Bringing colour to life. Shower Lining Detail

Similar documents
IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

Installation Instructions

Important Information

majestic install ation guide barcelona three sided enclosure 24mm surface mounted wall channels and underframe to base

Curved Quadrant Instruction Manual

Lustrolite Installation Guide

Window Installation Instructions

IMPORTANT INFORMATION

PANELIZED HOME INSTALLATION GUIDELINE

Clad Direct Glaze Window Installation Instructions

ILLUSION FRAMELESS SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

KITCHENS. Tip PAGE 1 FITTING YOUR KITCHEN GUIDE. How to mark out a kitchen. Tools required for installing a kitchen STEP ONE STEP TWO STEP THREE

Tested to BS 6375: Part 1: 1989 and achieved a weathertightness classification of 2000 Pa (Special)

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

How-To-build guide timber windows

CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS

How To Install Your Frameless Shower Enclosure

Barewood Octagon and Elongated Windows Installation Instructions

SAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the Denver. 12'x 12' or 12'x16' Revised November 29, 2010

Packaged Terminal Air Conditioner Wall Sleeve Installation

COASTLINE QUADRANT ENCLOSURE. Installation / Maintenance Instructions Rev

Eucaboard / Eucaplac/ Eucatile paneling is intended for dry interior use only and requires care in handling.

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

Installation Guide. Bath and Wall Surrounds SERIES B

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

IN00378 (rev A) Corner Entry

Can you design a frameless shower enclosure that doesn't leak?

The WANZ Guide to Window Installation

Wet Area Construction. Carpentry - Residential Construction. Product Code: 5603

Installation Instructions

Installation Instructions

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

QWALL 4 ACRYLIC SHOWER WALL INSTALLATION INSTRUCTIONS

Vinyl Greenhouse Window Page 2 of 6 New Contruction Installation Instructions

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

Beautifully Traditional

ISSUE 2. Installation Guide

Best Barns USA Assembly Book

Tundra Series Windows January 2016

7. Installation. installation CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME

6mm Two Door Offset Quadrant

Measure Guideline: Water Management at Tub and Shower Assemblies

All-Season Sunroom Sliding Glass Door Installation Instructions

AMERICAN GOTHIC PLAYHOUSE

DIY CABINET REFACING INSTALLATION GUIDE

WATERPROOFING OF WET ROOMS

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

Seismic Installation for Attic Storage System

Folding Bath Screen Instruction Manual

INSTALLATION OF A BAY WINDOW

Sun Windows General Information Sun New Construction Window Installation Instructions

Premier & Deluxe 3-Season Room Sliding Glass Door

BUTTERFLY SHOWER DOOR INSTALLATION INSTRUCTIONS

HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL

DE Frame with C Series Sidelight

Heavy Glass Frameless Shower Door With Return Panel

Bathroom Installation Guide

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin

AM/FM ANTENNA KIT (TOUR-PAK MOUNT)

Information Technology Solutions

Installing Window Trim and Door Trim

Installation Instructions

12.1 Schlüter -KERDI-BOARD

LK Wallbox UNI Push. Assembly. Only intended for LK PE-X Universal Pipe X.

Installation Instructions For Slider Casement Air Conditioners

March 14, Installation of Bay, Bow and Garden Windows

Installation instructions of the MIDI-Heki roof light with operating bar, with crank or electrical version

300mm. 2mm MIN GAP. PLACE 100mm X 100mm. SO THAT IT IS 38mm INTO

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING

INSTALLATION INSTRUCTIONS for Vinyl Windows without Nailing Fin (JII011) ImPOrTANT INFOrmATION & GlOssAry. rough OPeNINGs

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

FLAT ROOF CARPORT RECOMMENDED INSTRUCTION MANUAL

5800 Temperature Sensor Cable Assembly

T H A N K Y OU F O R Y OUR P U R C H A S E O F A N E S S E N T I A V A N I T Y, P L E A S E R E A D T H E S E V A N I T Y C A R E A N D I N S T A L L

How to Install GoBoard:

Important Information for Installer & Homeowner

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW

450 SERIES SLIDING GLASS DOOR ASSEMBLY AND INSTALLATION INSTRUCTIONS

1 Door Tall Unit ASSEMBLY GUIDE. Page 1 of 9. WARNING: Contains small parts, keep out of reach of children.

Integral Kit Instructions

Technical data sheet PVC Bi-fold doors

Black Wolf POCKET BILLIARD TABLE INSTALLATION MANUAL. SERVICE DEPARTMENT P.O. BOX 68 BRISTOL, WI 53104

POWER LOCK KIT GENERAL INSTALLATION -J04427 REV Kit Number. Models. Additional Parts Required. Kit Contents

AAMA Standard Practice for Installation of Windows with a Mounting Flange in Open Stud Frame Construction for Low Wind/Water Exposure

Skirt 1 / 4. The Skirt. The skirt patterns were downloaded from Mark's site but they need expanding before they can be used.

