Not Only Heating and Cooling Hot Water as Well!!

Similar documents
Glossary of Heating, Ventilation and Air Conditioning Terms

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

National Grid Small Business Energy Efficiency Program Overview. Central New York Energy Expo March 30, 2010

Heating & Cooling Efficiency

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Geothermal Comfort Systems

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

Defining Quality. Building Comfort. Precision. Air Conditioning

Achieving ENERGY EFFICIENCY with Standard Air-Conditioning Units. Mike West, PhD, PE Advantek Consulting, Inc

Energy Efficiency. Energy Efficient Home Cooling:

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%

The ASHRAE HQ Building Can the energy efficiency of the different mechanical systems really be compared? RESIDENTIAL LIGHT COMMERCIAL COMMERCIAL


GEOTHERMAL HEATING AND COOLING INTRODUCTION

The main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.

QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM

Ground Source Heat Pumps The Fundamentals. Southington, Connecticut John F. Sima III P.E.

INSTALLATION AND OPERATION MANUAL

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

How To Get An Energy Star For A Small Duct High Velocity (Sdhv)

Commercial Refrigeration Temperature and Defrost Controls

Economic Evaluation of Residential Air Conditioner Designs for Hot and Dry Climates

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

HVAC Efficiency Definitions

The formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08

Engineering White Paper UTILIZING ECONOMIZERS EFFECTIVELY IN THE DATA CENTER

Customized Assessment Blueprint

HVAC Basic Science - System Capacity

HIGH EFFICIENCY RTU. HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

Lesson 36 Selection Of Air Conditioning Systems

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

HVACPowDen.xls An Easy-to-Use Tool for Recognizing Energy Efficient Buildings and HVAC Systems

Dehumidifier D 850E. - Instruction manual version 02

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

Air-Conditioning Buying Guide

RESEARCH HIGHLIGHT. Performance Assessment of a Cold-Climate Air Source Heat Pump

Creating Efficient HVAC Systems

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

How To Buy A Lennox Power System

EnergyPro Building Energy Analysis. Assisted Living Building

Evaporative Cooling System for Aquacultural Production 1

Innovent LASER Packaged Fresh Air Conditioning Units

Lower Energy Costs with Rooftop Air-Conditioning Package Units

All the best brands all under one roof

The Benefits Really Add Up

Impacts of Refrigerant Charge on Air Conditioner and Heat Pump Performance

USER S MANUAL HSC-24A

Case Study -Sandy Grove Middle School First Net Positive Energy P3 School In North Carolina

Hybrid (Dual Fuel) - Gas Heat and Air Source Heat Pump

Introduction. Motor Types

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

Get the FACTS about SEER and Deliver Better Customer Value

Centrifugal Fans and Pumps are sized to meet the maximum

forair optimal air environments ResidentialPresentation

The efficient heat pump

How To Improve Energy Efficiency Through Raising Inlet Temperatures

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

General Information. Do programmable thermostats really save energy?

Regency TAFE, SA. An evaluation of the effects of PermaFrost treatment on a Fujitsu Heat Pump. July Prepared by

The Different Types of Air Conditioning Equipment for IT Environments

Residential HVAC Load Sizing Training October 14, David Kaiser Green Code Plan Reviewer

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

Home Energy Evaluation Report

APPLICATION GUIDE. Comparison of Latent Cooling Performance of Various HVAC systems in a Classroom Application

Bring the fresh in. Dedicated Outside Air Systems

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

ICE AIR. Console Water Source Heat Pump (WSHP) OPERATING & MAINTENANCE MANUAL. Wo r l d C l a s s C o m f o r t.

Energy Efficiency HOSPITALITY.

COMMERCIAL HVAC EQUIPMENT. Condensers and Cooling Towers

Air Conditioning 101. STN Presentation AC101

February 1, Performance Tested Comfort Systems Air Source Heating Pump Installation Commissioning Procedure

Single Zone LCD Thermostat Operating Instructions

Transmission System Total Cost of Ownership

CHAPTER 9: WATER HEATING

EFFECTS OF INDOOR RELATIVE HUMIDITY ON REFRIGERATED DISPLAY CASE PERFORMANCE

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

, User s Manual

Pool Dehumidification Basics

Power Proportional Distribution (PPD)

Nordic Heat Pump Product Guide

J O U R N A L. Energy Performance for. Proper Specification of Air Terminal Units Future Climate Impacts on Building Design

Presented By: WALTER E. JOHNSTON, PE CEM, CEA, CLEP, CDSM, CPE

Poor Performing AC? High Electric Bills? High Humidity?

