MCS 100 E HW/PD/CD Multi-Component Analysis System

Similar documents
EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Online Infrared Flue Gas Analyzer Gasboard 3000

DUST EMISSION MONITORING SYSTEM

Any potential user should ensure in consultation with the manufacturer that this AMS is suitable for the installation on which it will be installed.

Material test chamber with mechanical convection

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: GM32 ln-situ-gasanalysator model Cross Duct for NO and S02

Product Information Sheet UH36 Hi Pot Tester

Certificate: _01 / 29 April 2014

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

Advanced Solutions for Gas Monitoring

Duct Humidity Transmitter

Certificate: / 20 August 2013

Emission Monitoring and Reporting (EMR) Guidelines for Continuous Emissions Measurements in Holcim Cement Plants

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

S300 Series Dust Monitors

Incubator with mechanical convection

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Permissible ambient temperature Operation Storage, transport

Product Information Fire alarm panel 8000 C

Vacuum drying oven for non-flammable solvents

Adsorption air dryers ADS 1 215

SO 3 -Monitoring in Flue Gas of a Power Plant Application & Results

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

Kompressoren. Adsorption Dryer AD

Heating oven with mechanical convection

Highly efficient flue gas analyzer

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

ThermoSorb Desiccant Dryers

ABB PSPS Erich Steinmann; Generator control-2013

RRV934. Multi-controller. Synco living

Heating oven with mechanical control

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

Cooking at the Speed of light!

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

COMBIMASS. Technical Data COMBIMASS eco-bio +

API Marine. BMS Presentation. Ballast Measurement Systems

Any potential user should ensure in consultation with the manufacturer that this AMS is suitable for the installation on which it will be installed.

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Combi switchbox with integrated 3/2 way pilot valve

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

Hydraulic Control Solutions

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Spetec. Laminar Flow Box. Portable Clean Room Technology

Digital input modules

Monitoring Air Emissions on Ships. Restricted Siemens AG 2014 All rights reserved.

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

DLO1191 Linear smoke detector

WEATHER STATION FOR SOLAR FARM MONITORING

Rotary screw compressors kw 5,5 7, , bar MODULO

PIEZOMETER AIRFLOW MEASURING RING

ABB central inverters PVS to 1000 kw

How To Use A Ds340 (Dsp)

Power consumption (kw)

DRYPOINT AC HP PREMIUM HIGH-PRESSURE DRYING

Bulk Flow Meter LB 442 P R O C E S S C O N T R O L

Technical Information RIA14

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

CO Low CO High O 2 NO NO 2 NOx SO 2 H 2 S CxHy CO 2 LANCOM III

HCR3.2/.. Chipcard reader HOTEL SOLUTION

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

WEB log. Device connection plans

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Advanced gas analysis kept simple

Refrigeration Compressed Air Dryer Buran Ultrapulse

HERZ-Thermal Actuators

Climate chamber with illumination

Electric Rotary Actuator - On/Off or programmable control actuator

Pneumatic control loops save water and energy with fixed-bed filters

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

Environmental Automated Measuring Systems for Flue Gas

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Air Pollution Control Division. Technical Services Program

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Temperature. LumaSense Technologies, Inc. supplies a unique selection of very precise calibration

OZW30. Central Unit SYNERGYR

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

NC-12 Modbus Application

Application Requirement

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

The new generation: WLL180T photoelectric sensor with fiber-optic cable. Around the corner at High Speed

READING DEVICE US-05

ADU 5. Automatic Distillation Unit

Quick Connect. quick - simple - efficient.

