A product of tomorrow s technology.

Similar documents
Corrugated Tubular Heat Exchangers

5.2. Vaporizers - Types and Usage

MUELLER FALLING FILM CHILLERS

VAD. Variable Area Desuperheaters

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

Selecting TEMA Type Heat Exchangers

TEMA DESIGNATIONS OF HEAT EXCHANGERS REMOVABLE BUNDLE EXCHANGERS NON REMOVABLE BUNDLE EXCHANGERS SOURCE:

V47 Series Temperature Actuated Modulating Water Valves

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

VAD Variable Area Desuperheaters

BRAZED PLATE INSTALLATION MANUAL

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

Sondex Welded heat exchangers:

James M. Pleasants Company

Coil-Wound Heat Exchangers

Quality is Our Strength You can count on Oasis Coils

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.

Desuperheater Online Program Sizing Guidance

How does solar air conditioning work?

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

Refrigeration and air-conditioning. Alfa Laval s offering at a glance

Steam System Best Practices Condensate System Piping

Plate heat exchanger. Applications General heating and cooling duties. Heating by means of steam.

FLASH TANK ECONOMIZER PRODUCT GUIDE

Optimizing Tank Cleaning Operations

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

How To Use A Corona Mdi 110

API Flanged Safety Relief Valves Series 526 CATALOG

Contents and Nomenclature

Milling Chuck Features

Drainage and Grease Management for the Commercial Kitchen

Automobile Air Conditioning Primer

Sample Coolers. Water Steam Process. The largest selection of models offered by any manufacturer.

ORIFICE PLATES. CONCENTRIC BORE: For standard fluid conditions an Orifice Plate would have a centrally located orifice bore.

In-Line Air Separators

Cooling Systems 2/18/2014. Cooling Water Systems. Jim Lukanich, CWT ChemCal, Inc. Grapevine, TX

GE Oil & Gas. Air cooled heat exchangers Robust and reliable for all loads and applications

Valve Steel. Valve Steel

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

The Unique Accelabar Flow Meter

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

Seamless stainless tubes for hydraulic and instrumentation systems

Pipe Cutting and Beveling Clamshells

Stainless Steel Perimeter Recirculation Systems Engineered supply and return systems for swimming pools, water features and aquatic facilities.

Rusty Walker, Corporate Trainer Hill PHOENIX

UNIT 2 REFRIGERATION CYCLE

Air Eliminators and Combination Air Eliminators Strainers


Are these noise cancelling devices needed to make your chiller quiet??

Technical Services & Capabilities

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

Defining Quality. Building Comfort. Heating and Cooling Coils

BLADDER SURGE CONTROL SYSTEM

Commercial Gas Water Heaters

Thermostatic expansion valves type TR6 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

INSTRUMENTATION & CONTROLS VALVE & AUTOMATION EXPERTS VALVE REPAIR TUBE SERVICES

C. starting positive displacement pumps with the discharge valve closed.

Transformer oil cooler ALFA A02

Tubular solutions for the Solar Power Industry Rise in success with precision

AdSORPTION CHILLER NAK

OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: w.tecni-ar.com.br

STORAGE SYSTEMS PUSH BACK RACK SYSTEMS. Innovative Solutions for Storage and Material Handling Systems

Vacuum drying oven for non-flammable solvents

Solenoid valves Type EVU

solarplus solar systems general features

Fixed Access Ladders. Table of Contents. 1. Legislative Requirements

Measurement While Drilling (MWD) Tools

VOLU-probe/SS. Stainless Steel Pitot Airflow Traverse Probes. Accurate airflow measurement for demanding applications

WD600 STEAM TRAPS. Thermodynamic Steam Trap

GE Oil & Gas. Air Cooled Heat Exchangers. Robust and reliable for all loads and applications

High School Graduation years 2013, 2014, Unit/Standard Number

Confectionery Products

PRELIMINARY BROCHURE. Uddeholm Corrax

Cost-effective solutions for all applications.

EcoCWave. The all-round talent for aqueous part cleaning.

T 300 Tray sealer. Automatic tray packaging in the smallest of spaces

Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min.

Commercial Gas Water Heaters

Heat Exchanger Thin Film Foul Release Applications Corrosion Resistant Protective Coatings Grit Blast Surface Prep of Tubular Equipment

FVA/A1 saturated-steam sterilizer

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

HEAT TRANSFER ANALYSIS IN A 3D SQUARE CHANNEL LAMINAR FLOW WITH USING BAFFLES 1 Vikram Bishnoi

Premium Tubular Solutions Super Duplex Welded Tubes for Umbilical Applications

High pressure reactors Where are your limits?

HIGH STANDARD VALVES FOR NON-STANDARD CONDITIONS.

