Static UPS Topology 101

Similar documents
Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

Power Quality. Uninterruptible Power Supply

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

The Different Types of UPS Systems

The Different Types of UPS Systems

NO-BREAK KS 7e. Concentrated Energy kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM

The Different Types of UPS Systems

A COMPARISON OF TYPICAL UNINTERRUPTIBLE POWER SUPPLY (UPS) DESIGNS IN TODAY S MARKETS

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Line Reactors and AC Drives

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

Product Data Bulletin

Power surges can also be generated by equipment in your facility such as:

Selecting a UPS Topology for your Data Center. by Dr. Daniel Becker, Ph.D., Methode Active Energy Solutions

GE Digital Energy. TLE Series UPS kw three phase 400 Vac. with best-in-class efficiency. gimagination at work

Thyristor-controlled power supplies and battery chargers

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Power Quality Issues, Impacts, and Mitigation for Industrial Customers

Technical Comparison of On-line vs. Line-interactive UPS designs

Principles of Adjustable Frequency Drives

The Facts About Harmonics and Power Factor. Power Quality: Harmonics & Power Factor Correction

TLE Series UPS kva/kw three phase 400 Vac with best-in-class efficiency

POWER SYSTEM HARMONICS. A Reference Guide to Causes, Effects and Corrective Measures AN ALLEN-BRADLEY SERIES OF ISSUES AND ANSWERS

Fundamentals of Power Electronics. Robert W. Erickson University of Colorado, Boulder

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Calculating Total Power Requirements for Data Centers

UPS Topologies & Architectures. Don Lemmon Tubbesing Solutions (214) don@tubbesing.com

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

Power Quality. Voltage Sag Ride-through Mitigation in Sequence by Increasing Cost

Working definitions of terms: Commercial vs. Industrial UPS Systems:

UPS Applications and VRLA Battery Sizing

A MULTILEVEL INVERTER FOR SYNCHRONIZING THE GRID WITH RENEWABLE ENERGY SOURCES BY IMPLEMENTING BATTERY CUM DC-DC CONERTER

ELECTRONIC POWER SYSTEMS

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Electrical Systems. <Presenter>

GLOLAB Two Wire Stepper Motor Positioner

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Introduction. Harmonics and IEEE 519 Page 1 of 19

Using the Phoenix MultiPlus

Fundamentals of Power

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

Improvements of Reliability of Micro Hydro Power Plants in Sri Lanka

CEMEP UPS. The high environmental performance solution for power supply to high-availability data centers

SG Series UPS kva three phase 400 Vac

COMPARISON OF THE FACTS EQUIPMENT OPERATION IN TRANSMISSION AND DISTRIBUTION SYSTEMS

Single Phase UPS Management, Maintenance, and Lifecycle

Eco-mode: Benefits and Risks of Energy-saving Modes of UPS Operation

VICOR WHITE PAPER. The Sine Amplitude Converter Topology Provides Superior Efficiency and Power Density in Intermediate Bus Architecture Applications

Contactless Power Transfer : Inductive charging of EV

CHAPTER 5 PHOTOVOLTAIC SYSTEM DESIGN

LAP ENERGIA PARA DATACENTERS

Specifying a Variable Frequency Drive s

Understanding Power Factor, Crest Factor, and Surge Factor. White Paper #17

HVDC-VSC: transmission technology of the future

Neutral Currents in Three Phase Wye Systems

Which UPS is right for the job?

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V V V (at 50 Hz)

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

How To Improve Power Quality

Triplen Harmonics Mitigation 3 Phase Four-Wire Electrical Distribution System Using Wye- Zig-Zag Transformers

Power System Harmonics

Design a Phase Interleaving PFC Buck Boost Converter to Improve the Power Factor

98% Efficient Single-Stage AC/DC Converter Topologies

DC GROUND FAULT DETECTION PROVIDED FOR UNINTERRUPTIBLE POWER SUPPLIES

A Practical Guide to Free Energy Devices

Renewable Energy Applications: Photovoltaic and Wind Energy Conversion Systems (WECS)

Three-Phase Electric Power Distribution for Computer Data Centers

LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE

New High Current MOSFET Module Offers 177 µω R DS(on)

7-41 POWER FACTOR CORRECTION

Understanding Delta Conversion Online "Output Power Factor Ratings" - Part 7

47000 SERIES - ELECTRONIC TRANSFORMERS

UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES

TOSHIBA G /100/160/225 kva

Yam Hong 施 耐 德 電 機 亞 太 日 本 區 (APJ) 三 相 關 鍵 電 源 市 場 開 發 經 理. Schneider Electric - Division - Name Date

Welcome to the Tripp Lite UPS Systems Basics training module, part of Tripp Lite's "Products Expert" training course Tripp Lite.