LOGO! Logic module. Brochures For brochures serving as selection guides for SIMATIC products refer to: printmaterial

Digital inductive conductivity transmitter

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

AMTRON E-30 Compact heat and cooling meter

Multifunction devices

Repeaters and Mimics Data Sheet

ThermoStar Refrigeration Air Dryers

TX OPEN RS232/485 module

2.24. Pump Controller 704. Data Sheet

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Transcription:

P r o d u c t I n f o r m at i o n MCS 100 E HW/PD/CD Multi-Component Analysis System Analysis Systems for Continuous Flue Gas Monitoring Tailored to Your Needs Analyzers and Process Instrumentation

Analysis Systems for Flue Gas Monitoring Continuous Flue Gas Monitoring Tailored to Your Needs For industrial plants to run efficiently, raw gas/exhaust air monitoring and process control require reliable andcost-effective measuring systems. Applications Power plants Refuse incineration plants Steel production Cement industry Industrial air extraction systems The MCS 100 E HW, MCS 100 E PD and MCS 100 E CD measuring systems fulfill these requirements in a very unique way. Based on the flue gas analyzer MCS 100 E, they can be adapted to specific applications to handle a range of continuous flue gas monitoring tasks. SICK MAIHAK also designs everything from complete flue gas analysis systems to preinstalled, accessible analysis containers. A solid platform as a basis for tailormade measuring technology Tried-and-tested extractive measuring technology The MCS 100 E HW/PD/CD measuring systems work by extracting part of the flue gas and feeding it to the MCS 100 E analyzer. A high sample gas flow rate of >400 l/h ensures fast response times and minimizes memory effects and delays. The sampling device is adapted to the conditions of the sampling point. Reliable, flexible systems The systems consist of a cabinet, analyzer, measuring gas cooler or permeation dryer, measuring gas pump as well as the complete temperature monitoring system including external components. They are self-monitoring, perform zero balancing (and, if required, calibration) automatically, and output the appropriate status signals. If a fault occurs, the system automatically switches to standby mode and flushes the sample and cell of corrosive flue gas. Example of an MCS 100 E HW system cabinet Fail-safe interfaces Measured values and status signals can be picked off on module boxes. These include digital/analog inputs and outputs which are suitable for connecting external analyzers for total carbon, dust and Hg (mercury), for example. Data acquisition equipment, printers or modems can also be connected to the system. Modbus protocol is supported; PROFIBUS and Foundation Fieldbus are available on request. Complete heating and temperature monitoring The MCS 100 E systems monitor probes, filters, gas ducts and all internally-heated components as standard. Barometric correction The systems can be expanded to incorporate a pressure sensor that corrects the test result to take account of fluctuations in the atmospheric pressure. Convenient operation and easy maintenance The operating status is indicated by means of three lamps (operation, fault, maintenance) on the front door which also includes a maintenance switch and the main switch. The maintenance interval approved by TÜV (authorized inspection agency) is three months.

F2 F1 F3 ESC 0 1. 7 2 8 3 6 9 F8 MCS 100 E Analyzer: Overview The MCS 100 E Analyzer Powerful yet Compact Intelligent analyzer The MCS 100 E analyzer features a photometer, cell, control computer and user interface with keyboard and monitor. An integrated flow meter monitors the sample gas flow rate. An oxygen probe (ZrO 2 ) can also be installed. All parts in contact with the measuring gas can be heated to prevent cooling below the dew point. The MCS 100 E controls and monitors flue gas measurements. The values determined are displayed on screen, stored on the computer and transmitted to the interfaces integrated in the system cabinet via light guides. Photometer many components, optional calibration filter The photometer is a single-beam infrared device which enables bifrequency and gas filter correlation procedures to be used simultaneously. Two important features of the light source (an infrared emitter) are its high energy output and long service life. The light emitted passes through the chopper wheel, the cell, the two filter wheels with the interference and gas filters, and impinges on a pyroelectric detector. An optional calibration unit enables the selected sensitivity to be checked quickly. Cell: Long optical path, low volume, adjustable temperature The optical path of the cell (3 or 6 m/10 or 19.7 ft) is permanently set via the mirrors cut into the end faces. The cell has been optimized to minimize volume and maximize gas exchange. It can be set to temperatures of up to 200 C/392 F (optionally up to 225 C/437 F). The gas inlet is fitted with a protective filter. Integrated flow meter The measuring gas flow is monitored by an integrated flow meter which measures differences in temperature between still and flowing gas. An alarm sounds if a settable limit value is undershot. Integrated O 2 measurement with high stability and long service life The MCS 100 E also features an optional oxygen measurement. Part of the flue gas is removed at the cell outlet and fed to a zirconium oxide probe (ZrO 2 ) in the bypass. The ambient air serves as a reference. The electrical signal is analyzed in the computer. The ZrO 2 probe is highly stable and has a long service life. MCS 100 E Analyzer Components User interface Filter wheel 2 Calibration unit Filter wheel 1 MCS 100 E F3 F3 F3 F3 4 5 Flow meter ENTER Detector Computer unit Light source Optical interfaces Chopper wheel Gas outlet Gaseingang Cell Filter O 2 sensor Mirrors

