Be careful not to scratch or hit front edge of the side viewing micro prisms onto hard objects!



Similar documents
Optilia Instruments. Empowering Your Vision!

How To Connect An Optilia Frame Grabber To A Pc With A Blackmagic Wd Capture On A Black Magic Camera On A Microsoft Hd Camera On An Optipix 2.5D (Blackmagic) On A Usb 3

National Optical & Scientific Instrument Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Handheld USB Digital Endoscope/Microscope

4.3-inch Back-Up Camera

User Guide LUXXOR VIDEO MICROSCOPE. 2 Luxxor Video Microscope Set Up

Remote Head REMO ONE. Code Manual

Handheld USB Digital Endoscope/Microscope

Smart Cam, CC-Smart-Cam, and Smart Cam Packages Installation and Quick Start Operating Instructions

PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES

Operating Instructions Bedienungsanleitung Mode d emploi

SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC

SP AF 300mm F/2.8 LD [IF] for Canon (Model 360EE)

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

CALIBRATION FOR LAL20X & LAL24X

CS Digital Microscope User Manual

TEC APO140. This telescope is closer to optical perfection more than any instrument I have ever used before. R.Renzi, Italy.

DIY Wearable Pi with Near-Eye Video Glasses

TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions

50 TO 60 INSTALLATION INSTRUCTIONS v1.0

Parts List. The HyperStar Lens Assembly includes three pieces: HyperStar Lens Secondary Mirror Holder Counterweight

POLEMOUNT FIELD FIX ASSEMBLY INSTRUCTIONS

aseries A13B Mini Bullet Camera User Manual

16/32 Channel 1U Rack Mount CCTV Power Supply

TAGARNO AS Sandøvej Horsens Denmark Tel: Mail: mail@tagarno.com

MT-30 & MT-90 Series. Advanced Academic Microscopes/ Advanced Academic Polarizing Microscope INSTRUCTION MANUAL

Service Guide. Gateway M275

Installing Cisco TelePresence MX200 G2 - Wheel Base

4RU High Density Shelf Installation Instructions

ST-80 MICROSCOPE With Electronic Eyepiece #6810. User Guide

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

FirstView 3 Reflector Telescope Owner s Manual

TL-12 Passenger Car Alignment System

AN114. Scope. Safety. Materials H AND SOLDERING TUTORIAL FOR FINE PITCH QFP DEVICES. Optional. Required. 5. Solder flux - liquid type in dispenser

EasyNote TJ Series. Disassembly Manual

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Copyright. Trademarks. FCC Compliance. Equipment Recycling. Leaf Imaging Ltd., 20. All rights reserved.

V

User Manual. Flextight X5 / X1 English v/1.3

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

Auto Sentry-eXP Maintenance

MDU SC Connector Termination Procedure

Step-by-step instructions:

Fiberstars Lighted Laminar Flow Fountain Installation Manual

REDWALL-V adjustment procedures guide

Network Bullet Camera. Quick Operation Guide KNC-p3BR28V12IR

Beam Laser Pointer Service Manual

1500 Follow Spot Yoke

MRC High Resolution. MR-compatible digital HD video camera. User manual

Triac Printed Circuit Board Replacement

Manual for GlobePharma Mini-Press II Rotary Tablet Press

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY

SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide

T H A N K Y OU F O R Y OUR P U R C H A S E O F A N E S S E N T I A V A N I T Y, P L E A S E R E A D T H E S E V A N I T Y C A R E A N D I N S T A L L

MAINTENANCE & TROUBLESHOOTING

Care and Use of the Compound Microscope

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

PROFESSIONAL REFRACTOR MODEL

IP Camera User Manual

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

RS Monitor Backlight Replacement

Mini-led spotlight with magnetic base

HP ProLiant DL165 G7 Server. Installation Instructions

SC 7000 and SC 9000XL Patient Monitors SC 9000XL Monitor 12in (30.5cm) Display Service Manual Supplement Two

Global Water Instrumentation, Inc.

Day / Night IR Color Camera User Manual V2.1.0

PREVENTIVE MAINTENANCE OF FIBER OPTIC CABLES AND OPTICS

Data-Logging Rain Gauge PRODUCT MANUAL

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

VISM Evolution Scope Series

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Features: Mounting the Optic

GenStore Archive Cabinet

Router. A. Identify the major parts of the router. B. Complete a written test on safety and operating procedures of the router with 100% accuracy.

Quick Start Guide. Digital Inverted Microscope. The Microscope Evolved.

