, e.g. for fixed installations Operate with one or two optional 12 volt, 17Ah batteries for temporary applications Operate with battery buffered mains power using optional charger in locations with part time mains power Operate with optional solar panel and batteries for semi-permanent installations Multiple Communication Options USB cable links unit directly with local PC Bluetooth wireless link to PC or PDA Optional modem for long distance wireless data connection from the office (data SIM card supplied free of charge by 3M) Text Message Notification (when equipped with a modem) Sends a text when battery voltage is low Sends a text when memory is almost full or full and old data about to be overwritten Sends a text when diagnostic check identifies a fault Diagnostic Functions Diagnostic check verifies data memory integrity, supply voltage, radar operation, modem communication, Bluetooth communication etc. A self diagnostic check at startup, at midnight or on user demand Status of component Speed Data Analysis Easy downloading and speed data analysis Identify traffic volume and speed at a location Create tables and charts with just a few mouse clicks Produce before & after studies to evaluate what effect the DFS has on speed Day and Time Scheduling Set on/off time schedules by day of the week Tailor on times to coincide with periods of activity e.g. at school times, lunchtime pedestrian surges Prevent habituation of drivers Extend battery life User friendly Design Lightweight design sign can be installed by one person User friendly software interface Mounting box adapts to a range of post diameters (60 140 mm) Lockable mounting box provides vandal resistance for sign and accessories (modem, batteries, etc) High Quality Standard Trust in highest reliability Closed design ensures protection against humidity and dust (IP54) Self diagnostic functions allow quick verification of operability Text message notification (when used with modem) to inform of service needs Sign sets on hinge pins which makes it easy to install. When unlocked the sign swings open for service Included Components The is delivered as plug-and-play device including built in radar, a mounting box, software, and cables to directly operate and install it.

Components Supplied as standard Optional Accessories Additional accessories can be purchased separately to suit the specific needs of the customer and the application. CD with PC and PDA software and installation and user manual. Also a USB cable and a Bluetooth stick for PC USB port 12 Volt 17 Ah lead-gel battery with cable and polarity protected connector. Up to two such batteries can be connected to a DFS 700 Battery charger for recharging batteries from the mains supply or when DFS is installed where only part time power is supplied Power supply unit for converting 240 Volt AC mains power to 12 Volt DC GSM/GPRS modem for remote communication over 900 and 1800 MHz GSM networks Lockable mounting box which provides a secure area for batteries, modem. Adapts to post diameters of 60 to 140 mm 80 Watt or 125 Watt solar panel for semipermanent installations. A charge controller and bracket are also required. The 80 Watt panel should provide an 80% uptime subject to traffic density, optimum positioning and the number of batteries utilised. The 125 Watt panel should provide 90%+ uptime

Technical Data Dimensions & Weight 660 770 110 mm (w h d), 8.5 kg Operating Voltage 11.3 V 15.0 V Current (Power) Standby 0.02 A (0.24W) Radar mode w/o traffic (display inactive) 0.08 A (0.96 W) Radar mode with traffic (display active, one colour @med brightness) 1.00 A (12 W) Peak current (less than 1 second with all components on) 5 A (60 W) Power Supply Unit Input 100 V 240 V AC @ 50 60 Hz Protection class 1 Output 12 V / 100 W IP 55, ca. 2 kg Battery Standby Time Approx. 850 hours using one completely charged 12 Volt 17 Ah battery Fuse ATO Fuse 4A T Cabinet Rating IP 54 Cabinet Color 7042 RAL Sign Face White Diamond Grade reflective sheeting Printable area 530 290 mm (w h) Operating Temperature Range 35 to + 75 C ( internal temp.) Humidity Range Up to 95 % Display 330 mm high, 450 mm wide 2 ½-digits (speed up to 199), 13 segments LEDs InGaAIP SMD LEDs, viewing angle 16 18 3 rows green (570 nm), 3 rows red (635 nm) Backup Battery Lithium 3V CR2450, ca. 2 years lifetime Data Memory 1 MB non-volatile flash memory 100,000 data entries Radar Frequency 24.15 GHz 24.25 GHz Radar Power 20 dbm, 100 mw e.i.r.p. Radar Speed Range and Accuracy Measures from 2 mph to 120 mph (can be limited) ± 1.2 mph for speeds below 60 mph ± 2 % for speeds above 60 mph Radar Detection Range Approximately 100metres for average saloon car Radar Beam Width 14 horizontal, 24 vertical Bluetooth Class 2 module, 4dBm transmission power, up to 20 m range Interfaces USB, Bluetooth, Charger input, Battery 1 input (charges when battery charger connected), Battery 2 input, Power switch, RS- 232 (for modem), modem power supply, Switchgear for ext. devices, Grounding bolt Switchgear 24 VAC / DC, 150 ma, connector type Weidmüller BLZF 3.5/3/F SNOR Firmware Flashable Software DFS-CAS for Windows 2000/XP PC DFS-CAS for Windows Mobile 5.0 PDA Mounting Box / Battery Box For 60 to 140 mm pole diameters, ca. 7.5 kg GSM Modem* Wavecom 900 MHz / 1800 MHz (SIM card with Circuit Switched Data Services provided with modem), ca. 0.25 kg Batteries* 12 V, 17 Ah, ca. 6kg Battery Charger* 100 V 240 V AC @ 50 60 Hz Protection class 2 Max output 12 V / 60 W Temperature range - 40 to +40 IP 67, ca. 1kg * Optional accessories

