CNS LonWorks Serial Gateway Datasheet

Similar documents
16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

Manual Serial PCI Cards

SmartRouters Optionally with Bus Diagnostics RTRS RTRSD

Advanced Data Capture and Control Systems

1-Port R422/485 Serial PCIe Card

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

RJ45 Shielded (standard) port pinout. CS9000, Jetstream , Lanstream 2000, RTA8/RJX, RRC16, MTA8/RJX & SXDC8/RJX

2-Port RS232/422/485 Combo Serial PCI Card

Cable Pinouts. SRP I/O Module

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

ELAN DIGITAL SYSTEMS LTD. SL232 PC- CARD USER S GUIDE

SyncLink GT2/GT4 Serial Adapter

IntesisBox ASCII Server - LON

Technical Description U00980 Revision 2

PCS0100en Persy Control Services B.V. Netherlands

1 Port RS232 Serial over IP Device Server

RS-232 COMMUNICATIONS

LOW COST GSM MODEM. Description. Part Number

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

PCMCIA 1 Port RS EDITION OCTOBER 1999

RC2200DK Demonstration Kit User Manual

Communication standards and Carel solutions

Modular I/O System Analog and Digital Interface Modules

Industrial Multi-port Serial Cards

USB TO SERIAL ADAPTER

Application Note. Terminal Server G6

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Hardware Manual RM CANview Ethernet

Cabling Guide for Console and AUX Ports

LS-101 LAN to Serial Device server. User s Manual

connecdim Gateway G1 Ethernet TCP/IP to DALI

Cable Specifications and Information

User manual Compact Web PLC WP240 series IEC-line

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

TRP-C31M MODBUS TCP to RTU/ASCII Gateway

ELCOMPONENT LTD. User Manual

Alcatel-Lucent OmniPCX Enterprise Communication Server TA-MMK (MMK V2)

Using HyperTerminal with Agilent General Purpose Instruments

Moxa TCC-100/100I User s Guide

Communication Unit 560CMU05 Data sheet

IntesisBox KNX - LON

NPort DE-311 Hardware Installation Guide

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

WHQL Certification Approval...2 User Interface K software FIFO 4 Universal PCI Interface...5 Ready for 64-bit System...5

RS-422/485 Multiport Serial PCI Card. RS-422/485 Multiport Serial PCI Card Installation Guide

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

RS-232/422/485, Power over Ethernet

RouterBOARD minirouter

HARTING econ 3000 Introduction and features

USB to serial chip CH340

IP SERIAL DEVICE SERVER

How to setup a serial Bluetooth adapter Master Guide

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Cable Guide. Click on the subject to view the information. Digi Cables Building Cables General Cable Information

Auxiliary equipment for communication with the EuroProt protective devices

2/4/8 Port USB to Serial Adapter Hub with COM Retention

IntesisBox KNX LG Air Conditioning

Easylon For Automation with LonWorks Interfaces Connecting to LonWorks Software LonWorks Data Access Network Components From Repeater to Terminator

DK40 Datasheet & Hardware manual Version 2

1.1 Connection Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking

IntesisBox Modbus Server Fidelio IP

Telephone- and leased line modem for industrial applications TD-36

One Port Serial Server Users Manual Model ESP901, ESP901E

R60 USB to CAN interface Manual (1.5 EN)

2-port RS-232 High Speed Low Profile Universal PCI Serial Board

Professional USB to Serial Adapter Hub with COM Retention

WHQL Certification Approval...2 User Interface...3 SUNIX s COMLab..4

Application Note 83 Fundamentals of RS 232 Serial Communications

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Quick Design & Install Guide. Computerised Emergency Evacuation System LONWORKS TM Powerline Technology

Rack mounted telephone- and leased line modem for industrial applications

Computer Control of Satellite Antennas

Hardware Reference. Linux Device Server IGW/922 with DIL/NetPC ADNP/9200

SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2

How To Set Up A Modem (Marc) Model (Marc) Model 2 (Marr) Model 1 (Marm) Model 4 (Mariar) Model 8 (Marp) Model 6 (Mar

C232HD. USB 2.0 Hi-Speed to UART Cable. Datasheet

IntesisBox KNX Mitsubishi Heavy Industries AC

Variable Preset Counter signo 723.1

M3 Single-Slot Cradle. User Guide. Cradle Model: A-1CR-U R00, A-1CR-U00D-040-R00, A-1CR-US R00, A-1CR-U0ED-110-R00

Comtrol Cable User Guide

Using Xbee in Serial Communication

Application/Connection Examples

IPG/7700 Hardware Manual SYSTECH. Document number Revision A

EMS. EtherCAN CI. Ethernet/CAN Interface. User Manual THOMAS WÜNSCHE. Documentation for Ethernet/CAN interface EtherCAN CI version 2.1.

