Flat Transformers for Low Voltage, High Current, High Frequency Power Converters

Similar documents
Improved PFC Boost Choke using a Quasi-Planar Winding Configuration Dave Shonts Schott Corporation 1000 Parkers Lake Road Wayzata, MN 55391

Chapter 14: Inductor design

Iron Powder Cores for Switchmode Power Supply Inductors. by: Jim Cox

Selecting IHLP Composite Inductors for Non-Isolated Converters Utilizing Vishay s Application Sheet

Chapter 15: Transformer design

Chapter 10. AC Inductor Design. Copyright 2004 by Marcel Dekker, Inc. All Rights Reserved.

Planar versus conventional transformer

Power Supplies. 1.0 Power Supply Basics. Module

AN109. Push-Pull Converter Design Using a CoreMaster E2000Q Core. By Colonel Wm. T. McLyman. Figure 1 Single output push-pull converter.

Edmund Li. Where is defined as the mutual inductance between and and has the SI units of Henries (H).

Voltage Loss Formula s

1. The diagram below represents magnetic lines of force within a region of space.

Chapter 16. Current Transformer Design. Copyright 2004 by Marcel Dekker, Inc. All Rights Reserved.

CHAPTER 4 DESIGN OF INTEGRAL SLOT AND FRACTIONAL SLOT BRUSHLESS DC MOTOR

Application Note. So You Need to Measure Some Inductors?

Power Electronic Circuits

AN100. The Elusive Tapped Output Inductor. By Colonel Wm. T. McLyman

ABSTRACT 1. INTRODUCTION

INDUCTOR DESIGN IN SWITCHING REGULATORS

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Power supplies. EE328 Power Electronics Assoc. Prof. Dr. Mutlu BOZTEPE Ege University, Dept. of E&E

Introduction to Power Supplies

Objectives 200 CHAPTER 4 RESISTANCE

Line Reactors and AC Drives

Principles of Adjustable Frequency Drives

VICOR WHITE PAPER. The Sine Amplitude Converter Topology Provides Superior Efficiency and Power Density in Intermediate Bus Architecture Applications

Toroids. Toroids. Design Considerations

An equivalent circuit of a loop antenna.

" PCB Layout for Switching Regulators "

LECTURE 31 Inductor Types and Associated Magnetic Cores

Electrician s Math and Basic Electrical Formulas

Renco Electronics, Inc.

Theory of Heating by Induction

ELECTRIC FIELD LINES AND EQUIPOTENTIAL SURFACES

SELECTION GUIDE. Nominal Input

Current and Temperature Ratings

Inductor and Magnetic Product Terminology

DESIGN GUIDELINES FOR LTCC

CONSTRUCTING A VARIABLE POWER SUPPLY UNIT

CHAPTER 2 EXAMPLES AND TABLES

Solar Inverters. Ferrites in Renewable Energies: Solar Inverters. customer requirements. Support and flexibility to design custom product to fulfill

EMI and t Layout Fundamentals for Switched-Mode Circuits

ECEN 1400, Introduction to Analog and Digital Electronics

Thermal Management Solutions for Printed Circuit Boards used in Digital and RF Power Electronics and LED assemblies

WINDING RESISTANCE TESTING

ES250: Electrical Science. HW7: Energy Storage Elements

CS4525 Power Calculator

CMR Series Isolated 0.75W Single and Dual Output Isolated DC/DC Converters

Magnetics in Switched-Mode Power Supplies

Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E.

A new technology for high current, low insertion force, low resistance and long cycle life power connectors

AMP Standard Terminals and Splices. RoHS. Ready

Selecting the Optimal Inductor for Power Converter Applications

Application Note AN:005. FPA Printed Circuit Board Layout Guidelines. Introduction Contents. The Importance of Board Layout

DC GENERATOR THEORY. LIST the three conditions necessary to induce a voltage into a conductor.

Inductors. AC Theory. Module 3

Current Probes. User Manual

Measurement of Capacitance

New High Current MOSFET Module Offers 177 µω R DS(on)

understanding medium frequency induction melting furnace and its components

STUDY MATERIAL FOR CLASS Physics- CURRENT ELECTRICITY. The flow of electric charges in a particular direction constitutes electric current.

Errors Related to Cable Resistance Imbalance in Three Wire RTDs

Chapter 11. Inductors ISU EE. C.Y. Lee

Custom Products. Magnetic Components. Vishay Dale.

