The. Advantage ,000 cfm Supplemental Heating & Cooling

Similar documents
Bring the fresh in. Dedicated Outside Air Systems

CE6500 Energy Recovery Ventilator

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

RPV - RP - RA air handling units

Mechanical Rooftop Custom Capabilities

Innovent LASER Packaged Fresh Air Conditioning Units

HIGH EFFICIENCY RTU. HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

Element D Services Heating, Ventilating, and Air Conditioning

Johnson Air-Rotation Systems

SECTION HEAT PUMPS

Glossary of Heating, Ventilation and Air Conditioning Terms


SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION MORTUARY REFRIGERATORS

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

HVAC Basic Science - System Capacity

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

HVAC Processes. Lecture 7

Advanced Energy Design Guide LEED Strategies for Schools. and High Performance Buildings

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

Variable Air Volume - VAV

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

ECOCIAT. Domestic hot water heat recovery unit

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

What is LEED? Why pursue LEED accreditation? How does LEED accomplish these goals? Sustainable sites Water efficiency Energy and Atmosphere

Energy Efficiency in Industrial HVAC Systems

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

york air-conditioning products Residential & VRF News 2015

How To Get A Passive House

Maintenance for Energy Efficiency

Zehnder Focus 200. Ventilation device

Ventilation Solutions Fresh Air Solutions for Ductless Heating & Cooling. fantech

By Tom Brooke PE, CEM

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

Fans and Air Handling Units. Will Rea and Paul Pilutti February 16 th, 2011

Answers to Your Questions from the Webinar

Failure code manual. content

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

HVAC Costs. Reducing Building. Building owners are caught between two powerful forces the need to lower energy costs. By Stephen J.

Commercial Gas Furnace Upflow

HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow

HP switch LP switch Discharge thermo Comp. Surface thermo

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

ARMSTRONG AIR HEAT PUMPS

Digi-Motor Installation Guide

SWIMMING POOL HEAT PUMP

USER MANUAL HRV CONSTRUCTO 2.0ES* HRV CONSTRUCTO 1.5ES* * THESE PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY

PMI-IF-H High Efficiency Gas Heat Units

Installation and maintenance instructions. Danfoss Vent

Ventilation Solutions Kitchens. fantech

Why is my air conditioner dripping on my customers?

Dehumidification Frequently Asked Questions

Modular Make-Up Air Unit

Operation and Installation Manual. Max Series

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Chilled Beam Solutions ADVANCING THE SCIENCE OF AIR DISTRIBUTION. Redefine your comfort zone.

Air Conditioning System

Carnegie Mellon University School of Architecture, Department of Mechanical Engineering Center for Building Performance and Diagnostics

DOAS UNITS. MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR. Kitchens Hotel Corridors Laboratories. Paint Booths. Capacities Tons MBH

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

Lesson 36 Selection Of Air Conditioning Systems

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

SECTION AIR CONDITIONING UNIT

catalog Single Package Vertical Air Conditioners and Heat Pumps

Why Daikin? 2015 Houston, Texas USA

Single Package Vertical Air Conditioners. Vert-I-Pak

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA

Direct Fresh Air Free Cooling of Data Centres

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL W70A1 W70L1. Models: Contents. General Notes. Important. Description

MULTIZONE APPLICATION OF SOLUTION UNITS

Drives and motors. A guide to using variable-speed drives and motors in retail environments

How To Design A Building In New Delhi

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE

Energy Efficiency. Energy Efficient Home Cooling:

squrboxbox heat recovery squrboxbox I technical information

Creating Efficient HVAC Systems

2 STEPS TO CONDUCTING YOUR HVAC ASSESSMENT

UNIFIED FACILITIES GUIDE SPECIFICATIONS

HVAC Systems in Schools & Commercial Buildings and Radon

TWE+TTA TWE+TWA T.R.

Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment

Printing and Publishing Energy Savings Guide

HVAC Systems: Overview

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

SAM HOUSTON STATE UNIVERSITY

SECTION GENERAL PROVISIONS FOR HVAC WORK

Statement of Work. 3.0 Details of Service Pre Start-up Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary

State of the Art Energy Efficient Data Centre Air Conditioning

Transcription:

