OPTIMA Dry Lining System High Performing, Easy & Quick

Similar documents
Airtight Intelligence

Rockwool Flexi Insulation Application Guide

Manual lifting and handling

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Multi-layer Insulation Blanket for Roofs

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Section Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

Timber Frame Walls Rethinking Construction

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

Lightweight Partition Design for Residential and Commercial Buildings

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Rockwool Cladding Roll

12.1 Schlüter -KERDI-BOARD

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas

Built to Last. Built for Beauty. Good. Solid. Logix. TM

sound reduction systems for commercial, educational and industrial environments

Module 3.7. Thermal bridging

Underwriters Laboratories Testing Information

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

WALLS Three common wall types are described below, with their insulation solutions.

research highlight Highly Energy Efficient Building Envelope Retrofits for Houses

FIRE RATED GLAZING System Guide

Post-insulation of cellar ceiling and cellar walls

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

Mineral fibreglass insulation

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

Composite Panel Firewall Systems

2.18 INTERIOR & EXTERIOR FINISHES VAPOR & AIR BARRIERS

The Kingspan Insulation Price List 1 st January 2013

We care about. Environmentally-Friendly Building Products from Renewable Resources. natural building products. Product range overview

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

C05. S03. P02 P08 FireWall. Including C05. S01. P02 Specialist partitions introduction

Fire Barrier Duct Wrap 15A

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

Mold Preventing I nterior System

FIXIT.CH. Aerogel Insulating Plaster System. Handling Guidelines. Easy to use. Mineral based W/mK BAUSTOFFE MIT SYSTEM

The Warm Edge for insulating glass

IMPACT DAMAGE RESISTANT WALL SYSTEMS

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

Prefabricated building PVC vertical sliding window

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

plumbing products guide

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Advisers for real building

HEALTHY LIVING WITH WOOD FIBRE INSULATING MATERIALS

AND MEMBRANES ROOFING UNDERLAYS.

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors

Innovation #9/12. of all Formaldehyde for up to

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Guide to domestic building renovation. Telephone: Fax:

Foundation. Foundation

LAYING BLOCK AND BRICK

Moisture Content in Insulated Basement Walls

Energy Company Obligation (ECO): Technical Monitoring Questions

Rev Code of Practice. SIP Technology.

H-Stud Area Separation Wall System

2014 British Columbia Building Code Changes

The right solutions. However, it is inevitable that with the introduction of any new construction system the question arises How does it compare?

Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors.

Partitioning & Ceiling Product Information

Signs of insulation problems In the winter. In the summer. conditioning system

FireWall. High performance fireresistant. FireWall.

Sistema de Etiquetagem Energética de Produtos (SEEP) Energy Labeling System for Products

EcoTouch Insulation with PureFiber Technology

Roof Insulation Building. Energy. Environment friendly e-library

Conservatory warm roof conversion system

Cover: Houghton Estate, luxury residential estate This page: Protea Hotel, Umhlanga Ridge

PRODUCT GUIDE lower tolerances high quality

Article. Protecting the Building Envelope from Water Damage. MemBrain Smart Vapor Retarder & Air Barrier Film

Improving thermal insulation of concrete sandwich panel buildings

C09. S02. P02 P14 CasoLine mf. Including C09. S01. P02 P08 Sound absorbing solutions introduction

Double Coated Urethane Foam Tapes

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

Before You Start an Energy Efficiency Retrofit The Building Envelope

Choosing better, more energy efficient windows. A homeowners guide

Sealing & Bonding Sika solutions for Window Installation

Baumit Renders for Porotherm Masonry. Application Guidelines. n Light and easy application n Tried and tested

*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.

PB301 July Lightweight Building Solutions. Bushfire Protection.

