IEC The new standard for low-voltage switchgear and controlgear assemblies

Similar documents
The easy way to build switchgear and controlgear assemblies in compliance with the regulations

Changing industry standards: friend or foe?

Standard-compliant switchgear and controlgear production

IEC >>> IEC GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

FAQs-Main switchboard design criteria

IEC & 2 standard. The reference for safe and reliable LV switchboards

Technical Application Papers No.11 Guidelines to the construction of a low-voltage assembly complying with the Standards IEC Part 1 and Part 2

Unified requirements for systems with voltages above 1 kv up to 15 kv

Power transformers. Special transformers Railway

Insulation resistance

DEVICES OF PROTECTION AND COMMAND

Three-phase monitoring relay CM-PFE

Technicaldata General

Electronic overload relay EF65, EF96 and EF146

MNS is Switchgear System Technical Overview

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Electronic overload relay EF19 and EF45

IEC specifications for LV assembly switchboards

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Guidance for upgrading to GB (IEC : 2005, MOD)

UFES Active protection for switchgear

COMPARISON OF ANSI/IEEE AND IEC REQUIREMENTS FOR LOW- VOLTAGE SWITCHGEAR

Securing your electrical installations Prisma,

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

Power transformers. Generator step-up and system intertie power transformers Securing high-quality AC transmission

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

The power distribution board that sets new standards

ELECTRICAL DOCUMENTATION ACCORDING TO STANDARDS

INTERNATIONAL STANDARD

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

The Importance of the X/R Ratio in Low-Voltage Short Circuit Studies

GUIDE FOR TESTING POWER TRANSFORMERS

6 ELECTRICAL PARAMETERS

TYPE TEST CERTIFICATE OF SHORT-CIRCUIT PERFORMANCE. A three-phase outdoor oil-immersed distribution transformer

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

Guide to the electrical parameter classifications of IEC and IEC safety standards

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

Low Voltage Products. Switches Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

SURGE PROTECTIVE DEVICES

IEC in ZX Gas-insulated medium voltage switchgear

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

KAM A Lighting Busbar System KAP A Plug-in Busbar Distribution System

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

SIVACON The Versatile Low-Voltage Switchboard

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

4 Technical Application Papers

INTERNATIONAL STANDARD

HIGH VOLTAGE SHORE CONNECTION

5SV Residual Current Protective Devices

Low Voltage Switchgear MNS is with MSpeed

Comparative study for cables and busbars

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Service Power Technologies. Retrofitting A future-oriented concept in lifecycle management

Manuals and Software Tools for Power Distribution Engineering

Catalogue May EasyLine XLP Fuse Switch Disconnector pole

Title 20 PUBLIC SERVICE COMMISSION. Subtitle 50 SERVICE SUPPLIED BY ELECTRIC COMPANIES. Chapter 02 Engineering

INTERNATIONAL STANDARD

Modular Systems wind portfolio overview Power Collection and Grid Connection products

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

INTERNATIONAL STANDARD

Engineering Series Ratings: Is It Practical?

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

04 / Panel Design Configurator The modular planning software for low voltage distribution systems

Electrical Shore Connections / Cold Ironing

LightingEurope EU Compliant Requirements Products Sheets for LIGHTING COMPONENTS

P System Cubicles. Certified for more safety

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Nothing s BetterThan the Original MODAN Power Distribution Systems

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS

Industrial Process Plants. Residential & Commercial Buildings. Roads & Tunnels. Airports & Seaports

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Modan 3000 ADVANCED TECHNOLOGY, INDUSTRIAL GRADE MOTOR CONTROL CENTER. Systems Products and Services. Motor Control Centers Modan 3000

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

Guidelines on the Short Circuit Current Rating for Industrial Control Panels

SAFETY ALERT SWITCHBOARD INTERNAL SEGREGATION AND IP RATING. May 2014 BACKGROUND

The Intelligent AX1 Switchgear for Medium Voltage

Arc Flash Hazards. Electrical Hazards. Dan Neeser Field Application Engineer Electrical Hazards 2/18/2015. Shock.

