Hazardous Areas Current trends in industry

Similar documents
CONSULTING Training Courses

INTERNATIONAL STANDARD

HAZARDOUS AREA TECHNICAL GUIDE

Electrical Equipment in Hazardous Areas: Field Inspections

Making sense of Intrinsic Safety and Intrinsically Safe Tools

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

Controlling fire and explosion risks in the workplace

Terminal Box. Specifications TNCN

Ex q Powder Filling. This is a technique primarily used for oil filled switch-gear. The spark is formed under oil and venting is controlled.

David O Brien, CMP Products (David.OBrien@cmp-products.com)

WORKING IN CONFINED SPACES GUIDELINES

Process Safety Management of Highly Hazardous & Explosive Chemicals. Safe Work Practices

Fire & Explosion Risks in Service Stations

An inventory of hazardous materials used in your workplace will prove useful.

Hazardous Area Classifications and Protections

Hazardous location. Definitions

STORE HAZARDOUS SUBSTANCES SAFELY. incompatibles gas cylinders

Hazardous Area Classifications and Protections

Safety instructions VEGADIS DIS81.CEIA/V****

Hazardous Locations Training

5/3/2010. Article 500 address the requirements for hazardous locations: Wiring Equipment

Guide to Certification for Retail Hardware Stores

Design, testing, certification, installation & maintenance

Area Classification Why? Where? How? Who? When?

Mechanical Systems Competency 1.20

Instructions for Safe Use

Explosion Protected White Paper Series #1: Imaging Challenges in Explosive Environments

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Ethanol Vehicle and Infrastructure Codes and Standards Citations

Basics of Explosion Protection

Explosion Protected Electrical Apparatus in the Russian Federation

Compressed Gas Cylinder Program

Article Scope Definitions. Article 505. Class I, Zone 0, 1, and 2 Locations. 52 Cooper Crouse-Hinds Code Digest

Guide on the Segregation, Packaging, Labelling and Storage of Laboratory Chemical Wastes for Schools

distributing & controlling system solutions

IECEX CERTIFICATION SCHEMES VERSUS ATEX DIRECTIVES

Safe Use of Flammable and Explosive Substances: A Guide to DSEAR in the University. Safety and Environmental Protection Services

HSE information sheet. Fire and explosion hazards in offshore gas turbines. Offshore Information Sheet No. 10/2008

ATEX Fans 08/02/2008. Data subject to change without prior notice

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

In addition, flammable solvents and thinners are often mixed with the above substances.

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Confined spaces can be deadly. What is a confined space?

Guidance on Process Safety Performance Indicators

State Records Guidelines No 23. Certification for Places of Deposit of State archives

No. Name of Legislation Applicable Issues and Requirements Demonstration of Compliance 1. Health and Safety at Work Act 1974

Today's world of increasing

Practical Guidelines for Electrical Area Classification in Combustion Turbine-Generator Power Plants

Compressed Gas Cylinder Safety

GAS CYLINDER SAFETY. 2. GRADES OF GASES BOC have divided the gases that they supply into 3 grades.

Professional Series ATEX Portable Radios

Work Permits. A Health and Safety Guideline for Your Workplace. When is a Work Permit Needed? What is a Work Permit? Why use a Work Permit?

Understanding European versus U.S. temperature code ratings for solenoidoperated. A White Paper From ASCO

Pressure Vessels (Air Compressors) and LPG Tanks

How To Protect An Explosion

BRAZILIAN CERTIFICATION SYSTEM

68 Metal Industry Guidelines for Safe Work

Design Safety Standards for Electrical Systems: Hazardous (classified) Locations -- OSHA Standard

Class/Division Hazardous Location

Guide Document for Development of WHS Management Plans

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

ARE YOU IN COMPLIANCE WITH THE OSHA COMBUSTIBLE DUST DIRECTIVE? Revised March 18, 2009

FLAMMABLE LIQUIDS COMPLIANCE NOTE

Illinois Manufacturers Best Practices January 2016 Webinar

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

Guidance for Those Who Use and Store Gas Cylinders

SITE CONTRACTOR PROCEDURES

Liberty Mutual Insurance RISK ENGINEERING PROCEDURE. REP 07 Incident Planning For external use

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

Fire Alarm System Accessories

Fig. 2 Option 1 Integrated Design using Physical Separation. Fig. 1 Standard Modular Process Skid Design Concept

Explosion Prevention

HOT WORK PERMIT PROCEDURES

Design of intrinsically safe systems

An Introduction to ATEX -

ATEX GUIDELINES (FIRST EDITION)

Commercial Garages, Repair, and Storage

Brochure. ABB Customer Training Program for Motors and Generators Sharing knowledge and creating value

Combustible Dust - Things that go Boom. W. Jon Wallace, CSP, MBA Workplace Group, LLC O: E: jwallace@workplacegroup.