Multi-Foil reflective insulation SPACE SAVING U-VALUE AS LOW AS 0.16W/m 2 K LIGHTWEIGHT EASY TO FIX

The Optimum Basement Wall

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Key energy-efficient features of your new home

Squash Court Design general points

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

European Organisation for Technical Approvals

HOW AN ENERGY EFFICIENT HOME CAN HELP THE ENVIRONMENT

Transcription:

OPTIMA Dry Lining System High Performing, Easy & Quick

CO2: The Problem CO2: 30 kg/m a 2 kg/m2a 2 Energy needs: 150 kwh/m a 2 Heating costs index price: Heating costs index price: 0@ Standard House @ Energy needs: 15 kwh/m2a A problem typical of older Irish houses Isover s Multi Comfort House Efficient High Energy Costs: Low Comfort Levels Highly inefficient 18% Efficient 82% Highly inefficient is ever-increasing heating costs without corresponding increases in temperature and comfort. Insulation was not a priority years ago and efficient thermal insulation materials were not readily available. We are all aware that today s building standards don t accept such inadequacy in insulation and in the future they will be even less tolerant. Modern techniques and products have been developed that eliminate drafts and ensure comfortable internal conditions. But what if you have an older home? Older houses are considerably less energy-efficient, wasting heat year-round through poorly insulated walls and rarely achieving sufficient warmth in the winter. That s why we ve developed OPTIMA. Fig 1: BER Cert Need to insulate external walls on the inside to retain heat control noise and draughts? 2 Fig 2: Energy performance of existing housing stock

The Solution The OPTIMA Dry Lining System from Isover What is OPTIMA? OPTIMA is the high performance solution for insulating new and older houses from the inside. Essentially, it s an innovative dry lining system developed by insulation specialists Isover to significantly improve thermal and sound insulation. Our insulation products are renowned for their quality and reliability. As the newest addition to the Isover family OPTIMA is designed specifically for homes where outer facade or wall cavity insulation is simply not a viable option. OPTIMA addresses this with an easy-to-install, cost-effective alternative for renovating and insulating external walls from the inside. Where to use OPTIMA? Residential Non Residential New and Old Why choose OPTIMA? There are several key features that make OPTIMA dry lining insulation system the perfect solution for interior thermal and acoustic insulation of walls: Perfect thermal and acoustic performance Eliminates thermal bridges Adjustable system addresses all wall types and issues Dry, clean, lightweight system with minimal waste, The solution is OPTIMA Dry Lining System enabling rapid construction times Optional airtightness & moisture control feature Economical 3

7 basic installation steps 1. Secure 2.4m C-channel @1.35m OPTIMA system I. Metal frame 1. OPTIMA Floor and ceiling U-channel 2. OPTIMA 500mm extension 3. OPTIMA 2.4m C-channel 4. OPTIMA Clip system: OPTIMA2 Support (for new walls) or OPTIMA Direct Support (70 160) (for renovation walls) II. Insulation 5. ISOVER insulation material, e.g. Standard Performance Comfort roll 35 (standard = 0.035W/mK) or Ultra Performance Comfort Panel 32 (Ultra = 0.032 W/mK) III. Air tightness & Moisture control layer (optional) 6. VARIO Protape (double sided) 7. VARIO KM Duplex UV air tightness & moisture control layer 8. VARIO KB1 one-sided adhesive tape 9. VARIO DS Mastic IV. Facing. Gyproc Plasterboard (various specifications of boards available) 1 2 3 4 5 6 7 8 2. Secure floor and ceiling U-channel 3. Fix plastic clip on horizontal C-channel 4. Hang insulation on plastic clips 5. Fix plastic clip on vertical C-channel, adjust until plumb and lock in place 6. Fix Vario and accessories 9 7. Fix Plasterboard 4 Refer to Installers manual for further details 5

OPTIMA System components explained I. Metal frame OPTIMA Metal frame light, solid, flexible The standard elements that make up the OPTIMA frame ensure the system is both mechanically stable and economical. The structure can be adapted to fit virtually every building type, regardless of any discrepencies in the existing wall surfaces. For the facing support, the OPTIMA C-channel (a 2.40m metal stud) together with OPTIMA 300 and 500 extension pieces can be used to extend or adjust to the required height. Fig 3: Plastic Clip Locking System Summary of benefits Avoids thermal bridges, as the insulation layer is continuous Precise, easy and practical installation and adjustment Plastic clip locking system ensures studs are firmly secured in position Time saving installation Fig 4: Height adjustable metal studs II. Insulation ISOVER insulation for OPTIMA of 2 grades: Comfort Roll 35 (standard λ = 0.035W/mK) or Comfort Panel 32 (higher performing λ = 0.032 W/mK) Summary of benefits Products with low thermal conductivity save space and increase thermal insulation performance Soft tissue faced for easy handling, with gridlines to aid installation Compressed products save space and time, both for transport and distribution on site A Fire rating and CE mark certified 6