Oil Sight Glass BENEFITS

Varel International Workover Bits for remedial, re-entry AND frac plug Drilling Applications

Heat-Pipe Heat Exchanger

DRYPOINT RA REFRIGERATION DRYER RANGE

UV Disinfection Systems A Series. Main Applications: Drinking Water, Process Water, Warm Water / Legionellae. IT T Industries Engineered for life

SUPRApak Multi-Stack Series Filter Housings SUPRApak Filtration For High Volume Depth Filtration

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Heat Pipe Selection Revision 12/04/2001

DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING

Daniel Venturi Tubes and Flow Nozzles Brochure

Aluminium Plate-Fin Heat Exchangers

Transcription:

heat exchangers

JAD heat exchangers are distinctive in every sense of the word. From the helically coiled tube bundles to the innovative angular connections, the JAD is a perfect balance of engineering craftsmanship and exceptional performance. Designed to deliver, whenever, wherever, they are required. A product of tomorrow s technology.

angular connections compact vertical installation complete SS316L welded construction closely packed, circular layers of helically, corrugated tubes Typical Applications district energy heating hydronic heating steam-water systems (flooding heat exchangers) chilled water systems ground water systems refrigeration systems (ammonia absorption, freon) clean steam generation vapour condensers JAD Typical Construction Advantages large heat transfer surface area within a compact space results in a highly efficient and effective system complete SS316L welded construction ensures strength and durability of product in reboiler applications design allows superheating of the steam as a vapour condenser it sub-cools the condensate coiled tube bundle and cascading connection angles prevent debris build-up, creating a selfcleansing effect compact vertical design requires small installation footprint ideal for applications with space constraints SS316L welded material of construction helically coiled tube bundles (corrugated or smooth) cascading connections vertical installation

JAD Line The JAD is unique in design, and diverse in capacity. Developed for flexibility, it can be an integral component of any sophisticated heat recovery system, while just as suitable for every day use. Every component of this heat exchanger is engineered to optimize performance, resulting in a compact, highly efficient and effective system. One of the most characteristic features of the JAD family is the closely packed, circular layers of helically, corrugated tubes that constitute the tube bundle. Each layer is positioned in the opposite direction to the surrounding layer, resulting in an overall criss-cross pattern. The effect is a high heat transfer surface area within a compact space. The tube orientation fosters turbulent flow and creates more uniform heating of the fluids, thus increasing the overall heat transfer coefficient. The JAD angular connections accommodate smooth, gradual flow entrances and exits from the unit, reducing any sharp corners that can result in flow separation and where dirt buildup can occur. The vertical configuration has the intrinsic advantage of being used as a condenser or evaporator for supporting changes of fluid phases within the unit (e.g. steam to liquid). The small footprint results in less installation space requirements and low installation costs. It is ideal for applications with space constraints. The strength and durability of JAD heat exchangers are due to their complete welded, stainless steel 316L material of construction. This allows for high pressure and temperature ratings on standard products, and ensures that the products are suited for the most demanding of applications. After fabrication, the heat exchangers are additionally passivated and electropolished to enhance the corrosion resistance of the material. Steam Flooded Heat Exchanger For steam applications, contrary to conventional designs, the unique JAD helically corrugated tube bundles and its vertical structure enable the heat exchanger to not only condense the steam, but also to sub-cool the condensate to within degrees of the incoming cold water, recovering the maximum amount of excess heat available. The bottom of the heat exchanger can be flooded to various degrees with condensate, enabling the operator to have smoother and better control of the performance of the overall system. Clean Steam Production The vertical JAD design is often used in the generation of clean steam. Considered a refined thermosiphon reboiler, the partially flooded exchanger has the ability to superheat the steam, facilitating better control of the steam output, and allowing the transport of dry steam to other parts of the system. Additionally, its compactness is more desirable than standard submerged kettletype reboilers, which has larger footprint requirements. Additionally, the inherent spring-like characteristics of the coiled tube bundle enable these heat exchangers to withstand high temperature differentials between the two mediums, variations in steam pressures, and possible steam hammers and shocks in the system. jadfamily 615 mm (24.20 in) 836 mm (32.91 in) 1 096 mm (43.15 in) 874 mm (34.38 in) 981 mm (38.62 in) 1 458 mm (57.40 in) 781 mm (30.73 in) 1 461 mm (57.52 in) 868 mm (34.16 in) 1 475 mm (58.08 in) 873 mm (34.38 in) 1 508 mm (59.37 in) 923 mm (36.34 in) 1 484 mm (58.43 in) 1 084 mm (42.68 in) 884 mm (34.80 in) 1 678 mm (66.06 in) 1 028 mm (40.47 in) 878 mm (34.57 in) 778 mm (30.63 in) 2 088 mm (82.64 in) 2 348 mm (92.44 in) H line SX(K) line JAD X(K) 2.11 line JAD X(K) 3.18 line JADX (K) 5.38 line JAD X(K) 6.50 line JAD X(K) 9.88 line JAD X(K) 12.114 line JAD X(K) 14.163 JAD X(K) 17.340

