REPORT HOLDER: CLARKDIETRICH BUILDING SYSTEMS 9100 CENTRE POINTE DRIVE, SUITE 210 WEST CHESTER, OHIO EVALUATION SUBJECT:

Similar documents
DIVISION: SPECIALTIES SECTION: PROTECTIVE COVERS REPORT HOLDER: METALS BUILDING PRODUCTS/LATIUM USA TRADING, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER:

Trusted SECTION: 04 HILTI, INC. TULSA, Conformity! ICC-ES Evaluation. not specifically. Copyright 2015

(800) (562) A Subsidiary of the International Code Council *Revised April 2014

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in one year.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER: BORAL ROOFING

Discipline: Structural Issued

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

REPORT HOLDER: JENWEST ENTERPRISES LLC, DBA ADVANCED CONNECTOR SYSTEMS 321 SOUTH 1240 WEST #15 LINDON, UTAH EVALUATION SUBJECT:

CPA Steel Stud Framing Page 1 of 11

ICC-ES Evaluation Report

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: PLUMBING SECTION: DOMESTIC WATER PIPING REPORT HOLDER: CURAFLO IP LLC 4035 E. OASIS STREET MESA, AZ 85215

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

ICC-ES Evaluation Report Reissued September, 2010 This report is subject to re-examination in one year.

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

ESR-1190 Reissued December 1, 2009 This report is subject to re-examination in two years.

Standard from CSI Part Section Format For Wood Framing For Metal Framing For Gypsum Sheathing

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Corrected March 2014

TECHNICAL NOTE. Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006 IBC. On Cold-Formed Steel Construction INTRODUCTION

THE DOW CHEMICAL COMPANY Issued: August 1, LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN (989)

ICC-ES Evaluation Report. ESR-3493 Reissued September 2014 This report is subject to renewal September 2015.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Hilti, Inc South 122 nd East Avenue Tulsa, OK

Screw Penetration Testing with the ProSTUD

Chapter 6 ROOF-CEILING SYSTEMS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

SECTION COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

Residential Deck Safety, Construction, and Repair

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP APPLIED WOOD COATINGS SECTION: SHEATHING REPORT HOLDER:

CITY OF LOS ANGELES CALIFORNIA

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council RETAINED ON U.S.

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

COMMONLY USED RESIDENTIAL BUILDING CODES

ANCHOR: Metal securing device embedded or driven into masonry, concrete, steel or wood.

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: HUBBELL POWER SYSTEMS, INC.

POST AND FRAME STRUCTURES (Pole Barns)

research report Residential Hip Roof Framing Using Cold-Formed Steel Members RESEARCH REPORT RP06-2 American Iron and Steel Institute

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

Breakaway Walls

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

PART 1 GENERAL 1.1 SECTION INCLUDES

TEST REPORT. Report No.: A Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept

DENVER MODEL 30 X 30 SPECIFICATIONS

STRUCTURAL TESTS AND SPECIAL INSPECTIONS

Connection Solutions

GUARDRAIL POST STEEL

Repair of Earthquake-Damaged Masonry Fireplace Chimneys SOUTH NAPA EARTHQUAKE RECOVERY ADVISORY

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. CONTROL, NOT COMPROMISE.

Chapter 3 Pre-Installation, Foundations and Piers

Nucor VR16 II TM Vertical Rib Standing Seam Roof System

DIVISION: PLUMBING SECTION: INSTRUMENTATION AND CONTROL FOR PLUMBING REPORT HOLDER: XIAMEN SPRINT SHOWERS TECHNOLOGY CO. LTD.

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST

Scottsdale, Arizona. Presentation by: Hermes Norero, P.E. President and CEO

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER

Uncovered Decks & Porches

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

Detailing of Reinforcment in Concrete Structures

Page & Turnbull imagining change in historic environments through design, research, and technology

ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC

Fiberglas, Exterior Wall Thermal Insulation

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

SLAB DESIGN. Introduction ACI318 Code provides two design procedures for slab systems:

GUIDELINE SPECIFICATIONS

2009 IECC Update. Scope. Content. International Energy Conservation Code

The Florida Building Code

Hilti KWIK HUS-EZ I (KH-EZ I) Internally Threaded Carbon Steel Screw Anchor

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Featuring TJ Rim Board and TimberStrand LSL

Code Compliant Repair and Protection Guide

COLORADO MODEL. 35 x 65 SPECIFICATIONS

TZ WEDGE ANCHOR FOR CRACKED AND UNCRACKED CONCRETE

Submittal Information

Residential Decks. Planning and Development Services Department

RB271 06/07 R807.1 RB272 06/07 R Public Hearing: Committee: AS AM D Assembly: ASF AMF DF. Proponent: Rick Davidson, City of Hopkins, MN

Stucco and Windows on Wood Frame Construction. Maintaining the Water-shedding Barrier

Code of Standard Practice for Timber Frame Structures

Informational Bulletin

6 RETROFITTING POST & PIER HOUSES

VALOR STEEL BUILDINGS STANDARD SPECIFICATIONS

Design of Cold-Formed Steel Shear Walls

Construction Methods, Details, and Tips for Plumbers and Electricians. Steel Trade Contractor Guide. s t e e l f r a m i n g.

