Maintenance Philosophy. Service High Voltage Products, Transmission GIS, January 2012 ELK 1, 2, 3

Similar documents
MODEL 565E - 22 TON AIR/HYDRAULIC AXLE JACK

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Buy Karcher Parts Online: Need Technical Help? Call: Requests to:

Service Power Technologies. Retrofitting A future-oriented concept in lifecycle management

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

ABB s Disconnecting Circuit Breakers Higher substation availability and lower environmental impact

Proactive Asset Management for GIS A six step process for reducing risk, cost, and improving reliability

Buy Karcher Parts Online: Need Technical Help? Call: Requests to:

ABB Fuses Competitive Advantages

Erik Backström, High Voltage breakers, After Sales & Service High voltage SF 6 live tank circuit breakers After Sales & Service Training course

Residual life aspects on GIS with the focus on SF 6

Preliminary Results from Present Cigre Survey

Disconnectors and Earthing Switches 36 kv up to 800 kv

Advantages of Fixed Circuit Breaker Switchgear

P a r t s L i s t. P a r t s L i s t. Date: Page: 1

UFES Active protection for switchgear

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Product brochure. GMS600 monitoring system for generator circuit-breaker State-of-the-art monitoring

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

K&T Saw Shop or MC 91C 11/74 to 04/76 IPL Page 1 of 11 Accessories

PART 2 FORKLIFT HYDRAULIC SYSTEM

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R EN - Edition 02-21/04/2005

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

DR90. Baja Motorsports Inc. P.O. Box Phoenix, AZ Toll Free: PART NUMBERS AND PRICES ARE SUBJECT TO CHANGE 1 of 51

DR90. Baja Motorsports Inc. P.O. Box Phoenix, AZ Toll Free: PART NUMBERS AND PRICES ARE SUBJECT TO CHANGE 1 of 51

1/29/2008 DR50. Baja Motorsports Inc. P.O. Box Phoenix, AZ Toll Free: PART NUMBERS PRICES ARE SUBJECT TO CHANGE 1 of 45

BRAKE SYSTEM OVERVIEW AND OPERATION PROCESS 1. BRAKE SYSTEM GENERAL INFORMATION 1) DESCRIPTION AND OPERATION 16-3.

Information and Instructions

BR150 Pmi Baja Reaction 150cc Go Kart (VIN PREFIX L4VM)

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

PARTS LIST T30 MODEL 2545 TWO STAGE INDUSTRIAL AIR COMPRESSOR

1/29/2008 DR70. Baja Motorsports Inc. P.O. Box Phoenix, AZ Toll Free: PART NUMBERS PRICES ARE SUBJECT TO CHANGE 1 of 43

P a r t s L i s t. P a r t s L i s t. Date: Page: 1

ABB Power Systems. Substations References

The Intelligent AX1 Switchgear for Medium Voltage

DR50 Hensim Dirt Runner 49cc Dirt Bike (VIN PREFIX LLCH or LUAH)

1/29/2008 DR125 / DR150. Baja Motorsports Inc. P.O. Box Phoenix, AZ Toll Free: PARTS AND PRICES ARE SUBJECT TO CHANGE 1 of 55

FILTRATION AMIAD PLASTIC FILTERS, SCREENS & DISCS

Engine Strobe light, 110V Strobe light, 220V Replacement bulb Compression gauge Dial indicator

Gas-Insulated Switchgear up to 300 kv, 63 ka, 4000 A Type 8DN9. Answers for energy.

Aprilia.no. RS Eng.6M

Rexroth. Spare parts list. Bosch Group. Part No.: R Designation: VERSTELLPUMPE A4V-125 HD

Rail Canvas, folding top Rear panel Stip in window, left dto. right

High-Voltage GIS yesterday - today - tomorrow

K&T Saw Shop or

Price Book - Section 20 Miscellaneous

DR125 and DR150 Hensim Dirt Runner 125cc and 150cc Dirt Bike (VIN PREFIX LLCH or LUAH)

