HeartStart MRx and XL AED Algorithm

Similar documents
Arrhythmia Monitoring Algorithm

QRS Complexes. Fast & Easy ECGs A Self-Paced Learning Program

ACLS RHYTHM TEST. 2. A 74-year-old woman with chest pain. Blood pressure 192/90 and rates her pain 9/10.

By the end of this continuing education module the clinician will be able to:

MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

PRO-CPR Guidelines: PALS Algorithm Overview. (Non-AHA supplementary precourse material)

Improving ECG Quality

Tachyarrhythmias (fast heart rhythms)

NEONATAL & PEDIATRIC ECG BASICS RHYTHM INTERPRETATION

the basics Perfect Heart Institue, Piyavate Hospital

Introduction. Planned surgical procedures

Innovative solutions in resuscitation therapy

SUMMARY. Additional Digital/Software filters are included in Chart and filter the data after it has been sampled and recorded by the PowerLab.

BASIC CARDIAC ARRHYTHMIAS Revised 10/2001

ECG Filtering. Willem Einthoven s EKG machine, 1903

INTRODUCTORY GUIDE TO IDENTIFYING ECG IRREGULARITIES

Feature Vector Selection for Automatic Classification of ECG Arrhythmias

ACLS Provider Manual Comparison Sheet Based on 2010 AHA Guidelines for CPR and ECC. BLS Changes

Understanding the Electrocardiogram. David C. Kasarda M.D. FAAEM St. Luke s Hospital, Bethlehem

Electrophysiology Heart Study - EPS -

HTEC 91. Topic for Today: Atrial Rhythms. NSR with PAC. Nonconducted PAC. Nonconducted PAC. Premature Atrial Contractions (PACs)

HOW TO USE THE LIFEPAK 1000 DEFIBRILLATOR 3

The new generation in ECG interpretation

Streamlining Case Management Workflow

1 Meet Your AliveCor Heart Monitor

Normal Sinus Rhythm. Sinus Bradycardia. Sinus Tachycardia. Rhythm ECG Characteristics Example (NSR) & consistent. & consistent.

Atrial & Junctional Dysrhythmias

Detecting Atrial-ventricular blocks Arrhythmia based on RR-intervals on ECG Signals

GUIDELINE 11.9 MANAGING ACUTE DYSRHYTHMIAS. (To be read in conjunction with Guideline 11.7 Post-Resuscitation Therapy in Adult Advanced Life Support)

Introduction to Electrocardiography. The Genesis and Conduction of Cardiac Rhythm

Basics of Pacing. Ruth Hickling, RN-BSN Tasha Conley, RN-BSN

What Are Arrhythmias?

ACLS Study Guide BLS Overview CAB

RAPID INTERPRETATION OF. EKG s

R Series Quick Reference Guide

Efficient Heart Rate Monitoring

Patient Information Sheet Electrophysiological study

Introduction to Electrophysiology. Wm. W. Barrington, MD, FACC University of Pittsburgh Medical Center

VCA Veterinary Specialty Center of Seattle

Ready to save lives. Philips HeartStart XL+ Defibrillator/Monitor

Catheter Ablation. A Guided Approach for Treating Atrial Arrhythmias

Management of Pacing Wires After Cardiac Surgery

Electrocardiography I Laboratory

HEARTSTART MRx MONITOR/DEFIBRILLATOR

HEARTSTART XL DEFIBRILLATOR/MONITOR Model: M4735A PRODUCT DESCRIPTION

Evaluation copy. Analyzing the Heart with EKG. Computer

IU Health ACLS Study Guide

2015 Interim Resources for BLS

Activity 4.2.3: EKG. Introduction. Equipment. Procedure

The Electrocardiogram (ECG)

Signal-averaged electrocardiography late potentials

Diagnosis Code Crosswalk : ICD-9-CM to ICD-10-CM Cardiac Rhythm and Heart Failure Diagnoses

Philips PageWriter Touch ECG System

Pacemakers 12/04. Pacemakers. 1. What is a pacemaker?

