A selection of Universal Socket-outlets See the following pages of this report for details

Similar documents
Intertek Research & Performance Testing Technical Report S64604 Issue 1 Page 1 of 17. Report issued by: S64604 Issue 1

Section B: Electricity

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

HOUSING QUALITY STANDARDS (HQS)

Electrical Safety Plugs What are the different types of plugs? Extension Cords What are some potential hazards involving extension cords?

Electrical Resistance Resistance (R)

Fire Protection Notice No. 9 ELECTRICAL SAFETY

INFRARED QUARTZ WALL HEATER

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

FIRST STOP SAFETY 1 PAT-IT. Portable Appliance Tester. User Manual. Issue 1.6

ELECTRICAL PRACTICES FOR CONSTRUCTION WORK

Safety & Environmental Protection Services Guidance Note

in the United States Home fires are a major problem Older Homes Pose an Even Greater Threat Put it into perspective: Electrocutions can be Prevented

GUIDE TO THE MAINTENANCE, INSPECTION AND TESTING OF PORTABLE EQUIPMENT (ELECTRICAL APPLIANCES AND TOOLS) IN THE WORKPLACE

Electrical Safety Tips. Help us keep you safe

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Electrical Grounding. Appendix C

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

4 IX D N E P P A Installation methods Current-carrying capacity and voltage drop for cables Reference method IET Wiring Matters

CHECKING AND TESTING ELECTRICAL INSTALLING WORK

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Electrical installation condition reporting:

Home Electrical Safety

User s Manual Before using the inverter, you need to read and save the safety instructions.

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/ circuit board

Electrical Practices for Construction Work

CompactLogix Power Supplies Specifications

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

Installation Instructions

Maintaining portable electric equipment in low-risk environments

The Different Types of AC Power Connectors in North America

Unit 4: Electricity (Part 2)

NEW ZEALAND ELECTRICAL CODE OF PRACTICE REPAIR AND MAINTENANCE OF DOMESTIC ELECTRICAL APPLIANCES BY THE OWNER OF THE APPLIANCE

Meaco 30L and Meaco 40L dehumidifier instruction manual

in the United States Home fires are a major problem Older Homes Pose an Even Greater Threat Put Into Perspective Electrocutions Can Be Prevented

Manual Ranging MultiMeter

Electrical Wiring Methods, Components and Equipment for General Use. Approved for Public Release; Further Dissemination Unlimited

Inspection and testing of portable electrical equipment

Drayton Digistat +2RF/+3RF

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE CONSTRUCTION SAFETY STANDARDS

SMD Rework Station TABLE OF CONTENTS

Electrical Receptacle Outlet Reverse Polarity & Open Ground

OPERATING INSTRUCTIONS

Portable Air Conditioner

TEST REPORT. Report nº: LABEL Date: Laboratório de Ensaios Eléctricos Page nº: 1/11

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23

IH E Sigma Island 90

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

The Different Types of AC Power Connectors in North America

AutoRanging Digital MultiMeter

12-Volt 10-Amp Regulated Power Supply

October Safety Subject

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

How To Keep An Eye On Electric Safety

How To Use A Power Supply On A Powerline 2.2 (Ai)

Extension Cord Safety Policy

DEVICES OF PROTECTION AND COMMAND

INSTALLATION & SERVICE MANUAL. Display Panel

A guide to understanding and maintaining your home s electrical system. A publication presented by the Electrical Safety Foundation International

Challenges to Ensure Safety of Electronic Equipment

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

ST Series POWER SUPPLIES USER INSTRUCTIONS

R.C.C.B. s two-pole LEXIC

AC-DC Converter Application Guidelines

3 IN 1 BATHROOM HEATER

PANEL CUT-OUT DIMENSIONS

IEC >>> IEC GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

ELECTRIC INSTANTANEOUS WATER HEATER

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

Model UT201/202: OPERATING MANUAL. Table of Contents

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

RY2 miniature industrial relays

MCR1900 Media Converter 19-Slot Chassis

7 Lighting Technology

Explosion proof enclosures

Ducoterra Radiant Heating Panel Installation Manual

BATHROOM HEATER. User's Manual. Page 2...A515 Page 9...A716

Online UPS. PowerWalker VFI 1000R/1U

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

Transformers from 25va to 500kva. Standard despatch in days not weeks

Oil and Coolant Circulating Heating System. Model - OCSM

RCD Inspection Log Book

Technicaldata General

UT202A Operating Manual. Contents

Your Guide to. Electrical Safety

ALUMINUM ELECTRICAL WIRING

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Generator Transfer Switch Model # HTS15-AUTO

