KIT FOR AIR PELLET STOVES

Similar documents
KRONOS GA11 WEEKLY-PROGRAMMING DIGITAL CHRONOTHERMOSTAT FOR THE REMOTE CONTROL OF HOT AIR GENERATORS THROUGH BRAHMA INTERFACE BOARD APPLICATION

Drayton Digistat +2RF/+3RF

24 Wide Screen LED Monitor with HDMI

B/S/H/ Error codes and service programmes PH

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

PD 100A. Printing data system

EBDSPIR-PRM, EBDSPIR-PRM-IP

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Electronic Control Devices The European Product Catalogue 2007

NL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module

HERZ-Thermal Actuators

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

Duct Humidity Transmitter

GSM HOME SECURITY SYSTEM

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Fossil fuel heating equipment

User Manual for CH-PFC76810

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

RF 1. Contents: Connecting diagram. Detailed information:

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Time Recorder. User Manual. PDF created with FinePrint pdffactory trial version

Porcia, 20 novembre 2012

STERILIZERS, LABORATORY DRYING OVENS

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

GSM Alarm System User Manual

How To Use A Power Supply On A Powerline 2.2 (Ai)

Luna 3 Comfort Troubleshooting Guide June 2008

Telefon (+45) Telefax (+45) Installation and operating manual

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Operating instructions for built-in electronic timers with Day and Week programms. Series 884

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

LUCCI AIRFUSION QUEST II CEILING FAN

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

ELECTRIC CENTRAL HEATING FLOW BOILER

User and installation manual

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

Workshop 7 PC Software - Tracker

HEAT HEAT COOL HEAT PUMP COOL

T-100-R Installation Guide

MAGICAR M871A. Car alarm with two-way remote User s guide

Quick start: Energy Switch EU

Table of Contents. 1 - Specifications Installation Wiring User controls...7

Inwall Room Temperature Unit

OZW30. Central Unit SYNERGYR

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

Wireless Thermostats 230v and Battery Operated Instruction Manual

Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.

MP-4000 Alarm List (Software version or later)

IH E Sigma Island 90

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331)

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

RAINCONTROL LCD Special

Electronic Control Devices The European Product Catalogue 2007

EBDSPIR-DD, EBDSPIR-DD-IP

REMOTE CONTROL MANUAL

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Nokeval. User's Manual Models 301 / 302 / 305

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Controls for fan coil units and cassettes

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

OPL BASIC. Dosing System for Professional Laundry machines. Contents

User s Manual Before using the inverter, you need to read and save the safety instructions.

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify



T0118 T2118 T3118. Instruction Manual

Regolatori per Refrigerazione Digitali FR canali

AVR Pellet Control Board Installation/Service Instructions

1 QPro HelpFile 01.EN COPYRIGHT CONTRIVE

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

EK908FHL - Thermostat for floor heating

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

G-100/200 Operation & Installation

Stove Guard Kit User Manual

Installation and User Guide

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

ABB i-bus KNX Fan Coil Controller FC/S 1.1

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

USER S MANUAL HSC-24A

TC-9102 Series Surface Mount Temperature Controllers

Drayton Digistat +2RF

FIREDEX Conventional Fire Panels

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

PART 11: START-UP PROCEDURES FOR THE INSTALLER

INSTRUCTION MANUAL OVERVIEW Remote Meter: MT-5 Remote meter (Model MT-5) is available to connect with solar controller Tracer MPPT series.