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

CF-Mesa, CF-Light Mesa, CF-Flute, CF-Metl-Plank, CF-Striated, CF-Santa Fe, CF-Architectural Flat, CF...

James M. Pleasants Company

March 14, Installation of Bay, Bow and Garden Windows

General Approach. Structure Components. Is all lumber the same? Lumber Grades. Rafters Girders / Beams Columns. Sketch general structural layout

Residential Prototype III. Multi-Story. The Multi-Story. Your connection to ideas + answers. Prepared by: AISC Steel Solutions Center

THERMAL DESIGN AND CODE COMPLIANCE FOR COLD-FORMED STEEL WALLS. Steel Framing Alliance th Street, NW, Suite 320 Washington, DC 20005

ARROWHEAD GENERAL INSURANCE AGENCY RESIDENTIAL EARTHQUAKE INSURANCE PROGRAM UNDERWRITING GUIDELINES & RATE MANUAL

H-Stud Area Separation Wall System

Design and Construction of Cantilevered Reinforced Concrete Structures

For the purposes of this Part, the following words shall have the following meanings:

RESIDENTIAL MASONRY A BEST PRACTICES GUIDE

Transcription:

0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-1166 Reissued 08/2016 This report is subject to renewal 08/2017. DIVISION: 05 00 00 METALS SECTION: 05 40 00 COLD-FORMED METAL FRAMING SECTION: 05 41 00 STRUCTURAL METAL STUD FRAMING SECTION: 05 42 00 COLD-FORMED METAL JOIST FRAMING SECTION: 09 22 16.13 NON-STRUCTURAL METAL STUD FRAMING CLARKDIETRICH C-SECTIONS AND TRACKS Look for the trusted marks of Conformity! 2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as Copyright 2016 ICC Evaluation Service, LLC. All rights reserved.

ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-1166P Reissued August 2016 This report is subject to renewal August 2017. A Subsidiary of the International Code Council DIVISION: 05 00 00 METALS Section: 05 40 00 Cold-Formed Metal Framing Section: 05 41 00 Structural Metal Stud Framing Section: 05 42 00 Cold-Formed Metal Joist Framing Section: 09 22 16.13 Non-Structural Metal Stud Framing (513) 870-1100 www.clarkdietrich.com info@clarkdietrich.com michael.kerner@clarkdietrich.com CLARKDIETRICH C-SECTIONS AND TRACKS 1.0 EVALUATION SCOPE Compliance with the following codes: 2012 and 2009 International Building Code (IBC) 2012 and 2009 International Residential Code (IRC) Property evaluated: Structural 2.0 USES The C-sections and tracks are used for joists, rafters, nonload-bearing interior walls, curtain walls, and loadbearing walls. 3.0 DESCRIPTION 3.1 General: The C-sections and tracks recognized in this report are factory-formed from coils of steel at the ClarkDietrich Metal Framing facilities noted in Table 2. The C-sections are manufactured with and without web punch-outs. When provided, the punch-outs have a width of 1 1 / 2 inches (38 mm) and a length of 4 inches (102 mm) in members with a depth of 3 1 / 2 inches (89 mm) or greater. In C-sections with a depth of 2 1 / 2 inches (64 mm), punch-outs have a width of 3 / 4 inch (19 mm) and a length of 4 inches (102 mm). The punchouts are spaced a minimum of 24 inches (610 mm) on center and have a minimum distance between the end of the member and the near edge of the punch-out of 10 inches (254 mm). The C-sections and tracks are detailed in the ClarkDietrich Building Systems catalog entitled Cold- Formed Structural Framing Products Technical Design Guide, copyrighted November 2012, which is distributed with this report. The following tables from the catalog are part of this report: Product Information How to identify our products... page 3 Wall Stud & Floor Joist Section Stud/Track Properties... pages 5, 7-16 Note: GREEN Benefits and Recycled Content (page 5) is outside the scope of this report. Allowable Stud & Track Shear Values... pages 17 Interior Light-Gauge Limiting Wall Heights...pages 18-25 Exterior Light-Gauge Limiting Wall Heights... pages 26-38 Note: Exterior walls must be designed for a transverse load of no less than 10 psf (478 Pa). Combined Axial and Lateral Load Tables for Exterior Wall Studs... pages 39-54 Note: Exterior walls must be designed for a transverse load of no less than 10 psf (478 Pa). Allowable Unbraced Axial Loads... pages 55-59 Floor Joist Span Tables... pages 66-91 Note: Figures on page 67 are outside the scope of this report. Allowable Web Crippling Loads...pages 92-95 All other pages in the Cold-Formed Structural Framing Products Technical Design Guide catalog are outside the scope of this report. The inside bend radius of all members is based on thickness and is as follows: MILS DESIGN (in) THICKNESS 33 0.0346 0.076 43 0.0451 0.071 54 0.0566 0.085 68 0.0713 0.107 97 0.1017 0.152 INSIDE BEND RADIUS (in) ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as Copyright 2016 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 3 1000