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

CUTTER-CRUSHER RAMMER RC 22

MÁQUINAS AGRÍCOLAS JACTO S.A. EDITION

PARTS MANUAL EH12-2 ENGINE. Model. PUB-EP5713 Rev. 7/99

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

GROENEVELD AUTOMATIC GREASING SYSTEMS

Class 5 to 7 Truck and Bus Hydraulic Brake System

SPARE-PARTS BOOK BZ (SA) Model: TABLE OF CONTENTS. Chapter 1: Liftchassis. Chapter 2: Platforms. Chapter 3: Cylinders

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

SPARE-PARTS BOOK Z Model: TABLE OF CONTENTS. Chapter 4.3: Alu.platform, flat 30mm laser L. Chapter 5: Cylinders

Operating Instructions Parts List Manual Scissor Lift Pallet Truck

FANG 24T, 26T and 28T -EU

HYDRAULIC TABLE CART 500-LB.

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

K&T Saw Shop or

MERCEDES FIRST EDITION

Unit 24: Applications of Pneumatics and Hydraulics

Electro-Pneumatic Bus Door Control Mechanism

MAN - MERCEDES - BENZ

Hydraulic Power Brake (HPB) Catalog

Labotek Spare Partlist

K&T Saw Shop or

Illustrated Parts List

V&A PROCONTROL. Rotary Valve Actuators Pneumatic & Hydraulic On-Off / Control / ESD Double Acting Spring Return All Steel SIL 3

PVM Piston Pumps Service Manual

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR

PVH131/141 Variable Displacement Piston Pump - 11 Design

Takfan Machinery and Mould Co Ltd. Plug in Bushing. LV Monoblock. RMU Bushing. 4 Way CT Terminal.

Air Vantage 500 Kubota

From 72.5 kv up to 800 kv. High-Voltage Circuit Breakers.

Edge 28B. Simple. Clean. PARTS LIST KENT model: (1)

Spare part list. For information only, will not be exchanged when altered! Date. piece Brush holder 220V/240V assy 7

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Design and Modeling of Fluid Power Systems ME 597/ABE 591 Lecture 5

Contents. Description Page Description Page

Electro-Mechanical Landing Gear System. Landing Gear and Brakes

Proportional pressure regulators VPPE

Operating Instructions Hand pallet trucks HU Profi. Issue

C O N T E N T S 1 ABOUT THIS PARTS LIST... 2 ENGINE GROUP CONTENTS-FRAME GROUP

Piston Diagnosis A rough Guide

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Siemens Integrated Substation Condition Monitoring System. Circuit Breaker Monitoring

HYDRAULIC LIFT TABLE CART 2200-LB.

7.1. Part Lists. Hardware Insertion Machine. Instructions. Instructions

PET. Illustration Pos Part Number Description Remark Qty Model jack operating rod tool bag 1

SC351. Model: SC351 NIL. Part List US-English

REMAN ENGINES APPLICATION GUIDE

HYLA NST Cleaning System

Pallet Jack. OWNER S MANUAL Model MH1230. Important Safety Instructions Assembly Instructions Parts and Hardware Identification

Transcription:

Maintenance Philosophy Service High Voltage Products, Transmission GIS, January 2012 ELK 1, 2, 3

Gas Insulated Switchgear Maintenance Philosophy Maintenance Philosophy for GIS type ELK1, 2, 3 Criteria time based maintenance 20 years of operation for indoor application 10 years of operation for outdoor application Criteria condition based maintenance Maximum No of CO* operation is reached Maximum No of SCC* switch operation is reached Combination of No of CO* and SCC* Recommendation in diagnosis report December 3, 2013 Slide 2, 1HC0088391_E01_AA * Information is mentioned in operational manual CO: close-open operation SCC: short circuit breaking current

Maintenance Philosophy TBM & CBM Definition TBM definition The criteria for time-based maintenance are aging of material based on environmental conditions of installation CBM definition CBM is to maintain the correct equipment at the right time. With CBM you can exchange just the components or parts that have been subjected to the most wear over their many years of reliable operation The most efficient way for contributing to life time expansion is following maintenance strategy combined with product improvements and support services. December 3, 2013 Slide 3, 1HC0088391_E01_AA