510(k) Summary May 7, 2012

HEART HEALTH WEEK 3 SUPPLEMENT. A Beginner s Guide to Cardiovascular Disease HEART FAILURE. Relatively mild, symptoms with intense exercise

Electrophysiology Daymar College. Lisa H. Young, RN, BSN, MAE 2011

The science of medicine. The compassion to heal.

«Δυσλειτουργία βηματοδότη. Πως μπορούμε να την εκτιμήσουμε στο ιατρείο.» Koσσυβάκης Χάρης Καρδιολογικό Τμήμα Γ.Ν.Α. «Γ. ΓΕΝΝΗΜΑΤΑΣ

Interpreting a rhythm strip

Power to see the big picture

Detection of Heart Diseases by Mathematical Artificial Intelligence Algorithm Using Phonocardiogram Signals

EMS SKILL CARDIAC EMERGENCY: AUTOMATED EXTERNAL DEFIBRILLATION (AED)

Wide-Complex Tachycardias in the ED: Myths and Pitfalls

Current Management of Atrial Fibrillation DISCLOSURES. Heart Beat Anatomy. I have no financial conflicts to disclose

The choice for quality ECG arrhythmia monitoring

CCAD Training Manual. Cardiac Rhythm Management (CRM)

Ready to save lives. Philips HeartStart XL+ Defibrillator/Monitor

American Heart Association ACLS Pre-Course Self Assessment Dec., ECG Analysis. Name the following rhythms from the list below:

ACLS PHARMACOLOGY 2011 Guidelines

Guidance for Industry and FDA Staff. Class II Special Controls Guidance Document: Arrhythmia Detector and Alarm

Department of Emergency and Disaster Medicine Medical University of LODZ

ACLS Defibrillation Protocols With the ZOLL Rectilinear Biphasic Waveform AHA/ERC Guidelines 2005

Electrodes placed on the body s surface can detect electrical activity, APPLIED ANATOMY AND PHYSIOLOGY. Circulatory system

8 Peri-arrest arrhythmias

ST Segment Monitoring. IntelliVue Patient Monitor and Information Center, Application Note

School of Health Sciences

Connected Care. Philips HeartStart connectivity and data management for EMS professionals

About the British Heart Foundation

ACLS Chapter 3 Rhythm Review Instructor Lesson Plan to Accompany ACLS Study Guide 3e

HeartStart FR3 Defibrillator TECHNICAL REFERENCE MANUAL

The abbreviation EKG, for electrocardiogram,

2 Review of ECG Analysis

An Introduction to Tachyarrhythmias R. A. Seyon MN, NP, CCN(C) & Dr. R. G. Williams

Team Leader. Ensures high-quality CPR at all times Assigns team member roles Ensures that team members perform well. Bradycardia Management

For those who get there first. Philips HeartStart FRx Defibrillator product information

Question-and-Answer Document 2010 AHA Guidelines for CPR & ECC As of October 18, 2010

BIPOLAR LIMB LEADS UNIPOLAR LIMB LEADS PRECORDIAL (UNIPOLAR) LEADS VIEW OF EACH LEAD INDICATIVE ECG CHANGES

The Patient s Guide to the Electrophysiologic Study (EPS) and Catheter Ablation

SW012. Installation software for the Right Ventricular Lead Integrity Alert feature. Reference Manual

Always in touch. Philips PageWriter TC50 cardiograph

Present : PGY 王 淳 峻 Supervisor: F1 王 德 皓

Expand your view. IntelliVue MX600, MX700, and MX800 bedside patient monitors

HeartStart HS1 Defibrillators TECHNICAL REFERENCE MANUAL

Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19

Equine Cardiovascular Disease

Rigel 333 Multi Parameter Patient Simulator Version 2.0

2 ECG basics. Leads and planes. Leads. Planes. from different perspectives, which are called leads and planes.

Cardiac Arrest VF/Pulseless VT Learning Station Checklist

Banner Staff Service ECG Study Guide

Transcription:

HeartStart MRx and XL AED Algorithm Application te Introduction HeartStart MRx and XL Defibrillator/Monitors offer automatic external defibrillation (AED) mode. AED mode can be used to analyze a patient s ECG and determine if a shock is advised. Analysis is performed by internal microprocessors that use an algorithm to interpret the heart s electrical signals. Life-threatening arrhythmias are quickly and accurately detected, and the correct therapy is recommended. This application note explains how the computerized AED algorithm successfully filters artifact and accurately identifies features of morphology associated with shockable rhythms. It also describes which rhythms are considered shockable and discusses the algorithm s effectiveness.

