Thermostatic Actuators

Similar documents
Thermostatic Actuators

Data sheet Thermostatic sensors type RA 2000

Butterfly Valves PN 6/10/16 for flanged connection

2- and 3-port valves with flanged connections, PN 10

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

THERMOSTATIC ACTUATORS WITH LIQUID-FILLED SENSITIVE ELEMENTS AND TEMPERATURE LOCKING

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

RRV934. Multi-controller. Synco living

Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity)

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

Thermostatic element RAVV for 2-way valves

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Thermostats. Technical information

Self-operated Temperature Regulators Temperature Regulator Type 1u

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Low-H2O valves Y EARS

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

Technical catalogue convectors POLAND 2012

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Automatic Bypass Control AVDO

HERZ-Thermal Actuators

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB

Radio controlled, programmable radiator thermostat RA PLUS-w

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

Flush-mount room temperature sensor AQR2531ANW.

Thermostatic valve Type AVTA

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

stainless steel pre-assembled manifolds

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

Room Temperature Sensors

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Automatic control equipment for HVAC systems

Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows

Radiator valve accessories

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Valve range. To be precise.

Digital inductive conductivity transmitter

Mikrotherm. Manual radiator valves. To be precise.

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Flush-mounted room thermostats

Data sheet ECC 12 and 22

Type 3353 Angle Seat Valve

Type overview. Technical data

Adjustable room thermostat for heating only or cooling only systems

Product and Application Description

Please refer to the chapters below for detailed information about all aspects of the products usage.

DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing

Infrarot-Bewegungsmelder IP44

Technical data. Danfoss DHP-A

User Manual THR840DUK Digital Thermostat

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Solenoid valves 2/2-way direct-operated Type EV210A

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Introduction. Angle/Flared/Sequence/Changeover Service Valves. Valves D

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

SWIMMING POOL HEAT PUMP Owners Manual

Actuator for modulating control AME 435

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

ECOplus Solar Cylinder

Assisted lift operated 2/2-way solenoid valves Type EV250B

SOLAR HEATING SYSTEMS.

Solenoid valves Type EVU

evohome Wireless Radiator Zoning Kit Installation & User Guide

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Electric Rotary Actuator - On/Off or programmable control actuator

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Digital input modules

Overview of types. Technical data

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Stainless Steel Single and Dual Circulation Kits

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Operating instructions Mechatronic flow sensor. SBY33x /06 03/2011

CALEFFI. SATK wall-mounted Heat Interface Unit - HIU Instantaneous domestic hot water production. SATK20 - SATK30 series 01209/13 GB

Radiant Temperature Sensor TY7321

Daikin Altherma hybrid heat pump. The natural combination

OZW30. Central Unit SYNERGYR

ECOCIAT. Domestic hot water heat recovery unit

Powers Controls TH 192 S Single Temperature Room Thermostat

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

Air damper actuators

VAV compact controller KNX / PL-Link

BB-18 Black Body High Vacuum System Technical Description

V47 Series Temperature Actuated Modulating Water Valves

REGULATORS 175/153 Series

Instruction Manual Differential Pressure Transmitter

KONRAD. Hybrid Fancoil Series

Installers and specifiers seeking information and advice on radiator thermostats and their application will find no better source than Danfoss.

Transcription:

2 111 EN 215-1 RTN51.. with remote sensor RTN81 with remote adjuster ACVATIX TM Thermostatic Actuators for radiator valves VDN.., VEN.., VUN.., VPD.. and VPE.. RTN51.. RTN81 Self-acting, without auxiliary power High-quality fluid-filled sensor with fast acquisition of room temperature changes Direct mounting with union nut, no tools required Robust construction, maintenance-free, noiseless operation Protection against dismantling (optional) RTN51.. white (matt or glossy) Use For use with Siemens radiator valves type VDN.., VEN.. and VUN.. For use with Siemens MiniCombiValves (MCV) type VPD.. and VPE.. For radiator valves supplied by Heimeier, Cazzaniga, Oventrop M30 x 1.5, Honeywell-Braukmann, MNG, Junkers and Beulco new (all without adapter) For radiator valves with actuators secured with an M30 x 1.5 union nut, nominal closing dimension 11.6 ± 0.3 mm and nominal stroke 1.5 mm (without adapter) With the appropriate AV adapters, the actuators can be used with valves from other manufacturers (refer to "Type summary / Accessories") CE1N2111en 30.09.2010 Building Technologies

Type summary Type reference RTN51 RTN51G RTN81 Description RAL 9016, glossy Version with remote sensor Version with remote adjuster Accessories Adapter type For valve makes Adapter type For valve makes AV52 Comap AV57 Herz AV53 Danfoss RA-N (RA2000) AV58 Oventrop < 2002 AV54 Danfoss RAVL AV59 Vaillant AV55 Danfoss RAV AV60 TA < 2002 AV56 Giacomini AV61 MMA Markaryd Type reference ATN2 Description Fitting to prevent dismantling of actuator Ordering Example: Product number Stock number Description Quantity RTN51 RTN51 Thermostatic actuator 6 AV57 AV57 Adapter 1 Delivery Rev. no. Valves and accessories are packed separately. See overview, page 7. Equipment combinations Valve type reference Description k vs V PN class Data Sheet [m 3 /h] [l/h] VDN.., VEN.., VUN.. Radiator valves 0.09 1.4 2105, 2106 PN10 VPD.., VPE.. MCV radiator valves 25 483 2185 For other radiator valves with type AV.. adapters, refer to «Type summary / Accessories» Radiator valves (M30 x 1.5) from other manufacturers, without adapter: Heimeier Honeywell-Braukmann Heimeier Cazzaniga MNG Cazzaniga Junkers Beulco new Oventrop M Oventrop M30 x 1,5 (since 2001) Honeywellk vs = Nominal flow rate of cold water (5 to 30 C) through the fully open valve (H 100 ) at a differential pressure of 100 kpa (1 bar) Technical design / mechanical design Mode of operation The fluid-filled sensor responds to deviations from the room temperature setpoint. When the room temperature rises, the fluid inside the metal capsule expands, exerting pressure on the bellows and the stem, which causes the valve to continuously close so that the radiator's heat output will be reduced. When the room temperature falls, the bellows expands, thereby opening the valve so that the radiator's output will be increased again. 2/8 This design allows the radiator valve to be continuously operated, thus achieving smooth regulation of the flow of heating water to the radiator, resulting in a constant room temperature in accordance with the room temperature setpoint.