EU Standards Compliance Device Radar Unit DFS Bluetooth Module GSM Modem* Standard (Directive / Council Recommendation) EN 50293 (89/336/EEC EMC Directive) Electromagnetic compatibility - Road traffic signal systems - Product standard EN 300 440-2 (99/5/EC R&TTE Directive) Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range devices; Radio equipment to be used in the 1 GHz to 40 GHz frequency range; Part 2:Harmonized EN under article 3.2 of the R&TTE Directive EN 60950 / EN 60215 (73/23/EEC Low Voltage Directive) Safety of information technology equipment including electrical business equipment / Safety requirements for radio transmitting equipment EN 301 489-3 (99/5/EC R&TTE Directive) Electromagnetic compatibility and Radio spectrum Matters (ERM): Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies between 9 khz and 40 GHz EN 50392 (99/519/EC EMF Recommendation) Generic standard to demonstrate the compliance of electronic and electrical apparatus with the basic restrictions related to human exposure to electromagnetic fields (0 Hz - 300 GHz) EN 301 489-17 (99/5/EC R&TTE Directive) Electromagnetic compatibility and Radio spectrum Matters (ERM): Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 17: Specific conditions for 2.4 GHz wideband transmission systems and 5 GHz high performance RLAN equipment EN 300 328 (99/5/EC R&TTE Directive) Electromagnetic compatibility and Radio spectrum Matters (ERM); Wideband Transmission systems; Data transmission equipment operating in the 2.4 GHz ISM band and using spread spectrum modulation techniques; Harmonized EN covering essential requirements under article 3.2 of R&TTE Directive EN 50392 (99/519/EC EMF Recommendation) Generic standard to demonstrate the compliance of electronic and electrical apparatus with the basic restrictions related to human exposure to electromagnetic fields (0 Hz - 300 GHz) EN 301 489-7 (99/5/EC R&TTE Directive) Electromagnetic compatibility and Radio spectrum Matters (ERM): Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 7: Specific conditions for mobile and portable radio and ancillary equipment of digital cellular radio telecommunications systems (GSM and DCS) EN 301 511 (99/5/EC R&TTE Directive) Global System for Mobile communications (GSM); Harmonized standard for mobile stations in the GSM 900 and DCS 1800 bands covering essential requirements under article 3.2 of the R&TTE directive (1999/5/EC) EN 50392 (99/519/EC EMF Recommendation) Generic standard to demonstrate the compliance of electronic and electrical apparatus with the basic restrictions related to human exposure to electromagnetic fields (0 Hz - 300 GHz)

99/5/EC R&TTE Directive Directive of 9 March 1999 of the European Parliament and of the Council on Radio Equipment and Telecommunications Terminal Equipment and the mutual recognition of their conformity 89/336/EEC EMC Directive Council Directive of 3 May 1989 on the approximation of the laws of the Member States relating to electromagnetic compatibility 73/23/EEC Low Voltage Directive Council Directive of 19 February 1973 on the harmonization of the laws of Member States relating to Electrical Equipment designed for use within certain voltage limits 99/519/EC EMF Recommendation Council Recommendation of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300GHz) 3M UNITED KINGDOM PLC 3M Centre Cain Road Bracknell Berkshire RG12 8HT Tel: 01344 857950 www.3m.com/uk/traffic Copyright 3M 2007