HeartStart MRx and XL AED Algorithm What is an Algorithm? An algorithm is a sophisticated, mathematical process of interpreting information. In AED mode, the HeartStart MRx and XL defibrillator/monitors use an algorithm to interpret electrical signals received from the patient s heart, via multifunction defib electrode pads. The algorithm determines if the patient has a life-threatening arrhythmia and makes a shock/no-shock decision. An algorithm is a crucial factor in the safety and performance of an AED. The algorithm must accurately assess the cardiac state of a patient and make an appropriate therapy recommendation. Algorithm performance is evaluated on two criteria sensitivity and specificity. Sensitivity refers to the device s ability to detect life-threatening ventricular arrhythmias. Specificity refers to the device s ability to detect normal rhythms or arrhythmias that should not be shocked. AED Algorithm Components The HeartStart MRx/XL AED algorithm is comprised of three components, as shown in Figure : Data acquisition and signal conditioning Feature extraction Rhythm classification These components work together to produce an algorithm that is highly sensitive to shockable rhythms and highly specific to nonshockable rhythms. The data acquisition and signal conditioning component acquires the ECG signal and removes unwanted artifact. This clean ECG signal is then passed on to the feature extraction component. The feature extraction component yields measurements of the various rhythm characteristics that are used to differentiate between shockable and non-shockable rhythms. Finally, the rhythm classification component of the algorithm uses these measurements to produce a shock/no-shock decision. Figure AED Algorithm Components Patient Data Acquisition and Signal Conditioning Feature Extraction Rhythm Classification 5/6 Hz AC line filter 2 Hz lowpass filter 2 Hz highpass filter pads on/off detection QRS detection heart rate computation QRS morphology measurements waveform amplitude measurements waveform slope measurements rhythm regularity waveform organization rhythm rate 2

AED Algorithm Components Data Acquisition and Signal Conditioning The patient s ECG is acquired through the multifunction defib electrode pads that are attached to the patient s chest (anterior-anterior placement). The signal is digitized and processed to remove or reduce the effects of certain types of electrical interference, often referred to as artifact or noise. In addition, impedance between pads is monitored to detect conditions that could compromise the algorithm s results. The goal of this signal conditioning is to provide the feature extraction component with a signal that is a clean representation of the patient s ECG a signal that is free of artifact. What is Artifact? Artifact is an electrical signal present in the ECG that is unrelated to the heart s signal. If artifact is not removed or sufficiently reduced, it can cause an incorrect analysis of the patient s heart rhythm, leading to an inappropriate shock/no-shock decision. Sources of artifact can be characterized as either controllable or uncontrollable by the clinician. Directly touching the electrode pads, moving the patient, and transport are examples of artifact that can be controlled. Conversely, electrical interference, muscle tremor, and patient movement are sources of artifact that are generally not within the control of the clinician. The HeartStart MRx/XL AED algorithm detects artifact and handles it in several ways. If the artifact corrupts the ECG to the point that analysis is compromised, the clinician is directed to the source of the problem and prompted with the appropriate corrective action. Otherwise, the ECG signal is passed through a number of filters that remove or attenuate artifact. Filters Several filters help to remove common types of interference caused by sources such as AC power, and muscle tremor. AC power line interference may contaminate the ECG with a 5 or 6 Hz signal. This interference is attenuated by a narrow stopband filter called a notch filter, which is tuned to remove the 5 or 6 Hz signals and higher harmonics. A 2 Hz high-pass filter is used to reduce low-frequency baseline wander that can be caused by pad offset drift or patient movements. Muscle tremor may contaminate the ECG with high-frequency baseline noise. A low-pass filter can remove much of the noise. Unfortunately, the frequency spectrum overlaps the ECG frequency, so it is not possible to remove all of it without destroying ECG data. The AED algorithm applies a 2 Hz low-pass filter to minimize artifact from muscle tremor. Impedance Monitoring By monitoring the impedance between the electrodes, the HeartStart MRx/XL AED algorithm can detect conditions that could compromise the algorithm s results. For example, a pad that is not making good contact with the patient interferes with ECG data acquisition. The impedance data in this case suddenly changes to very high values and back again. Similarly, when a pad comes off completely, the impedance data suddenly changes. The AED algorithm monitors the impedance data for this type of change and alerts the responder to reattach pads, if necessary. Feature Extraction Shockable rhythms have certain characteristics that can be used to distinguish them from non-shockable rhythms. The feature extraction component of the HeartStart MRx/XL AED algorithm measures these key characteristics and provides the measurements to the rhythm classification component of the algorithm. Some rhythm types may have a single measurement that is good at distinguishing that rhythm from all others. Other rhythms require a number of measurements to finally distinguish the rhythm. The features that are measured can be grouped into two categories: beat features and rhythm features. Beat features are associated with the detection of a QRS complex. QRS morphology features are used to characterize the relative organization of the waveform. A rhythm is deemed organized if there are recurring QRS complexes of a similar morphology. The rate of QRS detection, heart rate, is a feature primarily used to decide when wide complex tachycardia is shockable. Rhythm features measure properties of the waveform unrelated to the QRS beats. These features are particularly useful for rhythm types that do not contain true QRS complexes, such as asystole and ventricular 3