Transcription:

KIT FOR AIR PELLET STOVES DIGITAL CONTROL SYSTEM FOR DOMESTIC WOOD PELLET STOVES WITH AIR/AIR EXCHANGER Pellet Kronos AMBIENT UNIT WITH USER AND INSTALLER INTERFACE AND CHRONOTHERMOSTAT FUNCTION Pellet Board POWER UNIT FOR ON-BOARD STOVE LOAD CONTROL DESCRIPTION The Brahma "KIT FOR AIR PELLET STOVES" enables to automatically control a domestic wood pellet stove with air/air exchanger and to optimize room temperature adjustment and fuel consumption. The kit consists of two main units: the first one is dedicated to the user interface and room temperature adjustment with chronothermostat functions, while the second one performs on-board stove load power control. Data communication between the two units occurs by means of a two-wire cable; in particular, it is possible to install the user interface on the wall, in a suitable position for room temperature detection, in order to optimize domestic comfort and access or adjust operation parameters without having to approach the burning stove. The main units can be fitted with a simple and user-friendly IR remote control unit allowing to easily interact with the user interface and enable its main functions. Remote Control Unit AMBIENT UNIT REMOTE CONTROL (OPTIONAL) GENERAL CHARACTERISTICS Pellet Kronos exclusive Brahma design graphic LCD, 28x64 dots, backlit diagnostics/signalling LED 6 variable function keys remote control unit IR receiver to be mounted on the stove in a handy position or to be installed on the wall SELV (Safety Extra Low Voltage) insulation simple (non-polarized) connection to the power unit by means of a two-wire cable, having both the function of power supply and data communication support. Pellet Board domestic single-phase network power supply (230Vac) to be mounted inside the stove in a position not to be reached by the user support of ambient unit communication and power supply for the stove remote control (by means of a two-wire cable with a length up to 50m) integrated diagnostics/signalling LED control of all stove loads combustion power (air/pellet ratio) modulation air pressure switch and safety thermostat inputs. Remote Control Unit infrared, unidirectional 5 function keys lithium button cell type CR-2032 no consumption in stand-by TECHNICAL DATA Operating temperature: 0 C +60 C Humidity: 95% max. at 40 C 7454_r0 /0

Pellet Kronos Power supply: low voltage, obtained through the communication with the power unit Protection rating: IP30 Weight: 0,70 Kg Dimensions: 40x90x32 mm Pellet Board Power supply: 230Vac-50/60Hz Protection rating: IP00 Weight: 0,276 Kg Relay outputs: max. A 250Vac cosϕ=0.4 Triac outputs: max. A 250Vac Thermal fuse protection: 3,5A/250V (loads included) Dimensions: 60x00x45 mm Remote Control Unit Power supply: CR-2032 lithium cell Protection rating: IP30 Weight: 0,044 Kg Dimensions: 00x43x2 mm ACCESSORIES The system can be supplied complete with: Brahma NTC contact temperature probe type ST07, to be connected to the power unit for room temperature detection on the stove. DIRECTIONS FOR INSTALLATION Respect the applicable national and European standards (e.g. EN60335-/prEN5065) regarding electrical safety. Before starting the system check the cables carefully; a wrong wiring can damage the devices and compromise the safety of the installation. Connect and disconnect the control system only after switching off the power supply. Avoid exposing the system to dripping water. WIRING THE POWER UNIT All wirings on the electronic board (i.e. power unit) should be arranged by means of pull-out screw terminal boards. In Fig. you can find all the connections available on the board, including optional ones, as well as a table showing all connector pins in detail. AMBIENT UNIT J J J0 J2 J3 J9 - GND +5V HALL + AUX LED TC2 N J8 ROOM P. PELLET P. FUSE - + THERM. J6 J5 J7 J4 TC POWER SUPPLY L IGN. N N EXHAUST GAS EXCHANGER SCREW FEEDER POWER-FREE CONTACT A.P.S. S.T. A.P.S.=Air Pressure Switch S.T.=Safety Thermostat P. =Probe Pin Type Function J6,2 line 230 Board and loads power supply J gnd Ground connections J5 out Spark plug 3,4 230 J5 out Screw feeder,6 230 J6 3,4 out 230 Exhaust gas extraction fan J6 out Exchanger fan 5,6 230 J5 (I) Air pressure switch 2,5 J5 5,6 (I) Pellet fire safety thermostat connection J4,2 I Exhaust gas thermocouple J4 I Room temperature probe 5,6 J2 2,3,4 I Exhaust gas extraction fan impulses J9 I/O Ambient unit communication J I/O Microcontroller programming J0 I/O UART J3 I Auxiliary thermocouple J4 9,0 I Auxiliary temperature probe J4 3,4 I Auxiliary input (ref. additional thermostat) J8 out Triac aux. output 230 J7 out Power-free contact aux. output FIGURE : illustration and description of the power unit electrical wiring terminals 2/0 7454_r0