ECM Motors Manufactured By Regal Beloit. Products and Applications- What s an ECM? GEXPRO Regal Beloit s distribution arm for all ECM motor products

ZUBA-CENTRALTM. Heating & Cooling. Evolved. HEATING AND AIR CONDITIONING FOR WHOLE-HOME, YEAR-ROUND COMFORT

Geothermal Heat Pump Systems

Engineering Specifications

A NEW DESICCANT EVAPORATIVE COOLING CYCLE FOR SOLAR AIR CONDITIONING AND HOT WATER HEATING

Energy Efficiency Analysis for a Multi-Story Commercial Office Building. (LG Multi V III Heat Recovery VRF System)

Features and Benefits. Product Overview. Installation Overview. Sales Strategy Overview FPO

Characteristics of Evaporators

How Ground/Water Source Heat Pumps Work

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

How To Design A Building In New Delhi

Data Center Energy Use, Metrics and Rating Systems

THE CASE FOR A REFRIGERATION PREVENTATIVE MAINTENACE PROGRAM

Transcription:

WHY HYDRO-TEMP? Hydro-Temp geothermal/water source systems use load matching technology to provide all your heating/cooling and hot water demands at a fraction of the cost versus other leading geothermal systems. The load matching technology uses either dual compressors or a single variable speed compressor to change capacity outputs for the ever changing heating and cooling demands of your facility. The unit will run on low speed when conditions require only a minimal amount of heating or cooling. With increased demand, the Hydro-Temp system will automatically increase speed to satisfy the demand. Simply put, Hydro-Temp systems significantly reduce power consumption because they will only operate at the highest capacity as determined from the demand of the space being conditioned.

Not Only Heating and Cooling Hot Water as Well!! Hydro-Temp systems can efficiently meet your building s hot water needs by employing one of two different options available to the owner: -Desuperheater: While heating and cooling, the desuperheater will assist your hot water tank in making hot water for free in the summer and at a very low cost in the winter. Even if a desuperheater cannot keep up with the usage, it can assist the hot water tank in efficiently heating the water. -Priority Hot Water: The priority hot water heating option is a patented system that works like a desuperheater except that, once the heating or cooling load from the building is satisfied, the units microprocessor can turn on the system just to heat hot water when required. The temperature of the hot water tank is monitored by a digital aqua stat. When the room thermostat later calls for more heating or cooling, the unit will then switch back and heat or cool the building.

What Makes Hydro-Temp Even More Unique? MICROPROCESSOR CONTROL BOARD The Hydro-Temp microprocessor control board provides all of the control functions for Hydro-Temp systems. Besides controlling the unit in the normal operations of a dual compressor system, priority hot water control and zoning, the microprocessor board provides an easy trouble shooting interface for the service technician. The service technician has the ability to take control of the unit in heat and cooling, selecting individual stages as well as over riding time delays. The onboard LED s provide a history of any faults. Zone Control Zone control, or dampering of zones, is also accomplished by the microprocessor board. Each zone damper and thermostat hooks to the control board that will open and close the proper damper and turn the unit on and off. The control board allows one thermostat to call for heat while another calls for cooling. The heating zone will function first while the cooling zone shuts off until the heating zone has been satisfied.

Hydro-Temp Design Features Custom designed for each application Hydro-Temp designs and builds each unit for the specific application. Consideration is given to the operating and physical requirements for each location. All Hydro-Temp units are designed to operate efficiently with entering water temperatures between 25 F and 110 F. Hydro-Temp offers a complete range of models, sizes and voltages for all applications, horizontal or vertical, upflow or counter flow suitable for mounting in closets, overhead spaces, outside pad mounting and rooftop locations. Variable speed blower motor technology offers the capability to fine-tune the blower to unique local situations in ducting and/or CFM requirements

Past Projects Plano Elementary, Bowling Green, KY First year tests proved that the HYDRO-TEMP dual compressor heat pumps operated in the first stage 87% of the time. A 3.5 ton unit was field tested to determine the efficiency improvements. The heat pump unit consisted of a 1.5 ton and 2.0 ton compressor connected to a single 3.5 ton refrigerant circuit. Stage one efficiency is significantly higher than full load condition because the 1.5 ton compressor has 3.5 tons of Evaporator and condenser coil surface area for heat exchange. A field test measured the condenser and evaporator pressures/ temperatures and found that when both compressors operate, the 1.5 ton compressor has an energy efficiency ratio rating of 11. The compressor efficiency increases to 18 when running solely in the first stage. This results in a 64% efficiency boost when the dual compressor heat pump unit operates in stage one.

