Devireg 530, 531, and 532 Installation Instructions INT

Similar documents
Installation Guide. DEVIreg 530. Electronic Thermostat.

Installation Instructions

GB/DAS User Instruction

DEVIreg 330 (+5 to +45 C)

Article: Version:

ACS-30-EU-EMDR-10-MOD

User Manual THR840DUK Digital Thermostat

Drayton Digistat +2RF/+3RF

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

, User s Manual

The original heating cable just got better

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Infrarot-Bewegungsmelder IP44

OPERATING INSTRUCTIONS

Single Channel Loop Detector

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

Passive Infrared Motion Detector 5420/90. Installation Instructions

Manual. Solar Fountain Mobile Phone Charger

MPA-101. WARNING: Improper installation could result in damage to the amplifier and/or speakers. Read all instructions before installation.

IO-RM3 3-Stage Relay Module

PS 155 WIRELESS INTERCOM USER MANUAL

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch

EC4.8. BalancedReferencePreamplifier. Owner smanual ENG

INSTALLER S & OWNER S MANUAL

TIG INVERTER INSTRUCTION MANUAL

MOTION SENSOR PIR LIGHT SWITCH INSTALLATION & OPERATING. Cat No. ZV810 INSTRUCTIONS

EN 3 ABSORPTION, READY TO USE ANALYSE BULK DESULPHATION SOFT START. L: 2000 mm MODE- BUTTON SUPPLY PLUG* SUPPLY

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

MXS 3. MANUAL FULLY CHARGED PULSE, MAINTENANCE CHARGING EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT CHARGE CABLE ERROR LAMP MODE- BUTTON

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

User s Manual Before using the inverter, you need to read and save the safety instructions.

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

MANUAL EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT ABSORPTION, READY TO USE ANALYSE FLOAT, FULLY CHARGED PULSE, MAINTENANCE CHARGING

MANUAL EN 3. Continue to press the MODE-button to combine charging program with charging options.

ELECTRIC CENTRAL HEATING FLOW BOILER

Operating instructions II / 2004

Product and functional description

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

TC-9102 Series Surface Mount Temperature Controllers

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Automatic Phone-Out Home Monitoring Systems

8146/5 Series Breaker Panelboards

EBDSPIR-PRM, EBDSPIR-PRM-IP

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

DALI RC BASIC SO. Control unit Operating instructions

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

AXIS PS12 Outdoor Power Supply. Installation Guide

HERZ-Thermal Actuators

FIRERAY 2000 Installation Guide

Fire Alarm Control Panel. Family. Operating Manual

Single Station Remote Alarm

CO2 Alarm. Operation. Application

Part I - Installation

Wireless 7 Day Programmable Room Thermostat

MULTI XS Battery charger. For lead-acid batteries 1,2-120Ah

Snow/Ice Melt Heating Cable System Gutters & Roof Drains Installation Manual Nexans TXLP/1 Series Resistance Cables

5W LED Energy Saver PIR Bulkhead

victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Advantium 2 Plus Alarm

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

H45 LED - Direct and indirect pendant

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Water Leak Detection System

USER S MANUAL HSC-24A

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

Motion Detector 360 Degrees 5420/360. Installation Instructions REGISTERED DESIGN REGISTERED PATENT


Operation and Installation Manual

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Freeze Protection Thermostats MODELS SST 2. Installation and Operation Manual

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

How To Read A Pipe From A Sensor

Indoor Remote Controlled Power Points

Product and Application Description

Inwall Room Temperature Unit

User s Manual AURORA 1.2K/2.2K

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor User Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

BroadBand PowerShield. User Manual

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG

How To Use A Power Supply Unit (Upu)

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

GAE953 Electrical Alarm Unit 19" with Indicator

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

WD-AMX Water Detection Controllers

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Transcription:

Devireg 530, 531, and 532 Installation Instructions INT

Contents Applications and Functions...3 Maximum floor temperature setting...4 Light indications (LED)...5 Installation instructions...6 Placement of Devireg 530, 531, and 532...7 Connection diagrams for Devireg 530, 531, and 532...8 Technical specifications for Devireg 530, 531, and 532...9 The DEVI Guarantee...10-11 The installation must only be carried out by an authorised electrician. 2

Table 1. Applications of content and Functions The Devireg 530 series is a line of electronic thermostats used for control of indoor heating. The Devireg 530 is used for control of floor heating installations. The thermostat is equipped with a floor sensor for control of the desired floor temperature. INT The Devireg 531 is used for control of room heating installations. The thermostat is equipped with a built-in air sensor for control of the desired room temperature. The Devireg 532 is used for room heating installations. The thermostat is equipped with a built-in room sensor and floor sensor. The room sensor is used for control of the room temperature. The floor sensor is used for maximum temperature limitation in wooden floors and other heat sensitive floors. The range of operation can be limited: Min. Max. 3