Wetroom Panel (Concealed Fix)

Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide


MGB Chrome Bumper Conversion

Standing Seam Roof Systems

FAQs. 19. Does the sub floor need to be level before I install my new direct-to-stud bathtub or shower base?

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Acrylic Walls Installation Instructions

REDI-EXIT COMMERCIAL FIRE DOOR AND EXTERIOR DOOR KITS INSTALLATION GUIDELINES

Installation Window Building In Details

Transcription:

Bringing colour to life Shower Lining Detail Distributed by Aquaknight Industries Ltd Phone 09 832 2214 www.endurapanel.co.nz January 2013

Sealing of Perimeters, Penetrations & Edges 50mm band of Sealer around perimeter and edges of penetrations 50mm band of Sealer around perimeter EnduraPanel It is important to protect the rear (coated) side of EnduraPanel from moisture with a band of neutral cure silicon or acrylic sealant extending 50mm from the edge of the panel. This should include: The perimeter of the sheet including any notches made Perimeter of any penetrations made i.e. shower mixer or shower slide-rail fixings The edges of these penetrations 2 January 2013 Distributed by Aquaknight Industries Ltd Phone 09 832 2214 www.endurapanel.co.nz

New Zealand Standard Practice Shower Tray Installation Stud EnduraPanel Fibre cement sheet Packer Bottom Plate Silicon Air Gap Acrylic Shower Tray Acrylic shower trays in New Zealand are commonly installed using the system detailed below. With attention to detail, this has proven to be a durable solution. Acrylic tray should be mounted up to the bottom plate of wall in accordance with the manufacturer s installation instructions. Wall lining such as fibre cement sheet should be laid against framing following manufacturer s instructions, down to within 6mm of shower tray. Flexible caulking should be installed between top of tray and bottom edge of wall lining in a continuous bead, then smoothed off as illustrated. EnduraPanel is then installed over the wall lining and over the up-stand lip of the tray, as illustrated above, with a bead of flexible caulking between; the back of EnduraPanel and front of tray up-stand lip, and the top of tray and bottom edge of EnduraPanel. A gap should be left between the two caulking beads to act as a capillary break. Distributed by Aquaknight Industries Ltd Phone 09 832 2214 www.endurapanel.co.nz January 2013 3

Sealing Detail - Weep Hole Sealing detail showing weep hole Left-hand EnduraPanel removed for clarity AFM Sealer EnduraPanel Internal Corner Jointer Fibre cement sheet EnduraPanel Caulking Bead 6mm weep hole Capillary Break Shower Tray 4 January 2013 Distributed by Aquaknight Industries Ltd Phone 09 832 2214 www.endurapanel.co.nz

Install Anti Fracture Membrane Anti-Fracture Membrane (AFM) 3 Sharp as possible corner 7 No Raduis in corner AFM Install a suitable anti-fracture membrane in the internal corner running from the finished installed height of the shower, down and over the lip of the tray, terminating at the bottom of the tray lip. There should be as small a radius as possible in the wall corner. Distributed by Aquaknight Industries Ltd Phone 09 832 2214 www.endurapanel.co.nz January 2013 5

Install Internal Corner Jointer Internal Corner Jointer Jointer AFM ALERT - Weep Hole refer to page 4 for Sealing Detail The internal corner jointer is an integral component in a shower installation, as this will accommodate thermal expansion that may be experienced during the showering cycle. The jointer should run the same length as the antifracture membrane i.e. from the finished installed height of the shower, down to the bottom of the shower tray lip. Cut the internal corner jointer to length Trim off 6mm of jointer as shown Install the internal corner jointer against the antifracture membrane 6 January 2013 Distributed by Aquaknight Industries Ltd Phone 09 832 2214 www.endurapanel.co.nz