Serial over Ethernet Device Server. User s Manual

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

PCAN-ISA. CAN Interface for ISA. User Manual

Connecting the Console Port to a PC

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

LonManager PCC-10 and ISA Protocol Analyzers Models and

Industrial Bar Code Scanners

Introduction. Features. Industrial 2 ports RS-422/485 with Surge PCI-Express Low Profile Serial Card

maxon motor maxon motor control EPOS Positioning Controller Cable Starting Set Edition June 2006 part number Positioning Controller

LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual

GadgetGatewayIa Configurable LON to IP Router and/or Remote Packet Monitor. ANSI (LonTalk ) and ANSI 852 (IP) standards based.

ETM9350-1/ Quick Start Guide

Transcription:

CNS LonWorks Serial Gateway Datasheet Features LonWorks transceivers type 78Kb/s twisted pair Free topology transceiver (FTT 10A), Din Rail High Speed RS-232/ RS-485 Interface up to 115.2 kbps 24V AC/DC powered LED and service LED's for both sides of the gateway LonMark, LNS compliant CE, RoHS Description The Serial Gateway provides a serial interface between RS 232 or RS-485 and LONWORKS networks offering data transfer rates of up to 115.2 kbps. The Neuron chip maps the interface to the LON side. By default, the unit works with standard software SPA (Serial PC Adapter) in FLASH for network access from a PC (Note: not LNS compatible). All received network messages or network variable updates are sent to the PC. Messages from the PC are transferred to the network. The serial transmission is controlled by the SPA protocol. The PC software library supports receive and send operations similar to those in Neuron C. These functions and the underlying data structures make the implementation of network management tools and visualisation software easy. It can be used for connecting PCs, printers, modems, or any other equipment with serial interface to a LonWorks network. 17/10/11 1 v0.3

On request we can supply a driver DLL which can be used to create your own Windows applications with Lon access via this Serial Gateway. The unit is an excellent platform for custom specific programming (including gateway functions or customised protocols) due to the flexible memory configuration (FLASH and RAM) as well as the unlimited access to the serial data lines. For the implementation of your own proprietary protocols in the firmware, a Neuron C library is available under signed license (free of charge). We also offer a Custom Software engineering service and would be pleased to quote against your Requirement Specification document. Caution: Installation by qualified personnel only. Observe established engineering procedures and CNS s published data. Be careful when connecting power! Please note that CNS supplies a complete range of Lon Network Infrastructure Products (NIP s) and Internet Lon Network Infrastructure Products (INIP s) including Physical Layer Repeaters, Lon Terminators, LonRouters (inc Fibre), Lon/IP 852 & Lon/ WiFi 852 Routers please visit our web site www.control network solutions.co.uk for more information. For additional information regarding use of these products please, refer to CNS LonWorks Router Guide and CNS LonWorks Din Router Installation Guide. Please note that CNS supplies a complete range of Lon Network Infrastructure Products (NIP s) and Internet Lon Network Infrastructure Products (INIP s) including Physical Layer Repeaters, Lon Terminators, Lon/IP 852 & Lon/ WiFi 852 Routers please visit our web site www.control network solutions.co.uk for more information. Specifications Mechanical Din mounted Bracket can be fitted to underside of unit. Unit is suitable for fitting on DIN 46277 and DIN EN 50022 mounting rail 17/10/2011 2 v0.3

Connections and Status LED s Fig 1 The TP/FT-10 Lon interface is provided via the RJ-45 and 4-pole cage clamp connectors. For more details regarding TP/FT-10 media please refer to the FT3120/FT3150 Smart Transceiver Data Book available from the Echelon Corporation. Terminal Configuration LON Port RJ - 45 This device can be supplied with power via the RJ 45 connector (Pins 3 and 4). The Power Jack and RJ 45 power supply paths are decoupled by diodes, but are not galvanically isolated. For pin assignments see Terminal Assignments table on the next page. Warning: Use only one power supply path to power the device! Please observe the guidelines concerning the cable length and recommended cable types, published by Echelon Corporation and the LONMARK Interoperability Association. 17/10/2011 3 v0.3

Serial Port Connecting Lon Serial Gateway to a PC PC connector Signal IFMS RS232 25 pin D-sub 9 pin D-sub 9 pin D-sub 3 2 RxD 2 2 3 TxD 3 7 5 GND 5 4 7 RTS (optionally) 7 5 8 CTS (optionally) 8 Note: Potential differences between the ground of the serial connector and the power supply may destroy the device. Avoid potential differences by using a galvanically isolated power supply unit. Connect Lon Serial Gateway to a Modem Modem connector Signal IFMS RS232 25 pin D-sub 9 pin D-sub 9 pin D-sub 3 2 RxD 2 2 3 TxD 3 7 5 GND 5 4 7 RTS (optionally) 7 5 8 CTS (optionally) 8 6 6 DSR (optionally) 4 8 1 DCD (optionally) 1 20 4 DTR (optionally) 6 22 9 RI (optionally) 9 17/10/2011 4 v0.3

