Dekati. FPS-4000 Fine Particle Sampler

Similar documents
How To Use A Ds340 (Dsp)

Online Infrared Flue Gas Analyzer Gasboard 3000

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Direct steam injection humidifiers

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Stack Sampling Stack sampling or source sampling

Kompressoren. Adsorption Dryer AD

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

BB-18 Black Body High Vacuum System Technical Description

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

Analytical Instruments Smart Analyzer 90 Type SMA

S300 Series Dust Monitors

COMBIMASS. Technical Data COMBIMASS eco-bio +

Instruction Manual. T3111 T3111L T3111P T3111Ex

Rense Product Range. Customized Humidity Solutions. Rense Product Range

Marine after-treatment from STT Emtec AB

Vacuum drying oven for non-flammable solvents

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Material test chamber with mechanical convection

ACE. Automated Soil CO 2 Exchange System. Soil flux: an important component of total carbon budget

The Unique Accelabar Flow Meter

Refrigeration Compressed Air Dryer Buran Ultrapulse

ThermoSorb Desiccant Dryers

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Easily installed and simple to set up, Flow Pulse uses an acoustic technique never before seen in flow measurement to deliver reliable results across

USB-500/600 Series Low-Cost Data Loggers and Accessories

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Solenoid valves Type EVU

6 Crankcase Ventilation

OZW30. Central Unit SYNERGYR

Cooking at the Speed of light!

Adsorption air dryers ADS 1 215

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

How is Dew Point Measured Reliably?

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Duct Humidity Transmitter

API Marine. BMS Presentation. Ballast Measurement Systems

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

HEAVY DUTY STORAGE GAS

Rotary screw compressors kw 5,5 7, , bar MODULO

SALES SPECIFICATION. SC7640 Auto/Manual High Resolution Sputter Coater

RADIATION MONITORING SYSTEMS

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Technical Specification. Generating Set with Waukesha engine burning natural gas

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

REGULATORS 175/153 Series

Product Data. Thermal Comfort Data Logger Type Including Application Software Type 7301

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Steam System Best Practices Condensate System Piping

Incubator with mechanical convection

DUST EMISSION MONITORING SYSTEM

VDL 53 - Vacuum drying oven for flammable solvents

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Fume Extraction: Guide to Safely Managing Solder Fumes in the Workplace

Marine after-treatment from STT Emtec AB

Transformer oil cooler ALFA A02

FREJA 300 Relay Testing System

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

USB-500 Series Stand-Alone, Low-Cost Data Loggers

EJECTOR AIR REMOVAL SYSTEMS ENGINEERING DATA BULLETIN # PVS ARS PAGE 1 OF 5

BROEN UNiFlEx FiTTiNgs FOR BURNiNg gases OEN OEN ifl ifl FOR FOR BURN BURN gas gas

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Micro Motion 3098 Gas Specific Gravity Meter

MEMBRANE VACUUM MINI PUMPS

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry

86 C Freezer Accessories. More Choices. Choose from a Wide Selection of Racks, Monitoring Systems and Other New Brunswick Freezer Accessories

- Designed to meet with the environmental stresses of ships and heavy industry. SESOBS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Heavy Fuel Oil supply units. The world s best selling HFO supply unit. The right choice for any conditions

1 DESCRIPTION OF THE APPLIANCE

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

Automatic Bypass Control AVDO

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

OT 40L / 90L. Laboratory Steam Sterilizers

DRYPOINT RA REFRIGERATION DRYER RANGE

Instruction Manual Dräger MSI ALV

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

data sheet DONATELLO Rev. I emiss - 25/10/ PRO03 code Automatic tissue processor DONATELLO

Hydraulic Control Solutions

Access Server Rack Cabinet Compatibility Guide

VAD Variable Area Desuperheaters

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

-86 C Freezer Accessories. New Brunswick Freezer Accessories. A wide selection of racks, monitoring systems and more!

