Home Performance with ENERGY STAR COMPREHENSIVE HOME ASSESSMENT DETAILS

Similar documents
Energy Upgrade California TM Incentive Reservation Form

energy-saving checklist a guide for rental property owners

BUILDING PERFORMANCE INSTITUTE TECHNICAL STANDARDS

Home Energy Evaluation Report

Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen

BPI Air Conditioning & Heat Pump Professional Training Sample Slides ( ) Agenda

First Time Home Buyers Energy Efficiency Workshop Guide

Contract for Weatherization Management Address City & State

Home Performance with ENERGY STAR. Evaluation Report

Attachment #23 Health Safety Table. Client Education Inform issue and document. How to clean & maintain gutters. How to adjust sprinklers

Center for Energy Education Laboratory

Category Measure Minimum Efficiency / Certification Requirements

Air Conditioning Systems DOE, DOE ARRA, LIHEAP WX, RMP. Heating Systems DOE, DOE ARRA, LIHEAP WX, LIHEAP Crisis, Questar

Proposed Amendment: Revisions to Chapter 8 Sections Proponent: RESNET Technical Committee

Before You Start an Energy Efficiency Retrofit The Building Envelope

ECHO System for Basements

Building Energy Codes 101 October 23, Matthew Giudice Building Policy Associate Midwest Energy Efficiency Alliance

Direct Energy Home Energy Audit Audit Report

BUILDING PERFORMANCE INSTITUTE TECHNICAL STANDARDS

Home Energy Auditing Standard

Amendment: Combustion Appliance Testing Standards Removal. Proponent: Brett Dillon, Chair Standards Development Committee

Training Course Catalog

Chapter Seven RESNET Standards

Energy Efficiency Evaluation Reportii House file number: 9900D00001ii

October 5, 2015 Dear Client,

BUILDING SAFETY UNIT

HVAC Code Requirements

Chapter Seven RESNET Standards

ANSI/BPI-1200-S-2015:

How to Live in a Better Building: Home Energy Evaluations and Energy Efficiency Upgrades

RESNET Interim Guidelines for Combustion Appliance Testing and Writing Work Scope September 1, 2010

Your Personal Home Energy Action Plan

Training course catalog

Sample DTE Energy Rebate Programs Follow:

Energy-saving tips for apartments and condos

SAVE ENERGY AT HOME INSULATE AND AIR SEAL

FLORIDA SOLAR ENERGY CENTER

INCORPORATION BY REFERENCE OF INTERNATIONAL. (1) The Department of Labor and Industry adopts and incorporates by

Analysis of 2009 International Energy Conservation Code Requirements for Residential Buildings in Kansas City, Missouri

HOME ENERGY AUDIT REPORT

ENERGY STAR Certified Homes, Version 3 Cost & Savings Estimates

REQUEST FOR PROPOSALS BUILDING ENVELOPE, LIGHTING, & HVAC TESTING/RESTORATION SERVICES

Home Energy Evaluation Report for House Three

Home Energy Auditing Standard

Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers

Home Management Checklist: Spring

Attic condensation during winter can

Key energy-efficient features of your new home

EPA WaterSense for New Homes Program DOE Zero Energy Ready Home Quality Management Guidelines

VILLAGE OF HUDSON FALLS 220 MAIN STREET HUDSON FALLS, NY (518) /

Energy Efficiency for the Homeowner

Chapter 2: Foundations

Town/City: State: Zip: Town/City: State: Zip: Phone: Cell: Phone: Cell: Signature Print Name Date

IECC Compliance Guide for Homes in Virginia

2014 British Columbia Building Code Changes

BGE Smart Energy Savers Program Energy Efficiency and Demand Response Programs December 4, 2012 USEA Global Workshop On Clean Energy Development

Below are detailed instructions for using the EMS load calculator.

Development Services City of Lawrence, KS

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Heating, Ventilation and Air-Conditioning (HVAC)

Does Wall Township require an inspection by the building department on resale of a home?

Residential Buildings Energy Code Summary

Home inspectors are not mold inspectors, however they do inspect for defects that

Residential Weatherization Plus Program

Energy Star Case Study on Blue Hills. Introduction

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

) SIGNIFICANT CHANGES INCLUDING CODE COMMENTARY

With colder weather approaching and heating costs continuing to skyrocket, ASHRAE is offering some simple ways to save energy and keep you and your

Residential Construction

BPC Green Builders. Green building for new and existing homes. Health Comfort Energy

Mississippi. Energy and Cost Savings. for New Single and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

FREQUENTLY ASKED QUESTIONS about HERS and CHEERS Provided by the California Energy Commission Consumer Energy Center

Steam systems require higher temperatures, which make them inherently less efficient than forced air or hot water.