System pro M compact Miniature Circuit Breaker S 200/S 200 M

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Transcription:

11 2010 IEC 61439 The new standard for low-voltage switchgear and controlgear assemblies

2 IEC 61439 The new standard

Content Page Introduction... 4 The current IEC 60439... 5 The new IEC 61439... 6 Main changes... 7 Responsibilities...12 FAQ...14 Summary and conclusion...16 IEC 61439 The new standard 3

Introduction A low-voltage switchgear and controlgear assembly (ASSEMBLY) is a combination of low-voltage switching devices together with associated equipment (for controlling, measuring, signalling, etc.) complete with all the internal mechanical and electrical interconnections and structural parts. As with every component of an electrical installation, the ASSEMBLY also has to comply with its appropriate standard. In January 2009 the IEC 61439, the new standard for lowvoltage switchgear and controlgear ASSEMBLIES, was published. This was the aim of an international project group which had been working on a task named radical restructuring and revision of IEC 60439 series since 1998. This initiative was introduced by several countries following dissatisfaction with the IEC 60439 series. The purpose was to harmonise and define all general requirements for low-voltage electrical ASSEMBLIES. Reaching an agreement has proven extremely challenging, but the first parts of the new standards have been published. For each type of electrical ASSEMBLY only two parts of the standard are necessary to determine all requirements: the basic standard IEC 61439-1 General rules the specific ASSEMBLY standard The aim of this guide is to allow panel builders, electrical installers, planners or purchasers to familiarise themselves with the new standards and to point out the main changes that have been introduced as well as elements that remain unchanged. 4 IEC 61439 The new standard

The current IEC 60439 The current IEC 60439 standard applies to enclosures for which the rated voltage is under or equal to 1000 V AC (at frequencies not exceeding 1000 Hz) or 1500 V DC. The standard makes a distinction between type-tested assemblies (TTA) and partially type-tested assemblies (PTTA).The following parts are mentioned and have equal weighting. There is not a formal hierarchy. Each part is a complete entity and can be used on an individual basis: IEC 60439-1 type-tested and partially type-tested assemblies IEC 60439-2 particular requirements for busbar trunking systems (busways) IEC 60439-3 particular requirements for low-voltage switchgear and controlgear assemblies which are to be installed in locations where unskilled persons have access for their use. IEC 60439-4 particular requirements for assemblies for construction sites (ACS) IEC 60439-5 particular requirements for assemblies intended to be installed outdoors in public places Cable distribution cabinets (CDCs) for power distribution in networks The standard remains valid until 2014 IEC 61439 The new standard 5

The new IEC 61439 The new IEC 61439 standard applies to enclosures for which the rated voltage is under 1000 V AC (at frequencies not exceeding 1000 Hz) or 1500 V DC. The standard defines the design verified ASSEMBLIES and eliminates completely the categories TTA and PTTA. In order to conform to the standard, type tests have been replaced by a design verification which can be carried out by the three following equivalent and alternative methods: testing, calculation/measurement or application of design rules. The following parts are mentioned and do not have equal weighting. There is a formal hierarchy. Each part can not be used individually: IEC 61439-1 General rules IEC 61439-2 Power switchgear and controlgear ASSEMBLIES IEC 61439-3 Distribution boards IEC 61439-4 ASSEMBLIES for construction sites IEC 61439-5 ASSEMBLIES for power distribution Part 1 is the general rules part and cannot be used alone to specify an ASSEMBLY. Part 2 defines the specific requirements of power switchgear and controlgear ASSEMBLIES (PSC ASSEMBLIES) and must be used with Part 1. This is the only part that has a double role, it covers PSC ASSEMBLIES and any ASSEMBLY which is not covered by any other specific parts. Parts 3-X are still under preparation but are already mentioned in Part 1. These could be more than four, as additional parts may be developed as the need arises. Summarising: With the currently used IEC 60439, the rule is one part for each type of ASSEMBLY. With the new IEC 61439 the rule is two parts for each type of ASSEM- BLY. The compliance of an ASSEMBLY is declared referring to the specific ASSEMBLY standard (e.g. IEC 61439-2), and the compliance with the general rules (IEC 61439-1) is always implicit. The sentence TTA switchgear according to IEC 60439-1 is now replaced by Power switchgear and controlgear ASSEMBLIES according to IEC 61439-2, design verified ASSEMBLY. The validity of the two standards will overlap until 2014 and prior to this date, ASSEMBLIES can be manufactured according to IEC 61439 or IEC 60439. IEC 61439-6 Busbar trunking systems Relationship between the two standards is as shown in the table below: IEC 61439-1 IEC 61439-2 replaces IEC 61439-6 will replace IEC 61439-3 will replace IEC 61439-4 will replace IEC 61439-5 will replace IEC 60439-1 (still valid until 2014) IEC 60439-2 (still valid) IEC 60439-3 (still valid) IEC 60439-4 (still valid) IEC 60439-5 (still valid) 6 IEC 61439 The new standard

