January 1, 2013. RE: TG-7FS Sole Path Cellular Alarm Communicator. To whom it may concern:



Similar documents
Alarm Systems Using Wireless or Other Transmission Technology as a Single Path of Communication. Purpose. References. Description of Code Reference

CAN/ULC-S Installation and Services for Fire Signal Receiving Centres and Systems- Ottawa 2013

Teldat Security IP & Wireless GSM/GPRS Alarm Communicators

AlarmNet Network Overview

SECTION DETECTION AND ALARM

Fire Prevention Coffee Break Training. November 2015

Central Station Interface with Fire Alarm and the Relevant Codes & Standards

The Evolution of Requirements for Supervising Station Alarm Systems

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

From Tyco Security Products. Commercial Fire Monitoring Solutions. Dsc -- The Most Trusted Name In Fire Monitoring

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT

New UL 864 & NFPA th Edition Fire Alarm Control Panel (FACP) AND. Cellular Communication Regulation Advancements

Fire Alarm System Monitoring - CAN/ULC-S561-03

Wireless Mesh Networks and Applications in the Alarm Industry. A Technology Overview. Presented by

Common Questions & Answers

Loop Start or Ground Start?

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

Elvey is a leading distributor of electronic security equipment in Africa. Our vision is to assist in the protection of people and property by

Simon XTi Installation Guide

OBOA 2009 Huntsville, ON Overview of ULC Standards Affecting Building Occupancy Alan Cavers Area Manager Fire & Security Systems Group

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

Comprehensive Security with one Powerful System. G Series integrated security, fire and access control panels

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

White Paper. Why Cellular as a Single Transmission Path meets the Requirements of NFPA 72. The Gradual Demise of POTS

Attachment 9. Trouble signals. Interfaced equipment. Primary (main) power supply

UL s Perspective on IP Signaling Larry Shudak Principal Engineer Signaling and Security Control Equipment Underwriters Laboratories Inc.

NATIONAL FIRE ALARM AND SIGNALING CODE

INTRUSION DETECTION SYSTEM Section

FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011

FIRE SPRINKLER SYSTEM SUPERVISORY SERVICE User s Guide (DamarNet RAR Service)

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

FVSU REPAIR & UPGRADE FIBER OPTIC SECTION FIRE ALARM SYSTEM CONNECTIVITY

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

Control Panels D9412GV3/D7412GV3/D7212GV3. UL Installation Instructions

Commander 2000 Control Panel

Module 4, Lesson 12 Fire Alarm Systems

ARCHITECT AND ENGINEER SPECIFICATION SECTION DETECTION AND ALARM SECURITY ACCESS AND SURVEILLANCE. DSC MAXSYS PC4020 V3.

HERNANDO COUNTY FIRE ALARM GUIDELINES

ERS-2400B. PERS-2400B Personal Emergency Reporting System

FIRE ALARM SYSTEM RECORD OF COMPLETION

United Security Products Automatic Dialers are a NEW BREED of Security

The Pennsylvania State University Physical Security Office. Intrusion Alarm. Performance Specification

FIRE ALARM SYSTEM RECORD OF COMPLETION

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

Rev E October 2004 ZZZ*(6HFXULW\FRP. Part No: R. CareGard. User Guide

UL Fire Door Inspection Service. UL Fire Alarm Certification Program. A valuable but misunderstood resource for jurisdictions

v 1.42b Conceal-Alarm Information Packet for Fire Alarm System Contractors & Installers Conceal -Alarm

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

CONTRACT MONITORING SERVICES NEW DEALER INFORMATION AND PROCEDURES

D9412GV3/D7412GV3. Approved Applications Compliance Guide. Control Panels

AlarmNet-i. Are you ready for Internet monitoring?

Model 70A00-1. GSM Cellular Communications Center

Fire Pump Controllers Remote Alarm Panels

What Should I Expect From My Alarm Monitoring Station?

Article 3. ALARM SYSTEMS. (08-08)

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

Invitation to Bid FIRE ALARM & DETECTION SYSTEM

Fire Alarm System Plans Review Checklist Property location Date of Review

NETWORK TECHNOLOGY. Long Range Radio Networks

PERS-3600B PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

ARTICLE 735. Emergency Alarm System

Finance and Administration Department 907 Billy Mitchell Blvd. P: (210) Fire Alarm Permit Application

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors

Fire Alarm System Monitoring, a Primer for the Property Owner David Duggan, 2005

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

SILENT KNIGHT MODEL 5207

How To Install A Carbon Monoxide Detector

Original Document 10/16/07 Revised 01/30/09 2 nd Revision rd Revision- 12/18/14

Understanding Fire Alarm Requirements & Inspections. Presented By Bill Conroy Technical Sales For Briscoe Protective Systems Inc

SECTION FIRE ALARM AND DETECTION SYSTEM

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

PLAN REVIEW GUIDE FOR FIRE ALARM

FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January 2014

INTEGRATED SECURITY SYSTEM PERFORMANCE SPECIFICATION FOR DMP MODEL XT SERIES CONTROL PANELS

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Fire Alarm FAQs. Q: How many zone/circuit fire alarm panel do I need? Q: What candela strobes do I need?