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

The full wave rectifier consists of two diodes and a resister as shown in Figure

Quality Policy Statement... I.F.C. Introduction... 2 Magnetic Properties of Fair-Rite Materials... 4 Fair-Rite Materials... 6

Direction of current flow through conductor. Fig. 1 Magnetic field generated by current flow

Mounting Instructions for SP4 Power Modules

Modeling and Analysis of DC Link Bus Capacitor and Inductor Heating Effect on AC Drives (Part I)

7-41 POWER FACTOR CORRECTION

d di Flux (B) Current (H)

ANADOLU UNIVERSITY DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

Diode Applications. by Kenneth A. Kuhn Sept. 1, This note illustrates some common applications of diodes.

7. What is the current in a circuit if 15 coulombs of electric charge move past a given point in 3 seconds? (1) 5 A (3) 18 A (2) 12 A (4) 45 A

Tamura Closed Loop Hall Effect Current Sensors

Aircraft Electrical System

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

The Importance of the X/R Ratio in Low-Voltage Short Circuit Studies

Efficient and reliable operation of LED lighting is dependent on the right choice of current-limiting resistor

BSNL TTA Question Paper-Instruments and Measurement Specialization 2007

Line Loss WSDOT Winter 2008 BZA

Which is the best PFC stage for a 1kW application?

Transformer Calculations

Using Thermocouple Sensors Connecting Grounded and Floating Thermocouples

ElectroMagnetic Induction. AP Physics B

Designing with Magnetic Cores at High Temperatures

A Simple Current-Sense Technique Eliminating a Sense Resistor

Ohm's Law and Circuits

CHAPTER 5 PHOTOVOLTAIC SYSTEM DESIGN

Voltage Drop. Voltage Drop 1

Safety technique. Emergency stop module BO 5988 safemaster

75 Ω Transmission System

Transformer circuit calculations

98% Efficient Single-Stage AC/DC Converter Topologies

Evaluating AC Current Sensor Options for Power Delivery Systems

ALLOY POWDER CORE SERIES INTRODUCTION

Coupling Magnetic Signals to a SQUID Amplifier

Thermoelectric Generator (TEG) for Heavy Diesel Trucks John C. Bass, Aleksandr S. Kushch, Norbert B. Elsner Hi-Z Technology, Inc.

MADP T. Non Magnetic MELF PIN Diode

Transcription:

Flat Transformers for Low Voltage, High Current, High Frequency Power Converters D. Trevor Holmes & K. Kit Sum Flat Transformer Technology Corporation 3122 Alpine Avenue Santa Ana, California 92704, U.S.A. Tel.: (714) 708 7090 +++ Fax: (714) 708 7091 Abstract: The flat transformer is a magnetic structure comprising a number of elements, Ne, each of which can be identified as an individual transformer by itself. These elements are arranged to obtain a transformation ratio (an equivalent turns ratio) of 1 : 1 N e, or Ne : 1, with a single turn secondary winding. With a primary having a number of turns N p, the transformation ratio is N p N e : 1. The flat transformer is particularly well asuited to low profile, low output voltage, high current applications for high frequency switched-mode power conversion applications. It has extremely low leakage inductance, high magnetization inductance, excellent coupling, very low temperature rise, and is easily insulated for high dielectric requirements with no appreciable degradation in performance. Now commercially available, the FLAT TRANSFORMER AND INDUCTOR MODULES have very low profile. These modules can exceed most high density high power converter performance expectations. Fundamental Concepts In a low output voltage high frequency conventional transformer, the output winding is usually configured to have a single turn. If the transformer has a turns ratio of n to 1, then the primary winding will have n turns. The number of primary turns cannot be less than n, by design. In the flat transformer [1], the magnetic structure is comprised of many ferrite cores. The ferrite cores can be arranged in groups or elements of 1 to n in number. That is to say, 1 or more ferrite cores can be a group or element by itself; and the complete transformer is built with more than one of these elements. Turns ratios are usually referred to a single core. When a group of cores are used, the resulting equivalent turns ratio is not reflected in individual cores, but rather is a reflection of the transformation ratio of the whole. Based on this principle, a single primary turn is feasible with the flat transformer. +V i 3i + 3 V Figure 1. Flat Transformer with Transformation Ratio of 3 : 1 D. T. Holmes & K. K. Sum 1