Main changes More than a single digit change The new IEC 61439 includes the following significant technical changes with respect to the last edition of IEC 60439. Responsibility split: New terms have been introduced and there is a split in product responsibility between the Original manufacturer (e.g. ABB, responsible for carrying out the original design and the associated verification of an ASSEMBLY) and the ASSEMBLY manufacturer (e.g panel builder using an ASSEMBLY system from an Original Manufacturer) assuming responsibility for the completed ASSEMBLY. The Assembly Manufacturer may be a different organisation to the Original Manufacturer. Where the ASSEMBLY Manufacturer introduces changes to the ASSEMBLY configuration tested by the Original Manufacturer, he is deemed to be the Original Manufacturer in respect of these changes and has to carry out the design verification. Three different but equivalent types of verification of requirements are introduced: Verification by testing (test made on a sample of an ASSEM- BLY or on parts of ASSEMBLIES to verify that the design meets the appropriate requirements. This method is equivalent to the currently implemented type tests). Verification by calculation/measurement (calculations applied to a sample of an ASSEMBLY or to parts of ASSEMBLIES to show that the design meets the appropriate requirements). Verification by application of design rules (specified rule to verify the design of an ASSEMBLY). The selection of the appropriate verification method has to be made according to annex D, which explains the available verification options for each characteristic which is to be verified, as shown in the table below: Design verification replaces TTA and PTTA categories: Design verification replaces type tests so the discrimination between type-tested assemblies (TTA) and partially typetested assemblies (PTTA) is eliminated. Characteristic to be verified Verification by testing Verification options available Verification by calculation Verification by design rules 10.2 Strength of material and parts Yes No No 10.3 Degree of protection of enclosures Yes No Yes 10.4 Clearances and creepage distances Yes Yes Yes 10.5.2 Effective continuity between parts and PE Yes No No 10.5.3 Effectiveness of the ASSEMBLY for external faults Yes Yes Yes 10.6 Incorporating of apparatus No No Yes 10.7 Internal electrical circuits and connections No No Yes 10.8 Terminals for external conductors No No Yes 10.9.2 Power frequency withstand voltage Yes No No 10.9.3 Impulse withstand voltage Yes No Yes 10.10 Temperature rise limits Yes Yes Yes 10.11 Short-circuit withstand strength Yes Yes Yes 10.12 EMC Yes No Yes 10.13 Mechanical operation Yes No No IEC 61439 The new standard 7

Main changes More than a single digit change Tests that have been made in accordance with IEC 60439 and that fulfil the requirements of the new IEC 61439 need NOT be repeated. The second stage verification is the routine verification. This is performed to verify that the materials and workmanship are in accordance with the requirements of the standard. Routine verification replaces the current routine test. It is more detailed but essentially the new requirements are the same as in the IEC 60439. This verification has to be carried out for each completed ASSEMBLY and it is the responsibility of the ASSEMBLY Manufacturer. Comparison between the current and the new verification flow : IEC 60439 ASSEMBLY low-voltage switchgear and controlgear ASSEMBLIES type tests for verification of conformity system manufacturer manufacturer of the ASSEMBLY TTA type-tested units type-tested ASSEMBLIES PTTA partial type-tested ASSEMBLIES routine test not type-tested units completed ASSEMBLY 8 IEC 61439 The new standard