HeartStart MRx and XL AED Algorithm fibrillation. Rhythm features include average waveform amplitude, measures of isoelectric baseline content, waveform rate, and waveform rhythm regularity. All of these features are combined in the rhythm classifier to yield the final shock/no-shock decision. Rhythm Classification The rhythm classification component of the algorithm combines the many measurements acquired during feature extraction into a single binary decision: shock or no-shock. To do this successfully, the algorithm must distinguish between a wide variety of ECG rhythms. Figure 2 shows the criteria used to make this decision. Refer to Table for rhythm classification labels. First, the average waveform amplitude is used to identify very small rhythms, such as asystole and agonal rhythms, as nonshockable. Then, isoelectric baseline content is used to identify narrow QRS-complex or slow rhythms as non-shockable. Finally, QRS morphology features are used to identify rhythms which are organized or disorganized. For the disorganized rhythms such as ventricular fibrillation and agonal rhythm, measures of waveform rate and regularity help distinguish slow, wide-complex nonshockable rhythms from fast, wide-complex shockable rhythms. Organized rhythms such as monomorphic ventricular tachycardia and other wide-qrs tachycardias of unknown origin are then deemed shockable if their QRS rate is greater than 5 beats per minute. Figure 2 Rhythm Classification shock Asys, AR shock Narrow-complex NS, SVT, Slow IdioV Yes Yes ➀ ➁ Average amplitude small? Isoelectric baseline content large? ➂ Organized rhythm? Yes Shock Yes Waveform rate high? shock VF, PVT, FVF AR Shock Yes Heart rate > 5 bpm? shock MVT>5 NSW, IdioV, AR, MVT<5 SVTa<5 4