SEISMIC VELOCITY TRANSDUCER T1-40

Wilkins Safety Group

Gas Detector System, Portable/Fixed Oxygen Analysis and Gas Detection Equipment

Combustible Dust Ensuring Safety and Compliance. Brian Edwards, PE Conversion Technology Inc. ENVIRONMENTAL & SAFETY CONSULTING ENGINEERS

CLASSIFICATION NOTES

FLA S FIRE SAFETY INITIATIVE

Loading Master Training 2015

FIRE SAFETY GUIDANCE NOTE Risk Assessments for Petrol Filling Stations Required Under Fire Safety Legislation

IGEM/UP/16 Communication 1756

STORAGE AND HANDLING OF DANGEROUS GOODS

LIQUID WASTE TREATMENT FACILITY MENDIS ROAD, HUDSON CREEK DRAFT GUIDELINES FOR A PUBLIC ENVIRONMENTAL REPORT

Ingredion ANZ Pty Ltd

SAFETY AND HEALTH PROGRAM

By: Santiago Consunji American Industrial Systems, Inc.

Site and Storage Conditions for Class 3.1 Flammable Liquids

Safe Work in Confined Spaces

RESTRICTED ACCESS AND CONFINED SPACES

Safety and Health Office WORKPLACE SAFETY CHECKLIST

2.12. page Products for Explosion hazardous Environment

99/92/EC (ATEX 137) USE

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Transcription:

Hazardous Areas Current trends in industry Carolyn Yates Technical Director, Energy and Resources Aurecon Northern Territory

Hazardous Areas Current trends in industry Overview A few hazardous area basics Classification Explosion protection techniques and equipment Current trends in area classification Design and installation Inspection and maintenance Common myths Some of the interesting stuff 2

Introduction The disclaimer.. Before we start, this presentation is based on Australian requirements and jurisdictions. When working on projects in other areas of the world, it is important to find out what the requirements are in the location and follow them. This presentation is designed to give a basic introduction to hazardous areas and to provide some of my own experiences as hazardous area designer, inspector and auditor. It is not a competency course. 3

What is a hazardous area? Definition: Hazardous area Hazardous area definitions are found in several Australian Standards. This definition for a hazardous area comes from AS/NZS 3000 Clause 1.4.11. Area in which an explosive atmosphere is present, or may be expected to be present, in quantities such as to require special precautions for the construction, installation and use of equipment [AS/NZS 60079.0]. 4

What is a hazardous area? What does it really mean? An area that contains, or is reasonably expected to contain flammable gases or vapours or combustible dusts, fibres or flyings. Generally if you have flammable gases or liquids, or combustible dusts, you will most likely have a hazardous area. 5

Around Darwin.. Darwin LNG (and Inpex Ichthys will also have some areas) Power stations (Channel Island, Weddell) Industrial facilities, such as the Vopak Fuel Terminal Some maybe less obvious examples: Service stations (bowsers and tanks) LPG refilling areas (eg BCF, BBQs Galore) Laboratories Airports (including aircraft hangars) Workshops (welding bays where acetylene is used) 6

Did you know? Flour (grain), white/granulated sugar and cocoa are highly explosive and come under the heading of combustible dusts Some of the worst industrial explosions have been due to combustible dusts. 7 Other examples include coal, citric acid

Something to note It is rarely possible by simple examination of a plant or plant design, without extensive experience, to decide which parts of the plant are hazardous areas. More detailed information is necessary and this involves the analysis of the basic properties of the materials present and the possibility of a release occurring. Hazardous area classification is a specialist area. 8

Which of these plants contain a hazardous area? 9 Plant A Plant B

Classification Hazardous area classification divides areas in to Zones based on the likely frequency and duration of a release, release rate, concentration, velocity and ventilation of the area. Hazardous area classification zones include 10 but this is not the whole picture.