Maintenance Philosophy TBM Time Based Maintenance time based maintenance Criteria 20 years of operation for indoor application 10 years of operation for outdoor application Replacement of: Dynamic Sealing Kit CB Dynamic Sealing Kit DS Dynamic Sealing Kit ES Dynamic Sealing Kit FAES Dynamic Sealing Kit contents: Replacement of dynamic stressed sealings Adsorber (filter) December 3, 2013 Slide 4, 1HC0088391_E01_AA

Maintenance Philosophy CBM Condition Based Maintenance condition based maintenance Criteria Maximum No of CO* operation is reached Maximum No of SCC* switch operation is reached Combination of No of CO* and SCC* Recommendation in diagnosis report Product Overhaul CB Overhaul DS Overhaul ES Overhaul FAES Overhaul Drive HMB, AHMA, HKA, SN Retrofit instead of overhaul December 3, 2013 Slide 5, 1HC0088391_E01_AA Overhaul contents: Replacement of dynamic stressed sealings Adsorber (filter) All contact parts which are affected during switching, mechanical wearing * Information is mentioned in operational manual

Maintenance Philosophy CBM Condition Based Maintenance condition based maintenance Criteria If the data are not available? Product Pilotoverhaul bay Pilotoverhaul CB Pilot Overhaul contents: Replacement of dynamic stressed sealings Absorber (filter) All contact parts which are affected during switching, mechanical wearing Laboratory analysis of material/contact parts with report document December 3, 2013 Slide 6, 1HC0088391_E01_AA

Service High Voltage Products, Transmission GIS, January 2012 SF 6 Gas Insulated Switchgear Maintenance of circuit-breaker ABB 03/12/2013 Slide 7

Maintenance of circuit-breaker When do you need to maintain? If max. life time of dynamic sealings has been reached >20 years for indoor application >10 years for outdoor application à Dynamic Sealing Kit If max. number of operation have been reached Max number of close-open operation (2 000 / 5 000 / 10 000 CO, exact figure is mentioned in operational manual) Max number of short circuit breaking current (10 / 15 / 20 times the max. breaking current, exact figure is mentioned in operational manual) Combination of close-open operations and short circuit breaking current à Overhaul December 3, 2013 Slide 8, 1HC0088391_E01_AA

Maintenance of circuit-breaker When do you need to maintain? If no information available about number of operations and number of short-circuit breaking current and the circuitbreaker is older 10 years à Diagnosis or Pilotoverhaul December 3, 2013 Slide 9, 1HC0088391_E01_AA

Maintenance of circuit-breaker Dynamic Sealing Kit scope of work 1. Linear movement bushing 2. Operating road 3. Support insulator 4. Current connection 5. Chamber insulator 6. Filter / Adsorber 7. Current connection De-commissioning of circuit-breaker includes gas quality check, gas leakage check, travel curve and dynamic resistance measurement Installation of Dynamic Sealing Kit Re-commissioning of circuit-breaker includes gas quality check, gas leakage check, travel curve and dynamic resistance measurement December 3, 2013 Slide 10, 1HC0088391_E01_AA

Maintenance of circuit-breaker Overhaul scope of work 1. Linear movement bushing 2. Operating road 3. Support insulator 4. Current connection 5. Chamber insulator 6. Filter / Adsorber 7. Current connection 8. Puffing cylinder 9. Diaphragm 10. Erosion finger, cylinder base, auxiliary nozzle, contact ring 11. nozzle 12. contact finger, finger retainer 13. fixed contact pin De-commissioning of circuit-breaker includes gas quality check, gas leakage check, travel curve and dynamic resistance measurement Installation of Overhaul Kit Re-commissioning of circuit-breaker includes gas quality check, gas leakage check, travel curve and dynamic resistance measurement December 3, 2013 Slide 11, 1HC0088391_E01_AA