Before the FEDERAL COMMUNICATIONS COMMISSION Washington, DC 20554

PowerCode Wireless. Fully supervised wireless system. Features

NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet

TESTING, INSPECTION, AND MAINTENANCE FREQUENCIES FOR FIRE DETECTION AND ALARM SYSTEMS

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

PURPOSE AND GENERAL POLICY DEFINITIONS ALARM PERMITS (1) Permit Fees

AC-115 Compact Networked Single Door Controller. Installation and User Manual

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

AETNA FIRE ALARM SERVICE CO., INC.

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE

UNIFIED FACILITIES GUIDE SPECIFICATIONS

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual

WIRELESS INSTRUMENTATION TECHNOLOGY

APPLICATION SUPPORT BULLETIN

CHANGES IN NFPA 72 NATIONAL FIRE ALARM CODE

COMBINE BURGLARY AND FIRE PROTECTION WITH ACCESS CONTROL IN A SINGLE,

PC4020CF v3.0 and higher Commercial Fire Installation Guide DLS-3 v1.3

Transcription:

January 1, 2013 RE: TG-7FS Sole Path Cellular Alarm Communicator To whom it may concern: In November 2009, the National Fire Protection Association (NFPA) released the newest addition to the NFPA 72, National Fire Alarm and Signaling Code, 2010 Edition. This addition contained numerous code updates, but one in particular affected Telular's Telguard product line. The new code defined a set of general communication guidelines which, if adhered to, would allow new communications technologies to act as the sole path for fire control panel communications. Cellular was one such technology. Now at the beginning of 2013, the NFPA has approved their 2013 edition of the code. With a further, favorable revision of the sole-path clauses, this edition allows a less aggressive supervision rate for cellular installations. The updated code outlines in its main body and appendix the requirements products must meet to operate as a sole path (i.e., no redundant path) of communications. Essentially, two requirements are introduced: 1. The communications path must be supervised once every sixty minutes and annunciated at the supervising station within five minutes of any failure, and 2. The battery backup must provide 24 hours of standby current plus five minutes of signaling current while operating at the sixty minute supervision interval. In December 2010, Telular launched the TG-7FS Sole Path Cellular Alarm Communicator. Prior to its release, it was subjected to stringent tests by UL following the UL 864 Rev. 9 test suite. This revision was developed to test the newest NFPA 72 code and specifically verifies the strict 2010 edition requirements (five minute supervision). With the updated code, Telular has recertified the TG-7FS against the new 2013 edition and its sixty minute supervision requirement. Please refer to the attached documents for more details on the features of the TG-7FS, certification letters from testing authorities, and a reference guide to the NFPA code sections that allow the Telular Telguard TG-7FS to be a sole path for fire control panels. Sincerely, Shawn Welsh Vice President Telular Corporation Telular Corporation 3225 Cumberland Blvd Suite 300 Atlanta, GA 30339 MAIN: (678) 945-7770 FAX: (678) 945-7758 www.telular.com

CELLULAR GUIDE TO THE NFPA 72 2013 EDITION NFPA 72 2013 Edition contains language in key sections that allow cellular based products to be used as the sole path of communications for fire control panels. It specifically defined a section for performance-based technolgies. The specific requirements for performance-based technologies are detailed in a table in the code s Annex. UL 864 Rev. 9 has been written to specifically test products to the NFPA 72 2013 Edition code. The Telguard TG-7FS is UL 864 Rev. 9 listed and found fully compliant with NFPA standards. TELGUARD TG-7FS NETWORK DIAGRAM Code Section Section Summary Telguard s Compliant Component 26.6.3 This section defines communication methods Radio and One-Way Private Radio. Equipment that meets the performance requirements of this section are permitted as suitable communications methods. 26.6.1 This section covers all communications methods between the premises and the supervising station. It directs the reader to Table A.26.6.1. Table A.26.6.1 This table defines that annunciations on the degradation and restoral of a communications path must occur within sixty (60) minutes. It also defines the fact that equipment conforming to 26.6.3 must only provide a redundant path if the communications failure cannot be annunciated within sixty (60) minutes. Telguard 3225 CUMBERLAND BLVD SE STE 300 ATLANTA GA 30339 800-229-232