III. Air tightness & Moisture control VARIO is Isover s solution to air tightness and protection against moisture. VARIO s unique quality is its ability to change its water vapour performance. The VARIO membrane adapts and reacts naturally, changing its permeability according to humidity conditions, allowing closed building systems to increase their drying potential. This means VARIO is truly multifunctional, acting as a barrier in winter and a breathable membrane in summer. IV. Facing Gyproc plasterboards are the modern way to provide high quality, high performance linings for today s buildings. Available in an unrivalled range of types and sizes. Choose from: Gyproc 8x2 s - The perfect solution for areas where space is tight. Comes with tapered edges for jointing and can be finished with Skimcoat plaster. IN SUMMER As the structure warms in summer, the membrane s micropores open, allowing vapour to escape into the building interior. IN WINTER In winter, the membrane prevents vapour from the warm interior diffusing into the structure. Summary of benefits Dual functionality humidity regulation: improved and faster drying out in summer, and secure barrier in winter Reliable functionality with matched components VARIO KM Duplex UV printed guidelines for easy accurate cutting Gyproc SoundBloc - For improved acoustic performance, to achieve a quieter environment. Gyproc Moisture Resistant - This Gypsum plasterboard has water repellent additives in its core and a special green paper liner. Perfect for bathrooms and kitchens. Gyproc Wallboard - The standard board for use in wall and ceiling applications where basic fire and acoustic performance levels are required. Summary of benefits Suitable for every design Quick assembly Smooth and level surface Wide choice of boards to suit specific performance requirements Gyproc Rigidur - Contains Gypsum, paper fibres and mineral additives, can support loads up to 55kg without grounds and is ideal for fixing kitchen units and TVs. 7

OPTIMA System - High level thermal performance 215mm Hollow Block 15mm external render 215mm Hollow block + insulation + Vario + Gyproc wall board Partial Fill Masonry Cavity Wall Insulation 15mm external render + 0mm block + 50mm cavity + 50mm foam (0.038) + 15mm external render + 0mm block + 13mm plaster + insulation + Vario + Gyproc wall board Concrete Wall 15mm external render + 200mm Concrete + 13mm internal plaster + insulation + Vario + Gyproc wall board Timber Frame Wall 0mm block + 50mm cavity + breather membrane + 12mm OSB + 150mm Metac (between studs) + insulation + Vario + Gyproc wall board Single Brick Construction 0mm brick + 13mm plaster + insulation + Vario + Gyproc wall board OPTIMA s impressive thermal insulation performance is clearly demonstrated by the following calculations. The table below indicates the insulation performance one can expect using the OPTIMA System with different types of wall construction. 0.27 W/m 2 K Current R.O.I. Building Regulation as of 20 0.20 W/m 2 K Isover recommends! Insulation U value W/m 2 K Total thickness of system (mm) 120mm Comfort 32 0.23 152.5 140mm Comfort 32* 0.20 172.5 120mm Comfort 35 0.24 152.5 140mm Comfort 35 0.21 172.5 160mm Comfort 35 0.19 192.5 180mm Comfort 35 0.17 212.5 *Isover recommends for better performance Insulation U value W/m 2 K Total thickness of system (mm) 60mm Comfort 32 0.26 92.5 120mm Comfort 32 0.18 152.5 140mm Comfort 32 0.16 172.5 60mm Comfort 35** 0.27 92.5 80mm Comfort 35 0.24 112.5 0mm Comfort 35 0.21 132.5 120mm Comfort 35* 0.19 152.5 *Isover recommends for better performance **Current Building Regulations Insulation U value W/m 2 K Total thickness of system (mm) 120mm Comfort 32 0.24 152.5 140mm Comfort 32* 0.20 172.5 120mm Comfort 35 0.26 152.5 140mm Comfort 35 0.23 172.5 180mm Comfort 35 0.18 212.5 *Isover recommends for better performance Insulation U value W/m 2 K Total thickness of system (mm) 60mm Comfort 32 0.19 92.5 60mm Comfort 35* 0.20 92.5 80mm Comfort 35 0.18 112.5 *Isover recommends for better performance Insulation U value W/m 2 K Total thickness of system (mm) 60mm comfort 32 0.44 92.5 120mm Comfort 32 0.24 152.5 140mm Comfort 32* 0.21 172.5 80mm Comfort 35 0.37 112.5 0mm Comfort 35 0.31 132.5 120mm Comfort 35 0.26 152.5 140mm Comfort 35 0.23 172.5 *Isover recommends for better performance **Northern Ireland Regulations as of 20 = 0.35 W/m2K 8