WALL-MOUNTING THE AMBIENT UNIT In order to mount the base on a wall, first of all open the front cover containing the user interface electronic board, by softly pressing the trapezoidal push-button with the word "PUSH" placed on the bottom side of the unit, and then rotate the front cover upwards until it is completely removed as shown in Fig.2. USER INTERFACE AND DIRECTIONS FOR USE The user interface, consisting of the PELLET KRONOS and its remote control unit, is equipped with simple and user-friendly commands. Fig.3 shows the various parts of the user interface and the layout of the push-buttons available to the user. 2 AMBIENT UNIT The ambient unit, in particular, enables the user and the installer to easily carry out several operations through few function keys thanks to the support of a graphic display. Next to each push-button, in fact, there is a display area indicating the type of command currently associated to the push-button according to the operation status and to the menu displayed in that moment. As shown in Fig.4, for example, when the system is off (OFF, reduced display brightness), the only enabled bushbutton is the one on the bottom left side, which turns the system on if it is pressed for at least 3 seconds. Figure 2: directions for opening the front cover ) press push-button "PUSH" 2) rotate upwards To fix the base you can use the various eyelets available on its back, which are suitable for the most common centre-to-centre distances used in domestic installations; to this subject see Fig.6. After fixing the base, you can wire the ambient unit electronic board through the pull-out terminal board and without having to pay attention to polarity (the two conductors can be reversed). We recommend using a two-wire cable (for example H03RR-F or H03VV-F) with a section between 0,5 mm 2 and 2,5 mm 2, paying attention not to exceed a length of 50m and bearing in mind that in any case the resistance of each conductor should not exceed 5Ω. In the rooms with particularly strong electromagnetic interference we recommend using a shielded two-wire cable. Once the wiring has been accomplished, mount the front cover on the base by fixing it to the top hooks and then rotate it downwards until it clicks into the bottom hooks. Figure 4: display in "OFF" status When the control system is on (ON), the display typically looks like shown in Fig.5. In this case, all push-buttons are enabled and you can easily understand that the left side push-buttons adjust the stove power level, which can vary from to 5 and is displayed by means of a number and a level bar, whereas the right side push-buttons adjust the room temperature; the set temperature appears blinking when you press these push-buttons, while the display normally shows the currently detected room temperature. graphic display (LCD) hole to reach the reset pushbutton 2 remote control unit IR receiver 6 5 automatic mode (timer) or manual mode flame level variation room temperature setting 3 4 function keys (the currently enabled command appears each time on the graphic display) Figure 3: description of the ambient unit and the remote control unit keys 7454_r0 3/0