chapter8 Testing and commissioning Unit 2 outcome 2

Model 1756 Test Lead Kit

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

6.0 Electrical Installations

Building Services Engineering Technician

Experts in what we do. Portable Appliance Testing A Practical Guide.

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Transcription:

TEST REPORT No. : 44188 Client Client Contact Item/s tested Tested to Electrical Safety Council Unit 331-3 Great Guildford Business Sq 30 Great Guildford Street London SE1 0HS Mr Steve Curtler A selection of Universal Socket-outlets See the following pages of this report for details Investigation looking at the safety implications of the installation of universal socket-outlets in the UK for domestic and commercial use, using reference standards BS 1363-2: 1995 +A4: 2012 & BS 5733: 2010 Date sample received 13 th September 2012 Test Period 1 st October to 9 th November 2012 Date of Issue 12 th November 2012 Tests carried out at 20 5 º C Testing Officer Giuseppe Capanna Verified by Bunmi Phillips Form No: QF102-5 Issue No: 2 Issue Date: 12.01.09 Page 1 of 10

THIS REPORT APPLIES ONLY TO THE PARTICULAR SAMPLE UNIT(S) TESTED AND TO THE SPECIFIC TESTS CARRIED OUT AS DETAILED IN THIS REPORT. Objective Investigation looking at the safety implications in foreseeable conditions of use where universal socketoutlets are installed in the UK for domestic and commercial use, using reference standards BS 1363-2: 1995 +A4: 2012 & BS 5733: 2010. This report will also assess the legal implications of installing these sockets against requirements of the UK Plugs and Sockets etc. (Safety) Regulations 1994 (SI 1768) and the Requirements for Electrical Installations BS 7671: 2008 (Amendment No 1: 2011). It should be noted that full testing to BS 1363-2: 1995 +A4: 2012 & BS 5733: 2010BS 5733 and other relevant standard(s) mentioned has not been carried out as part of this investigation. Compliance with The Plugs and Sockets etc. (Safety) Regulations 1994 (SI 1768) The Plugs and Sockets etc. (Safety) Regulations 1994 states: Electrical devices other than standard plugs 10. (1) Subject to the following provisions of this regulation, any electrical device (other than a standard plug) specified in column 2 of Schedule 2 to these Regulations shall conform to the particular British Standard specified for such devices in column 3 of that Schedule. Schedule 2 specifies that standard plugs i.e. BS 1363 plugs and socket-outlets with which standard plugs may be engaged shall comply with BS 1363. From a legal point of view it is clear from the above extracts that it is illegal to install any socket (with which standard BS 1363 plugs may be engaged) that do not comply with the requirements of BS1363. This point is further reinforced with guidance from the Requirements for Electrical Installations BS 7671: 2008 incl Amendment No 1: 2011 (Wiring Regulations 17 th Edition), which states in clauses 510 & 511 that: Every item of equipment shall be selected so as to allow compliance with the regulations and that every item of equipment shall comply with the relevant requirements of the applicable British or Harmonized standard, appropriate to the intended use of the equipment. Appendix 1 lists the applicable standard as BS1363 and further references to the use of BS 1363 shuttered socket-outlets can be found in regulation 553 in particular 553.1.100 and table 55.1. Compliance with BS 1363 is particularity important for safety in UK installations complying with BS7671 (Wiring regulations) in that sockets are traditionally installed in the UK in a final ring circuit configuration. A final ring circuit is generally protected by a 32A MCB or RCBO which adequately protects the 2.5mm 2 installation wiring and but relies on the fact that each individual appliance connected to the ring circuit is protected by its own fuse in the BS 1363 plug or fused connection unit. Without this protection, as would be the case if these universal socket-outlets were installed on a UK final ring circuit and used with any plugs other than BS1363 type, the only protection would be the 32A MCB, leading to the situation where the cord of an appliance such as a table lamp (typically 0.5mm 2 ) would have the 32A MCB as its only means of protection in an overload situation. This results in a significant risk of fire. Sample selection: Five types of universal socket-outlets were supplied for the investigation. 3 types of switched socket-outlets and 2 types of unswitched socket-outlets (see photos below). The samples will be identified in this report as samples 1-5 as below Page 2 of 10