Acoustic performance Indoor acoustic comfort should be provided by the building envelope to protect against noises from outside and adjoining properties. When applied to existing wall constructions, the OPTIMA System can significantly increase the sound insulation performance of a building, providing an increased level of personal privacy in the home. The acoustic insulation of a construction in-situ is determined by the Apparent Weighted Sound Reduction Index: R w. This index is expressed in decibels (db), whereby the higher the R w value the better the sound insulation performance. Moisture control performance Ireland s high levels of humidity make it essential to ensure that no condensation risks can occur within the construction. Simulating The OPTIMA system on 215mm Aerated Concrete using WUFI*, we can see that moisture accumulation is not an issue due to the performance of the Vario vapour control membrane. The table below lists some examples of estimated R w values for common construction types in Ireland and the expected improvement following the installation of the OPTIMA system to one side. Base Construction 215mm solid blocks with 12.5mm sand/ cement render on both sides 200mm precast concrete 215mm concrete block Two leaves of 0mm dense concrete blocks with 0mm cavity Thickness of ISOVER glass wool with AFr 5 kpa.s/m 2 OPTIMA Lining In-situ Sound Insulation Performance, db R w Base Construction Base Construction + OPTIMA Gain in Sound Insulation Performance, db 50mm 63 9 0mm 12.5mm Plasterboard 54 64 160mm 65 11 50mm 64 9 0mm 12.5mm Plasterboard 55 65 160mm 66 11 50mm 65* 12 0mm 12.5mm Plasterboard 53 66* 13 160mm 67* 14 50mm 67* 9 0mm 12.5mm Plasterboard 58 68* 160mm 68* *This level of sound insulation performance is based on a construction comprising the described base construction only. Any compound elements to the overall construction, e.g. windows, doors etc., will result in a significant reduction in the overall performance. Fig 5: WUFI chart - without Vario layer >0 (mm/h) 1 0.1 0.01 Water Content (kg/m 3 ) 500 400 300 200 0 0 1.5 Mineral Plaster 21.5 Aerated Concrete Cross Section (cm) Moisture Accumulation *Mineral Wool 0 80 60 40 20 0 1.25 Gypsum Board Rel. Humidity (%) The example shown is a 3 year simulated model of a 215mm aerated concrete block that is insulated internally with worst case scenario conditions i.e. North orientated with a high internal moisture load. Without Vario, a moisture accumulation on the internal face of the concrete wall can be seen in Fig 5, however when Vario is introduced not only is the structure airtight but you are also protected from moisture Fig 6. *(WUFI-ORNL/IBP is a menu-driven PC program which allows realistic calculation of the transient coupled one-dimensional heat and moisture transport in multi-layer building components exposed to natural weather) Fig 6: WUFI chart - with Vario layer (mm/h) >0 1 0.1 0.01 Water Content (kg/m 3 ) 500 400 300 200 0 0 1.5 Mineral Plaster 21.5 Aerated Concrete Cross Section (cm) Vario ensures drying out of structure 0 80 60 40 20 0 0.1 1.25 *Mineral Wool Gypsum Board Vario KM Duplex Rel. Humidity (%) 9