Analyzer, Computer and User Interface: State-of-the-Art Technology Measured values displayed as a time characteristic Integrated system control in the MCS 100 E analyzer The computer integrated in the MCS 100 E analyzer is IBM compatible with a DOS user interface. A silicone disc (with no moving parts) serves as a bulk memory. The computer controls the measurement procedure, processes measured values, monitors limit values and outputs the results, warnings and alarms to the monitor and the interfaces. The illuminated LC monitor and touch-sensitive keyboard are splash-proof and located on the front of the device. Connecting an external keyboard is very convenient thanks to a socket on the front of the unit. User-friendly software: two levels with password protection The software for operating the MCS 100 E is menu driven and features two levels: one for the measuring mode and another for password-protected configuration changes. Measured value display/ data backup All measured values are displayed together with status messages either numerically or graphically on the monitor as a concentration characteristic. The graphic display can be tracked and the status messages called up via the bulk memory. Via light guides to the system: flexible and reliable The signals generated are transferred via two optical interfaces and connected light guides to the module boxes in the cabinet. These form the interfaces to the process. The analog measured values and digital status signals can then be picked off and the external signals read. The fiber-optic cable concept supports flexible system design and ensures electromagnetic interference immunity. 4

Overview of the Systems Custom-Made Solutions for a Wide Range of Measuring Tasks MCS 100 E system variants MCS 100 E HW with high-temperature measuring technology standard application in refuse incineration plants MCS 100 E PD with permeation dryer for extremely small measurement ranges for SO 2 and HCl in power plants and refuse incineration plants MCS 100 E CD with gas cooler the specialized solution for applications in power plants Features Continuous monitoring of up to eight gas components plus O 2 Easy to use, reliable and robust Automatic zero monitoring Automatic test gas function (optional in certain cases) Internal calibration standard Low maintenance MCS 100 E System HW (high-temp. meas. tech.) PD (permeation dryer) CD (gas cooler) Applications Power plants Refuse incineration plants Steel production Cement production Industrial air extract. systems Federal German Pollution Control Act (13 th /17 th Impl. Ordinances) and raw gas applications Features Standard system for raw and clean gas monitoring Temperature monitoring of all heated components Minimum adsorption and desorption effects Meas. point switchover Corrosion-protected measuring gas cell due to high temp. (185 220 C/365 428 F) Components HCl, SO 2, CO, NO, NH 3, H 2 O, CO 2, O 2 and other IR-active gases Approvals TA air act, 13 th /17 th BImSchV *), EPA, GOST, MCert Power plants Refuse incineration plants Steel production Crematoriums Industrial air extract. systems Also for requirements beyond the Federal German Pollution Control Act (13 th /17 th Impl. Ord.) Extremely small measurement ranges Guarantee value monitoring Minimum adsorption and desorption effects Corrosion-protected measuring gas cell due to high temperatures (185 220 C/ 365 428 F) HCl, SO 2, CO, NO, NO 2, CO 2, O 2 and other IR-active gases TA air act, 13 th /17 th BImSchV *), MCert **) *) Federal German Pollution Control Act (13 th /17 th Implementing Ordinances Power plants Steel production Cement production Crematoriums Industrial air extraction systems Emissions monitoring Standard measuring technology Extremely small/diverse measurement ranges NO 2 measurement without catalyst Corrosion-protected measuring gas cell due to high temperatures (185 220 C/ 365 428 F) SO 2, CO, NO, NO 2, CO 2, O 2, N 2 O, CH 4 and other IR-active gases GOST 5