IEC 61439 ASSEMBLY low-voltage switchgear and controlgear ASSEMBLIES original manufacturer ASSEMBLY manufacturer original manufacturer design verification carried out by the original manufacturer testing calculation application of design rules ASSEMBLY system The ASSEMBLY manufacturer can decide: to manufacture the ASSEMBLY according to the guidelines of the original manufacturer t o deviate from the guidelines of the original manufacturer. Where the ASSEMBLY manufacturer incorporates his own arrangements not included in the original manufacturer s verification, the ASSEMBLY manufacturer is deemed to be the original manufacturer in respect of these arrangements. routine verification completed ASSEMBLY IEC 61439 The new standard 9

Main changes More than a single digit change Additional verification: New requirements from the standard IEC 62208 (Empty enclosures for ASSEMBLIES) have been added: verification of resistance to UV radiation for outdoor plastic enclosures verification of corrosion resistance mandatory declaration and confirmation of an impulse rating lifting, mechanical impact and marking Other changes Temperature rise Temperature rise requirements have been explained more clearly and have been adapted to the state of the art. One of the following methods is allowed for verification: testing with current derivation (from a tested design) of ratings for similar variants calculation (see also FAQ chapter) Tests described in IEC 61439-1 in comparison with the type tests described in IEC 60439 No. Characteristics to be verified Clause/Subclause Comparable type test from 60439-1 1 Strength of material and parts Resistance to corrosion 10.2 10.2.2 Not required as Type test but as Design and Properties of insulating materials 10.2.3 construction rules Thermal stability 10.2.3.1 on paragraph 7 or on subsidiary standard Resistance of insulating materials to normal heat 10.2.3.2 Resistance to abnormal heat and fire due to internal electric effects 10.2.3.3 Resistance to ultra-violet (UV) radiation 10.2.4 Lifting 10.2.5 Mechanical impact 10.2.6 Marking 10.2.7 2 Degree of protection of enclosures 10.3 8.2.7 3 Clearances and creepage distances 10.4 8.2.5 4 Protection against electric shock and integrity of protective circuits 10.5 Effective continuity between the exposed conductive parts of the ASSEMBLY and the protective circuit 10.5.2 Effectiveness of the ASSEMBLY for external faults 10.5.3 8.2.4 5 6 Incorporation of switching devices and components Internal electrical circuits and connections 10.6 10.7 Not required as Type test but as Design and construction rules 7 Terminals for external conductors 10.8 on paragraph 7 or on subsidiary standard 8 Dielectric properties 10.9 Power -frequency withstand voltage 10.9.2 8.2.2 Impulse withstand voltage 10.9.3 9 Temperature rise limits 10.10 8.2.1 10 Short-circuit withstand strength 10.11 8.2.3 11 Electromagnetic compatibility (EMC) 10.12 + Annex J 8.2.8 + Annex H 12 Mechanical operation 10.13 8.2.6 10 IEC 61439 The new standard

RDF The rated diversity factor is covered in more detail. In practice it is assumed that multiple functional units are not fully loaded simultaneously. (see also FAQ chapter) Labels Labels have to be subjected to testing to verify their legibility. The following information is required on the label: ASSEMBLY Manufacturer s name Identification number Date of manufacture (NEW!) IEC 61439-X (the specific part X has to be specified) (NEW!) Grey areas A number of grey areas have been clarified: neutral conductors will have a current rating equal to 50% of the corresponding phases if not otherwise specified agreements between Customer and Manufacturer have been more detailed, extended and listed in annex C it is mandatory to specify the rated current of the ASSEMBLY a technical report IEC 61439-0 Guide for specifying ASSEMBLIES is under development for a better understanding of the new standard questions regarding the internal form of separation have been clarified (e.g. a moulded case circuit breaker s casing provides separation from other functional units) Summary table with the main changes IEC 60439 IEC 61439 IEC 60439-1 IEC 61439-2 Type-tested and partially type-tested assemblies Design verified ASSEMBLIES Mix of different rules and demands in each part Clear structure: IEC 61439-1 General rules IEC 61439-2 -6 Subsidiary parts (product standard) Each part is a complete entity and can be used on an individual basis Each subsidiary part is based on the general rules (Part 1) and includes only the specific additional rules for the specific product Testing each type of assembly: Three alternative methods for verification: Partially type-tested or type-tested Test, calculation/measurement, design rules Annex E: Annex C: Agreements between Customer and Manufacturer Agreements between Customer and Manufacturer are more detailed and extended Shared responsibility: Original Manufacturer vs. ASSEMBLY Manufacturer Technical changes and clarifications: Diversity factor, verification of temperature rise, mechanical characteristics, neutral conductor 50%, additional verification (from IEC 62208) IEC 61439 The new standard 11

