source at CERN G.McMonagle AB/RF



Similar documents
14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

FIVE PROJECTS OF HIGH RF POWER INPUT COUPLERS & WINDOWS FOR SRF ACCELERATORS*

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

K O M A C. Beam Commissioning of 100-MeV KOMAC Linac. Korea Multi-purpose Accelerator Complex 양 성 자 가 속 기 연 구 센 터

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Linac RF Commissioning with the SNS HPRF Systems

Institute of Accelerator Technologies of Ankara University and TARLA Facility

10 Project Costs and Schedule

CLIC accelerator and detector

Results: Low current ( ) Worst case: 800 MHz, GeV, 4 turns Energy oscillation amplitude 154 MeV, where

& Tunnel Cross Section

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Experiment 5. Lasers and laser mode structure

The VSS3605, a 13-kW S-Band GaN Power Amplifier

AUTOMATIC NETWORK ANALYZER PROCEDURES FOR 5045 KLYSTRON CAVITIES * J.G. Judkins

Industrial Involvement in the Construction of Synchrotron Light Sources

Ultra640 SCSI Measured Data from Cables & Backplanes

4 Posiflow Proportional Solenoid Valves

38 Series - Relay interface modules A

38 Series - Relay interface modules A

Design and Test of Fast Laser Driver Circuits

RF SYSTEM FOR VEPP-5 DAMPING RING

Measuring Laser Power and Energy Output

Welcome to the combined product training module of Linear Technology and Wurth Electronics about their efficient design solution for DC/DC Flyback

THE TESLA TEST FACILITY AS A PROTOTYPE FOR THE GLOBAL ACCELERATOR NETWORK

GaN or GaAs, TWT or Klystron - Testing High Power Amplifiers for RADAR Signals using Peak Power Meters

Tom Wilson Product Marketing Manager Delivery Systems Varian Medical Systems International AG. CERN Accelerator School, May 2015

Pulsed Power Engineering Diagnostics

High Power Tests of Beryllium Oxide Windows to the Lower Hybrid Current Drive Launcher in JET

Selected Radio Frequency Exposure Limits

Dynamic Frequency Selection Requirements

INSTRUCTION FOR COMPLETING COMPETITIVE SOLICITATION ACKNOWLEDGEMENT FORMS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z

ipimms is an industry primary impedance measurement service supplied and maintained by UK s National Physical Laboratory. [4]

NUCLEAR MAGNETIC RESONANCE. Advanced Laboratory, Physics 407, University of Wisconsin Madison, Wisconsin 53706

RF Measurements Using a Modular Digitizer

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

RF Power Amplifier PA10W Owner s Manual SpinCore Technologies, Inc.

Centro-Matic Automatic Lubrication Systems System Controls

KLYSTRON TUNING PROCEDURES:

ESS industry day Introduction to Imtech Power Conversion

Remarkable achievements

A Compact Linac for Proton Therapy Based on a Dielectric Wall Accelerator

Teseq ESD Simulator Verification

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

Rack mounted telephone- and leased line modem for industrial applications

Short overview of TEUFEL-project

HOMER Analyzer ISM 2.45 GHz, R-26 Waveguide

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Reliability and Availability Aspects of. the IPHI Project

5495A DM Bit Parallel Access Shift Registers

MasterINTERFACE 39 Series - Relay interface modules

Cleaning Methods of SRF Power Couplers. Mircea Stirbet

LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE

HERZ-Thermal Actuators

GSM Testers for Rent and Sale

ULTRAFAST LASERS: Free electron lasers thrive from synergy with ultrafast laser systems

Experiment 7: Familiarization with the Network Analyzer

RF and Microwave Accessories. CD-ROM Catalog. Find the right component for your Rohde & Schwarz test & measurement equipment

ECE 435 INTRODUCTION TO THE MICROWAVE NETWORK ANALYZER

Case Studies in On-Line Measurement of PD in Motors Fed by Voltage Source PWM Drives

Location-Aware and Safer Cards: Enhancing RFID Security and Privacy

ESS Proton Linac Accelerator Project Leader: Mats Lindroos Roland Garoby Technical Director Ankara - October 6, 2015

KONSTANTER SPL / SPL Programmable Electronic Load

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

Impedance 50 (75 connectors via adapters)

80 Series - Modular timers 16 A. Features

Test Report #: Date: April 8, 2005

Turku University Of Applied Sciences Ltd furniture and equipment for the student laboratories of the degree programme in dental technology 1 (9)

Cathode Ray Tube. Introduction. Functional principle

Application Note. Line Card Redundancy Design With the XRT83SL38 T1/E1 SH/LH LIU ICs

Nexus FS Point of Use Installation Guide

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

INSTRUCTION MANUAL for UNIBLITZ MODEL DM412 SHUTTER DRIVE MODULE

The STAR Project: Southern european Thomson source for Applied Research

15 Series - Electronic step relay and dimmer. Features SERIE

MasterINTERFACE 39 Series - Relay interface modules

The Best Relaytion. Reed Relays Rev. B EC-JM ECOC: JM10 1. Aug. 04

Principles of Adjustable Frequency Drives

Status of High Current Ion Sources. Daniela Leitner Lawrence Berkeley National Laboratory

Name: Air Conditioning, Heating and Refrigeration ( )

How To Develop An Inertial Fusion Energy

STPS40L15CW. 2 x 20 Amps SCHOTTKY RECTIFIER. Case Styles. I F(AV) = 40Amp V R = 15V. Bulletin PD rev. B 10/06. Description/ Features

Navi-Radar 4000 and Navi-Sailor 4000 ECS for workboats and small crafts BIG SOLUTIONS FOR SMALL VESSELS

Standex-Meder Electronics. Custom Engineered Solutions for Tomorrow

TRAMS TROLLEY-BUSES SUBWAY

K817P/ K827PH/ K847PH. Optocoupler with Phototransistor Output. Vishay Semiconductors. Description. Applications. Features.