In the most basic arrangement of the flat transformer, a single turn is used for the primary as well as the secondary; and the transformation ratio of this flat transformer is now determined by the number of elements, N e. Higher transformation ratios may be obtained by using more than one primary turn. The transformation ratio of the flat transformer is determined by the product of the number of elements, N e, and the number of primary turns, N p : Transformation Ratio = (N e N p ) to 1 (N p =2, shown below) +V i 6 i + 6 V Figure 2. Flat Transformer with 3 Elements and Transformation Ratio of 6 : 1 Flat Transformer-Inductor Module Design This module is optimized for bridge or half-bridge converters providing a 5-volt output with a single secondary turn, and operates at a switching frequency of 250 khz (500 khz output ripple). Each module can have a power delivery capacity of 150 watts. The transformer part of this module is made up of two rectangular ferrite blocks with a square hole at the center. See Figure 3(a). An additional block, with a total of three blocks, is added to the combination to perform the function of the inductor. Two single-turn secondary windings are inserted in each block to incorporate the output winding with a center-tap. Each turn is bonded to the inside surface of the block, and follows a 180 helical path such that the turn connects from one outside corner diagonally to the other outside corner. See Figure 3(b). The two blocks are arranged to have the secondary winding of one block connected in series with the adjacent block. The connections to the secondary windings are located at the corners of the blocks as shown in Figure 3(c). (a) (b) (c) Figure 3. (a) Single Core Block, (b) Core Block with Helical Windings, and (c) Two Blocks Connected Together. This secondary winding design succeeds in eliminating the labor normally required of fabricating a tapped secondary winding. D. T. Holmes & K. K. Sum 2

The module is connected directly to a TO-247 dual rectifier package as shown in Figure 4. Since the inductor is on the tap side, which is the negative side, the cathodes of the rectifiers are connected directly to the output terminals. Figure 4. Electrical Layout of Flat Transformer Module Figure 5 shows a single flat transformer module complete with top and bottom plates (which form the output terminals) and output rectifiers. The total height of the module is 11.7 mm. (0.46 ). This arrangement permits modularity in transformer construction never before possible, and is one of the chief contributing factors in achieving high power density. Direct current power is the product of voltage and current. A smaller transformer core helps to reduce the size of the transformer. The true contrubution in achieving high power density must rely on the ability of this transformer to provide high current density also. High current density is the second most important contribution of the flat transformer. More about this later. Figure 5. Complete Assembly of One Flat Transformer Module Specifications and Related Experimental Details: The core blocks are made of MN-8CX (Ceramic Magnetics, Inc.) material. D. T. Holmes & K. K. Sum 3

Each core block has a core area of 0.34 cm 2 and a core volume of 1 cm 3. The height of the core block is 10.2 mm. (0.4 ), which is also the same as the width. The length of the core block is 13.67 mm. (0.538 ). Since each module is comprised of two blocks, the module core area (for the transformer part) is 0.68 cm 2, the magnetic path length is 2.8 cm., and the module core volume is 2 cm 3. The inductance is 10 µh/module/turn 2 ; i.e., the multiplying factor is N 2, where N is the number of turns. Example: If there are 4 turns wound on the module, the inductance will be 4 2 X 10 µh = 160 µh. Due to the close proximity of the windings and core layout, the maximum leakage inductance per module is only 4 nh. This leakage inductance was measured using 5 modules with the rectifier terminals shorted by a copper strap, and a three turn primary winding. The measured (leakage) inductance for 5 modules with 3 primary turns was 0.18 µh Since the primary inductance is given by the inductance of the module times the number of modules times the square of the number of primary turns, or, mathematically, L p = L mod N e N p 2 where L p is the primary inductance, L mod is the inductance of 1 turn through 1 module (2 blocks), N e is the number of modules, and N p 2 is the square of the number of primary turns. This formula gives the primary inductance when measured with the secondary open-circuited; and will give the leakage inductance, when measured with secondary shorted. For a 5-module half-bridge flat transformer with 3 primary turns, the following substitutions can be made: Therefore, 0.18µH = L mod 5 3 2 L mod = 0.18µH 5 3 2 = 180nH 45 = 4nH The inductor section is comprised of a 3-turn winding with an inductance of 2.7 µh (min.) at 20 Amps., and 2.0 µh (min.) at 30 Amps. The core loss characteristics (per module) relating flux density to operating frequency are shown in Figure 6. A typical 5-module demonstration circuit designed for a 750-Watt half-bridge converter with a flux density of 75 mt has a total (for all 5 modules) loss of approximately 1.25 Watts. If the same loss is assumed for the windings, which would be extremely conservative, the total transformer loss will be 2.5 Watts. Based on these numbers, the transformation efficiency is, Efficiency η = P o P i 100% = P o P o + P L 100% where P o is output power, P i is input power, and P L is total transformer loss. D. T. Holmes & K. K. Sum 4

