MSA PrimaX IR Gas Monitor. Reliable Performance in Extreme Conditions

Similar documents
Ultima X Series Gas Monitors

MSA Fixed Gas & Flame Detection for the Oil, Gas & Petrochemical Industries

Sieger Searchpoint Optima Plus

Automated Test System SIMPLICITY COUNTS MSA s New GALAXY GX2 Automated Test System / Advanced Safety Management Effortless Operation

S-series Mass Connection Solutions

Ultrasonic Gas Leak Detection

Engineering Specifications XNX Universal Transmitter

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Technical Information RIA14

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

TEIP11 I/P signal converter for standard signals. Measurement made easy

Micro Motion 3098 Gas Specific Gravity Meter

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Buckeye Detection Systems Fixed Detection Systems Application Survey

Technical data sheet TDS0070

Lockout Specification BW Clip Maintenance-free single gas detector

Application Requirement

MSA Fixed Gas & Flame Detection for the Water & Wastewater Industries

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Power Supplies 3. SDN-P DIN Rail Series

TEIP11-PS I/P signal converter for standard signals. Measurement made easy

3500/62 Process Variable Monitor

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Technical Data. Dimensions

Microcor Wireless Transmitter (MWT)

SEISMIC VELOCITY TRANSDUCER T1-40

DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

S300 Series Dust Monitors

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

How To Use A Ds340 (Dsp)

sierra monitor corporation Fire and Gas Detection Systems

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Technical Specifications

Rosemount 333 HART Tri-Loop

Worcester DS/DM Series UltraSwitch Switch box

ALTAIR 5X Multigas Detector Bid Specification

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

Duct Humidity Transmitter

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

3DLevelScanner II TECHNICAL DATA SHEET

Plastic tube flowmeters Series PT/PS

OPTIMASS 1400 Technical Datasheet

Triple Waveband Infra-Red Flame Detection

Electronic Control Devices The European Product Catalogue 2007

Data Sheet PS1B Pressure Switch

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

MERIDIAN UNIVERSAL GAS DETECTOR TECHNICAL DATA PACKAGE

TABLE OF CONTENT

SAFETY MANUAL. Ultima OPIR-5 Infrared Open Path Gas Detector

Proximity Transmitters and Seismic Vibration Transmitters

RGC-IR Remote Gas Calibrator for IR400

Precision digital pressure gauge Model CPG1500

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Fire & Security DETECTORS

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

The L&J Engineering Model MCG 1500SFI Servo Gauge

Electronic, Digital and Mechanical Vibration Switches

Rosemount 333 HART Tri-Loop

Model: DC-A2IO Advanced HVAC Controller

2.12. page Products for Explosion hazardous Environment

IMVIB. Online vibration monitoring for Ariel compressors

Humidity Sensor. Model HU-224/225

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

COMBIMASS. Technical Data COMBIMASS eco-bio +

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

How To Use An Irius Pid Detector

Retractable Housings. InTrac 781 / 784 Versatile and Rugged For the Toughest Process Conditions INGOLD

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

USB-500/600 Series Low-Cost Data Loggers and Accessories

Fisher FIELDVUE DVC6200 SIS Digital Valve Controller for Safety Instrumented Systems (SIS)

S-series DeviceNet Interface Card

Terminal Boxes Series 8146

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

FCI ST75 Series Flow Meters

Plug and Socket Devices CES 63 A Series 8579

Technical Data. Dimensions

and Accelerometers

Power supply unit Model: PAC-SC50KUA

Rosemount 752 FOUNDATION fieldbus Remote Indicator

Analytical Instruments Smart Analyzer 90 Type SMA

Electronic Control Devices The European Product Catalogue 2007

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement

MIT510/2, MIT520/2 and MIT1020/2

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

Flow switches Series AD/VH

Inductive sensor NI10-M18-Y1X-H1141

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Dew-Point Measurement Solutions

Thermatel Enhanced Model TA2 Thermal Mass Flow Meter

Foxboro Evo Process Automation System

Rosemount 751 Field Signal Indicator

Transcription:

MSA PrimaX IR Gas Monitor Reliable Performance in Extreme Conditions

MSA PrimaX IR Gas Monitor Every feature of the SIL 2-certified PrimaX IR Gas Monitor is designed with reliability in mind to withstand the most challenging environmental conditions throughout the product s life. MSA s PrimaX IR Gas Monitor offers LEL (Lower Explosive Limit) combustible gas detection through a patent-pending PrimaX Gas Monitor IR dual-source design. A redundant IR source provides reliability and uninterrupted monitoring should a source failure occur. Furthermore, the possibility of obscurations due to rain, fog, dirt, dust, and other environmental conditions is minimized due to dual-source design. In addition, optics are optimized for maximum signal, resulting in a product of extraordinary stability. The PrimaX IR Gas Monitor provides reliable operation, just like I have come to expect from MSA. TB, Engineer 2 www.msasafety.com 1.800.MSA.INST