EMI Profile of Ephesus Stadium Lighting System

High-Megawatt Converter Technology Workshop for Coal-Gas Based Fuel Cell Power Plants January 24, 2007 at NIST

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER

Cat Electronic Technician 2015A v1.0 Product Status Report 6/3/2015 4:41 PM

Home Passport Gateway Series Simplify your Life with Smart Solutions

54191 DM54191 DM74191 Synchronous Up Down 4-Bit Binary Counter with Mode Control

Alpha 10 SERVICE MANUAL. Downloaded from MAX 10 Meter Amateur Transceiver AM/FM/CW/SSB 6 BAND PROGRAMMABLE MODEL AM-1000.

Transcription:

12 GHz Stand alone power source at CERN G.McMonagle AB/RF

Objectives Install a 12GHz power source at CERN as soon as possible to allow high gradient structure testing independent from the CTF3 machine operations GOAL is for early 2009

Where? 1 st Floor B 2013 CTF3 Complex 9.2m 4.9m Zone B 4.5m Zone A 2.7m Zone A Old CTF2 Streak Camera area Space available now Installing the klystron modulator in 2013 suitable for 1 klystron modulator allows for a stand alone test area below in Zone B the CTF2 area but also allows the possibility CTF3 Laser Room to provide 12GHz RF power to the CLEX area Space NOT available immediately suitable for 2 klystrons and modulator

Requirements for 2009 in zone A Modulator test slot 200 MW, 0... 100 ns or 100 MW, 0... 350 ns phase modulation hybrid Klystron 50 MW 1500 ns 50 Hz pulse compression

Klystron Specification Parameter Value Units RF Frequency 11994.2 MHz Peak RF power > 50 MW RF Pulse Width 1.5 µs HV pulse width Approx 3 to 3.5 µs Repetition Rate 50 Hz No existing klystron to this specification Klystron will probably bl be scaled from 11.4 GHz model with solenoid focussing Already in consultation with klystron manufacturers to see if parameters and time delay for manufacture are achievable Other european laboratories are interested in similar klystron (PSI, Trieste, Frascatti)

Provisional Modulator Specification based on SLAC XL4 tube at 50 MW Parameter Value Units Peak Klystron Voltage Peal Klystron Current 410 kv 310 A HV flat top 15 1.5 µs Max HV pulse width Approx 3 to 3.5 µs Repetition Rate 50 Hz Final paramaters for modulator only after klystron model is chosen Some size restraints on individual modulator components will be necessary due to the chosen location Open to choice of line type thyratron switch or solid state development Possible collaboration with other labs depending on thier timescale

Additional requirements Lead shielding of klystron water cooling distribution Preparation of test area 3 phase power requirements r (TS/EL) Low level RF including klystron driver Waveguide network including high power loads, measurement couplers, hybrid and pulse compressor. Apart from pulse compressor, development already underway for CLEX two team test t stand

Strategy Finish consultation with klystron manufacturers and prepare costing and delivery timetable in order to present a collaboration proposal to FC in December 2007 for approval Order klystron Finish modulator specification with respect to above decisions i Price enquiry for modulator Cost analysis for infrastructure in B.2013 Prepare test area in parallel to klystron and modulator orders Price enquiries for low level equipment necessary and for manufacture of high power waveguide network

Ball park cost estimates for single klystron power source DESCRIPTION COST ESTIMATE (kchf) DELAY Klystron 640 12-18 months Modulator 650 12-14 months Water cooling 25 3 phase supply 25 Zone preparation 40 Klystron driver (~300 to 50 8-12 months 500 watts) Low level electronics 30 Low level controls 30 General infrastructure 50 Vacuum tanks 50 High power RF 200 components Vacuum equipment 50 Process control system 100 TOTAL material estimate 1940

Optimistic Planning Klystron feasibility and costing enquiry Finance Committee Approval (for klystron collaboration and project approval) Order Klystron Klystron Manufacture and Delivery Modulator Price Enquiry Modulator Manufacture and Delivery Preparation of Modulator area Procurement and preparation of auxiliaries Preparation of test area Procurement and manufacture of test area equipment Low level RF START TEST STAND COMISSIONING (single klystron) 2007 2008 2009 1112123456789 10 11121234567

Summary We have a very tight and optimistic programme to deliver a 12 GHz RF power setup at CERN for early to mid 2009 Only workable if we get immediate CERN approval or external funding Suggestions and HELP (financial or inkind contributions) in achieving these goals would be welcome