On the top left side you can find an icon regarding the communication between the PELLET KRONOS and the PELLET BOARD units. Additional elements can be displayed: if the internal clock has been adjusted, the day of the week and the current time are also shown, as you can see in Fig.6. Just below, in the centre, a short text describes the temperature adjustment and the flame status; the same information is also shown by a well visible icon in the centre of the display which can easily be seen even a few steps away from the stove. Table shows all the available operation statuses which can be displayed. Finally, the framed text on the right side indicates whether the automatic or the manual operation modes are selected. Figure 5: display in "ON" status Display PRE-VENT IGNITION LOAD PELLET FLAME ON ECON. SERVICE TEMP. OK NO TIMER COOLING STATUS description Pre-purge (pre-ventilation) Ignition Pellet loading Flame detected Economy operation (min. power) Call for service Room temperature reached The weekly program plans no ignition at the current time Switching off (cooling) Table : operation statuses appearing on the display In normal operation, the bottom left side push-button keeps its own function [ON-OFF], while the bottom right side push-button [SHIFT] has the function of shifting the commands associated to the other push-buttons: if you keep it pressed, in fact, the symbols on both sides of the display change, as you can see in Fig.6, whereas while pressing [SHIFT] and one of the other push-buttons simultaneously, various functions can be enabled. 4/0 Figure 6: display with SHIFT push-button pressed: highlighted are the icons corresponding to various push-button functions USING THE [SHIFT] PUSH-BUTTON [SHIFT] + [INFO] It displays information about the activation of the stove loads and their power modulation, as shown in Fig.7. This function is particularly useful to the service technician, but can also enable the end user, if required, to have anytime a quick overview of the stove operation. Among the numeric values shown by the display, you can find the ambient heat exchanger fan speed (Heat exch., in percentage) and the exhaust gas extractor speed (Extr. speed, in revolutions per minute), the screw feeder motor start-up time (Screw feed) referred to a period of 4 seconds, the combustion fumes temperature (Fumes temp) and the room temperature (Room temp). Another important data is the numeric value (Curr. Stage) indicating the current operation stage of the system: this parameter enables to understand which stage of the operating cycle is currently being performed by the stove, and is useful to "align" the communication between the ambient unit and the power unit. Table 2 shows the meaning of the values that this parameter can take. No. 0 2 3 4 5 6 7 8 9 0 STAGE description Off Pause Chamber cleaning pre-purge Pellet loading / ignition (no flame) Pellet ignition / flame settlement (flame on) Working stage ECON mode Temperature OK Brazier cleaning Cooling Failure lockout Installer mode Table 2: operation stages 7454_r0

Hereunder you can find a detailed description of each system setting menu. OPTIONS It contains several general options and parameters freely accessible to the user, regarding the interface (in particular the display) and the stove temperature adjustment. Fig.9 shows the page appearing on the display when entering the OPTIONS menu. Figure 7: technical data displaying page [SHIFT] + [A/M] It shifts the operation mode from manual to automatic and vice versa. In automatic mode, the ambient controller operates like a weekly chronothermostat with one settable temperature value: the stove switches on in the periods planned by the weekly program (timer) only, provided that the time has been adjusted and the room temperature is lower than the preset value. In manual mode, the ambient controller has a thermostatic function only, and the stove switches on in order to keep the room temperature as close as possible to the preset value. In any case, the thermostatic function is implemented in such a way that if Ta is the detected room temperature, Ti is the set temperature and d is the differential: if Ta < Ti, the stove is switched on at the power selected by the user; if Ti =< Ta < Ti+d, the stove is switched on at min. power; if Ta >= Ti+d, the stove is switched off. The following paragraphs describe how to set the timer (see SET TIMER menu) and how to select the temperature differential of the room thermostat function. [SHIFT] + [MENU] This command enters the main page of the system setting menus. The display appearing to the user is shown in Fig.8, where you can see four different menus, each of which can be entered by selecting the corresponding line and pressing [OK]. Hereunder you can find the meaning of each menu item in detail: VENTIL. This is related to the exchanger fan and allows to select either a constant ventilation (NORMAL, default), depending on the power level only, or a modulating ventilation (AUTO), depending on the exchanger temperature (when the exchanger cools down, ventilation is reduced to avoid cold air circulation in the room). PROBE This parameter indicates which probe is used to detect room temperature: it is possible to choose either the probe mounted on the stove (EXTERNAL, default) or the one placed inside the ambient unit (INTERNAL). SOFT COOL. This option allows to choose a low-noise cooling mode (YES, default) instead of the commonly used one (NO) which would let the exchanger fan rotate at its highest speed. Figure 9: OPTIONS menu DIFF. TEMP. In order to optimize room temperature adjustment, it is possible to set the d differential (see paragraph regarding [SHIFT] + [A/M]) from degree min. (default) to 3 degrees max. Figure 8: user interface main menu This splitting into different setting menus has the purpose of simplifying the user's access to the most important and mainly used functions available in the first three freeaccess menus, but it also has the function of protecting the parameters reserved to the installer/service technician which are available in the SET SYSTEM menu and are only accessible through a password. 7454_r0 TYPE PELLET In order to optimize combustion by adapting the stove operation to different types of pellet, it is possible to set this parameter, variable from to 5 and corresponding to different air/pellet ratio calibrations. The default value for the type of pellet is 3. LIGHT MIN When the system is on, if no key is pressed for 60 seconds the display brightness is reduced to LIGHT MIN value, which can vary from to 0 but can never exceed the LIGHT MAX preset value (max. brightness parameter). The min. brightness default value is 2. 5/0