Responsibilities With regard to responsibilities, the general and obvious rule is: the manufacturer of the ASSEMBLY is responsible for the ASSEMBLY! For a better explanation of this concept we can say: the Original Manufacturer usually makes design verifications and assumes responsibility for the proper functionality of prototype ASSEMBLIES. He provides a portfolio of verified ASSEMBLIES and each actor in the electrical market, who becomes the ASSEMBLY Manufacturer, can manufacture a design verified ASSEMBLY by following the instructions supplied in the Original Manufacturer s instruction manual or catalogue; the ASSEMBLY Manufacturer assumes responsibility for the ASSEMBLY, he labels the ASSEMBLY and it is his responsibility to declare that the ASSEMBLY complies with the relevant standards. In practice he has two options: he decides to manufacture the ASSEMBLY according to the rules of the Original Manufacturer. In this case, the ASSEMBLY Manufacturer has to perform only the second stage verification, namely routine verification. he decides NOT to manufacture the ASSEMBLY according to the rules of the Original Manufacturer. In this case, the ASSEMBLY Manufacturer incorporates his own arrangements, so that he is deemed to be the Original Manufacturer. Regarding these arrangements and he must then carry out both the first and the second stage verification: design verification and routine verification. Some hypothetical examples: An Original Manufacturer (e.g. ABB) assembles a complete ASSEMBLY and sells it to a panel builder the panel builder is only the ASSEMBLY Manufacturer, if he installs the ASSEMBLY as it is. the panel builder is the ASSEMBLY Manufacturer and becomes the Original Manufacturer if he makes some modifications to the ASSEMBLY. A panel builder assembles a complete ASSEMBLY (according to the rules of the Original manufacturer) the panelbuilder is the ASSEMBLY Manufacturer and is responsible for the ASSEMBLY, providing the electrical installer installs the ASSEMBLY without making any alterations. A panel builder assembles a complete ASSEMBLY (according to the rules of the Original manufacturer) that has been partially assembled by an external supplier the panel builder is the ASSEMBLY Manufacturer and is responsible for the ASSEMBLY. 12 IEC 61439 The new standard