Photographs of samples tested 1 2 3 4 Page 3 of 10

5 Results of tests and inspections Classification None of the samples complied with BS 1363-2. However the classification according to BS 1363-2 would be as follows: Single (samples 1, 2 & 5) Multiple (samples 3 & 4) Switched (samples 1,2 & 3) Single pole Double pole Unswitched (samples 4 & 5) Fused Unfused (all) Portable (sample 5 is a panel mounted socketoutlet for use in non-rewirable portable socket-outlets) Rewirable (samples 1,2,3 & 4) Non-rewirable (sample 5) Fixed (samples 1,2,3 & 4) Flush-mounted (samples 1,2,3 & 4) With indicator lamp (sample 3) Without indicator lamp (samples 1,2,4 & 5) Surface mounted Panel mounted (sample 5) Page 4 of 10

Marking, labeling and instructions Socket-outlets installed in the UK for domestic and commercial use with which standard (BS1363) plugs may be engaged shall comply with the requirements of BS 1363-2: 1995. All of the samples had marking failures to BS1363 to a greater or lesser extent (see table below). Required Marking / Sample Designation 1 2 3 4 5 a) Name, trademark or identification mark * b) BS 1363 c) /A for portable socket-outlets N/A N/A N/A N/A N/A d) L, N & for terminals e) FUSE or FUSED for fused socket-outlets N/A N/A N/A N/A N/A f) MAX 13A for multiple fused socke-outlets N/A N/A N/A N/A N/A g) 1) Rated current 2) Rated volts 3) Nature of supply = Marking complies = Marking does not comply N/A = Marking not applicable Note: the marking also failed to comply with the requirements of BS 5733 Instructions Only sample 2 was supplied with user instructions. The instructions did not warn users of the hazards associated with installing or using these sockets in the UK. Clearances, creepage distances and solid insulation The clearances, creepage distances and distances through solid insulation were found to be adequate on all 5 samples inspected Accessibility of live parts Samples 1, 2, 3 & 4 were all fitted with shutters. Although only sample 2 passed the test of clause 9.1 with the 1mm test pin of fig 1 of BS1363-2. Samples 1, 3, 4 & 5 all allowed access to live parts when the test pin was applied with a force of 5N. It was possible with all the samples tested to touch the live plug pins of a Schucko or US plug whilst inserting and removing these plugs from any of the socket-outlets. This represents a significant risk of electric shock to the user. (see photos below). On sample 3 & 5 it was also possible for a plug pin to be inserted whilst the other plug pin was accessible. Although for sample 5 this may be prevented if used in a suitable enclosure Page 5 of 10

Provision for earthing When used with UK, AS/NZS or US plugs the resistance between the earth terminal and the inserted plug pins was adequate. When used with plugs with side earthing contacts such as a Schucko plug or plugs with an earthing socket such as the French plug, the earth connection is lost resulting in a risk of electric shock in the event of a failure of basic insulation with class 1 appliances. Terminals and terminations A limited check was carried out on the terminals of the samples and each of the samples was able to accept 3 x 2.5mm 2 solid conductors. Construction All of the samples except for sample 5 were fitted with shutters. However only the shutters on sample 2 complied with the requirements for access to live parts (see accessibility of live parts above). The size and of the apertures on these universal socket-outlets are designed to accept as many different types of plugs as possible. As a result of this the apertures tend to be overly large and can lead to the incorrect insertion of certain plugs. In particular: (i) the Europlug can be inserted between the line and earth contacts on 4 out of 5 of the samples checked and (ii) these socket-outlet are designed to accept both the US 3 pin plug and the AS/NZS 3 pin plug. This results in the polarity of the US plug being reversed, which can result in a hazard in the case of class 1 appliances. Page 6 of 10