LIGHT MAX When pressing any key on the board or the remote control unit, the display brightness increases to the level specified by the LIGHT MAX parameter for 60 seconds. This value can vary from to 0 but cannot be lower than LIGHT MIN. The LIGHT MAX default value is 6. CONTRAST This is useful to improve the display visibility in case it should be difficult to read. This parameter, variable from -9 to +9 and with a default value equal to 0, does not usually require any change. CHANGE PASSWORD This option allows to change the password reserved to the technical service staff. The system requests a new password, which should be repeated in order to be confirmed. When pressing OK the new access code is enabled. FACTORY RESET This enables to reset Pellet Kronos restoring factory-set parameters. INFO This shows technical information about the revision number of the kit parts. TIME SERV. This displays the stove operation hour counting (with burning brazier). Figure : weekly timer programming The days of the week are listed in seven lines starting from Monday on the top (M = Monday) to Sunday on the bottom (S = Sunday), whereas hour intervals from 0 to 23 are shown one after the other in 24 columns. After moving to the required position through the pushbuttons by moving the cursor vertically and horizontally, you just have to press the [SET] push-button to enable (or disable) the stove switching on in the period corresponding to the position of the cursor. The stove automatic switching on is subordinated to the adjustment of the current time (SET TIME) and to the actual heating demand, i.e. the room temperature should be lower that the preset value. Fig.2 shows how the display looks like when a particular hour program is enabled. SET TIME This function allows to adjust the current time and the day of the week: you just have to select the value to modify using the left push-buttons and then adjust it through the right push-buttons. Fig.0 shows the only page of this sub-menu. Figure 2: display in automatic operation mode SET SYSTEM To access system settings, it is necessary to enter a 4figure password. It is possible to enter two valid passwords, both having the same degree of access to settings. The first password cannot be changed and is exclusively known and used by the stove manufacturer. The second password is reserved to the technical service staff and can be modified through the CHANGE PASSWORD option. Figure 0: current time setting SET TIMER In automatic operation, the stove can switch on depending on the room temperature, but also according to a hour resolution weekly program called "timer". Through this sub-menu, the user can program the weekly timer according to his own needs in a very simple and userfriendly way thanks to the graphic display of the whole week, as shown in Fig.. Figure 3: password request for access to "Set system" menu 6/0 7454_r0