TG-7FS Cellular ALARM Communicator for 3g/4g networks Commercial Fire PRODUCT FEATURES Meets UL 864 requirements for sole, primary or backup path communications. Provides RMR protection by leveraging technology that operates on 3G/4G networks. Supports listen-in, two-way voice verification over cellular. Minimizes false alarms by providing dual paths for self-tests. Falls back to 2G (GSM) if a 3G/4G network isn t available. The Telguard TG-7FS is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2013 Edition of NFPA 72, the TG-7FS can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS because of the new sixty minute supervision mode. The TG-7FS can also be installed as a backup path and upgraded to sole path at a later date. Telguard Online Telguard Cellular Service Advanced Reliability Telguard makes adopting cellular easy with a secure Internet portal. The straightforward web interface allows security dealers and central stations to quickly and efficiently access Telguard based services 24/7. This advanced tool has multi-level user authorization and provides total account management of UL Listed Telguard cellular alarm communicators. Telguard Cellular Service provides nationwide digital cellular network coverage for all Telguard units. Telguard s Communication Center is UL compliant and provides seamless connectivity between the alarm panel, the Telguard family of products and the central station. Telguard Technical Support provides a single point of contact for both cellular service and Telguard product questions. Features the ability to utilize multiple cellular technologies to increase availability and reduce false alarms. Automatic self-tests with central station notification ensure the cellular system is operating. Available relay output for tripping the alarm control panel when a trouble condition occurs.

TG-7FS Cellular ALARM Communicator for 3g/4g networks Power Transmit power: 1.0W-2.0W (maximum allowable). Power Consumption: 60mA (Standby) 250mA (Transmission). Transformer: 12VAC, 800mA UL listed plug-in. Radio Transceiver 3G cellular radio. GSM 850MHz: Class 4 (2 watts). GSM 1900MHz: Class 1 (1 watt). UMTS WCDMA FDD 850/1900MHz. Antenna: 9 dipole with 2dBi gain, 12 ft of cable and universal mounting bracket. FCC part 15, 22, 24 and 68 compliant. Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. HGD-0: High gain directional antenna. EXD-0: External antenna. Physical Details TG-7FS: 7.5 H x 11.5 W x 3.5 D. Shipping Weight: 8lbs. Operating Environment: 0 C to +50 C; up to 95% humidity (non-condensing). Standard Features Full data reporting. Automatic self-test (60 min. & daily). Power supply with battery harness. Locking, red metal enclosure. Two programmable supervisory trip outputs. Alarm format support for SIA2, Contact ID, pulse (3x1, 4x2), modem IIe, & IIIa 2, DMP. Telephone line monitor built-in, with Standard Line Security. UL Listings Commercial Fire 864 Control units & accessories for fire alarm systems Commercial Burglary 365 Police Station connected burglar alarm units and systems 1610 Central station burglar alarm units; Line security servcies * For the most current product specifications and UL Listings visit www.telguard.com. Residential 985 Household fire warning systems Telguard, a Division of Telular Corporation Cumberland Center IV 3225 Cumberland Blvd Suite 300 Atlanta, GA 30339 USA 800-229-2326, Option 5 www.telguard.com Copyright 2012 Telular Corporation All Rights Reserved 122012RevB

C E R T I F I C A T E O F C O M P L I A N C E Certificate Number 20120308 S50526A Report Reference S5052 2007 April 26 Issue Date 2010 March 08 Issued to: This is to certify that representative samples of TELULAR CORP 311 S WACKER DR SUITE 4300 CHICAGO, IL 60606 USA Control Unit Accessories, System, Control Units and Accessories, Household System Type, Central Station Alarm Units, Police-station-connected Alarm Units & Household Burglar Alarm System Units Fire Alarm and Security Equipment: Models, TG7G0004, TG7GA004 and TG7GFS04. All these models are suitable for Standard Line Security. Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: Additional Information: ANSI/UL 864, "Control Units and Accessories for Fire Alarm Systems," ANSI/UL 985, "Household Fire-Warning System Units," ANSI/UL 1610, "Central-Station Burglar-Alarm Units," ANSI/UL 1635, "Digital Alarm Communicator System Units," ANSI/UL 365, "Police Station Connected Burglar Alarm Units and Systems," ANSI/UL 464, "Audible Signal Appliances" and ANSI/UL 1023, "Household Burglar-Alarm System Units." See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Listing Mark should be considered as being covered by UL's Listing and Follow-Up Service. The UL Listing Mark generally includes the following elements: the symbol UL in a circle: with the word LISTED ; a control number (may be alphanumeric) assigned by UL; and the product category name (product identifier) as indicated in the appropriate UL Directory. Look for the UL Listing Mark on the product. William R. Carney, Director, North American Certification Programs UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at www.ul.com/contactus Page 1 of 1

CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0109 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP2727 Paces Ferry Rd., Suite 1-800, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju@telular.com DESIGN: INSTALLATION: MARKING: APPROVAL: NOTE: Models TG7G0004, TG7GFS04, and TG7GA004 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7G0004 and TG7GA004 are household apploication and Mode TG7GFS04 is for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as digital cellular radio alarm transmission devices to provide a primary transmission path (cellular) for connection to a listed compatible fire and burglar alarm control unit with integral digital alarm communicator transmitter (DACT). Refer to listee s Installation Instruction Manual for details. Burglary and other non-fire functions were not examined. 12-08-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee s data sheet, installation instructions and/or other Date Issued: December 12, 2011 Listing Expires June 30, 2012 Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division

03/22/2012 Rev 2.0

12/19/2012 Rev 3.0

12/19/2012 Rev 3.0

12/19/2012 Rev 3.0