ESR-1166P Most Widely Accepted and Trusted Page 2 of 3 3.2 Materials: The ClarkDietrich metal framing members recognized in this report are cold-formed from galvanized steel coils conforming to ASTM A1003-13 Structural Grade 50 Type H (ST50H), ASTM A1003-13 Structural Grade 33 Type H (ST33H), ASTM A653 SS Grade 50 Class I or ASTM A653 SS Grade 33. The steel conforming to ST50H and ST33H has a minimum metallic coating of G60 (ASTM A653), A60 (ASTM A653), AZ50 (ASTM A792), GF30 (ASTM A875), T1-25 (ASTM A463), T2-100 (ASTM A463), or 30Z/30Z (ASTM A879-12). Steel conforming to ASTM A653 SS Grade 50 Class 1 has a minimum metallic coating designation of G60 or A60. The steel conforming to ASTM A653 SS Grade 33 may have either a minimum metallic coating designation of G60 or A60 or a minimum metallic coating designation of G40. Framing members with a minimum metallic coating designation of G40 are limited to use in interior nonload-bearing walls subject to a maximum 10 psf (478 Pa) transverse load. 4.0 DESIGN AND INSTALLATION 4.1 Design: The section properties for the cold-formed steel framing members recognized in this report have been determined in accordance with the applicable edition of the North American Specification for Design of Cold-Formed Steel Structural Members (AISI). The allowable moments, as indicated in this report, are for use with Allowable Strength Design (ASD), and are for flexural members with the compression flange continuously braced. For other conditions of compression flange bracing, the allowable moment must be determined in accordance with the AISI. The design of flexural members must address combined bending and web crippling, and combined bending and shear, as applicable in accordance with AISI. The C-sections listed in Table 1 of this report qualify for use with the prescriptive requirements of the IRC. Track (channel) sections with a flange width of 1.250 inches (31.75 mm) or greater qualify for use with the prescriptive requirements of the IRC. For use of all other sections under the IRC, the cold-formed steel framing members must be limited to engineered structures, in accordance with IRC Section R301.1.3. 4.2 Installation: The framing members must be installed in accordance with the code, the approved plans and this report. If there is a conflict between the plans submitted for approval and this report, this report governs. The approved plans must be available at the jobsite at all times during installation. 5.0 CONDITIONS OF USE The ClarkDietrich C-sections and tracks described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The cold-formed steel members are installed in accordance with the applicable code, the approved plans and this report. 5.2 Minimum uncoated steel thickness of the cold-formed steel members as delivered to the jobsite must be at least 95 percent of the design base-metal thickness. (See page 3 of the ClarkDietrich Cold-Formed Structural Framing Products Technical Design Guide.) 5.3 Complete plans and calculations verifying compliance with this report must be submitted to the code official for each project at the time of permit application. The calculations and drawings must be prepared and sealed by a registered design professional where required by the statutes of the jurisdiction in which the project is to be constructed. 5.4 Framing members having a minimum metallic coating designation of G40 must be limited to use as nonloadbearing interior wall framing subject to a maximum transverse load of 10 psf (478 Pa). 5.5 Framing members with a height-to-thickness (h/t) ratio of more than 200 must be provided with web stiffeners in accordance with Sections B1.2 and C3.6.1 of AISI. Holes or punch-outs in the web for members with a h/t ratio of more than 200 are outside the scope of this report. 5.6 For all applications under the IRC, a G60 galvanization coating designation is required. 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Cold-formed Steel Framing Members (AC46), dated June 2012. 7.0 IDENTIFICATION At a spacing not exceeding 96 inches (2438 mm) on center, each cold-formed steel member is stamped with the ClarkDietrich name or initials; the section name; the evaluation report number (ICC-ES ESR-1166P); the minimum uncoated base-metal thickness in mils or decimal inches; the minimum specified yield strength; and the metallic coating designation CP60 (if G60, A60, AZ50, or GF30 or greater) or G40 (if interior nonload-bearing wall framing).