Maintenance of circuit-breaker Pilotoverhaul scope of work 1. Linear movement bushing 2. Operating road 3. Support insulator 4. Current connection 5. Chamber insulator 6. Filter / Adsorber 7. Current connection 8. Puffing cylinder 9. Diaphragm 10. Erosion finger, cylinder base, auxiliary nozzle, contact ring 11. nozzle 12. contact finger, finger retainer 13. fixed contact pin De-commissioning of circuit-breaker includes gas quality check, gas leakage check, travel curve and dynamic resistance measurement Installation of Overhaul Kit Re-commissioning of circuit-breaker includes gas quality check, gas leakage check, travel curve and dynamic resistance measurement Laboratory investigation of contacts Detailed laboratory report Maintenance recommendation for the rest of circuit-breakers within the GIS December 3, 2013 Slide 12, 1HC0088391_E01_AA

Maintenance of circuit-breaker Advantages of planned maintenance Significant lifetime extension Reduced failure risk Cost effective solution (compared to unplanned activities) Minimized and planned outage time Maintain the value of the circuit-breaker Maximize switchgear performance Identify problems at an early stage, prior to escalation acquisition of background information for tailored maintenance activities through pilot overhaul December 3, 2013 Slide 13, 1HC0088391_E01_AA

Service High Voltage Products, Transmission GIS, January 2012 SF 6 Gas Insulated Switchgear Maintenance of disconnector switch ABB 03/12/2013 Slide 14

Maintenance of disconnector switch Allocation of disconnector switches within GIS December 3, 2013 Slide 15, 1HC0088391_E01_AA

Maintenance of disconnector switch Allocation of disconnector switches within GIS Disconnector operating mechanism (for 3 phases) Connecting rod Disconnector switches December 3, 2013 Slide 16, 1HC0088391_E01_AA

Maintenance of disconnector switch Types of disconnector switches Axial Disconnector TE Cross Disconnector TX Angle Disconnector TV TW December 3, 2013 Slide 17, 1HC0088391_E01_AA

Maintenance of disconnector switch Overview of disconnector switch disconnector operating mechanism disconnector switch circuit-breaker bushing December 3, 2013 Slide 18, 1HC0088391_E01_AA earthing switch

Maintenance of disconnector switch When do you need to maintain? If max. life time of dynamic sealings has been reached >20 years for indoor application >10 years for outdoor application à Dynamic Sealing Kit If max. number of operation have been reached Max number of close-open operation (2 000 / 5 000 CO, exact figure is mentioned in operational manual) Max number of bus transfer current switching (100 CO @1600A / <40A exact figure is mentioned in operational manual) à Overhaul December 3, 2013 Slide 19, 1HC0088391_E01_AA

Maintenance of disconnector switch Dynamic Sealing Kit scope of work De-commissioning of disconnector switch includes gas quality check, gas leakage check, motor current and running time measurement Installation of Dynamic Sealing Kit Re-commissioning of disconnector switch includes gas quality check, gas leakage check, motor current and running time measurement Seal strip Seal-ring O-ring December 3, 2013 Slide 20, 1HC0088391_E01_AA

Maintenance of disconnector switch Overhaul scope of work De-commissioning of disconnector switch includes gas quality check, gas leakage check, motor current and running time measurement Installation of Overhaul Kit Re-commissioning of disconnector switch includes gas quality check, gas leakage check, motor current and running time measurement Seal strip Contact tube support Seal-ring O-ring Fixed contact December 3, 2013 Slide 21, 1HC0088391_E01_AA

Maintenance of disconnector switch Pilotoverhaul scope of work De-commissioning of disconnector switch includes gas quality check, gas leakage check, motor current and running time measurement Installation of Overhaul Kit Re-commissioning of disconnector switch includes gas quality check, gas leakage check, motor current and running time measurement Laboratory investigation of contacts Detailed laboratory report Maintenance recommendation for the rest of disconnectors within the GIS Contact tube Seal strip support Seal-ring December 3, 2013 Slide 22, 1HC0088391_E01_AA O-ring Fixed contact

Service High Voltage Products, Transmission GIS, January 2012 SF 6 Gas Insulated Switchgear Maintenance of operating mechanism AHMA 4/8 ABB 03/12/2013 Slide 23

Maintenance of operating mechanism AHMA 4/8 Overview For overhaul the operating mechanism has to be removed from the circuit breaker Operating mechanism Circuit-breaker December 3, 2013 Slide 24, 1HC0088391_E01_AA