Measure and Cut EnduraPanel Finished Width Measurement from outside of door receiver to 45deg edge +5mm Finished Height EnduraPanel shower liners are supplied as a standard kit. Measure the distance from the outside of the door, return to the edge of the 45 edge of the Internal Corner Jointer and add 5mm. This is the EnduraPanel finished width. Measure from the top of the door return to the top of the shower tray. This is the EnduraPanel finished height. ALERT - Weep Hole refer to page 4 for Sealing Detail Cut EnduraPanel in accordance with the instructions contained in the Machining of EnduraPanel technical specification. Cut any penetrations and notches into EnduraPanel. Distributed by Aquaknight Industries Ltd Phone 09 832 2214 www.endurapanel.co.nz January 2013 7

Apply Sealant and Adhesive to EnduraPanel Install EnduraPanel Sealant Adhesive approx 100mm apart Up to expansion lip Remove the protective film from rear of EnduraPanel. Seal the perimeter and all penetrations and penetration edges with a band of neutral cure silicon or acrylic sealant extending 50mm from the edge of the panel as illustrated, above. Apply adhesive to rear of EnduraPanel as shown in the illustration, above. Apply bead of flexible caulking to up-stand lip of tray. Apply three beads of flexible caulking along the full height of the corner: Onto the liner at the edge of the anti-fracture membrane Onto the anti-fracture membrane at the edge of the internal corner jointer Peel back protective film from front face of EnduraPanel, 25mm from the edge to be inserted into internal corner jointer. Fit EnduraPanel into Internal Corner Jointer, up to the expansion lip. Roll EnduraPanel onto wall. Smooth out surface of EnduraPanel with hands (do not excessively push EnduraPanel into the wall). Install second EnduraPanel following the previous steps. Onto the internal corner jointer in front of the expansion lip 8 January 2013 Distributed by Aquaknight Industries Ltd Phone 09 832 2214 www.endurapanel.co.nz

Fitting Door Returns: 1. Drilling Fitting Door Returns: 2. Fixing Clearance Drill min of 3 places Door Return EnduraPanel Clearance Hole for Selftapper Fibre cement sheet Framing DO NOT SCREW INTO EnduraPanel IT WILL SPLIT Peel back protective film from front face of EnduraPanel, to the width of door return + 25mm from the outer edge of EnduraPanel. Fit door returns in place ensuring they are in the correct position and plumb. Drill clearance holes through EnduraPanel and wall linings using the guidelines in Machining EnduraPanel. At least 3 fixing points should be used over the height of a 1.8m shower, 4 fixing points in a 2m shower. Remove all swarfe from holes, de-bur door return if necessary. Door Return EnduraPanel Screw bites into frame only Fibre cement sheet Framing DO NOT SCREW INTO EnduraPanel IT WILL SPLIT Fit door returns back in place. Fill holes with flexible caulking before screwing returns to the wall. Check for plumb and position before final tightening of door return fastenings. Distributed by Aquaknight Industries Ltd Phone 09 832 2214 www.endurapanel.co.nz January 2013 9

Fitting of Mixer Plate Sealing of EnduraPanel Top Edge Peel back protective film from front face of EnduraPanel, to 25mm beyond the outer edge of the shower mixer s installed perimeter. Apply a bead of flexible caulking around the perimeter and a second bead around the penetration in the EnduraPanel. In line with BRANZ recommendation, we suggest that silicon be applied to the top of EnduraPanel. This is to prevent any moisture penetrating down behind the lining. Special attention should be paid to the top of the internal corner jointer and anti-fracture membrane areas. See illustration, above. Both beads should be finished as shown above to allow for any moisture to drain away. Fix mixer plate as per manufacturer s instructions. 10 January 2013 Distributed by Aquaknight Industries Ltd Phone 09 832 2214 www.endurapanel.co.nz

Fit Shower Door Assemblies Fitting of Shower Sliders etc Fit shower door assemblies as per manufacturer s instructions. This step generally does not involve EnduraPanel. Items such as shower slider rails, shower caddies and soap dishes are generally installed last. Traditionally this involves further penetrations of EnduraPanel. Follow guidelines in Machining of EnduraPanel technical specification. Modern adhesive products including specialist glues and high performance double-sided tapes are acceptable for light loads with these items. Always follow manufacturer s instructions. EnduraPanel is classed as a methacrylate (MMA) for the purposes of specifying an adhesive substrate. Distributed by Aquaknight Industries Ltd Phone 09 832 2214 www.endurapanel.co.nz January 2013 11