Technical Product Specifications TYPE Heat Transfer Area Height Diameter Connections m 2 sq ft mm in mm in in HELICALLY CORRUGATED TUBES H-0K 0.29 3.1 615 24.20 80 3.15 3/4 H-1K 0.76 8.2 836 32.91 102 4.00 1 H-2K 1.32 14.2 1 096 43.15 102 4.00 1 JAD XK 2.11 1.20 12.9 1 458 57.40 80 3.15 1 1/2 JAD XK 2.11.08.68 0.63 6.8 781 30.73 80 3.15 1 1/2 JAD XK 3.18 2.00 21.5 1 461 57.52 102 4.00 2 JAD XK 3.18.08.75 1.20 12.9 868 34.16 102 4.00 2 S-0XK 2.30 24.8 874 34.38 140 5.50 2 S-1XK 3.14 33.8 981 38.62 159 6.26 2 1/2 JAD XK 5.38 4.00 43.1 1 475 58.08 140 5.50 2 JAD XK 5.38.08.71 2.30 24.8 873 34.38 140 5.50 2 JAD XK 6.50 5.70 61.4 1 508 59.37 159 6.26 3 JAD XK 6.50.08.72 3.14 33.8 923 36.34 159 6.26 3 JAD XK 9.88 10.70 115.2 1 484 58.43 219 8.63 4 JAD XK 9.88.08.85 6.20 66.7 1 084 42.68 219 8.63 4 JAD XK 9.88.08.65 4.97 53.5 884 34.80 219 8.63 4 JAD XK 12.114 18.40 198.1 1 678 66.06 273 10.75 4 JAD XK 12.114.08.75 8.78 94.5 1 028 40.47 273 10.75 4 JAD XK 12.114.08.60 6.46 69.5 878 34.57 273 10.75 4 JAD XK 12.114.08.50 6.25 67.3 778 30.63 273 10.75 4 JAD XK 14.163.08.120 25.00 269.1 2 088 82.64 324 12.75 4 JAD XK 17.340.08.120 60.80 654.4 2 348 92.44 508 20.00 6 AIC Organization AIC is a manufacturer of heat exchangers and customdesigned heat transfer, and heat recovery, products. We value engineering excellence. Our strengths lie in the high quality and fine craftsmanship of our products, the engineering expertise of our team, and our quest to continuously develop technologically new and exciting products. AIC s diverse product offerings are installed worldwide. Our state-of-the-art facilities utilize the most leading edge processes, advanced automated and robotic systems, and well sourced materials for the most stringent of applications. With our own tube mills, ovens, and CNC machines, we can design, manufacture, and control every part of our process. Our stringent quality management system ensures that we continue our dominance in providing top quality products that clients have come to associate with the AIC brand. SMOOTH TUBES JAD X 2.11 1.20 12.9 1 458 57.40 80 3.15 1 1/2 JAD X 3.18 2.00 21.5 1 461 57.52 102 4.00 2 JAD X 5.38 4.00 43.1 1 478 58.19 140 5.50 2 1/2 JAD X 6.50 5.70 61.4 1 508 59.37 159 6.26 3 JAD X 9.88 10.70 115.2 1 484 58.43 219 8.63 4 JAD X 12.114 18.40 198.1 1 678 66.06 273 10.75 4 THREADED CONNECTIONS AVAILABLE UP TO 2-1/2 INCH FLANGE CONNECTIONS AVAILABLE FROM 2 INCH AND LARGER - COMPATIBLE TO PN 10/ PN 16 OR ANSI 150LB / 300LB MATERIAL OF CONSTRUCTION standard optional SHELL STAINLESS STEEL 316L TUBES STAINLESS STEEL 316L NOZZLE STAINLESS STEEL 316L FLANGES STAINLESS STEEL 316L LINED SOLID STAINLESS STEEL STANDARD DESIGN PARAMETERS TUBES SHELL TEMPERATURE 217 C (422 F) 217 C (422 F) PRESSURE 21 bar (300 PSI) 21 bar (300 PSI) OPTIONAL RATINGS AVAILABLE UPON REQUEST

Performance The JAD design has fundamental advantages over conventional straight or u-tube heat exchangers. Originally designed and manufactured specifically for the district energy market, it has since transcended into the mainstream heat recovery market, surpassing competitors in efficiency and performance capabilities. We are certified by renowned international inspection authorities. Our quality process and management systems fulfill the requirements of ISO 9001 Quality Management System. AIC heat exchangers are designed, tested and manufactured in accordance with ASME (Section IV and VIII) and PED (97/23/UE) regulations. Product designed and made in EU Advanced Industrial Components Inc. (AIC) 2899 Portland Drive Oakville, ON L6H 5S4, Canada T 905.829.4666 F 905.829.4646 TOLL-FREE: 1-888-738-1350 www.aicheatexchangers.com Authorized Representative AIC S.A. 03/2010 LIT41.01 JANYK