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

Objectives. Electric Current

ULRASONIC GENERATOR POWER CIRCUITRY. Will it fit on PC board

Considering the effects of UPS operation with leading power factor loads

Advanced Power Supply Topics

The Quest for Energy Efficiency. A White Paper from the experts in Business-Critical Continuity

Bourns Resistive Products

Maximizing UPS Availability

Low Cost Pure Sine Wave Solar Inverter Circuit

Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M

Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications

WIND TURBINE TECHNOLOGY

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

Five Nines and Infrared (IR) Testing at Data Centers

Power Supplies. 1.0 Power Supply Basics. Module

TOPOLOGIES FOR SWITCHED MODE POWER SUPPLIES

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

21 st Century Facilities

PowerGem Pro Uninterruptible Power Supply

Modified Cascaded Five Level Multilevel Inverter Using Hybrid Pulse Width Modulation

Intelligent Power Distribution in the Data Center

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

RIELLO ELETTRONICA. Master HP

Transcription:

Static UPS Topology 101 Double Conversion LINE INTERACTIVE CONVERSION Standby / Off- line By Robert J Walker Facility Gateway Corporation www.facilitygateway.com 1

Executive Summary UPS technology comes in many forms. The major technology differences start with either static UPS or rotary UPS. Within each of those categories there are multiple types of technology and significant differences in what the technology provides. One thing all systems called UPS have in common is some form of stored energy. For the sake of this paper please consider this an entry level understanding with a focus on Static technology UPS systems with some detailed information on the latest generation component advancements. Who we are Facility Gateway Corporation is not a manufacturer of any UPS systems; we specialize in Critical Infrastructure Data Center Design, Build, and Maintenance Asset Management Services. Our experience comes from working with many brands of UPS, Generator, Switchgear, HVAC and Monitoring equipment. We are product experts with a broad range of experience. Facility Gateway Corporation www.facilitygateway.com 2

Introduction Static UPS, the term Static refers to the use of semiconductor components that are used to convert power in a UPS back and forth between AC and DC power. Through the use of power electronics such as SCR s (Silicon Controlled Rectifiers) Transistors, and today IGBT (Isolated Gate Bipolar Transistor) we have seen this category of UPS become the dominant technology used in today s critical power applications. Due to the small foot print (which continues to shrink as technology advances) and the relative low cost these systems have proven to be very reliable, cost effective, and highly configurable. Facility Gateway Corporation www.facilitygateway.com 3

Single Phase & Three Phase power overview The two primary categories of Static UPS are defined by their application to either Single Phase Power or Three Phase Power. Single phase uses only 1 or 2 phases (legs) of power. Three phase indicating that 3 phases (legs) of power are used. The diagram below illustrates how we begin the selection of a UPS by first knowing the voltage. In addition to that the capacity of the system needs to be determined that value is published in kva & kw. It is important to know both values when selecting a UPS. Chart 1: Common Voltage Facility Gateway Corporation www.facilitygateway.com 4

Single Phase Single phase systems usually provide backup for electronic devices such as a work station, server, or telephone equipment, Single phase UPS systems range in size from 250va up to 22kVA Single phase systems vary in technology from standby, line interactive and double conversion L1 Hot Leg 120V Neutral 240V 120V L2 Hot Leg Fig 1. Typical Single Phase Panel board Fig 2. Typical Single Phase Transformer Output Facility Gateway Corporation www.facilitygateway.com 5

Three Phase Is generally more economical than one phase systems due to less conductor material used to transmit power Three phase systems typically fall in the range of 10kVA to 1MW modules that can be added in parallel to serve Multi- Mega Watt facilities The overwhelming majority of three phase systems are double conversion in technology These are the most common types of three phase power used at the UPS level. Fig 3. Typical Three Phase Wye used in America at 60 Hz. In many other countries this same configuration is used at different voltage levels. (430/250V 50 Hz, 420/240 V 50 Hz, 400/230 V 50 Hz & 380/220 V 50 Hz) Three Phase Wye Power 480/277V 60hz Three Phase Wye Power 208/120V 60hz 277V 120V 480V 480V 208V 208V 277V 120V 277V 480V 120V 208V Facility Gateway Corporation www.facilitygateway.com 6

Fig 4. Typical Three Phase Delta used in America at 60 Hz. 480V 208V 480V 208V 480V 208V 240V 120V 208V 240V Fig 5. Not as common but still found in many parts of the USA is the 240V Delta with a High Leg. Most of the time, it is found in older electrical installations. This is an odd one to find a three phase UPS for since most three phase UPS systems are 208V or 480V. 120V 240V Facility Gateway Corporation www.facilitygateway.com 7