IEC 61439 The new standard 13

FAQ Until what point is it possible to manufacture and to install ASSEMBLIES in accordance with IEC 60439? The validity of the two standards will overlap until 2014 and prior to this date, ASSEMBLIES can be manufactured according to IEC 61439 or IEC 60439. If tests on the ASSEMBLY have been conducted in accordance with IEC 60439, is it necessary to repeat them in accordance with the new IEC 61439? No, if the conducted test results fulfil the requirements of the new IEC 61439 it is not necessary to repeat them. It is necessary to test only the additional verification that has been introduced by the new standard. Is it possible to manufacture an ASSEMBLY in accordance with the new IEC 61439, with enclosures from ABB, busbars from another manufacturer, circuit breakers from another manufacturer, etc.? Yes, it is possible but it is not easy and it is expensive. The panel builder that decides to mix different elements from different manufacturers is not only the ASSEMBLY Manufacturer, but becomes the Original Manufacturer and has to perform both the first and the second stage verification: design verification and routine verification. The routine verification is similar to the present routine test and is relatively straightforward. The design verification however includes some characteristics which are easily verified, and others that can only be verified through laboratory testing. What is the Rated Diversity Factor (RDF)? The RDF is the per unit value of the rated current, to which outgoing circuits of an ASSEMBLY can be continuously and simultaneously loaded (the mutual thermal influences have to be taken into account). It can be declared for groups of circuits or for the whole ASSEMBLY. The RDF has to be assigned by the ASSEMBLY Manufacturer (if not specified it is assumed to be equal to 1). In practice it is recognised that not all circuits in an ASSEMBLY operate at rated current continuously and this allows efficient use of materials and resources. Is it possible to substitute a device within an ASSEMBLY? What about temperature rise and short circuit strength? The new IEC 61439 clearly defines a device substitution in respect of temperature rise and short circuit strength. Temperature rise: it is possible to substitute a device without repeating the design verification, provided that the new device from the same or another series has identical or better values, regarding power loss and terminal temperature rise, in comparison with those of the original device, as tested in accordance with the product standard. Short circuit: it is possible to substitute a device without repeating the design verification, provided that the new device is identical. If different, it has to be from the same manufacturer who has to certify that it is equivalent or better with regard to all relevant short circuit characteristics. Is the verification of the short circuit withstand strength required for all circuits of an ASSEMBLY? No, it is not required for: An ASSEMBLY having a rated short-time withstand current or rated conditional short circuit current not exceeding 10 ka r.m.s. An ASSEMBLY protected by current-limiting devices having a cut-off current not exceeding 17 ka at the maximum permitted prospective short-circuit current at the terminals of the incoming circuit of the ASSEMBLY. Auxillary circuits of an ASSEMBLY intended to be connected to transformers whose rated power does not exceed 10 kva for a rated secondary voltage of not less than 110 V, or 1.6 kva for a rated secondary voltage less than 110 V, and whose short circuit impedance is not less than 4%. All other circuits have to be verified. 14 IEC 61439 The new standard

Does the verification of temperature rise remain unchanged? Temperature rise requirements have been explained in further detail. Three different methods are now allowed for verification (the Original Manufacturer is responsible for choosing the suitable verification methods): 1) Testing with current: Three different test methods are permitted and the Original Manufacturer has to determine the best method. When a number of variants of an ASSEMBLY have to be verified, the most onerous configuration has to be tested and the ratings of the less onerous (and similar) variants can be derived without testing. 2) Derivation: (from a tested design) of ratings for similar variants The standard defines a series of sub-clauses that help define, how non-tested variants can be verified by derivation from similar arrangements verified by test. 3) Calculation: two calculation methods are allowed Single compartment ASSEMBLY with rated current not exceeding 630 A (done by calculating the total power loss of the ASSEMBLY if certain conditions are fulfilled). Multiple compartment ASSEMBLY with rated current not exceeding 1600 A (done by calculation in accordance with the method of IEC 60890 if certain conditions are fulfilled). Flow chart to establish how to verify the temperature rise I na 630 A Yes Single compartment? Yes No No I na 1600 A Yes No Are the IEC 61439 and IEC 60890 conditions fulfilled? Yes Are the IEC 61439 conditions fulfilled? No No Yes Testing with current OR derivation (if a tested prototype is available) Calculation in accordance with IEC 60890 Calculation of the total power loss IEC 61439 The new standard 15

Summary and conclusion The new standard IEC 61439 introduces important modifications in comparison with the current standard IEC 60439 on low-voltage switchgear and controlgear ASSEMBLIES. The structure of the new standard is clearer with a general part and product specific parts. New definitions have been written (e.g. Original Manufacturer and ASSEMBLY Manufacturer ). New compulsory characteristics have to be specified (e.g. rated current of the ASSEMBLY). A new design verified ASSEMBLY concept has been specified. This new concept completely discards the categories TTA and PTTA, and the compliance of an ASSEMBLY can now not only be verified by means of tests, but also with alternative methods: calculation/measurement and design rules. The new standard is more precise, eradicating the grey areas contained in the previous standard. The responsibilities for an ASSEMBLY are clearly defined, making the job of each actor on the electrical market easier nowadays. 16 IEC 61439 The new standard

Notes 18 IEC 61439 The new standard

Contact us You can find the address of your local sales organisation on the ABB homepage: www.abb.com/contacts > Low Voltage Products and Systems Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 2010 ABB All rights reserved K-0119-KM-11/2010-V1 2CPC 000 119 L0201