Rhythm Classifications Rhythm Classifications Table summarizes the key criteria used by the HeartStart MRx/XL AED algorithm to classify a rhythm as shockable or non-shockable. Table Rhythm Classifications Label a Rhythm Criteria Shock Classification VF Ventricular Fibrillation amplitude >.2 Shockable FVF Fine Ventricular Fibrillation. < amplitude <.2 Shockable MVT, PVT SVTa Ventricular Tachycardia (Monomorphic or Polymorphic) Supraventricular Tachycardia with Aberrant Conduction QRS > 2 ms, ventricular or unknown origin: rate > 5 bpm rate < 5 bpm b QRS > 2 ms, supraventricular origin IdioV Idioventricular Rhythm QRS > 2 ms, ventricular origin, rate < bpm NSW Other n-shockable Rhythms with Wide QRS QRS > 2 ms, unknown or supraventricular origin, rate < bpm Shockable t Shockable t Shockable t Shockable t Shockable Asys Asystole amplitude <. t Shockable AR Agonal Rhythm rate < 2 bpm t Shockable SVT Supraventricular Tachycardia QRS < 2 ms, rate > t Shockable with Narrow QRS bpm, supraventricular origin AFF Atrial Fibrillation or Flutter atrial fib, or flutter waves, t Shockable irregular rhythm VER Ventricular Ectopic Rhythm frequent ventricular ectopics t Shockable BLK Blocked Rhythm AV or bundle branch block rhythms t Shockable NS Other n-shockable Rhythms with Narrow QRS QRS < 2 ms, unknown or supraventricular origin, rate < bpm t Shockable Paced Paced Rhythm t Shockable a. The rhythm labels shown are for algorithm classification purposes only. b. Polymorphic Ventricular Tachycardia may be treated as VF and shocked. 5

HeartStart MRx and XL AED Algorithm Ventricular Fibrillation Ventricular fibrillation (VF) is the most common cardiac arrest rhythm that can be terminated by a defibrillation shock. When VF is present, the heart cannot pump blood to the rest of the body. A patient with VF has no pulse, and the ECG is rapid and irregular with no QRS complexes. Coarse VF has an amplitude greater than.2. Fine VF has an amplitude between. and.2. Below., the algorithm recognizes the rhythm as asystole. Shock is advised for VF. Fine VF and asystole can sometimes be difficult to differentiate. Asystole is not a shockable rhythm (see the Asystole tion). Figure 3 - Coarse Ventricular Fibrillation Ventricular Tachycardia Ventricular tachycardia (VT) consists of three or more ventricular beats at a rate of more than beats per minute (bpm). The QRS complexes are wide greater than 2 ms and may be of a single morphology (monomorphic VT) or of several morphologies (polymorphic VT). Ventricular tachycardia with a rate greater than 5 bpm and sustained for six onds is shockable. Some very irregular forms of polymorphic VT are treated like VF and are shockable regardless of rate. Assuming that the victim has no pulse (which is a condition for using the HeartStart MRx AED algorithm), VT may be treated with unsynchronized shocks. Wide QRS tachycardia of unknown origin with a rate greater than 5 bpm and sustained for six onds is also shockable. Clinicians sometimes find it difficult to distinguish VT from other wide-qrs tachycardias of unknown origin, and the same treatment is advised for both. Figure 5 Monomorphic Ventricular Tachycardia Figure 4 Fine Ventricular Fibrillation - - Figure 6 Polymorphic Ventricular Tachycardia Shock classification: Ventricular fibrillation is a shockable rhythm. - Shock classification: Ventricular tachycardia and wide-qrs tachycardia of unknown origin with a rate greater than 5 bpm is shockable. VT with a rate less than 5 bpm is not shockable. 6

Rhythm Classifications Supraventricular Tachycardia with Aberrant Conduction A rhythm originating above the ventricles with aberrant conduction and at a rate greater than bpm is known as supraventricular tachycardia with aberrancy (SVTa). Wide QRS complexes result from abnormal conduction paths within the ventricles. Figure 7 Supraventricular Tachycardia with Aberrant Conduction Wide-Complex Idioventricular Rhythms Wide ventricular beats, greater than 2 ms, at a rate of less than bpm, often occur as a post-defibrillationshock escape rhythm. This is not a shockable rhythm. Figure 9 Idioventricular Rhythms - - Shock classification: Wide-complex idioventricular rhythms are not shockable. Shock classification: SVTa is not shockable. Asystole Ventricular asystole is the absence of ventricular depolarization and contraction. Interpreters of the ECG may have some difficulty distinguishing between asystole and fine VF. The algorithm defines asystole as a rhythm with an average amplitude less than.. A person with asystole has no pulse and should not be shocked because shocks can inhibit any natural pacemakers. Figure 8 Asystole Other n-shockable Rhythms Many rhythms exist for which a shock is not indicated. Some of these rhythms are not associated with cardiac arrest or will respond adversely. Such rhythms include: supraventricular tachycardia with narrow QRS morphology atrial fibrillation and flutter sinus rhythms rhythms with frequent PVCs blocked rhythms junctional rhythms paced rhythms - Shock classification: Asystole is not shockable. Transitional Rhythms If the ECG changes from a non-shockable rhythm to a shockable rhythm, the algorithm's response may vary, depending upon how quickly the change occurred, how much of the shockable rhythm is included in the analyzed data, and the nature of the rhythms. 7