Common Power Problems and Topology Basics Within the single phase & three phase static UPS market there are 3 primary categories of UPS technology. The categories of Standby, Line Interactive, & Double Conversion are shown below in this flow chart that give a brief illustration of the common applications each type of technology is used within. In addition the illustration show which of the 9 most common power problems are corrected by each type of technology. Chart 2: Static UPS Topology Facility Gateway Corporation www.facilitygateway.com 8

Standby or off line technology (Most common in single phase UPS) The transition to battery power actually has a momentary break. This technology is typically reserved for single phase UPS systems This sine wave in Fig 7, was captured from the output of 650va Back- Ups standby / off line UPS. This is the power you are feeding your equipment when you are on battery power Basic Solution: Protection from three potential problems. Fig 6. Standby One- line Fig 7. Modified sine wave Pros Inexpensive Good for home PC and non- critical power equipment Cons Short break in power 250m seconds or less Square wave form which could damage sensitive equipment Does not correct harmonic issues or frequency deviation Must use battery to compensate for sag Shorter battery life due to more discharges on the battery Only Metal Oxide Varistor is used to suppress surge conditions No static bypass Facility Gateway Corporation www.facilitygateway.com 9

Line interactive technology (Most common in single phase UPS) Moving forward to line interactive technology this is the next step up for better power protection. The key difference is that this technology has the ability to condition the output wave form without interruption to the power like the off- line technology does. This is done through a variety of technologies within this category of UPS. Most common is a buck boost bi- directional type of inverter/battery charger. This is the least expensive with the smallest foot print in this category. Line interactive technology provides additional power protection with the addition of two more problems that can be corrected for a total of 5 of the 9 power problems. Another technology worth mentioning in this category would be Ferro resonant UPS technology. While a Ferro unit is technically line interactive, it actually has the ability to correct all 9 power problems. The Ferro based UPS is able to correct all 9 power problems due to the Ferro resonant transformer in the UPS which inherently provides a 250 to 1 spike attenuation, harmonic correction, and very good voltage regulation without the use of the inverter. As a result, the batteries see less discharges and the inverter sees less hours of operation which help make this a very reliable system. This is a much larger foot print UPS and more expensive due to the large copper transformer. This technology is typically reserved for only single phase UPS systems. Fig 8. Line interactive one- line Fig 9. Line Interactive Output sine wave This Output Wave Form was captured from a Line Interactive 700VA UPS system Facility Gateway Corporation www.facilitygateway.com 10

Line interactive technology Basic Solution: Protection from five potential problems. Pros Cons Slightly better voltage regulations through use of a Buck/Boost Transformer Boosts under- voltage, and bucks down overvoltage If voltages exceed transformer capability, the UPS will use the battery to compensate for the condition Sine wave output Inexpensive Energy efficiency Battery life is shortened due to their correction of power issues when on- line There is typically no static bypass in most models Does not protect against Frequency deviation Line noise Transients Harmonic distortion Facility Gateway Corporation www.facilitygateway.com 11

Double conversion technology Double conversion technology is what most three phase UPS systems utilize along with your high end single phase UPS systems. The power is literally converted twice hence the name. The common components you will see in this technology regardless of brand name are the Rectifier, Inverter, and Static or Hybrid static bypass switch. Double conversion ensures that you have protection from all 9 of the most common power problems. Fig 10. Double conversion one- line In case of rectifier or inverter failure the static bypass will connect input power to the output Inside the UPS An alternate power path is used for maintenance & repairs (Typically external to the UPS so complete isolation of power can occur for full service access without powering loads down) Converts Incoming AC Power to DC Stored Energy Converts DC Power to AC Double Conversion Stored Facility Gateway Corporation www.facilitygateway.com 12

Double conversion technology Typical Wave Form output of the Double conversion UPS with high quality Pulse Width Modulation IGBT technology. Basic Solution: Protection from all nine five potential problems. Pros Equipment is isolated from all types of power problems Meets the 5% maximum harmonic requirement stated in major computer manufacturer specifications Uses the battery less than other UPS technology which increases the reliability and life of the batteries Cons Purchase cost is higher Efficiency lower than line Interactive (Historically) Facility Gateway Corporation www.facilitygateway.com 13