RTN51.. 1 Fluid-filled sensor 2 Bellows 3 Overtravel mechanism 4 Stem 5 Limit tappet 6 Closing spring The head of the actuators and the remote adjuster have a scale and symbols that correspond to the following room temperature setpoints: 0 1 2 3 4 5 Valve fully closed (only with RTN51.. and ) Frost protection at 8 C 12 C 16 C 20 C 24 C 28 C If, from the frost protection symbol, the head is turned in the direction of 0, a click can be heard, indicating that frost protection is no longer ensured. Setting setpoint range 2 easily adjustable captive tappets are used to set the required setpoint setting range: Setting maximum limitation Turn tappet until stop is reached (at the setpoint indicator) Push on tappet Turn head until required stop is reached Release tappet Setting minimum limitation 3/8

RTN51 Mounting and installation notes Important: 3 4 3 4 3 4 When mounting the actuator to the valve, ensure that valve and actuator form a right angle. 2111Z38 2111Z36 5 Acvatix TM For that, select scale number 5 and ensure that the actuator rests correctly. Then, tighten the actuator correctly. 3 4 2111Z34 2111Z35 The sensing element of the thermostatic actuator must always be able to acquire the temperature of circulating room air. The type of thermostatic actuator (RTN51.. / / RTN81) is selected based on this criterion. RTN51.. with built-in sensing element The actuator must not be covered by radiator enclosures, furniture or curtains and it must not be affected by direct solar radiation or air drafts. 2143Z02 The actuator must not be fitted in the upright position to ensure that measurement of the room air will not be affected by rising air from the hot water pipe. 2111Z03 4/8

Mounting Instructions are printed on the package. Version with remote sensing element and capillary tube This type of actuator is for use on applications where the criteria of the RTN51.. standard versions are not satisfied. This actuator can be fitted in any position. The sensing element must not be covered and it must not be affected by direct solar radiation or air drafts. In case of unknown conditions (especially in new buildings), it is always advisable to use this version. For comfort reasons, the sensing element should be located as shown in the following illustration: 0.5 m - 1 m 0.5 m - 1 m 1.2 m - 1.5 m 1.2 m - 1.5 m 10 cm min. 2111Z37 When mounted on poorly insulated outer walls, a thermally insulating layer should be fitted in between. Mounting Instructions are printed on the package. RTN81 Version with remote sensing element and remote adjuster For applications where the radiator or convector valve is not accessible or not easily accessible. The actuating section can be fitted in any position. For the sensing element, the same criteria apply as for the (location of the remote adjuster is to be considered). Mounting Instructions no. 74 319 0466 0 are enclosed with the packaging. Maintenance The thermostatic actuators are maintenance-free. Repair Disposal The actuators, sensors and remote adjusters cannot be repaired. The complete units must be replaced. The device must not be disposed of together with domestic waste. Legislation may demand special handling of certain components, or it may be sensible from an ecological point of view. Current local legislation must be observed. Warranty Application-related technical data are only warranted when used in connection with the valves listed under "Equipment combinations" (page 2). When using the RTN.. actuators in connection with valves from other manufacturers, proper functioning must be ensured by the user. 5/8

Technical data RTN51.. RTN81 Design Conformity CEN standard EN 215-1 Drive principle liquid expansion Remote sensor Remote adjuster Capillary tube 2 m (stainless steel 18/8) Functional data Setpoint setting range 8...28 C Setting scale 0,, 1...5, 1... 5 Frost protection position Minimum / maximum limitation captive tappets Perm. medium temperature 120 C Perm. sensor temperature 40 C Influence of water temperature 1.5 K 0.75 K Influence of differential pressure 1 K Hysteresis 1 K Proportional band 2 K Dimensions / weight Dimensions refer to "Dimensions" (page 7) Fixing on valve union nut M30 x 1.5 Weight 0.157 kg 0.202 kg 0.227 kg Housing colors - Actuator RTN51 RTN51G RAL 9016, glossy - Sensor - Remote adjuster Standards Environmental compatibility ISO 14001 (Environment) ISO 9001 (Quality) SN 36350 (Environmentally compatible products) RL 2002/95/EG (RoHS) Materials - Union nut - Stem - Manual knob - brass, nickel-plated - PBT, 30 % glass - ABS General ambient conditions Operation EN 60721-3-3 Transport EN 60721-3-2 Storage EN 60721-3-1 Environmental conditions Class 3K3 Class 2K3 Class 1K3 Temperature +1 +40 C 25 +70 C 5 +50 C Humidity 5 85 % r.h. < 95 % r.h. 5...95 % r.h. 6/8

Dimensions Dimensions in mm RTN51.. Position L1 L2 84.9 11.5 3 87.6 14.2 5 89.5 16.1 RTN81 Revision numbers Product number Valid from rev. no. Product number Valid from rev. no. RTN51..A..A RTN51G..A RTN81..A 7/8

8/8 2005-2010 Siemens Switzerland Ltd Subject to alteration