Dealing with specific issues Picture 1 Integrating Services Standard electrical appliances, home automation and networking have led to an increase in cabling and ducting that need to be included in buildings (Picture 1). The OPTIMA System allows the integration of such networks in the lining without compromising insulation. The networks are run between Isover glass wool and plaster boards. VARIO Multitape SL is used to ensure breakout points are both vapour and air tight. Window Details The position of the windows has to be taken into account. Frame out window using C-channel above and below window as shown (Picture 2). The OPTIMA connector (Picture 3) is used to construct T-joints between OPTIMA vertical and perpendicular studs, for instance to accommodate a window frame (Picture 4). Picture 2 Picture 3 Picture 4 Cornering Details An OPTIMA Floor and Ceiling U-channel can be used for corner detailing (Picture 5 and 6). Picture 5 Picture 6

OPTIMA System - production specification ISOVER Insulation Material Isocomfort 35 Roll with λ = 0,035 W/mK R m2.k/w Thickness (mm) Length (m) Width (m) 5.14 180 2300 1200 4.57 160 2600 1200 4.00 140 3400 1200 3.43 120 3900 1200 2.86 0 4500 1200 2.29 80 5300 1200 1.71 60 7000 1200 Isocomfort Panel 32 with λ = 0,032 W/mK R m2.k/w Thickness (mm) Length (m) Width (m) 4.38 140 1200 600 3.75 120 1200 600 1.88 60 1200 600 Insulation Cutter Double edge knife for cutting the insulation material. The Accessories OPTIMA No. 5200425735 OPTIMA Floor and ceiling U-channel length: 2.35m Pallet of 12 bundles of 20 units = 564 m OPTIMA Support 75 50 pieces No. 5200425740 OPTIMA C-channel Length: 2.4m Pallet of 40 bundles of units = 960 m OPTIMA Support 0 OPTIMA Support 120 50 pieces 50 pieces OPTIMA 300mm extension Pallet of 40 bundles of units = 120 m OPTIMA Support 140 50 pieces No. 5200425741 OPTIMA 500mm extension Pallet of 40 bundles of units = 200 m Optima Direct Support (70 160) No. 5200537462 40 pieces OPTIMA Connector 25 pieces Vario Vario KM Duplex UV 5200300299 Length - Width 40 m 1.5 m 60 m2/ roll Vario DS Mastic 5200300295 Length - Width 3 ml 12 pieces Vario KB1 Single sided tape 5200300297 Length - Width 40 m 60 mm 5 rolls = 200 m Vario Multi tape SL 52004317 Length - Width 25 m 60 mm rolls = 250 m Vario Protape 5200300296 Length - Width m 25 mm 5 rolls = 50 m 11

Isover Ireland 505 Grants Drive Greenogue Business Park Rathcoole Co. Dublin Tel +353 (0) 1 2575400 Fax +353 (0) 1 4019793 Email info@isover.ie Web www.isover.ie OPTIMA System - sample calculation (5m of wall) What you would need to install the OPTIMA System on five metres of wall? OPTIMA Floor and ceiling U-channel OPTIMA 2.4m C-channel OPTIMA 500mm Extension piece OPTIMA Clip system ISOVER Insulation material eg Comfort panel 120mm Vario DS mastic 5 lengths lengths 8 pieces pieces 13.5m 2 2 cartridges of 3ml Isover Glasswool Insulation Vario KM Duplex UV 15m 2 Vario KB1 5.2m Optima Lightweight Components Gyproc Plasterboard This sample table gives an indication of the materials needed based on a wall height of 2.7 m and spacing of vertical studs at 600 mm centres. SpecSure is a unique off the shelf life time warranty To qualify for SpecSure simply specify and install the Optima system in conjunction with Gyproc plasterboards in line with the recommendations in both current Product Manuals. (Gyproc Product Manual & Isover Optima Installers Guide) About ISOVER: ISOVER is committed to comfortable living and climate protection. We believe in developing products to create a better, more comfortable world. Already, ISOVER insulation warms and protects 1 in 3 homes in Europe and 1 in 5 in America. Our products save you energy and money; but they also come with a proven environmental pedigree. As Europe s leading producers of high-performance insulation materials, we strive every day to develop increasingly efficient and resource-saving products. We know our responsibility to the earth and continually innovate to deliver the best products to our customers.