There is a further potential hazard with regard to the US plug and similar flat blades plugs in that the rated voltage of most appliances fitted with these plugs is 120V (USA and Canada), 127V (Mexico) and 100V (Japan). There is a risk that 100-120V appliances could be connected to a 240V supply resulting in a risk of fire. (see below for the results of tests carried out) The shape of sample 4 and the proximity of the two socket-outlets was such that simultaneous use of both sockets with BS 1363 plugs was not possible or a single BS 1363 plug and any other type of plug. The size of the cover plate on this sample was also such that it would not fit a standard BS4662 type box. Sample 3 was rated 13A. However this sample was fitted with a switch rated at only 10A. Insulation resistance and electric strength The insulation resistance and electric strength insulation were found to be adequate on all 5 samples tested Temperature rise The temperature rise on all 5 samples tested was found to be below the maximum limits required by the standard. Normal operation of socket-outlets IEC 60884-1 the international standard for plugs and socket-outlets and most international socket standards require 5000 insertions for socket-outlets. However, UK BS 1363 requires 15,000 insertions. The samples were first subjected to 5000 insertions. At the end of 5000 insertions the samples were inspected and all 5 of the samples were satisfactory. The samples were then subjected to a further 10,000 insertions in line with the requirements of BS1363. The results were as follows: Sample 1 Shutters broke after 10,000 insertions, test stopped. (See photo) Sample 2 Coverplate cracked after 10,000 insertions, test stopped. (See photo) Sample 3 Completed 15,000 insertions, shutters working, temperature rise within limits Sample 4 Completed 15,000 insertions, shutters working, temperature rise within limits Sample 5 Completed 15,000 insertions, no shutters, line contact was found to be broken. Sample 1 after 10,000 insertions Page 7 of 10

Sample 2 after 10,000 insertions Mechanical strength 10 blows were applied to the 5 samples as described in the standard, the height of fall being 150 0-5 mm. 0.53 Nm was applied to the fixing screws where appropriate. The results were as follows: Sample 1 No damage Sample 2 Cover plate cracked after 5 blows (see photo) Sample 3 Indicator lens displaced and minor displacement of the actuating member (see photo) Sample 4 No damage Sample 5 No damage Sample 2 after 5 blows Sample 3 after 10 blows Screws, current-carrying parts and connections The contacts of these sock-outlets relied to some extent on the enclosure for contact pressure. Further testing would be required to determine whether there is sufficient resilience in the metal parts to compensate for any yielding of the insulating materials. Page 8 of 10

Resistance to abnormal heat and fire Table of Glow-Wire test results Sample Part tested Colour Test Temp ( C) Pass Fail Front plate & shutter White/Black 650 Sample 1 Base moulding Black 850 Switch actuating member White 850 Front plate & shutter White 650 Sample 2 Base moulding Grey 850 Switch actuating member White 850 Front plate White/Black 650 Sample 3 Base moulding Black 850 Switch White/Black 850 Front plate White 650 Sample 4 Cover plates (2) White 850 Base moulding Black 850 Sample 5 Front plate Black 850 Base moulding Black 650 Sample 1 base @ 850 C Sample 1 switch actuating member @ 850 C Sample 3 switch actuating member @ 850 C Sample 4 Front plate @ 850 C Sample 4 Base @ 850 C Page 9 of 10

Connection of 100-120vac appliances to 240vac supply A selection of 100-120v appliances including an energy saving light bulb, a hair dryer, a fan heater, a kettle and a toaster were connected to the 240v supply and switched on to ascertain any potential hazards. Most of the appliances survived the test and either shut down safely or failed in a safe manner. However, the toaster elements became much hotter than they would in normal use and part of the plastic casing melted. The toaster did not catch fire but there is obviously an increased risk of fire when used at 240v and also an increased risk of burns. Photograph of 110v toaster after connection to 240v supply Conclusions and observations From the test results above it is clear that as well as the legal implications of installing these universal socketoutlets in the UK for domestic and commercial use, there are also serious potential hazards including risk of electrocution and risk of fire. Recommendations It is recommended that electricians are alerted to the potential hazards detailed in this report, in case they are requested to fit such socket-outlets in domestic or commercial installations (for example in hotels). ***************** END OF TEST REPORT ***************** Page 10 of 10