(a) (b) Figure 6. Transformer Section: (a) Relating Frequency to Power Loss, and (b) Relating Flux Density to Power Loss; per module Hence, Efficiency η = 750 100% = 99.67%. 750 + 2.5 Achieving High Power Density with High Current Density This is the greatest electrical difference between a flat matrix transformer and a conventional transformer. Though the physical differences are obvious, the electrical differences are quite subtle, and remains unclear until a closer examination is made. For any homogeneous conductor of uniform cross section, the resistance of the conductor depends on the length, the area of the cross section, the temperature, and the material of which it is composed. The resistance varies directly with the length and inversely with the area of cross section. The resistance of a conductor can be formulated as R = ρ l A where R is the resistance, ρ is the resistivity (which depends on the temperature) of the material, l is the length of the conductor, and A is the area of cross section normal to the direction of the current flowing in the conductor. For pure metals the resistance increases with the temperature. In this case, the change in resistance with respect to the change of temperature is very close to a linear function, and can be characterized by a temperature coefficient α. The temperature coefficient for that material is D. T. Holmes & K. K. Sum 5

defined as being that fraction of the resistance at 0 C by which its resistance changes for each Celsius degree change in temperature, i.e., Material α = R t R o R o t ρ (Ohm -meters at 20 C) Aluminum 2.83 10 8 Copper, annealed 1.724 10 8 Copper, hard -drawn 1.77 10 8 German Silver (18% Ni) 33 10 8 Gold, pure drawn 2.4 10 8 Iron, cast 9 10 8 Lead 22 10 8 Mercury 96 10 8 Nickel 7.8 10 8 Platinum 10 10 8 Silver (99.98% pure) 1.64 10 8 Tin 11.5 10 8 Table 1. Resistivities ρ of Selected Conductor Materials 1 1 Values taken from Smithsonian Physical Tables. Where R t is the resistance of the conductor at t C, and R o is the resistance of the conductor at 0 C. Rearranging the above expression yields R t = R o ( 1 +αt) The value of α is a characteristic of the material of the conductor, and the temperature range considered is positive when the resistance increases as the temperature is raised (e.g., pure metals), but is negative for non-metals for which resistance decreases with a temperature rise. From Table 2, the temperature coefficient of copper is approximately 0.4%/ C. Therefore, a 40% increase in resistance corresponds to a temperature rise of 100 C. From a room temperature of 23 C, add another 100 C gives 123 C, which is just a few degrees below 130 C (Class F) requirements. An experiment was performed with direct current passing through a single turn of a #30 A.W.G. (the normal wire used for wire-wrap applications in digital circuits with approximately 100 circular mils in cross section, Kynar insulation) inserted into a loose fit teflon sleeve. The combination of sleeve and wire was inserted into a ferrite block. The current level was adjusted from 0 ampere upwards to obtain a resistance increase in the wire by 40% (100 C rise). After a period of no less than 2 hours stabilization, this current was found to be 6 amperes. D. T. Holmes & K. K. Sum 6

Material (at 20 C) Temperature Coeff. α (Ohms/Ohm/ C) Aluminum.0039 Copper, annealed.00393 Copper, hard -drawn.00382 German Silver (18% Ni).0004 Iron.005 Lead.0041 Mercury.00089 Molydenum.0034 Nickel.006 Platinum.003 Silver (99.98% pure).0038 Tin.0042 Table 2. Temperature Coefficients of Resistance of Selected Conductor Materials This result corresponds to 16.6667 circular mils/ampere. On this basis, it was decided that the current density of 50 circular mils/ampere (3 times the wire cross section area) is very conservative for windings with a small (less than 5) number of turns. In consideration of the conventional transformer design practice, the following table is reproduced from McLyman [2] to identify the current density used in these designs: K j Core Type Losses (25 C) (50 C) (x) K s K w K v Pot Core P cu = P fe 433 632 0.17 33.8 48.0 14.5 Powder Core P cu P fe 403 590 0.12 32.5 58.8 13.1 Laminations P cu = P fe 366 534 0.12 41.3 68.2 19.7 C -Core P cu = P fe 323 468 0.14 39.2 66.6 17.9 Single -Coil P cu P fe 395 569 0.14 44.5 76.6 25.6 Tape - Wound P cu = P fe 250 365 0.13 50.9 82.3 25.0 J = K j A p (x) A t = K s A p 0.5 K j W t = K w A p 0.75 V ol = K v A p 0.75 Table 3. Relationships Between Core Loss, Core Geometry, and Current Density in Conventional Transformer Design Considerations. D. T. Holmes & K. K. Sum 7