Contents. Unboxing. Getting started. Troubleshooting and FAQs. Trademarks and copyrights. 2 Contents

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Periodic Verification System Model 775PVS

2M IR Mini Dome Quick Installation Guide

USB Dual Handset Adapter for Nortel 1100-Series IP Phones

Installing the Video Input and TV Tuner Cards in a Compact Computer or a Dual PCI-Slot Tower Computer

Installation Instructions

Raritan LCD KVM Console (T1700/T1900)

SC, FC and ST * Hot Melt Fiber Optic Connectors

DIY Y6. Build Manual V.A 2014

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

SERVICE PARTS LIST PAGE 1 OF 6 BASE ASSEMBLY SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 12" DUAL BEVEL COMPOUND MITER SAW B27A

ECM-D70T / ECM-D70T1.5

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

TerraWave Solutions MIMO Site Survey Battery Pack (Part # TW-SSBP-007) Instructions For Use

Action Camcorder Rollei Youngstar USER MANUAL

MT-RJ Connectors Termination Procedure

7. Computer System Minimum Requirement Troubleshooting. 32. PortableCapture Pro Software Introductions...33

Transcription:

Instructions Manual Flexia BGA Inspection Systems This manual describes how to use Flexia BGA Inspection System Optilia Instruments 1 AB

Contents 1. Safety and maintenance Instructions 3 2. About Flexia BGA 4 3. Mounting Flexia BGA 5 4. How to attach Background Illumination 6 5. How to calibrate magnifications of BGA lens in OptiPix 7 6. How to Inspect BGA solders 8 7. Zoom, Focus and Image tilt adjustments 9 8. Changing Optical Head 9 9. Notes 10 2

1. Safety and maintenance Instructions Do not scratch or hit front edge of the side viewing prisms onto hard objects! This precaution is important especially when you operate Flexia BGA mobile ion free hand. Only use DC Power Sources provided or approved by Optilia. Only use accessories provided or approved by Optilia. Keep the equipment clean. Use Lens Cleaning Tissue and Pure Ethanol or Isopropyl alcohol for cleaning optical surfaces of the device. Never use Acetone or other similar solvents for cleaning. Never knock or drop the video microscope. Keep video microscope away from direct sun-light, heat and extreme humidity. Store the equipment inside case when not used. Protect the BGA lens, Objective lens and Zoom lens by the supplied protection Rubber Caps or store them inside their boxes when the equipment is not used. This equipment is a precision optical device and shall be handled with great care! Be careful not to scratch or hit front edge of the side viewing micro prisms onto hard objects! 3

2. About Flexia BGA Flexia BGA is a mobile Video Microscope designed for visual inspection, digital image recording and software measurements of solder joints of BGA, mbga, CSP, Flip-Chip packages. Flexia BGA can also be used for visual control of pads, solders, components etc on PCBs in the production plants as well as in the laboratories and for R&D. Zoom & Focusing ring Image capture Switch On/Off switch and indication LED Illumination Control Optical Head 12/5 VDC output (for BrushLight) Image tilt adjustment Zoom lock Threaded hole for Stand (UNC ¼ -20) Flexia BGA analogue is directly plugged to a video monitor or TV. Flexia BGA digital is plugged to PC or laptop via USB2.0. In addition, Flexia analogue can also be connected to a Laptop or PC via Optilia s High speed USB2.0 or FireWire Frame Grabbers. For installation of Flexia digital or Frame Grabber drivers to your computer please refer to instructions manual of the specific devise. (PC USB2.0 port directly if Flexia Digital) (USB2 (PAL/NTSC (USB2.0 or FireWire Frame Grabber if Flexia analogue) PC/Lap-top (direct USB2.0 port) TV/External Display (PAL/NTSC) PC/Lap-top( via FG) 4

3. Mounting Flexia BGA Remove the lens-protecting caps and attach the BGA lens onto the Flexia as illustrated. 1. Remove the protecting caps from Flexia and BGA lens first. 2. Gently push the BGA lens inwards to click. (Snap position). Assemble Brush Light- and Focusing Stands as illustrated. Mount Flexia BGA to the stand as illustrated below. BGA lens must be aligned to the stand base at right angles precisely. Connect the dissipative mat to GND for ESD-protection. Connect Flexia to Power and monitor (if analogue sensor) or to USB2.0 port of your PC (if digital sensor). Install Flexia Digital drivers first, before connecting the device to PC. 1. Assemble stands 4. Mount Flexia and connect to PC or Power Supply 2. Lock Brush Light into its holder 3. Connect to Earth for secure ESD-protection 5