R GO GREEN GO RUSKIN The Advantage 600 12,000 cfm Supplemental Heating & Cooling

Regardless of building type or rating system, today s building must be as energy efficient as possible. The design of the HVAC system is critical to the success of the building s energy performance. Proper ventilation for occupant health and productivity must also be addressed. The quality of the indoor environment cannot be sacrificed for the sake of energy efficiency. EnERVent+ TM by Ruskin is your solution. Increased ventilation rates in combination with energy recovery products not only improve the indoor air quality but also reduce the cost associated with conditioning these larger amounts of outdoor air. Benefits of Energy Recovery Energy savings provide exceptional payback Investing in energy recovery wheels in HVAC systems can provide quick payback in two areas. Initial cost savings can be achieved on main air handling units by reducing cooling load. Application software is available to calculate the load reductions and provide the energy and dollar savings in most areas of the United States and Canada. Annual savings are achieved by preconditioning the outdoor air. LEED-EB and LEED-NC Credits For Green Building designs, the EnERVent+ can assist the designer in acquiring credits for Energy and Atmosphere (EA) by optimizing energy performance and for Indoor Environmental Quality (IEQ) by providing the ability to increase ventilation leading to thermal comfort. ASHRAE Compliance and IAQ ERV s are an excellent choice to comply with outdoor ventilation requirements of ASHRAE 62. Introducing fresh, outdoor air to a building is a key component in sustaining excellent IAQ and occupant productivity. ERV s meet the minimum requirements for energy savings per ASHRAE 90.1 and will be a preferred method for saving energy in ASHRAE/USGBC/IESNA's new Standard 189.1 Standard for the Design of High Performance, Green Buildings Except Low-Rise Residential Buildings.

n Standard Design Features Additional Design Choices Motorized Intake and Exhaust Dampers Ruskin s motorized dampers seal tight when the ERV is not in operation. These options are fully factory wired to EnERVent+ s control system. n Powered by Lau Silent Pro Series forward curved blowers with isolation to reduce noise and vibration. n Double wall construction with 1" fully insulated galvanized steel panels. n 2" MERV 8 filters come standard for both the intake and exhaust sections of EnERVent+. MERV 13 filters also available on LEED/Green projects. n Digital control box that allows for integration with automated building control systems. Pre-heat Frost Control n Enthalpy Energy Recovery Wheel Optional Sensible Only Optional Purge Section Coil Options Chilled Water (Shown) Hot Water Split DX 4 Pipe, both Chilled and Hot Water n Heavy duty double constructed insulated bottom to help ensure rigidity during transit and installation. Post Heat Staged Electric Heater Indirect Gas-Fired Heater Optional Horizontal Discharge n Single point wiring with fused NEMA 3R disconnect switch and low voltage strip for easy installation. Electric pre-heat and post-heat require field installed power. n Hinged panel access doors, with quarter turn latches, allow easy access to energy recovery wheel, coils, filters and blowers.

Product Features Standard Design Features n Double wall construction with 1" fully insulated galvanized steel panels. n Heavy duty double constructed insulated bottom to help ensure rigidity during transit and installation. n Powered by Lau Silent Pro Series forward curved blowers with isolation to reduce noise and vibration. n Single point wiring with fused NEMA 3R disconnect switch and low voltage strip for easy installation. Electric pre-heat and post-heat require field installed power. n Hinged panel access doors, with quarter turn latches, allow easy access to energy recovery wheel, coils, filters and blowers. n 2 MERV 8 filters come standard for both the intake and exhaust sections of EnERVent+. n Digital control box that allows for integration with automated building control systems. n EnERVent+ incorporates a new electronic technology for rotation sensing that sends a signal when the energy recovery wheel stops turning. Additional Design Choices Frost Control Blower Cycle Frost Control (Low Ambient Kit) This option cycles the intake blower on and off based on an exhaust air temperature set point. The lower volume of incoming air allows for the recovery wheel to defrost. VFD Frost Prevention A Variable Frequency Drive is used to slow down the energy recovery wheel RPM when the exhaust temperature decreases to a set point. This reduces moisture on the energy recovery wheel being exposed to outside air and therefore controls the frost. VFD frost control is available for EVT-62, EVT-88 and EVT-120. Pre-heat Frost Control This ensures continuous operation in cold environments by tempering the incoming air with up to 32.4 kilowatts as frost inducing temperatures are reached. EnERVent+ incorporates closed element pre-heat coils with a high temperature baked on aluminum or Incoloy coating to allow for extended life in a 100% fresh air stream. EAMP Air and Temperature Direct Measuring This Ruskin exclusive option provides digital air and temperature readouts from the intake and exhaust sections of the EnERVent+. Output is displayed digitally on the included controller with additional output available for a building automation control system. EME Intake Louvers Ruskin EME louvers incorporate the latest technology in wind driven rain louvers that have proven to be 100% effective in preventing water penetration during 50 MPH winds and 8" per hour rainfall rates. VFD Blower Control Variable frequency drives (VFD) control the speed of EnERVent+ s blowers. VFD s can be integrated with your building s automation system to maximize efficiencies and deliver precisely the amount of air needed. Free Cooling Mode (Stop, Start and Jog) Optional economizer controls allow free cooling when the outside air reaches a designated set point. Electronic Temperature Control System This works in conjunction with optional heating and cooling coils to temper air entering the occupied space back to ambient. Tempering the air entering the occupied space allows EnERVent+ to bring in 100% outside air without putting an additional load on the rooftop unit. The Electronic Temperature Control System can be integrated with a building automation system. ERC Sensible Only This incorporates our standard Energy Recovery Cassette (wheel) without the desiccant coating. Typical applications for sensible only wheels include areas with high internal humidity such as pools, locker rooms, and saunas. MERV 13 filters also available on LEED/Green projects. unit available with either down discharge or horizontal discharge. Smoke Detectors Duct mounted smoke detectors can be installed in both return and/or supply air streams. Signals from these smoke detectors can be set to start-up or shut-down the EnERVent+ unit if smoke is detected. CO 2 Sensor A CO 2 sensor option helps control indoor air quality based on CO 2 levels in the occupied space. High CO 2 levels can either trigger a response from the EnERVent+ unit by turning on the blowers to bring in fresh air or by modulating the blowers if a VFD option has also been selected. Dirty Filter Sensor The dirty filter sensor sends a signal to field wired alarm when filters need to be cleaned or changed. Roof Curbs Optional 14", 18", or 24" high roof curbs are available. Remote Panels EnERVent+ s control system is capable of outputting signals to a variety of optional remote display panels. Replacement Wheel Segments Pie shaped wheel segments are available for replacement so the entire wheel does not have to be replaced if a segment gets damaged. Custom Paint Send Ruskin your color requirements for an optional custom paint match. GFCI Service Outlet Optional field wired service outlet provides power for service equipment. New Option EnERVent+ heating & cooling CHOICES Indirect Gas-Fired Post Heat 2 Stage Indirect Gas Heat is available with up to 500 MBTUH to provide supplemental heat for supply air exiting the EnERVent+ unit. Electric Post Heat Staged electric heat is available with up to 120 kilowatts to provide supplemental heat for supply air exiting the EnERVent+ unit. Chilled Water Chilled water coils work in conjunction with chillers to cool the supply air exiting the EnERVent+ unit. Hot Water Hot water coil work in conjunction with hot water to heat the supply air exiting the EnERVent+ unit. 4 Pipe Water Coil Combination of chilled water coil and hot water coil each with their own independent connections. DX Coils DX coils work with split system condensing unit using R410a refrigerant to cool the supply air exiting the EnERVent+ unit. All DX coils will have rifled tubing to increase efficiency.