2. Maximum floor temperature setting Maximum floor temperature is preset at the factory to 35 C for cable temperature safety. Local building regulations must be observed when changing the maximum preset tempera ture. You can/must set the maximum floor tempera ture on the Devireg 532 by taking off the front cover and with a screwdriver adjust the sunken temperature dial in the top left hand corner between 20 to 50 C. Notice: The floor temperature is measured where the floor sensor is placed. The temperature of the bottom of a wooden floor can be up to 10 degrees higher than the top. Floor manufactures often specify the max. temperature on the surface of the floor. Please contact your floor supplier for maximum surface temperature. 4

3. Light indications (LED) The Devireg 530 series has a LED indicator above the 2 pole safety switch (see illustration). LED indicator 15 20 25 INT 30 35 devireg 550 The LED has four indications: No light means the system is off. Red light means system is heating. Green light means system is standing by. Flashing green light means there is a problem with the floor sensor (only applicable for 530 and 532). Call your electrician. Check connections, if they are OK, then disconnect the 2 sensor wires. Measure the ohm value and check with the values in the table in Technical Specifications. is used for setting the thermostat in frost protection mode, i.e. keeping the room/floor temperature (depending on type of thermostat) at approx. 5 C at any time. 5

15 20 25 35 30 4. Installation instructions When installing a thermostat from Devireg 530 series, you must first remove the front cover. To remove the front cover, gently press the release tabs under the bottom of the thermostat with a screwdriver. Then remove the front. You do not need to remove the set point dial. 6

5. Placement of Devireg 530, 531, and 532 Installation height, typically between 80-150 cm for Devireg 531/532 INT In wet rooms it should be installed on an even surface, according to local building regulations. At least 50 cm away from windows/doors that will be left open occasionally. Not on a wall where it will be subjected to direct sunlight. Not on the inner side of a wall facing the outside. 7

Configuration - Max. floor temp. Devireg 530 Type D530 N L N N LOAD Max.Load 15 A L L LOAD C T N NTC NC 5-45 C Devireg 531 Type D531 N L Max.Load 15 A NC NC NC N N LOAD L L LOAD NC = no connection 5-35 C Devireg 532 Type D532 N L N N LOAD Max.Load 15 A L L LOAD C T N NTC NC 20-50 C Temperature limiter NC = no connection 5-35 C 8

8. Technical specifications for Devireg 530, 531, and 532 Operation voltage 180-250 VAC, 50/60 Hz Standby consumption Max. 0.25W Relays: Resistive load Inductive load 230V ~ 15A/3450W cos φ = 0.3 Max. 4A Sensing unit NTC 15 kohm at 25 C Sensing values: 0 C 20 C 50 C 42 kohm 18 kohm 6 kohm Hysteresis +/- 0.4 C for 530 (528) +/- 0,2 for 531 + 32 Ambient temperature Frost protection 5 C Temperature range: 530 531 532 Sensor failure monitoring IP class 31 Dimensions -10 to +30 C 5-45 C 5-35 C 5-35 C, floor temperature limiter range: 20-50 C The thermostat has a built-in monitoring circuit, which will switch off the heating if the sensor is disconnected or shortcircuited. 85 mm x 85 mm INT 9

The 2 Year DEVI Warranty: You have purchased a DEVI heating system which we are sure will serve to improve the comfort and economy of your application. DEVI provides superior electrical heating solutions for total climate control in and around homes and buildings. DEVI offers a complete product program with Deviflex TM heating cables or Devimat TM heating mats, Devireg TM thermostats, Devifast TM fixing strips and Devi Self-limiting heating cables combined with additional products completing the product program. This 2 year warranty applies to all DEVI products. Should you, against all expectations, experience a problem with your DEVI product, you will find that DEVI offers a 2 year warranty from the date of purchase on the following conditions: During the warranty period DEVI shall offer a new comparable product or repair the product in case the product is found to be faulty by reason of defective design, materials or workmanship. Repair or replacement shall be carried out at DEVI s discretion. DEVI shall not be liable for any consequential or incidental damages including, but not limited to, damages to property or extra utility expenses. This warranty shall only be valid on production of proof of purchase and must be submitted to the installer or seller without undue delay. An extension of the warranty period following repairs undertaken under warranty cannot be granted. The DEVI Warranty shall not cover any damage caused by incorrect conditions of use, incorrect installation or if installation has been carried out by non-authorised electricians. All work will be invoiced in full if DEVI is required to inspect or repair faults that have arisen as a result of any of the above. The DEVI Warranty shall not extend to equipment which has not been paid in full. DEVI will, at all times, provide a rapid and effective response to all complaints and inquiries from our customers. The warranty explicitly excludes all claims exceeding the above conditions. 10

2 YEAR WARRANTY Warranty Certificate The DEVI TM Guarantee is granted to: Name: Address: City: Country: INT Telephone: Attention: The Warranty Certificate must be completed correctly for the Warranty to be valid. Please read the Warranty conditions on the previous page. Type of thermostat: Electrical installation by: Material number: Date: Suppliers Stamp Date / -: Suppliers Stamp Date / - 11

Article No.: 08095821 Version - 02.05 DEVI A/S Ulvehavevej 61 DK-7100 Vejle Tel: +45 74 88 85 00 Fax: +45 74 88 85 01 www.devi.com VICKH102 01/2008