Maintenance of operating mechanism AHMA 4/8 When do you need to maintain? If max. life time of operating mechanism has been reached >20 years for indoor application >10 years for outdoor application à Overhaul If max. number of operation have been reached Max number of close-open operation (10 000 CO, exact figure is mentioned in operational manual) à Overhaul December 3, 2013 Slide 25, 1HC0088391_E01_AA

Maintenance of operating mechanism AHMA 4/8 Overhaul scope of work guide bush (711, 713) screw plug (251) check valve (301) change over valve USR16 (167) plug (40) locking screw (119) screw plug (49) connecting rod (o) working piston (o) guiding rod (o) pump motor (949) carbon brush (300) bevel wheel (11) dowel pin (103, 104) screw type coupling with protective cap (123) non return valve (7) filter (82) plug for locking device (253) December 3, 2013 Slide 26, 1HC0088391_E01_AA

Maintenance of operating mechanism AHMA 4/8 Overhaul scope of work Item Replaced Overhauled 7 non-return valve for pump 11 straight tooth bevel wheel 40 plug 49 screw plug 82 filter 103, 104 dowel pin 119 locking screw 123 screw type coupling with protective cap 167 change over valve 251 screw plug 253 plug for locking device 300 carbon brush for pump motor 301 check valve 711, 713 guide bush 800 sealings 949 pump motor working piston connecting rods guiding rod December 3, 2013 Slide 27, 1HC0088391_E01_AA

Maintenance of operating mechanism AHMA 4/8 Overhaul scope of work For outdoor application will be added following scope: position indicator window (28) O-ring seal for position indicator (112) screws, washers (135, 136) rubber seal (171, 1171, 1280) sealing for cover (281) December 3, 2013 Slide 28, 1HC0088391_E01_AA

Service High Voltage Products, Transmission GIS, January 2012 SF 6 Gas Insulated Switchgear Migration Modules ABB 03/12/2013 Slide 29

Retrofit Modules December 3, 2013 Slide 30

Retrofit Modules December 3, 2013 Slide 31

Retrofit Gascompartments December 3, 2013 Slide 32

Retrofit Bursting Disc December 3, 2013 Slide 33

Retrofit Disconnector December 3, 2013 Slide 34

Retrofit Disconnector December 3, 2013 Slide 35

Service High Voltage Products, Transmission GIS, January 2012 SF 6 Gas Insulated Switchgear Example - Maintenance Philosophy ABB 03/12/2013 Slide 36

Example Maintenance Philosophy Example Switchgear A Switchgear B year of installation: 1990 circuit breaker: 1900 no of CO circuit breaker: 3 no of SCC (breaking current unknown) disconnector switch: 500 CO earthing switches: 150 CO year of installation: 1995 circuit breaker: 2500 no of CO circuit breaker: 5 no of SCC (breaking current unknown) disconnector switch: 500 CO earthing switches 150 CO Process of data evaluation Collecting data from operational manual or on-site Application outdoor or indoor indoor Type of breaker SN 211 Max. no of close-open operation 5000 CO Max. no of short circuit current 15 / 50kA Max. no of operations for disconnector switch 2000 CO Max. no of operations for earthing switch 2000 CO December 3, 2013 Slide 37, 1HC0088391_E01_AA

Example Maintenance Philosophy Exemplary solution Switchgear A Circuit breaker: Dynamic Sealing Kit à age 21 years Circuit breaker drive: Overhaul à age 21 years Disconnector switch: Dynamic Sealing Kit à age 21 years Earthing switch: Dynamic Sealing Kit à age 21 years Fast acting earthing switch: Dynamic Sealing Kit à age 21 years Optional: Migration modules à improvements, if customers want it for next 25 years Switchgear B Circuit breaker: Overhaul à combination of CO & SCC Circuit breaker drive: Overhaul à together with CB Disconnector switch: Dynamic Sealing Kit à not required Earthing switch: Dynamic Sealing Kit à not required Fast acting earthing switch: Dynamic Sealing Kit à not required Optional: Migration modules à not required December 3, 2013 Slide 38, 1HC0088391_E01_AA