Idaho Energy and Cost Savings

Energy and Cost Savings

Indiana Energy and Cost Savings

Existing Housing Stock

The Potential for Energy Retrofits within the City of Sacramento s Rental Housing Inspection Program

Sustainable Design and Energy-Efficient Building Techniques for Existing Housing

Colorado Energy and Cost Savings

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money

2015 SPECIFICATIONS MANUAL

Energy Conservation Audits for Six Performing Arts Facilities A Toronto s Green Theatres Project

Structure Survey Findings:

Preventing Ice Dams on Roofs

To: From: Date: Re: Summary

How To Design An Hvac Design For A Stick Built Home

Tennessee. Energy and Cost Savings. for New Single and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

Arapahoe County Residential Water Heater Installation and Inspection Guide

A Seller s Guide to the Home Inspection By

Green Building of Senior Housing - Nuts and Bolts - Community Housing Partners

APPENDIX C FORMS 2010 FLORIDA BUILDING CODE ENERGY CONSERVATION C.1

Schedule of Work Experience (OJL) and Training considered necessary to develop a skilled and productive worker.

Current Programs available to Limited Income Customers. Residential and Multifamily

Applications for building permits will not be reviewed until all of the required information has been submitted.

Total Home Inspection Checklist

Georgia Energy and Cost Savings

Accurate Home Inspection of Illinois. Property Inspection Report For Steve & Jenny Hynek 210 W.Chicago Ave., Westmont, Illinois

Solving Persistent Moisture Problems and Moisture Damage

Enclosing Timber Frames. Panels. Frank Baker Founder, Riverbend Timber Framing and Insulspan

Transcription:

Home Performance with ENERGY STAR COMPREHENSIVE HOME ASSESSMENT DETAILS I BUILDING INSPECTION: An interior and exterior visual inspection of the building will be performed to document building measurements, structural concerns, and existing conditions of the home. Moisture and Indoor Air Quality issues, which may impact the work scope, should also be evaluated. This evaluation will document: 1. Building volume and air tightness standard, (BAS) 2. Existing and required attic ventilation (sq. ft.) 3. Ambient CO, (carbon monoxide), monitoring 4. Gas leak testing (record pass or fail with corrective action or fail with no action required) 5. Any concerns about the structure including signs of moisture, mold, pre-existing damage to the building or the interior and other conditions that might affect testing II THERMAL ENVELOPE: Attic, wall, crawl space and basement insulation levels will be evaluated. Existing windows and doors will be inspected for type, overall fit and performance. 1. For each different shell component (attics, walls, basements, etc.) record the insulation material and estimated R-value 2. Record framing and glazing type and overall condition of windows 3. Record type and condition of exterior doors II A - REPORT REQUIREMENTS & SPECIFICATIONS: All effective R-values for insulation levels are based on the BPI technical standards Recommendations for additional insulation should be made if the existing level is at or less than the minimum existing R-Value listed in the table below unless there are health and safety, and/or structural issues preventing improvements. BUILDING COMPONENT MINIMUM EXISTING INSULATION LEVEL Attic Flat R-15 Attic Slope R-8 Knee Wall R-8 Knee Wall Floor R-15 ADDITIONAL CONCERNS All attic areas being insulated must be air sealed in accordance with BPI standards. High density insulation or wind shielding should be used when appropriate. Exposed fiberglass must be wind shielded using an appropriate air barrier. Knee Wall Floor transitions must be effectively air sealed with high density insulation or other means.

Attic Ventilation Exterior Walls Unheated Basement Ceiling Crawl Space Ceiling Ventilation should be installed to meet building code when adding insulation Garage Ceilings and Walls Adjacent to Living Space R-8 Cantilevers and Overhangs R-8 If minimal insulation levels exist, consider installing additional insulation material to improve thermal performance and/or reduce air leakage. Install insulation if the basement is unheated and the basement ceiling is air sealed. All ducts and pipes must be insulated/air sealed according to BPI standards. If existing insulation is in poor condition, damaged portions must be repaired or replaced. If existing insulation is wet, it must be removed. Install new insulation after all moisture sources have been addressed. All insulation to be installed as per BPI standards. Garage connections to the house must be air sealed according to BPI standards using high density insulation or other materials. Air seal using high density insulation or other materials where needed. III - DOMESTIC HOT WATER SYSTEMS: Evaluate existing conditions and inspect for proper operation and ventilation III A - REPORT REQUIREMENTS & SPECIFICATIONS: 1. Record the existing type and size of water heater (free standing, tank less, indirect, etc.) 2. Record the fuel type and venting type 3. Record the condition of the system Recommendations for new water heaters should be made if the existing system is in poor condition, improperly sized or creating a health risk that requires replacement. New installations must be in compliance with BPI standards for health & safety and proper sizing. IV - HEATING SYSTEM INSPECTION: Evaluate existing conditions, including the distribution system, and inspect for proper ventilation 1. For each combustion appliance record the estimated or measured efficiency 2. For each combustion appliance record the fuel type and venting type 3. Record the heating system distribution type