Authorized access to settings allows to display the menu shown in Fig.4. Figure 4: access to system settings MANUAL SERVICE This service function can be used in order to help any testing and maintenance operations: through a userfriendly interface it is possible to enable each electrical load of the stove independently. TYPE SYSTEM By pressing [OK] under this menu item it is possible to choose among 5 parameter sets. Each parameter set is provided with factory-set values, i.e. values specified by the stove manufacturer. It is therefore possible to associate each parameter set to a particular stove model. OPERATION PARAMETERS The operation parameter set loaded by PELLET KRONOS at start-up is accessible through the interface illustrated in Fig.4. The meaning and valid fields for each parameter are summarized in tables 4, 5, 6 in Appendix. FORCING OPERATION STAGES FOR COMBUSTION TESTING In order to easily carry out any combustion testing, it is possible to force some operation stages without respecting their exact sequence or the waiting time requested by the automatic control. To use this function, you should first of all put the stove in heating demand condition, i.e.: set manual operation mode; increase the set temperature in order for this to be higher than the current room temperature; set a flame power level higher than zero. Afterwards, enter the information menu ([SHIFT] + [INFO]) and use the key combinations listed in table 3, keeping them simultaneously pressed for at least 3 seconds (long pressing), and referring to Table 3 for the keys to use, and to Table 2 for the numbering of the operation stages. ERRORS AND FAILURES If the system detects any anomaly in the stove operation, it starts the switching off stage and displays an error code. Table 4 shows the available error codes with the description of the corresponding failure. Errors can be cancelled by keeping the central push-button pressed for more than 3 seconds. Failure cancelling leads to the error code signalling disappearing on the display and the red LED switching off. No. ERR0 ERR02 ERR03 ERR04 ERR05 ERR06 ERR07 ERR08 ERR09 ERR0 Failure description Air pressure switch intervention (ignition / working stage) General thermostat intervention (limit safety thermostat overtemperature) Ignition failure Switching off in working stage Switching off due to power outage Exhaust gas temperature probe failure Room temperature probe failure Exhaust gas overtemperature Communication failure Software version incompatibility failure (control board / power board) Table 4: error codes and failure description REMOTE CONTROL UNIT The remote control unit, which should be used by pointing it at the ambient unit (since the IR receiver is placed in the ambient unit and not in the stove), enables the user to remote control the simplest settings: ON/OFF (by simultaneously using the "-" keys); automatic or manual, to enable or disable the operation programmed through the timer; flame power variation; required room temperature setting. Fig.3 shows the remote control unit keys and their functions. Keys Stage Description 4 & 9 Forced cooling 4 & 5 5 Working stage 4 & 6 2 Hot re-ignition Table 3: key combinations for stage forcing Stage forcing is only allowed if the stove is not in "lockout" condition in consequence of a failure. Note: In the end-user instruction manual it is advisable not to indicate the special key combinations required for stage forcing: any incautious use of this function may lead to possible operation anomalies. 7454_r0 7/0

APPENDIX : OPERATION PARAMETERS Pr Description Value field N0 N N2 N3 N4 N5 Pr0 Max. time for an ignition cycle from to 8 5 5 5 5 5 5 Pr02 Flame settlement time in FIRE ON stage from to 5 5 5 4 4 4 4 Pr03 Time interval between two brazier cleanings from 20 to 90 60 60 45 45 45 45 Pr04 Continuous loading time in LOAD WOOD stage from 0 to 240 0 0 45 45 45 45 Pr05 Screw feeder motor ON time in FIRE ON stage from 0,2 to 2,0 0,9 0,9 0,9 0,9 Pr06 Screw feeder motor ON time in working stage at power from 0,2 to 2,0 0,9,2 0,6 0,9 0,7 Pr07 Screw feeder motor ON time in working stage at power 2 from 0,3 to 3,0,6,6 0,9,2,,3 Pr08 Screw feeder motor ON time in working stage at power 3 from 0,4 to 3,5 2,3 2,3,5,5,6 Pr09 Screw feeder motor ON time in working stage at power 4 from 0,5 to 3,5 3 2,6,6,7,9,9 Pr0 Screw feeder motor ON time in working stage at power 5 from 0,5 to 4,0 3,8 3,2 2,2,9 2,3 2,3 Pr Available for future use - - - - - - - Pr2 Brazier cleaning time from 0 to 240 20 20 40 40 40 40 Pr3 Exhaust gas min. temperature required for stove on from 40 C to 0 C 50 50 50 50 50 50 Pr4 Exhaust gas temperature alarm threshold from 0 C to 250 C 230 230 230 230 230 230 Pr5 Exhaust gas temperature threshold for exchanger switching on from 40 C to 0 C 80 80 70 60 60 60 Pr6 Exhaust gas extraction speed during start-up in LOAD WOOD stage from 600 to 2500 580 580 900 800 800 800 Pr7 Exhaust gas extraction speed during start-up in FIRE ON stage from 600 to 2500 480 480 2250 800 800 800 Pr8 Exhaust gas extraction speed in working stage at power from 600 to 2500 700 300 700 300 800 300 Pr9 Exhaust gas extraction speed in working stage at power 2 from 600 to 2500 00 430 350 550 00 650 Pr20 Exhaust gas extraction speed in working stage at power 3 from 600 to 2500 400 590 750 700 400 850 Pr2 Exhaust gas extraction speed in working stage at power 4 from 600 to 2500 700 640 850 900 700 2050 Pr22 Exhaust gas extraction speed in working stage at power 5 from 600 to 2500 2000 750 2020 200 2050 2300 Pr23 Exchanger motor speed in working stage at power from 70% to 76% 70% 70% 76% 74% 74% 70% Pr24 Exchanger motor speed in working stage at power 2 from 77% to 82% 80% 82% 82% 82% 82% 80% Pr25 Exchanger motor speed in working stage at power 3 from 83% to 88% 88% 88% 88% 88% 88% 88% Pr26 Exchanger motor speed in working stage at power 4 from 89% to 94% 94% 94% 94% 94% 94% 93% Pr27 Exchanger motor speed in working stage at power 5 from 95% to 00% 00% 00% 00% 00% 00% 00% Pr28 Temperature gradient for flame detection (degrees/minute) from 0 C to 5 C 3 3 3 3 3 3 Table 5: ignition and operation parameters for 6 stove models, from N0 to N5 (example values) Pr Description Value field N0 N N2 N3 N4 N5 Pr45 Operation period after which "serv" message is displayed from 00 to 9900 hours - - - - - - Pr46 Complete lockout alarm delay after "serv" message from 0 to 000 hours - - - - - - Pr47 Mechanical cleaning interval from ' to 255 - - - - - - Pr48 Mechanical cleaning activation time from ' to 255 - - - - - - Pr49 Mechanical cleaning activation time in switching off stage from to 255 - - - - - - Pr50 Power change delay from 30" to 240" 60 60 60 60 60 60 Table 6: service intervention signal parameters (example values) 8/0 7454_r0