4. How to attach Background Illumination (Optional, only if you have purchased the Background illumination) Insert BGA lens carefully into the ring of the Illumination device. Align front side of the illumination to the white mark on front side of the BGA lens and fix it by tightening the screw. Plug the DC connector into AUX output of Flexia Cable for power. Connect to DC output of Flexia Cable for power. Align Illumination ring to the white mark on the BGA lens Insert BGA lens into the ring Position set screw Loosen the illumination position screw to move illuminator forward/backward. Pull down optical head gently until contact with the PCB surface. Light intensity is controlled by dimmer knob. Dimmer knob Loosen screw to move illuminator forward Loosen this screw and pull down optical head to contact with PCB 6

5. How to calibrate magnifications of BGA lens in OptiPix (Optional, only if you have purchased OptiPix Full software) Zoom ring of BGA lens is marked by Greek numbers I, II, III and IV. These positions indicate different optical magnification of the lens and can be calibrated in OptiPix software to perform dimensional measurements. Magnification position fix screw Magnification position marks a. Define 4 magnifications in OptiPix. (refer to instructions manual of OptiPix for how to define magnifications). b. Put the provided Calibration Micrometer Scale on top of the BGA component (top of the die). Fix position of the Zoom ring to the first magnification and move the calibration scale forward/backward and/or sideways until you achieve a sharp picture of the printed scales on the glass substrate. If available, use of XY-table is preferred. c. Calibrate this magnification and do same procedure for other magnifications. Front side of the Calibration scale Calibration Scale Note: Accuracy of the calibration (and dimensional measurements) is higher at high optical magnifications. Performing dimensional measurements is not recommended at low optical magnifications due to large depth of focus and image distortion of BGA lenses at low magnification. 7

6. How to inspect BGA solders Turn on Flexia. Put the PCB on the stand base. Adjust height of the Rack & Pinion roughly. Use the Rack & Pinion unit to slide down Flexia to a few millimeters above the BGA package. Fine adjust position of BGA package against optical head of Flexia BGA and move down Flexia BGA slightly and carefully to contact with the PCB surface. Do not press BGA lens to the PCB. 1. Move down Flexia BGA gently to get in touch with the PCB surface next to the BGA package. 2. Tilt the Brush Light appr. 45 deg. and position tip of the optical fibers to edge of the BGA component. Tilt the Brush-Light approximately 45º and position tip of the optical fibers to edge of the BGA component by adjusting the Brush Light Stand. Turn on the Brush Light to insert background illumination underneath BGA component. Adjust intensity of the background Illumination by turning the Brush-Light knob. 3. Loosen locking screws and move the brush light toward the BGA package. Solder ball without background light DC-adapter Solder ball with background light 4. Turn on the light and adjust illumination intensity. Note: Brush-Light is powered by battery or by Flexia. Switch battery tube with DC-adapter (optional) and connect it to AUX output of Flexia cable to power the illumination via Flexia Cable. Power supply must be connected to Flexia Cable! 8

7. Zoom, Focus and image tilt adjustment Image magnification as well as object distance of the BGA lens can be adjusted by turning focus ring of the lens. Horizontal plane of the image (Image tilt) can also be adjusted by rotating optical head of the BGA lens about its axis a few degrees. Turn the zoom ring in order to focus deeper underneath the BGA component. 1. Move down Flexia to contact with PCB surface. BGA lens must be at 90 o to the PCB. 2. Rotate Zoom Ring to alter object distance and focus! 3. Rotate optical head to adjust horizontal plane of picture if necessary. 8. Changing Optical Head of the BGA lens Optical Head of BGA lens can be replaced in case of damage or aging. 1. Unscrew the ring and pull out the Optical Head Note: Micro prisms on the tip of the Optical head are protected by mechanical housing. These can still be damaged if pressed against hard edges. 9

9. Notes 10

11

All rights reserved. The information contained herein is designed only for use with Optilia Instruments AB,s video microscope Flexia BGA. Optilia Instruments AB is not responsible for any use of this information for other purposes. Optilia Instruments AB shall not be liable to the purchaser of this product or third parties for damages, losses, costs or expenses incurred by the purchaser or third parties as result of: accident, misuses, or abuse of this product or unauthorized modifications, repairs or alternations to this product, or failure to strictly comply with Optilia Instruments AB s operating and maintenance instructions. Optilia Instruments AB shall not be liable for any damages or problems arising from the use of any options or any consumable products other than those designated as original Optilia products or Optilia approved products by Optilia Instruments AB. Optilia Instruments AB shall not be held liable for any damages resulting from electromagnetic interference that occurs from the use of any interface cables or devises other than those provided by or designated as Optilia-approved Products by Optilia Instruments AB. Djupdalsvägen 22 S-192 51, Sollentuna Sweden Phone: +46 (0)8 35 33 60 Fax: +46 (0)8 35 33 63 E-mail: Info@optilia.eu Web: www.optilia.eu RevG, April 11 12