Classification Example of Zones for Gases & Vapours AS/NZS 60079.10.1 Figure ZA.4 11

Classification - Jargon Alert! Classification also considers the materials being considered and assigns an equipment group and temperature classification to the area based on the material properties. Temperature class T1, T2, T3..T6 (400 C down to 85 C) How hot the thing gets.. Also known as the autoigntion temperature Equipment/Apparatus or Gas group - IIA, IIB, IIC How much energy it has the spark energy.. IIA is the least onerous, IIC the most 12 And this is the area that gets forgotten about

Common myths - Round 1 We will just go with the worst case scenario and say that all equipment installed needs to be IIC T6. Your installation will be very dark as you won t be able to buy a light fitting. But what about hydrogen? IIC gas explosive..but Has an incredibly high autoigntion temperature - 560 C, which makes it a T1 requirement Acetylene is a nastier gas Takeaway point - You need to check. It s not always obvious. 13

Current trends in classification The classic approach still in use is via examples in AS/NZS 60079.10.1 Equipment Protection Levels (EPLs) introduced in the last update to the standard Photo Vopak Darwin (vopak.com) 14

Current trends in classification What about other areas? (That are not covered in AS/NZS 60079.10.1 ): Fuel wharves and berths (ship loading and unloading) Diesel areas 15

Other areas International standards to the rescue! IP15 Good for fuel wharves and berths (ship loading and unloading) API RP 505 Diesel areas Dispersion Modelling for those other hard to determine areas Gas pipeline pressure relief/venting 16

Diesel areas About diesel. Flashpoint is generally 61 C, which makes it a combustible Australian standards only require you to consider hazardous areas for combustible liquids which are being handled above (flashpoint 6 degrees).this is 55 C for diesel 17

Diesel areas Manufacturer caution Ullage spaces within tanks Hazards from misting So why talk about it? Some companies are taking a very conservative line and are treating all diesel as a flammable, in case the 55 degree mark is breached But, many diesel installations are classified as non-hazardous. Which way do you go? 18

Design and installation Back in the bad old days.. Now.. The design and installation of a hazardous area installation must be completed by competent persons to AS/NZS 4761. It involves correct selection of explosion protection techniques and installation requirements for the classified areas. 19

Design and installation 20 There are many things to consider: Explosion protection techniques Ambient conditions Cable selection Location of equipment Additional electrical requirements for different protection techniques Certificates of conformity for equipment Information for inclusion within the verification dossier

Common myths Round 2 Intrinsically safe areas No such thing All hazardous area equipment is intrinsically safe No it s not. Other protection techniques are often in use Only industrial plants have hazardous areas No again! Also found in education facilities, commercial buildings, etc 21

Equipment - Explosion protection techniques There are many different explosion protection techniques. The most common ones are: Flameproof enclosures d Increased safety e Intrinsic safety i Non-sparking n Encapsulation m Special protection s Protection by Enclosure td (used to be DIP) Refer to Sylvania Lighting Information Sheet 22

Design and installation Flameproof (Ex d) motor: 23

Design and installation Non-sparking (Ex na) light fitting: 24

Design and installation Intrinsically safe (Ex i) level transmitter..the one time it s ok to call something intrinsically safe..when it actually is. 25

Inspection and maintenance People performing inspections or maintenance shall be competent. Inspections conducted to AS/NZS 60079.17 Initial, detailed grade inspections on completion of installation Maximum timeframe of 4 years between inspections Periodic inspections can be close or visual, however if major defects are found, should be upgraded to detailed inspections Defects must be rectified as soon as practicable 26

Inspection and maintenance In Queensland and Victoria, it is mandatory for a third party to complete an inspection of the installation to confirm compliance with standards and that the installation is safe. The inspector will provide a permission to energise when they are happy that the installation is safe and compliant. This is not a legislative requirement in the NT, however many industrial sites will insist on a third party verification of new installations prior to energisation. 27

Some of the interesting stuff Why you should use proper flameproof barrier type glands..\..\videos\aplng Cable.mp4 28

Some of the interesting stuff Sir Samuel Griffiths Centre hydrogen fuel cell facility Imported European equipment modifications required for Australian standards 29

Some of the interesting stuff Laboratory Chemical Waste Collection System Dispersion modelling to reduce zone extents 30

Some key takeaways. 1. If you have a hazardous area installation, get competent personnel involved early this saves changes later which are more expensive 2. Use the risk control hierarchy to reduce the size of the zones or the equipment installed within them 3. Hazardous areas is a specialist area if you want to work in this area, get trained and competent 31

Further Information Standards Australia Publications HB13 Handbook: Electrical equipment for hazardous areas AS/NZS 60079.10.1 Explosive atmospheres Part 10.1: Classification of areas Explosive gas atmospheres AS/NZS 60079.10.2 Explosive atmospheres Part 10.2: Classification of areas Combustible dust atmospheres AS/NZS 60079.14 Explosive atmospheres Part 14: Electrical installations design, selection and erection 32 AS/NZS 60079.17 Explosive atmospheres Part 17: Electrical installations inspections and maintenance

33 Questions?