Terminal Assignments Terminal Function TP/FT-10, supply - RJ45 connector 1 LON-Bus TP/FT-10, NET B 2 LON-Bus TP/FT-10, NET A 3 +24 V 4 GND 5, 6, 7, 8 n.c. D-Sub connector female 9 poles 1 RS232 DCD input RS485 RS485 B / DCD bidirectional / input 2 TxD output 3 RxD input 4 DSR input 5 GND 6 DTR output 7 CTS input 8 RTS output 9 RI input RS485 bidirectional A / RI / input Dedicated power supply connector (barrel jack, e.g. Lumberg NES/J 21) Outside +24 V Inside GND TP/FT-10, power plug-in cage terminal (to be used alternatively to RJ45) 1 LON-Bus TP/FT-10, NET A 2 LON-Bus TP/FT-10, NET B 3 GND 4 +24 V Serial Port RS 232/485 (D SUB 9 Jack) The RS232- and/or RS485 interface is provided by the D-Sub female connector. For connecting the device to a PC with a RS232 extension (male to female, 1:1) or to a Modem with a cable with crossed lines (male to male) cable, at least RxD, TxD and GND are mandatory. Configuration RS232 / RS485 Default configuration with SPA standard application: 4800 Baud, 8 data bits, No parity and 1 stop bit (4800, 8N1). Change of configuration in configuration mode (always 4800, 8N1): Connect device with the serial interface of a PC that runs a terminal program (e.g. Windows Hyperterminal, 4800, 8N1). For entering configuration mode press and hold the service button when connecting the device to power supply. An interactive menu will appear that allows changing the serial interface parameters. 17/10/2011 5 v0.3

For the RS-485 version bus lines are on pins 1 and 9 of the D-sub connector when working in RS-485 mode. Note: The power supply lines of the RJ45 connector and of the 4-pole connector are not decoupled from each other (see fig 1 above.). The dedicated power supply connector is decoupled from the other power supply connectors by diodes, but not galvanically isolated. Power Supply Adapter Jack Barrel Jack for Lumberg NES/J 21 Pin diameter is Opening diameter is Centre Outer 1.95 mm 6.0 mm GND 24VAC/DC Note: Exceeding the indicated voltage range can damage the device! The device can be supplied alternatively via RJ45 connector, 4-pole connector or dedicated power supply connector. Caution: Installation by qualified personnel only. Observe established engineering procedures and published data. Terminals TP/FT-10 / Supply -RJ45 Type RJ45, unshielded TP/FT-10 / Supply -Cage Clamp Type plug-in cage clamp Rated cross section 1.5 mm2 Clamping range 0.08 mm2 to 1.5 mm2, AWG 26 to AWG 14 Insulation stripping length RS232 Type Supply 10+1 mm 9 pin D-sub connector female Type barrel jack, e.g. for Lumberg NES/J 21 Diameter opening/pin 6.0 mm / 1.95 mm 17/10/2011 6 v0.3

Electrical Technical Processor Memory Lon Transceiver Supply 3150 @ 10Mhz 32K FLASH + 25KiB SRAM ( Other options up to a maximum of 64KiB Flash + 32KiB SRAM available on request) FTT10A, (RS 485 available on request) AC DC Power 0.6W Environmental 19.2 V to 28.8 V 10 V to 33 V Operating Temp Storage Temp Relative Humidity Rating Packaging Weight -40 to +70 C 40 85 C 0 75% (annual average non condensing) IP20 110g approx Dimensions 101 mm x 25 mm x 61 mm / 3.98 " x 1.00 " x 2.4 " Material Certification ABS 94 HB CE EN 55022, class B, EN 61000-4-4, EN 61000-6-2, EN 61000-4-2, EN 61000-6-2, EN 61000-4-3, EN 61000-6-2, EN 61000-4-6, EN 61000-6-2 Reference documents for installation and network topology issues; Echelon LonWorks FTT 10A Transceiver User s Guide, 078 0198 01D Echelon LPT 11 Link Power Transceiver User s Guide, 078 0198 01A Echelon Twisted Pair Transceiver User s Guide, 078 0025 01C FT3120/FT3150 Smart Transceiver Data Book Ordering Information Part No. = CNSSGS/2/RS-232/DIN CNSSGS/2/RS-485/DIN 17/10/2011 7 v0.3

Contact Control Network Solutions Ltd Studio 7, Intec 2, Intec Business Park, Wade Road, BASINGSTOKE, Hampshire, RG24 8AG, England Tel: +44 (0) 1256 818700 Fax: +44 (0) 1256 812520 Email: cns@control-network-solutions.co.uk Web: www. control-network-solutions.co.uk No part of this publication may be reproduced or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, in part or in whole, without prior permission of Control Network Solutions. We reserve the right to make changes without notice to any products herein as part of its continued product development and improvements. We do not assume any liability arising out of the application or use of any product or circuit described herein. Lon, LonWorks, LNS, RTR 10, FTT 10A are all trademarks of Echelon Corporation. 17/10/2011 8 v0.3