Specifications D A E B C SIDE VIEW TOP VIEW Dimensions (Inches) Base Unit Model A B C D E Weight (lbs) EVT-010 / EVT-019 77 43 45 15 10 1350 / 1500 EVT-028 / EVT-036 98 53 55 19 14 2350 / 2500 EVT-046 / EVT-062 116 66 68 23 18 2700 / 3000 EVT-074 / EVT-088 135 77 79 25 20 4700 / 5000 EVT-100 / EVT-120 144 87 88 28 22 5600 / 6000 Dimensions (inches) Units that require any of the following options: Field Convertible Horizontal Discharge, Gas Heat, or 4 Pipe Water Coil Model A B C D E Weight (lbs) EVT-010/ EVT-019 94 47 52 15 10 1510 / 1670 EVT-028 / EVT-036 109 54 61 19 14 2610 / 2780 EVT-046 / EVT-062 131 67 74 23 18 3080 / 3330 EVT-074 / EVT-088 150 77 89 25 20 5210 / 5560 EVT-100 / EVT-120 162 88 101 28 22 6230 / 6670 Performance Model EVT-010 EVT-019 EVT-028 EVT-036 EVT-046 EVT-062 EVT-074 EVT-088 EVT-100 EVT-120 CFM Range Supply Motor HP Exhaust Motor HP External Static Supply (in.wg) External Static Exhaust (in.wg) Min 600 900 1600 2400 3000 3400 5400 6400 7600 8000 Max 1000 1900 2800 3600 4600 6200 7400 8800 10000 12000 Min 1 1 1.5 2 2 3 3 5 5 7.5 Max 1.5 2 3 5 5 7.5 7.5 10 10 15 Min 1 1 1 1.5 2 2 3 5 3 5 Max 1.5 2 2 3 5 5 7.5 10 7.5 10 *Max 1.5-3.0 1.5-3.0 1.5-3.0 1.5-3.0 1.5-3.0 1.5-3.0 1.5-3.0 1.5-3.0 1.5-3.0 1.5-3.0 *Max 1.5-3.0 1.5-3.0 1.5-3.0 1.5-3.0 1.5-3.0 1.5-3.0 1.5-3.0 1.5-3.0 1.5-3.0 1.5-3.0 * Max external static pressure depends on the options selected. R Air & Sound Control Specified by Many Equaled by None 3900 Dr. Greaves Rd., Kansas City, MO 64030 (816) 761-7476 n Fax (816) 765-8955 n Email: ruskin@ruskin.com n www.ruskin.com Enervent+B 912/New