IV - A HEATING SYSTEM REPORT REQUIREMENTS & SPECIFICATIONS: WARM AIR FURNACE: Recommendations for new heating systems should be made if the existing system is in poor condition, improperly sized or creating a health risk that requires replacement. New installations must be in compliance with BPI standards for health & safety and proper sizing. Heating distribution systems will be inspected and evaluated for each of the following: Location, Condition, Insulation Levels and Leakage 1. Record the primary location of the heating distribution system 2. Identify if the distribution system is insulated or not insulated 3. Record evaluation of duct leakage (visual, pressure pan, or duct blaster). a) Visual: Record Good, Fair or Poor with respects to estimated visual leakage b) Pressure Pan: Record the number of registers that have a reading at or higher than 3 pascals (optional at the time of the assessment) c) Duct Blaster: Record the results of total leakage (in CFM25) (optional at the time of the assessment) DUCT INSULATION: Heating distribution duct work must be insulated according to BPI standards. Duct work should be sealed according to BPI specifications. HYDRONIC BOILERS: Recommendations for new heating systems should be made if the existing system is in poor condition, improperly sized or creating a health risk that requires replacement. New installations must be in compliance with BPI standards for health & safety and proper sizing. Heating distribution systems will be inspected and evaluated for each of the following: Location, Condition, and Insulation Levels. 1. Record the primary location of the heating distribution system. 2. Identify if the distribution system is insulated or not insulated PIPE INSUALTION: Heating distribution pipe must be insulated according to BPI standards V - HEALTH & SAFETY INSPECTIONS: Following BPI procedures, carbon monoxide testing will be performed on all combustion appliances in the home. Additional testing will be performed on heating and domestic hot water equipment to evaluate spillage of combustion gases, drafting of appliances, and worst-case depressurization. 1. Record worst case CAZ depressurization. 2. Record results of spillage evaluation (pass/fail) for each vented appliance. 3. Record measured draft under worst case for each vented appliance.

4. Record carbon monoxide measurements for each appliance (including ovens). 5. If any of the above measurements cannot be made, document why. V - A HEALTH & SAFETY REPORT REQUIREMENTS: Based on the results of the tests make recommendations for corrective action based on BPI standards including repair or replacement of appliances. VI BUILDING LEAKAGE TEST: A blower door test will be performed to determine the current air leakage rate of the building. The test will also be used to target the level and type of air sealing and/or mechanical ventilation required. 1. Record the building leakage rate in CFM50. 2. Record existing type of mechanical ventilation (none, exhaust only, supply & exhaust etc.) 3. Record required mechanical ventilation in cfm. (Building air tightness standard, (BAS), already recorded when building measurements are taken.) 4. Identify primary and secondary air sealing locations based on inspection and blower door diagnostic tests (visual, blower door guided walkthrough, pressure diagnostics, smoke test, etc.) VI - A BUILDING LEAKAGE REPORT REQUIREMENTS & SPECIFICATIONS: Building Air Sealing: Recommendations for attic air sealing must be made when the building has any attic insulation or ventilation work recommended. In addition, air sealing is to be recommended on homes if the blower door diagnostic indicates primary leakage paths from the building shell to the exterior even if mechanical ventilation may be required before or after the work is performed. The Building Air tightness Standard (BAS) is designed as a guideline for determining when mechanical ventilation is required. The BAS should not be used to limit air sealing work when leakage paths from the building shell to the exterior are present. Refer to the BPI standards and program guidelines for guidance on prioritizing air sealing measures. VII - APPLIANCE AND LIGHTING MEASURES: Major appliances and lighting fixtures should be evaluated to determine if newer energy efficient models are beneficial 1. Record existing refrigerator model number and age 2. Record existing high use lighting 3. Identify recommended upgrades for appliances (refrigerator, dishwasher, clothes washer, etc.)

VII - A - REPORT REQUIREMENTS & SPECIFICATIONS: LIGHTING IMPROVEMENTS: A recommendation for appropriate amounts & types of compact fluorescent bulbs shall be made. Evaluation of hardwired fluorescent fixtures should also be made where appropriate. APPLIANCE IMPROVEMENTS: Recommendations for ENERGY STAR appliances should be made if they do not exist at the time of the visit. This includes Clothes Washers, Refrigerators and Dishwashers. VIII - EVALUATION & RECOMMENDATIONS REPORT: The Contractor will prepare a detailed report for the client that will list the results of the inspection and information on having the recommended improvements installed in the home. This report will list the individual measures along with cost and saving estimates. The Comprehensive Home Assessment (CHA) MUST include all Health and Safety measures, as well as any measures with a predicted payback of seven years or less or a positive return on investment (ROI). Information on low interest financing, participant incentives and loan applications will also be addressed for the client. This document is designed as a summary of a Comprehensive Home Assessment and may not address some of the issues encountered in the field. The required recommendations should be considered minimums for proposals and are not designed to limit or restrict the contractor's ability to install building performance measures desired by the customer. The Home Performance with ENERGY STAR program standards and eligible measures will dictate which measures qualify for incentives and financing through the program. BPI standards should always be followed when conducting assessments, inspections, and diagnostics, making recommendations or proposals, and performing work.