HeartStart MRx and XL AED Algorithm Clinical Performance The algorithm was developed and validated using two large databases of ECG rhythms made up of data from 564 patients. The data was from two sources. One was created from tapes of primarily pre-hospital usages of AEDs. The other was collected using a CodeMaster XL+ defibrillator monitor with special software installed to record and save patient ECG data. This data was collected in a variety of clinical settings, both in and out of hospital. ECG rhythms were annotated by clinical experts according to the classifications shown in Table Rhythm Classifications on page 5. All of the data was split in half into a training and a testing database. The training data was used to develop the algorithm. The testing data was used to validate the algorithm s performance, and was not used for development. There were 2337 total ECG strips in the testing database. The results on the testing data are shown in Tables 2 and 3. Table 2 Shockable Rhythm Data Rhythm Category Sensitivity Analyzed Strips # Ventricular Fibrillation 97% 33 amplitude >.2 Fine Ventricular Fibrillation 76% 96. < ampl. <.2 Ventricular Tachycardia 84% 43 rate 5 bpm Total 452 The overall sensitivity is 9%. Table 3 n-shockable Rhythm Data Performance Parameters The following four parameters were used to assess the algorithm s performance: A true positive (A) is a shockable rhythm associated with cardiac arrest that is classified as a shockable rhythm/condition. A false positive (B) is an organized or perfusing non-shockable rhythm that has been incorrectly classified as a shockable rhythm/condition. A false negative (C) is a shockable rhythm associated with cardiac arrest that has been classified as a non-shockable rhythm/condition. A true negative (D) is any non-shockable rhythm that is classified as a non-shockable rhythm/condition. Calculating Sensitivity and Specificity The sensitivity of the device is the number of true positive shockable rhythms, expressed as a percentage of the total number of shockable rhythms: A sensitivity = % A ------------- + C The specificity is the number of organized or perfusing rhythms that have been correctly classified as non-shockable rhythms/conditions by the algorithm, and is expressed as a percentage of the total number of non-shockable rhythms/conditions: D specificity = % B ------------- + D Rhythm Category Specificity Analyzed Strips # Asystole /Agonal 96% 395 Ventricular Tachycardia 88% 26 bpm < rate < 5 bpm Idioventricular 95% 438 All Other n-shockable % 846 Rhythms Total 885 The overall specificity is 96%. 8

AED Algorithm Safety AED Algorithm Safety The HeartStart MRx/XL AED mode includes the following measures to ensure operator and patient safety: development in accordance with ANSI/AAMI Standard DF39-/93 does not shock automatically provides user with -3 step defibrillation easy-to-read messages and error tones alert the user to possible problems recorder strips are provided for medical records It is important to note that the algorithm is not designed to handle erratic spiking problems caused by a pacemaker, or to detect pediatric cardiac arrhythmias. NOTE: Prior to using the HeartStart MRx or XL ALS defibrillator/monitor, review the indications for use defined in the Instructions for Use. 9

HeartStart MRx and XL AED Algorithm Philips Healthcare is part of Royal Philips Electronics On the web www.philips.com/heartstart By e-mail healthcare@philips.com By postal service Philips Healthcare 3 Minuteman Road Andover, MA 8-85 Europe, Asia, and Africa Tel: +49 73 463 2254 Latin America Tel: +55 225 744 rth America Tel: +425 487 7 8 285 5585 (USA only) 2 Koninklijke Philips Electronics N.V. All rights are reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright holder. Philips Healthcare reserves the right to make changes in specifications or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. Published July 2, Edition 2 Printed in the USA 453564976 *453564976* *2*