From Table 3, the powder core losses are used for comparison, based on its core geometry similar to that of a regular toroidal core, which is the closest approximation to the cores used for the current flat transformer design. This table was developed using curve fitting technique, based on manufacturers data. In an example of a half-bridge transformer design [8], the current density J was calculated as 559 amps./cm 2. The core used was a PQ core. The current density of 559 amps./cm 2 is the same as 5.59 amps./mm 2, or 5.59 amps./1973 circular mils. This is the same as 2.833249 ma/circular mil, or 352.9517 circular mils/amp. (conventional transformer design). Comparing this number with the conservative flat matrix transformer design of 50 circular mils/amp., and the experimental matrix current density of 16.67 circular mils/amp. The above results can be tabulated in a table as shown in Table 4: Transformer Current Density (Circular Mils/Amp.) Circuit Conventional 353 Half -Bridge Flat Matrix (Conservative) 50 Half -Bridge Flat Matrix (Experimental) 16.67 Half - Bridge Table 4. Current Density Comparison with Conventional Transformer Design Based on these findings, the modules were designed and optimized for low voltage high current applications. This same design philosophy can be applied to design smaller and/or larger modules to accommodate other output voltages and output power levels. Type of Transformer Volts/Turn/Module Waveform %Duty Primary Voltage Conventional 5 Sine V in Push-Pull 10 PWM 50 V in Half - Bridge 20 PWM 50 1 2 V in Full-Bridge 10 PWM 50 V in Forward 10 PWM 45 V in Table 5. Optimized Flat Matrix Transformer Module Design. Summary and Conclusions A detailed description of the design philosophy of the flat matrix transformer module has been given. The experimental results show that the current density of this type of transformer is, conservatively, higher than the conventional transformer by a factor of at least 5. It appears that the key to high power density is not just pushing up the switching frequency, but is also important to have good thermal characteristics as well as high current density. D. T. Holmes & K. K. Sum 8

The flat matrix transformer has modularity, which permit power level flexibility and superior thermal characteristics. Due to the low probable number of primary turns, the current density of the transformer can be increased dramatically beyond the capability of any conventional designs. The advantage of this transformer has been well documented previously [1, 3, 4, 5, 6, 8], and will only be summarized here. The main points are: (i) High efficiency, (ii) High power density, (iii) Low profile, (iv) Simple construction, (v) Low leakage inductance, (vi) High current density, (vii) Modularity and design flexibility, (viii) Distributed heat concentration, (ix) Resistant to shock and vibration, (x) High dielectric isolation, and (xi) Current sharing. The maximum potential of this transformer has yet to be explored and discovered. References: 1. Edward Herbert, Design and Application of Matrix Transformers and Symmetrical Converters, a tutorial presented at the High Frequency Power Conversion Conference '90, Santa Clara, CA, May 11, 1990. 2. C. W. T. McLyman, Transformer and Inductor Design Handbook, Second Edition, Marcel Dekker, Inc., New York, New York, 1988. 3. James Ley Lau, et al, Flat Transformers -- For Low Voltage, High Current, High Frequency Power Converters, Coil Winding, Insulation & Electrical Manufacturing 96, June 4-6, 1996, Berlin, Germany. 4. K. Kit Sum, et al, Novel Low Profile Matrix Transformers for High Density Power Conversion, PowerConversion and Intelligent Motion, September, 1988. 5. K. Kit Sum, et al, A High Density Power Converter Utilizing A Novel Matrix Transformer, Best Paper Award, SATECH 88 Conference, October 3-6, 1988, Dearborn, Michigan, U.S.A. 6. K. Kit Sum, Design and Application of Matrix Transformers, paper presented at the High Frequency Power Conversion Conference '90, Santa Clara, CA, May, 1990. 7. K. Kit Sum and B. Carsten, Trends in High Frequency Power Conversion, paper presented at the High Frequency Power Conversion Conference, San Diego, May 1988. 8. C. W. T. McLyman, Designing Magnetic Components for High Frequency dc-dc Converters, KG Magnetics, Inc., San Marino, California, 1993; Example #302, page 79. 9. U. S. Patent Nos: 4,665,357; 4,845,606; 4,942,353 and/or 5,093,646. Others pending. Demonstration kits are available from: Flat Transformer Technology Corporation, 240-250 Briggs Avenue, Costa Mesa, California 92626, U.S.A. Telephone: (714) 850 7320, Facsimile: (714 ) 850 7321. D. T. Holmes & K. K. Sum 9