APPENDIX : OPERATION PARAMETERS Pr Description Value field N0 N N2 N3 N4 N5 Pr56 Pellet load variation (pellet type ) 0, sec. per step from -5 to 5-4 -4-4 -4-3 -4 Pr57 Exhaust gas extraction speed variation (pellet type ) 3% per step from -5 to 5 5 5 5 5 3 5 Pr58 Pellet load variation (pellet type 2) 0, sec. per step from -5 to 5-2 -2-2 -2-2 -2 Pr59 Exhaust gas extraction speed variation (pellet type 2) 3% per step from -5 to 5 3 3 3 3 2 3 Pr60 Pellet load variation (pellet type 3) 0, sec. per step from -5 to 5 0 0 0 0-0 Pr6 Exhaust gas extraction speed variation (pellet type 3) 3% per step from -5 to 5 0 0 0 0 0 Pr62 Pellet load variation (pellet type 4) 0, sec. per step from -5 to 5 0 0 0 0 0 0 Pr63 Exhaust gas extraction speed variation (pellet type 4) 3% per step from -5 to 5-2 -2-2 -2 0-2 Pr64 Pellet load variation (pellet type 5) 0, sec. per step from -5 to 5 0 0 0 0 0 Pr65 Exhaust gas extraction speed variation (pellet type 5) 3% per step from -5 to 5-4 -4-4 -4 0-4 APPENDIX 2: DIMENSIONS AND FIXING Table 7: pellet type adjustment parameters (example values) 7454_r0 9/0

90,0 00,0,2 40,0 30,8 43,0 20,5 Figure 5 : dimensions in millimetres of the power unit and the remote control unit 9,00 0,40 9,50 9,50 5,00 2,20 5,00 ø 3,80 8,25 7,5 Figure 6: fixing holes for the ambient unit ATTENTION! --> Company Brahma S.p.A. takes no responsibility for any damage resulting from Customer tampering with the device. BRAHMA S.p.A. Via del Pontiere, 3 37045 Legnago (VR) - ITALY Tel. +39 0442 6352 - Fax +39 0442 25683 http://www.brahma.it E-mail: brahma@brahma.it 20/03/6 Subject to amendments without notice 0/0 7454_r0