MCS 100 E Systems The MSC 100 E HW System with High-Temperature Measuring Technology The MCS 100 E HW with high-temperature measuring technology is the standard solution for flue gas monitoring in refuse incineration plants according to the Federal German Pollution Control Act (17 th Implementing Ordinance) use in refuse incineration plants and power plants with high acid dew points It is deployed not only on the raw gas side for process monitoring, but also on the clean gas side for emissions monitoring. High-temperature technology for all components All components of the MCS 100 E HW that come into contact with the measuring gas are heatable and, therefore, protected from cooling below the dew point and the corrosion associated with it. Although the flue gas is cleaned of dust at the sampling point, its composition is, on the whole, not changed. Components such as HCl, SO 2, CO, NO, NH 3, H 2 O and CO 2 can, therefore, be measured. Further IR-active components can also be applied. The heated measuring gas pump is located in the MCS 100 E HW system cabinet. The pump draws the flue gas via the sampling device and the heated flue gas line into the system cabinet and forces it through the analyzer. In order to minimize the adsorption and desorption effects of HCl and NH 3, the analysis system is designed to handle a high flow rate of approximately 600 l/h (21 ft 3 / hrs). The outlet line for the measuring gas is usually not heated. A precipitation collector with automatic fill-level monitoring is recommended depending on the installation location. Instrument air: Zero gas MCS 100 E HW analyzer cabinet Control Backflush Analyzer MCS 100 E Measuring gas outlet Probe Sampling filter Heated test gas line Heated meas. gas pump Test gas 6

The MSC 100 E PD System with Permeation Dryer The MCS 100 E PD system (with permeation dryer for drying gases) is designed for recording extremely small measurement ranges in power plants and refuse incineration plants, for example for very low limit values or for monitoring guarantee values for flue gas cleaning. The legal measurement ranges are, in certain cases, significantly lower than required by the Federal German Pollution Control Act (17 th Implementing Ordinance). Small measurement ranges due to dry flue gas The MCS 100 E PD is also equipped with a measuring gas pump that feeds the flue gas via a heated sampling point and heated extraction line to the measurement system. A permeation dryer is located downstream of the measuring gas pump where the flue gas is dried. This enables extremely small measurement ranges of SO 2 and HCl concentrations as well as further components such as NO 2 to be recorded. H 2 O und NH 3 are not measured here. The MCS 100 E PD requires relatively clean flue gas. In order to minimize the adsorption and desorption effects, the entire sampling system is designed to handle a high flow rate. A dew point measurement corrects the cross sensitivity resulting from residual moisture and does away with the need for a moisture sensor. Instrument air: Zero gas Control Backflush Sampling filter MCS 100 E PD analyzer cabinet Analyzer MCS 100 E Measuring gas outlet Probe Test gas Heated meas. gas line Heated meas. gas pump Permeation dryer Purging gas outlet The MSC 100 E CD System with Gas Cooler The MCD 100 E CD with integrated measuring gas cooler is ideal for performing operational measurements in power plants. It conforms to the Federal German Pollution Control Act (13 th Implementing Ordinance) and can record further components such as NO 2 without the need for a converter. Small measurement ranges downstream of the gas cooler The MCS 100 E CD uses an unheated measuring gas pump to draw the flue gas into the measuring system via a heated sample, a heated extraction line and a gas cooler. The flue gas is dried in Sampling filter the gas cooler and the condensation that accumulates is discharged. Smaller measurement ranges can, in certain cases, also be achieved with this measuring technology in comparison with high-temperature measuring technology, allowing additional components such as NO 2 to be measured. H 2 O and water-soluble components such as HCI Instrument air: Zero gas Control Backflush and NH 3 are not measured here. In order to minimize dead time, the entire sampling system is designed to handle a flow rate of >400 l/h (14 ft 3 /hrs). A dew point measurement corrects the cross sensitivity resulting from residual moisture and does away with the need for a moisture sensor for monitoring the cooler. MCS 100 E CD analyzer cabinet Analyzer MCS 100 E Measuring gas outlet Probe Test gas Heated meas. gas line Meas. gas pump Meas. gas cooler Condensate outlet 7