Installation The PrimaX IR Gas Monitor is designed for quick and easy installation. Stainless steel and aluminum junction boxes can be ordered pre-installed for further ease of installation and wiring. A unique environmental guard with patent-pending clamshell design provides convenient installation in tight locations. Calibration-Cap Method Users may choose the most suitable calibration method for their applications. A calibration cap is placed on the unit to provide one-person calibration. Calibration cap icon-driven user interface guides users through the calibration process. Calibration - HART Remote Method HART (Highway Addressable Remote Transducer) output provides remote calibration capability. A HART junction box is offered for local calibration in classified areas; HART software is available to initiate calibration from remote locations. Maintenance The PrimaX IR Gas Monitor is designed to minimize maintenance costs without replacement of internal components. The PrimaX IR Gas Monitor dual-source design reduces potential system faults due to obscurations caused by rain, fog, dirt, etc. This monitor provides maintenance alerts as well as other fault conditions over 4-20mA and HART outputs. www.msasafety.com 1.800.MSA.INST 3

Specifications Description Gas Types and Ranges Temperature Range Stability Repeatability Accuracy Response Times without environmental guard with environmental guard Humidity Sensor Warranty Power Input Current Draw Wiring Requirements Signal Output Physical Approval Ratings Ingress Protection HART Weight Dimensions Specification Hydrocarbon gases & vapors; 0-100% LEL -50 C to 75 C (-58 F to 167 F) ±2% full-scale/year ±1% full-scale ±2% full-scale ( 50% LEL) ±5% full-scale (>50% LEL) T90 <5 sec. Tested as per procedure in IEC 60079-29-1 For 50% LEL, 50% response in <5s, 90% response in <10s 0%-95% RH, non-condensing 10 years for IR source, 3-year full product 18-32 VDC, 5 watts (-40 C to 75 C) (-40 F to 167 F) 150mA RMS average @ 24VDC 3-wire, 2.0 mm max (14AWG) 4-20mA 3-wire current source with HART protocol 316 stainless steel 4.5 lbs. (2.0 kg) 3.5 dia. x 8 long (89 x 203mm) US and Canada cfmus Class I, Div. 1, Groups A,B, C, & D Class II, Div. 1, Groups E, F, & G Class III ANSI/ISA 12.13.01 CSA C22.2 No. 152 Combustible Gas Performance International CE EMC Directive: 2004/108/EC CE ATEX Directive: 94/9/EC II 2G Ex d IIc T4 IEC China Ex/CMC/CCCF Russia Ex/ GOST R (Tamb -50 C to 75 C) (-58 F to 167 F) IP67 Safety Integrity Level SIL 2 HART 7.0 compatible www.msasafety.com 1.800.MSA.INST 4

Features & Benefits Patented dual-source design provides redundancy and reliable, uninterrupted performance Patent-pending environmental guard sensor housing for fast, efficient response time Heated optics prevent condensation buildup 4-20mA analog output User-friendly setup, calibration, diagnostics, and maintenance via HART digital communication One-person calibration is easily performed using calibration cap Easy connection using aluminium or stainless steel junction box SIL 2-certification provides safety system integration capability 316 stainless steel, IP67-rated, rugged housing protects unit from environmental extremes Factory-calibrated for fast commissioning Heater element enables operation to -50 C (-58 F) Applications OGP including platforms, refineries, drilling rigs, and compressor stations Chemical plants Fuel-loading and storage facilities Wastewater Various industrial applications 5 www.msasafety.com 1.800.MSA.INST

Options & Accessories Calibration cap Stainless steel junction box HART junction box Duct-mount kit Sun shield Insect guard Flow cap Environmental guard tether Note: This bulletin contains only a general description of the products shown. While uses and performance capabilities are described, under no circumstances shall the products be used by untrained or unqualified individuals and not until the product instructions including any warnings or cautions provided have been thoroughly read and understood. Only they contain the complete and detailed information concerning proper use and care of these products. ID 07-1807-MC / March 2015 MSA 2015 Printed in U.S.A. MSA The Safety Company 1000 Cranberry Woods Drive Cranberry Township, PA 16066 USA Phone 724-776-8600 www.msasafety.com U.S. Customer Service Center Phone 1-800-MSA-INST Fax 1-800-967-0398 MSA Canada Phone 1-800-MSA-INST Fax 1-800-967-0398 MSA Mexico Phone 01-800-672-7222 Fax 52-44 2227 3943 MSA International Phone 724-776-8626 Toll Free 1-800-672-7777 FAX 724-741-1553 Email msa.international@msasafety.com