Past Projects Fayette High School, Fayette, MO The electrical consumption of the HYDRO-TEMP Corner Console heating and cooling equipment, as well as the generation of hot water for the kitchen, was sub metered by Howard Electric Coop from 8/28/02 to 5/30/03. Results proved that the 36,080 square foot school only consumed 61,400 kwh. Cost per kwh $0.06 $3,684.00 $0.07 $4,298.00 $0.08 $4,912.00 $0.09 $5,526.00 $0.10 $6,140.00 Annual Heating/Cooling Cost (36,080 ft 2 )

Past Projects Marion Junior High, Marion, AR The 194,082 square foot Marion Junior High was able to achieve 24 KBTU/Sq Ft by using HYDRO-TEMP heat pumps along with other energy conservation measures. The average energy nationwide for schools is about 73 kbtus per square foot. Electric Consumption Natural Gas Consumption Month kwh BTU CCF BTU January 128800 439,465,600 163 16,805,300 February 110400 376,684,800 199 20,516,900 March 92800 316,633,600 199 20,516,900 April 84400 287,972,800 154 15,877,400 May 95200 324,822,400 208 21,444,800 June 106800 364,401,600 171 17,630,100 July 86000 293,432,000 35 3,608,500 August 128000 436,736,000 20 2,062,000 September 166000 566,392,000 150 15,465,000 October 92400 315,268,800 194 20,001,400 November 95600 326,187,200 193 19,898,300 December 110800 378,049,600 208 21,444,800 Total 1297200 4,426,046,400 1894 195,271,400 SUMMARY Electric KBTU 23 Gas KBTU 1 Total KBTU 24

V-STAR Multiple Capacity System The newest addition to the Hydro-Temp line is the multiple capacity V-Star system. This system utilizes a variable speed compressor and variable speed ECM fan motor to provide the desired amount of heating and cooling. The actual capacity output of the system is based on the discharge temperature. Currently the system is available in the following capacities: 2 ton unit 6,000btu to 28,000btu 4 ton unit 13,000btu to 52,000btu 6 ton unit 24,000btu to 80,000btu

Watts 4500.00 Past Projects Commercial Office Building The graph below shows the results from a study comparing a 4-ton Hydro-Temp V- Star system versus a leading brand 4-ton system operating in the same environmental conditions over a 24 hour period. Energy consumption was reduced up to 46% 4000.00 3500.00 3000.00 2500.00 2000.00 1500.00 1000.00 500.00 0.00 Standard Water Source Heat Pump Hydro-Temp Water Source Heat Pump

Past Projects Continued Langley Air Force Base, Hampton, VA A recent study proved, even under unfavorable conditions, that the Hydro-Temp system achieved energy savings up to 40% while providing optimum indoor temperature and humidity versus other leading geothermal systems. The table below shows the results of a 24 hour period from a study that was conducted over several months. Leading National Brand 4 Ton WSHP Energy Data July 16, 2011 Outside Temp Minimum 64 Outside Humidity Minimum 42% Room Temp Minimum 72.89 Room Humidity Minimum 50.76% Outside Temp Maximum 80 Outside Humidity Maximum 92% Room Temp Maximum 74.09 Room Humidity Maximum 61.4% Outside Temp Average 71 Outside Humidity Average 73% Room Temp Average 73.4 Room Humidity Average 55.56% Total kw per 24 Hour Period 96.7 Average kw/hr 4.03

Past Projects Continued Langley Air Force Base, Hampton, VA A recent study proved, even under unfavorable conditions, that the Hydro-Temp system achieved energy savings up to 40% while providing optimum indoor temperature and humidity versus other leading geothermal systems. The table below shows the results of a 24 hour period from a study that was conducted over several months. Hydro-Temp 4 Ton WSHP Energy Data July 9, 2011 Outside Temp Minimum 71 Outside Humidity Minimum 60% Room Temp Minimum 73.58 Room Humidity Minimum 47.22% Outside Temp Maximum 83 Outside Humidity Maximum 100% Room Temp Maximum 74.96 Room Humidity Maximum 60.90% Outside Temp Average 77 Outside Humidity Average 89% Room Temp Average 74.3 Room Humidity Average 52% Average kw/hr Total kw per 24 Hour Period 58.4 2.44

Please contact PWA Engineering, LLC for additional information. Gene Henry Project Manager Email: genry@pwaengineering.com Address: 821 Juniper Crescent, Suite A Chesapeake, VA 23320 Office Phone: 757-366-5325 Fax: 757-366-5324 Website: www.pwaengineering.com