OpenLAB CDS ChemStation Edition Overview Jon Welsh Agilent Informatics 1
How Does OpenLAB CDS ChemStation Edition Address Other Lab Needs? An Enterprise-wide Chromatography Data system Fully scalable from stand-alone workstation to Distributed System Easily connects to Data Store or ECM for central data storage and regulatory compliance with GLP/GMP and 21 CFR Part 11 Multi-technique: Control of Agilent GC, LC, CE, LC/MS, CE/MS, SFC Tight instrument integration Flexible report generation tools for custom calculations, sequence summary and single run reporting Macro language Page 2
OpenLAB CDS Workstation Configuration Page 3
OpenLAB CDS: Networked Workstation Configuration Page 4
OpenLAB CDS: Fully Distributed Configuration Page 5
OpenLAB CDS ChemStation Edition A Scalable Part of the LI Family Features All Data and Methods generated by any version of ChemStation rev. B are compatible. The UI and workflow of OpenLAB CDS is very familiar and doesn t change in scaling or adding Data Store or ECM for storage. Benefit Customers have a smooth migration path from single workstation to a Networked System with or without Data Store / ECM. Page 6
Multi-Technique Instrument Control Many Instruments - One Enterprise Software One user interface Lab-at-a-glance view of the lab Identical look & feel independent of the hardware Easy to learn and use Central administration Central place to configure data storage Page 7
Roles & Privileges ChemStation roles and privileges are managed in OpenLAB Control Panel and can be used without OpenLAB ECM or Data Store. Support for local and domain user authorization. Grouping of instruments into locations. Define access security for each location in the tree. Page 8
Data Organization What s in a Result Set? The master method is copied at the start of the sequence to create a sequence method. Any changes made during data analysis (e.g., during an update of the calibration table) are saved into the sequence method. The acquisition method is stored in ACQ.txt. The individual Data Analysis Method (DA.M) preserves the last data analysis parameter to re-create the last version of the results for a specific data file. Page 9
Usability: Introducing Workflows Review View ChemStation Review View Uses Intelligent Reporter to show results Data Analysis View Recalculation Mode - Flexible Recalculate peak results in the navigation table with one or several different methods Shortcut to recalculate all data in the navigation table with a single method Manually step through navigation table or use auto-stepping to review Reprocessing Mode - Traceable Reprocess the sequence with different method(s) to update or modify calibration Add new or changed methods to result set and reprocess the whole or partial sequence Store and manage all result and method revisions with sequence/result set Page 10
Review View Select report template(s) and data-files and get immediately answers on complete experiments! Key Benefit: Preview or print reports without reprocessing and get your reports 10 times faster! Page 11
Recalculate Mode Any method can be loaded from the tree Recalculate menu Switch between Recalculation and Reprocessing Mode autostepping toolbar Key benefit: quickly apply multiple methods to a self-defined set of runs Page 12
Reprocess Mode New tree with current sequence methods; quickly add master methods to the result set Switch between modes sequence reprocessing toolbar Key benefit: Easy way to reprocess and recalibrate complete sequence Page 13
Self-Assembled Data Sets and Result Sets Self-assembled Data Set Use Add functionality to add data from different sources Reprocess/recalculate and report over self-assembled set of data assembled from different folders [not possible in strict 21 CFR part 11 workflow!]. Self-assembled Result Set A self-assembled data set can be turned into a self-assembled result set. Always available for cross-sample calculations and uploading into Data Store or ECM. Supports cross-sequence review in 21 CFR part 11 workflow Page 14
Self-Assembled Result Set Select data files in the navigation table Launch Create New Result Set dialog Select the method and destination folder Page 15
Sequence Queuing The Run Queue now also supports ChemStation sequences. You can directly schedule a single sequence, or process all sequences given in a Queue Plan. Select a sequence template to be added to the queue (online only) Page 16
Run Queue Single Samples can now be added to the Run Queue. Run Method / Run Sequences are submitted to the queue. Page 17
Queue Planner The Queue Planner allows setting up the relevant sequences and queueable pauses in a queue plan Load, create and save queue plans (as *.qpl file) Available in online and offline Easy Sequence Queueable pause Native Sequence Page 18
METHOD HANDLING OpenLAB CDS ChemStation Edition Page 19
Method Download Upon instrument startup, users are given a choice: download the ChemStation method to the instrument upload the instrument method to ChemStation create a new method from instrument method A differences viewer highlights the differences between the ChemStation method and the instrument method.
OpenLAB CDS ChemStation Edition Acquisition Method Viewer Problem I need to review the Acquisition Method parameters before downloading to the instrument. I do not want to trigger Method Resolution. Solution Acquisition Method Viewerprovides a way to view the acquisition method parameters. Page 21
OpenLAB CDS ChemStation Edition Single Sample Workflow The Navigation Table now shows the acquisition method as well as the data analysis method. A fly-over indicates the path to the data analysis method. Page 22
OpenLAB CDS ChemStation Edition STORAGE OPTIONS
Storage Option Review File System Simple configuration supports Workstation and Networked Workstation Data Store Compliant workgroup solution: Compliance with GLP/GMP and 21 CFR part 11 Includes sophisticated search support ECM The Enterprise data repository Compliance with GLP/GMP and 21 CFR part 11 Includes sophisticated search support Page 24
OpenLAB CDS ChemStation Edition Integration with Data Store or ECM Download any result set or single run from Data Store (or ECM) to the local ChemStation file system. The downloaded data can be reviewed and reprocessed, since the result set contains all necessary files. Data that have been uploaded to Data Store (or ECM) have a different icon in the tree view. Page 25
For more Information Title: Agilent OpenLAB CDS efamiliarization DVD P/N: M8301-60032 This DVD includes a set of efamiliarization modules for OpenLAB CDS ChemStation and EZChrom Editions Literature Type: DVD Language: English (currently shipping) Chinese & Japanese (ships in Feb. 2014) Target Audience: Agilent customers who need basic overview of the software operations and functions. OpenLAB CDS ChemStation Edition web page Page 26
What s New in OpenLAB CDS A.01.06 Support for Windows 7 and 8 Improvements to sequence handling Refreshed Sequence Table [CS] Full sequence rollout [CS] Targeted Customer & Support Enhancements Improved bar code handling [CS] Recoverable error handling for GC Intelligent Reporting Updates OpenLAB Data Analysis A.01.02 Expand support for HPI Integration with Data Store Integration with OpenLAB Data Store A.02.01 Expansion of database compatibility to PostgreSQL OpenLAB CDS Secure ChemStation Workstation Improved display of driver versions Instrument Control [CS] = ChemStation Edition [EE] = EZChrom Edition 27 OpenLAB CDS A.01.06 Agilent Restricted November 2013
Customer Experience Stop the GC and Continue the Sequence Recoverable error handling Continue Abort and Continue Queue Abort Skip Pause Abort and Continue Queue Abort 28
Customer Experience Improve customer experience of ChemStation sequence table [CS] Sequence rollout [CS]
Barcode Reading Chain of Custody Enter sample information including the sample name into the sequence table 7693 ALS with 7890B reads barcode CDS compares the Barcode field (Actual) to the sample name (Expected) and determines mismatched values Logic determines whether to inject or not and prints results on the reports True = prints barcode match False = prints barcode mismatch 30 ChemStation Edition June 19, 2013