Powers Controls TH 192 S Single Temperature Room Thermostat

High-efficient gas boiler CompactGas

FVA THIRD-GENERATION VERTICAL SATURATED-STEAM STERILIZERS

UDSA - UDSBD unit heater

Strong partners offer perfect solutions. Automatic filtration and maintenance of engine lubricating oil in diesel locomotives

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS

Digital inductive conductivity transmitter

Typical Aluminum GFM Mass Flow Meter

Transcription:

Dekati FPS-4000 Fine Particle Sampler Automotive exhaust and combustion aerosol dilution Versatile sampling system Real-time dilution condition control Excellence in Particle Measurements

Dekati FPS-4000 Fine Particle Sampler Dekati Fine Particle Sampler is a guaranteed solution for diluting and conditioning aerosol and gaseous samples for measurement instruments. The two stage dilution system features unmatched versatility with applications reaching from automotive pre- and post after-treatment measurements to nucleation studies. Operation Principle A raw sample is extracted from the source ( i.e. exhaust or flue gas) by using a stainless steel probe. The sample is subsequently diluted in two stages employing a perforated tube and ejector dilution, respectively. regulated with a valve unit which contains critical orifices for accurate and repeatable control. Each FPS-4000 is individually calibrated by gas flow measurements which span all operating conditions. The dilution ratio calculation result is saved in real-time along with temperature and pressure data in an easily accessible form for post-processing of the data. Analogue output of the dilution ratio is also available for easy integration into existing data logging systems. Sample in The primary dilution takes place within the perforated tube where the raw sample mixes with dilution air forced through small pores in the perforated tube wall. The perforated tube is housed within the primary diluter body which can be heated or cooled. The dilution ratio of the primary dilution stage can be adjusted by changing the dilution airflow into the primary diluter. The secondary dilution stage is an ejector pump which draws the sample from the primary dilution stage and dilutes it further. The diluted gas exiting the ejector diluter is always at an ambient pressure and temperature regardless of the initial raw sample gas characteristics. The ejector diluter dilution ratio has three options: low, medium or high. Dilution temperatures and pressures are measured in realtime by a control unit enabling second-by-second dilution ratio calculation which takes changes in raw sample properties directly into account. The dilution air flows are Sample out Primary dilution air flow Secondary dilution air flow

Excellence in Particle Measurements Applications FPS-4000 is a flexible tool for any aerosol dilution and conditioning tasks. The applications include: Automotive exhaust dilution Pre- and post after-treatment devices Power plant flue gas dilution Small-scale stationary source dilution Aerosol transformation research for all sources Nucleation/Condensation studies Agglomeration studies Dekati Business advantages FPS-4000 Advantages The most versatile sampling system commercially available Single device for all dilution tasks Can be connected pre- and post after-treatment systems with an adjustable dilution ratio Increase efficiency and repeatability by using the same setup in all measurement locations Can be integrated to existing data logging systems Save time and money with easy data collection Technical advantages Real-time dilution ratio calculation and data storage Adjustable dilution ratio and dilution temperature Control of all features from user-friendly PC-software Sophisticated handling of volatile vapours Removal with heated dilution Nucleation tendency studies with cooled dilution and a residence time chamber Removal with Dekati Thermodenuder Calibrated with traceably calibrated gas and pressure flow meters Extremely low losses no loss correction needed Particle residence time within the system < 0.5 seconds Particles travel on a straight line, no bends or moving parts

Accessories Full automotive sampling setup FPS-4403 Includes the following items for a comprehensive dilution and conditioning system for automotive and any small-scale application: DH-1723 Pressurised air heater for dilution air For heated dilution air up to 350 C DH-1423 Probe heater For heating the dilution probe FPS-4001 Pressurised air filtration and drying unit For conditioning the dilution air to eliminate dilution artefacts FPS-4005 Automatic pressure controller For automatic control of the FPS operating pressure ELA-424 Mobile rack for Dekati instruments For easy transfer of instruments between measurement locations Available for 230V and 110V Full stack sampling setup FPS-4503 Includes the following items for a comprehensive dilution and conditioning system for stack or large duct sampling: DH-1723 Pressurised air heater for dilution air For heated dilution air up to 350 C FPS-4230 Stack heater, optional pre-cut cyclone and one nozzle for isokinetic sampling For large stacks, includes an optional 2.5 μm-cut mini-cyclone ELA-419, set of 5 sampling nozzles for the minicyclone For isokinetic sampling FPS-4001 Pressurised air filtration and drying unit For conditioning the dilution air to eliminate dilution artefacts FPS-4005 Automatic pressure controller For automatic control of the FPS operating pressure ELA-424 Mobile rack for Dekati instruments. Can house either FPS+DMM or FPS+ELPI, must be specified when ordering. For easy transfer of instruments between measurement locations ELA-441 Extension cable set (8 m) For increased flexibility in placement of the sampling probe Available for 230V and 110V Dekati Thermodenuder ELA-230 Dekati Thermodenuder always guarantees a dry soot mode of particles for measurement from automotive exhaust sources. The Thermodenuder removes volatile vapours and particles by using a combination of heating and active carbon. Residence Time Chamber ELA-400 Residence Time Chamber is used in nucleation studies to give the nucleated particles time to grow into the measurement range of the measurement instruments. The Residence Time Chamber is directly applied between the primary and secondary dilution stages.