Technology with a System Accessories, Options and System Technology Measurements at multiple measuring points The measuring systems can be configured relatively easily to allow measurements to be performed at additional measuring points. The MCS 100 E controls measuring point switchover via pneumatic valves in the heated sampling probe. Additional analyzers Further analyzers such as an FID can be integrated in the system cabinet. A paramagnetic O 2 analyzer can be built into the systems instead of the integrated ZrO 2 oxygen sensor. Special versions The systems are housed in steel cabinets as standard. For outdoor installation, the systems are also available with glass-fiber-reinforced plastic housing and internal climate control (on request). The systems can be used safely with measuring gas lines of approximately 100 m in length. Transportable systems in modular units are suitable for portable use. Portable MCS 100 E HW OMD 41 Dust Additional components MCS 100 E HW/PD/CD Modulbox MERCEM MEAC Data acquisition Printer, PC, modem, Modbus Measuring gas sampling probe Mercury Hg SMG probe, for example EuroFID Hydrocarbons C n H m Electrical connections Optical connections Measurig gas System Technology SICK MAIHAK not only supplies but also designs complete gas analysis systems including everything from the measuring technology, officially recognized emissions monitoring to ready-to-use preinstalled, accessible analysis containers with all the necessary measuring devices. 8

Technology with a System Specifications and Technical Data Technical Data MCS 100 E System Measurement ranges MCS 100 E HW MCS 100 E PD MCS 100 E CD Meas. gas components Analyzer Measuring principle Cell Measurement ranges Limit values Detection range Zero drift Temp. influence Cross sensitivity comp. Barometric correction Sensitivity control Response time T 90 Display Keyboard Operation Computer; bulk memory System cabinet Dimensions (H x W x D) Cabinet Weight Power supply Power consumption Ambient conditions Degree of protection Maintenance interval HCl 0 15 mg/m 3 1) 0 10 mg/m 3 1) CO 0 75 mg/m 3 1) 0 50 mg/m 3 1) 0 50 mg/m 3 NO 0 200 mg/m 3 1) 0 50 mg/m 3 1) 0 50 mg/m 3 NH 3 0 20 mg/m 3 1) NO 2 0 100 mg/m 3 1) 0 80 mg/m 3 1) 0 80 mg/m 3 SO 2 0 75 mg/m 3 1) 0 10 mg/m 3 1) 0 10 mg/m 3 CO 2 0 25 vol.% 1) 0 25 vol.% 1) 0 25 vol.% O 2 0 21 vol.% 1) 0 21 vol.% 1) 0 21 vol.% H 2 O 0 40 vol.% 1) 0 5 vol.% 1) 0 5 vol.% N 2 O 0 100 mg/m 3 0 100 mg/m 3 0 100 mg/m 3 CH 4 0 100 mg/m 3 0 100 mg/m 3 0 100 mg/m 3 Continuous, max. 8 plus O 2 ; further IR-active components and other meas. ranges avail. on request MCS 100 E integrated in system cabinet Infrared photometer, bifrequency and gas filter correlation proced.; spectral range from 1 16 μm Optical path length: 3 m or 6 m (10 or 19.7 ft) preset; temp: 185 C (365 F), optional 225 C (437 F) Volume 2 l (0.5 gal); gas flow rate: 200 600 l/h (7 21 ft 3 ) (acc. to application), filter porosity: 10 µm 2 measurement ranges in each case with automatic switchover, freely programmable 2 limit values in each case as change-over contact, freely programmable <2% of the relevant measurement range end value (full scale) Automatic zero point correction <2% of the relevant measurement range/10 K Provision for 4 interference variables, external variables also possible Range from 0.7 to 1.2 hpa (0.3 0.5 inwc) atmospheric pressure Test gas, optional