High Efficiency UPS technology In recent years the push for better energy efficiency in the data center has had an impact on UPS manufacturers. They have been coming up with creative ways to make their systems more energy efficient. This has led to some competing ideas and technologies that deserve an overview. Our company works with multiple UPS manufactures and we have had exposure to each of these competing technologies. There are 2 primary differences that can help you categorize these high efficiency UPS s. Energy Saver Mode One category is often referred to as some sort of energy saving mode that takes a conventional double conversion UPS and in layman s terms operates it as a line- interactive UPS. There are slight variations with each UPS manufacturer that offers this option on their UPS systems. Essentially incoming power is passed thru the UPS to the critical load with minimal surge suppression as long as the power is within the programmed input tolerance. When input power falls out of that window the unit turns the inverter on and in many cases pulls from the battery to correct the power issue. In the event of an actual power outage there can be up to a 2 or 4 microsecond delay for the inverter to come on. The theory is that most of these systems that utilize this technology do so at 480V and have transformers downstream of them. There should be enough residual power in those transformers that the loads never see the power transition. Some of these UPS s come with internal transformers and some are transformer- less. Efficiency claims are 98% to 99% depending on manufacturer. Transformer- less UPS with high efficiency double conversion The other direction taken by a few UPS manufacturers is their ability to build a more efficient double conversion UPS through better power electronics. This group of manufacturers has the luxury of also being some of the world s top semi- conductor manufacturers. As a result they have developed purpose built components for their UPS systems. Some of this technology has bled over from the Variable Frequency Drive market that has seen great strides in more energy efficient electric motors. The heart of the inverter on most UPS systems is the IGBT (Isolated Gate Bipolar Transistor). On your higher end UPS system this same component is also used on the rectifier of the UPS. The latest technology that a couple of UPS manufacturers utilize, is what they call the 5 th generation CST- IGBT (Carrier Storage Trench). This latest technology allows the UPS to have a High frequency Pulse Width Modulation wave form that is extremely well regulated without the energy losses associated with normal IGBT s. This allows the UPS to operate in normal double conversion mode providing all the protection that a UPS is installed for. It does this while maintaining 97% efficiency in the on- line double Facility Gateway Corporation www.facilitygateway.com 14

conversion mode. This system also has a very strong advantage in redundant designs since the UPS can achieve its highest efficiency with a partial load as low as 40%. Many tests have shown some models to achieve 93% efficiency all the way down to 15% partial load. Fig 12. 5 th Generation CST- IGBT UPS Performance Efficiency Plot 99.0% 97.0% 95.0% 93.0% 91.0% 225 kva 750 kva 89.0% 87.0% 85.0% 0% 20% 40% 60% 80% 100% 120% Typical SMS UPS operating load Typical MM UPS operating load Facility Gateway Corporation www.facilitygateway.com 15

CST- IGBT Transformer- less UPS Technology Benefits Smaller foot print 30% to 50% reduction in foot print over previous generation Less weight (floor loading concerns) Lower operating temperature & higher efficiency 30% to 45% in many cases vs. their transformer counter parts with older IGBT technology. Not only saves you money on UPS efficiency but reduces cooling cost associated with UPS. Full system efficiency achieved at 40% partial load with efficiencies remaining in the 94% range all the way down to 20% partial load. While operating in double conversion mode. Reduced parts count higher reliability <3% THD input 60%- 100% load <6% THD input at 25%- 59% load No input harmonic filter required Again lower parts count and less operating cost by eliminating capacitors that need to be replaced in the future. And lower energy cost due to low input THD 3 W + G install- reduce installation cost. Most all data centers use transformers closer to load already to provide step down to 208/120V 100% step load without the use of batteries Voltage Regulation +/- 1% for 0% to 100% Balanced Load, +/- 2% for 0% to 100% Unbalanced Load Facility Gateway Corporation www.facilitygateway.com 16

Conclusion It is a combination of needs and site limitations that ultimately dictate your UPS selection. This starts with identifying the loads and the value associated with keeping them protected. The type of load plays a big part in selecting the proper UPS technology. Within each of the categories we covered there were multiple differences between models. In this paper you were introduced to the difference between single phase and three phase UPS systems and the multitude of different voltage options. In addition to this the different UPS topologies were discussed and examples of common applications for each UPS type given. There were pro s and con s provided for each UPS technology and we dove into the latest in high efficiency designs. Last but not least, it is important to team up with an experienced partner during the selection and installation of a UPS system to ensure all critical aspects are considered. About the Author, Robert J Walker is the Senior Electrical Application Engineer for Facility Gateway Equipment Sales and Installation division. He is responsible for planning and design of data center critical power distribution, supporting the equipment sales team, critical facility management sales, turn- key installations and data center builds. He has 23 years of experience in power quality, power distribution and field service. His career in power quality began in 1990 at Best Power Technology, 1994 Rockwell Automation, 1996 Cooper Power Systems, 1999 Computer Power & Service Inc., 2006 JT Packard, 2011 Facility Gateway Corporation to present. His degree is in Electronic Engineering Technology from Herzing College (formerly Wisconsin School of Electronics). Additional courses from Milwaukee Area Technical College and Multiple UPS manufacturer s service school programs. Facility Gateway Corporation www.facilitygateway.com 17