Software Dekati FPS-4000 is fully controlled via an RS-232 port by using the LabViewbased FPSVi programme. FPSVi features easy and simple control of dilution ratio and temperature through a user-friendly interface. All measured and calculated information is stored in a user-defined file for easy access. Additional analogue inputs and temperature signals can also be logged into the FPSVi save file. Specifications Coolers and heaters Primary probe cooler Probe heater Dilution air heater Thermodenuder heater Vortex TM type cooler (Accessory) 350 W 1000 W 350 W Hardware Specifications Dimensions Weight Material Power consumption Connections Probe inlet Probe outlet Pressurised air inlets 560 mm x 410 mm x 310 mm (can be mounted in a 19 rack) 30 kg AISI 316 (stainless steel) 1 earthed electrical power outlet, Max. 2000 W NW40 flange or 6 mm drilled through pipe connector (eg. Swagelok, Gyrolok ) NW40 flange or 1-5 pcs. of 12x1 mm tube Quick connector for 10 mm plastic tube Data acquisition Computer requirement PC/Laptop connection Analogue input Analogue output (dilution ratio) K-type thermocouples Pressures Pentium processor, 16 MB RAM, MS-WINDOWS NT 4.0, XP or 2000 RS232 2 x 1-5 V 1-5 V 8 channels 2 x 4-20 ma

Dekati FPS-4000 Fine Particle Sampler Specifications Dilution specifications Dilution ratios* 1:20-1:200 Dilution temperature 0-350 C Primary diluter 1:3-1:20 Secondary (ejector) diluter 1:7-1:15 Raw sample temperature 0-600 C Raw sample pressure 750-2000 mbar abs Purified pressurised air for dilution Particle concentration recommended < 100 / cc RH non-condensing at 40 C Pressure (absolute) max. 9 bar abs min. 6 bar abs Operating pressure 4.5 bar abs Flow rate (at 1.013 bar, 20ºC) max. 220 lpm Flows (at 1.013 bar, 20ºC) Sample flow 0-10 lpm Primary dilution air flow 2-40 lpm Secondary dilution air flow 40-140 lpm Diluted sample flow 60-160 lpm Cooling agent pressurised air or water Pressurised air for cooling 3-8 bar, 600 lpm, moisture free FPS sampling probe Dekati is a registered trademark of Dekati Ltd. Patent pending. Aerosol Dekati Ltd. reserves the right to make Instruments changes to product(s) described herein without prior notice. Copyright Dekati Ltd. 2010. *Dilution ratio displayed within +/- 10% of reading *Dilution ratio over 100 achievable only with a stable inlet pressure *Dilution ratio adjustable in discrete steps with at least one step between 100 and 200 The Dekati Fine Particle Sampler has been specially designed to comply with the standard criteria of the European Union s DG-TREN Particulates Project for harmonized particle measurements. It incorporates the requirements of modern particle sampling instruments for both scientific research and industrial quality control measurements. For more information, please contact: sales@dekati.fi Dekati Ltd. Osuusmyllynkatu 13 FIN-33700 Tampere Finland Tel. int. +358 3 3578 100 Fax int. +358 3 3578 140 E-mail sales@dekati.fi www.dekati.fi Dekati Ltd. is specialized in the design and manufacture of innovative fine particle measuring and sampling devices. Since its founding in 1994, Dekati has become the technological market leader in producing fine particle measurement instrumentation for various applications and hundreds of customers. Pictorino Oy 8/2010