internal calibration filter Plant and component specific, typically <200 s (sec) Monochrome 7.4 LC monitor, 640 x 480 pixels, illuminated Numerical touch-sensitive keyboard with arrow/function keys; external keyboard can be connected 2 levels for user and specialist (password); programs freely programmable IBM-compatible 686 CPU based on PC104 bus; 32 MB silicone disc 2100 mm x 800 mm 600 mm (83 in x 31.5 in x 23.6 in); height incl. 100 mm (3.9 in) base Material: sheet steel, color: RAL 7032 (light gray) Approx. 350 500 kg (772 1,102 lb); depending on components 3-ph 230, +10/ 15%; 50 Hz; opt.: 3-ph 115 V, +10/ 15%; 60 Hz; special version avail. on request Cabinet: 1700 VA; heated gas line: 95 VA/m gas sampling filter: 450 VA; heated sampling probe: 150 VA Temperature: +5 35 C (41 95 F) humidity: up to 80% (without condensation) IP 43; higher degrees of protection available on request 3 months Standards EN 61010-1; EN 61326 Requirements/compliances 2) TA air act 3), 13 th /17 th Implementing Ordinances, EPA, GOST, MCert, ISO 7935, ISO 10 849, ISO 12 039 Interfaces and Signals Interfaces Signal outputs Signal inputs Serial: RS 232, RS 485, modem, Modbus protocol, others available on request; parallel: optional Digital: 50 V AC/4 A; 24 V DC/4 A; 50 V DC/0.8 A for maintenance and faults; others optional Analog : 0/4 to 20 ma, resolution 12 bit, accuracy 0.5%, load 500 Ω Optional: analog and digital 1) Performance tested 2) Do not supply for MCS 100 E CD 3) Federal German Pollution Control Act (13 th /17 th Implementing Ordinances), 9

A n a ly z e r s a n d P r o c e s s I n s t r u m e n tat i o n At h o m e i n t h e i n d u s t r i a l s e c t o r W e o f f e r yo u a c h o i c e A r o u n d t h e w o r l d t o yo u r s e r v i c e SICK Group We can build on years of experience in the field of Analyzers and Process Instrumentation. That is why we are at home in the world of cement and power plants as well as in the chemical and petrochemical sector. Be it emission control at the waste treatment or process optimization for steel manufacturing, SICK MAIHAK offers tailor-made solutions. SICK MAIHAK offers a number of sensor-based techniques for analysis, ranging from the continuous gas and dust measurement to specialized applications for water and liquid analysis. Within the process measurement technology SICK MAIHAK products play a central role in determining volume flow of gases and level of bulk materials. Where ever you are, our global network of subsidiaries and representatives is able to supply qualified support when you need it. We deliver the equipment for your measuring tasks, provide documentation and training. Our highly skilled service staff offers support during installation, commissioning and maintenance of the appliances. SICK MAIHAK represents the process automation segment of the SICK group, one of the worlds leading manufacturer of intelligent sensors and sensor solutions. With its 4,000 employees, SICK is able to offer an extensive portfolio of products and services on the market of factory automation. www.sick.com 80010576/2006-03 DIV03/BW Printed in Germany (2006-03) Subject to change without prior notice SICK MAIHAK GmbH Analyzers and Process Instrumentation Nimburger Str. 11 79276 Reute Germany www.sick-maihak.com Phone +49 7641 469-0 Fax +49 7641 469-1149 info.sick-maihak@sick.de Analyzers and Process Instrumentation