ESR-1166P Most Widely Accepted and Trusted Page 3 of 3 TABLE 1 C-SECTIONS (STUDS) FOR USE WITH THE IRC IRC MEMBER DESIGNATION 800S162-t 1000S162-t 1200S162-t EQUIVALENT DIETRICH MEMBER DESIGNATION t = 33 t = 43 t = 54 t = 68 t = 97 800S162-33 800S162-43 800S162-54 800S162-68 800S162-97 800S200-33 800S200-43 800S200-54 800S200-68 800S200-97 --- 1000S162-43 800S162-54 800S162-68 800S162-97 --- 1000S200-43 1000S200-54 1000S200-68 1000S200-97 --- --- 1200S162-54 1200S162-68 1200S162-97 --- --- 1200S200-54 1200S200-68 1200S200-97 TABLE 2 MANUFACTURING LOCATIONS ClarkDietrich Metal Framing Hawaii 91-300 Hanua Street Kapolei, Hawaii 96707 (808) 682-5747 ClarkDietrich Metal Framing Riverside 6510 General Drive Riverside, California 92509 (951) 360-3500 ClarkDietrich Metal Framing Woodland 1685 Tide Court Woodland, California 95776 (530) 668-1987

ICC-ES Evaluation Report ESR-1166P CBC and CRC Supplement Reissued August 2016 This report is subject to renewal August 2017. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION: 05 00 00 METALS Section: 05 40 00 Cold-Formed Metal Framing Section: 05 41 00 Structural Metal Stud Framing Section: 05 42 00 Cold-Formed Metal Joist Framing Section: 09 22 16.13 Non-Structural Metal Stud Framing (513) 870-1100 www.clarkdietrich.com info@clarkdietrich.com michael.kerner@clarkdietrich.com CLARKDIETRICH C-SECTIONS AND TRACKS 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that the ClarkDietrich C-Sections and Tracks, recognized in ICC-ES master report ESR-1166P, have also been evaluated for compliance with Chapters 16, 16A, 17, 17A, 22, and 22A of the codes noted below Applicable code edition(s): 2010 California Building Code (CBC) 2010 California Residential Code (CRC) 2.0 CONCLUSIONS 2.1 CBC: The ClarkDietrich C-Sections and Tracks, described in Sections 2.0 through 7.0 of the master evaluation report ESR- 1166P, comply with CBC Chapters 16, 16A, 17, 17A, 22, and 22A, provided the design and installation are in accordance with the International Building Code provisions noted in the master report and the additional requirements of CBC Chapters 16, 16A, 17, 17A, 22, and 22A, as applicable. 2.2 CRC: The ClarkDietrich C-Sections and Tracks, described in Sections 2.0 through 7.0 of the master evaluation report ESR- 1166P, comply with CRC Chapters 5, 6 and 8, provided the design and installation are in accordance with the International Residential Code provisions noted in the master report. This supplement expires concurrently with the master report reissued August 2016. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as Copyright 2016 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 1 1000

ICC-ES Evaluation Report ESR-1166P FBC and FRC Supplement Reissued August 2016 This report is subject to renewal August 2017. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION: 05 00 00 METALS Section: 05 40 00 Cold-Formed Metal Framing Section: 05 41 00 Structural Metal Stud Framing Section: 05 42 00 Cold-Formed Metal Joist Framing Section: 09 22 16.13 Non-Structural Metal Stud Framing (513) 870-1100 www.clarkdietrich.com info@clarkdietrich.com michael.kerner@clarkdietrich.com CLARKDIETRICH C-SECTIONS AND TRACKS 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that ClarkDietrich C-sections and tracks, recognized in ICC-ES master report ESR-1166P, have also been evaluated for compliance with the codes noted below. Applicable code editions: 2010 Florida Building Code Building 2010 Florida Building Code Residential 2.0 CONCLUSIONS The ClarkDietrich C-sections and tracks, described in Sections 2.0 through 7.0 of the master evaluation report ESR- 1166P, comply with the 2010 Florida Building Code Building and the 2010 Florida Building Code Residential, provided the design and installation are in accordance with the International Building Code provisions noted in the master report. Use of the ClarkDietrich C-sections and tracks has also been found to be in compliance with the High-Velocity Hurricane Zone provisions of the 2010 Florida Building Code Building and the 2010 Florida Building Code Residential. For products falling under Florida Rule 9N-3, verification that the report holder s quality assurance program is audited by a quality assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report reissued August 2016. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as Copyright 2016 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 1 1000