1 C09. S0. P0 P Including C09. S0. P0 P08 Sound absorbing solutions introduction

2 C09 Sound absorbing solutions Introduction Sound absorbing solutions This section details sound absorbing solutions which both provide reverberation control and improved aesthetics

3 Sound absorbing solutions British Gypsum sound absorbing solutions, incorporating Gyptone, Rigitone, Gyprex and Eurocoustic tiles, boards and planks, combine exciting aesthetic design with excellent acoustic absorption performance. With performance levels up to Class A sound absorption, our ceilings meet the demands of industry standards in sectors such as education, healthcare and residential, making them ideal for schools, high-rise multi-occupancy buildings, healthcare buildings as well as offices and retail premises. Our quick reference sound absorbing solutions guide, below, allows you to understand the key benefits of each solution, including grid concealment and flange size. Further detail can be found within the subsequent sections to help further refine your choice. Description System Page A suspended ceiling system, that can be used in conjunction with Gyptone and Rigitone ceiling boards to create a seamless, monolithic appearance. Concealed suspended ceiling system for constructing curved ceilings. A concealed ceiling system with minimal cavity depth suitable for a wide range of installations, and utilising the same components as GypLyner universal wall lining solution. A demountable, exposed mm wide grid ceiling system compatible with a range of Gyprex, Gyptone and Eurocoustic tiles. A demountable, exposed mm wide grid ceiling system compatible with a range of Gyprex, Gyptone and Eurocoustic tiles. CasoLine curve GypLyner universal CasoLine quick-lock grid t CasoLine quick-lock grid t C09. S0. P0 C09. S0. P0 C09. S0. P0 C09. S0. P0 C09. S0. P0 Introduction Sound absorbing solutions C09 A demountable, fully concealed grid ceiling system compatible with a range of Gyptone tiles. The ideal ceiling solution for spanning between corridor walls, unsuspended up to.m incorporating Gyptone Planks. CasoLine quick-lock grid d CasoLine quick-lock Corridor Systems C09. S07. P0 C09. S08. P0 0 9 bgtechnical.enquiries@bpb.com C09. S0. P0

4 C09 Sound absorbing solutions Introduction Sound absorbing solutions Areas to consider when specifying Acoustics A suspended ceiling can provide two levels of acoustic performance; sound insulation, preventing the passage of sound into the room from an external source, and sound absorption, which is the control of undesirable sound within the room, in the form of reverberation. Ceiling systems incorporating products such as Gyproc SoundBloc provide the greatest level of sound insulation, while the Gyptone, Rigitone or Eurocoustic ranges provide excellent sound absorption performance for reverberation control. Aesthetics The ceiling provides a large blank canvas which can form part of the overall interior design scheme. Patterns, colours and shape can all be easily incorporated using products such as Gyptone or Rigitone. A lower key, minimalist appearance can be achieved with the clean, white finish of Gyprex or Eurocoustic systems. Air quality Historically, the role of a suspended ceiling has been limited to passive performance in terms of aesthetics, acoustics and fire resistance. With our VOC-absorbing ACTIVair technology now available as standard in all Gyptone and Rigitone products, the ceiling can now take on a more active functional role within the room. It actively improves the indoor air quality and provides the associated benefits to the occupants in the space below. Refer to C0. S0. P9 Indoor air quality. Accessibility Whatever type of ceiling is designed (table ), access to the cavity above the ceiling will inevitably be required. whether this is for inspection, maintenance or repair of HVAC and similar services. A seamless system such as can accommodate access points in the form of Profilex or Gyptone access hatches, whilst lay-in grid ceilings have the advantage of allowing access at virtually any point across the ceiling. Table Ceiling system combinations Demountable systems Gyprex tiles T T D Types of ceiling Demountable A traditional demountable ceiling consists of individual ceiling tiles which are laid into a metal grid. More recent innovations of the traditional lay-in grid ceiling include the CasoLine quick-lock-grid d concealed, and the CasoLine quick-lock-grid Corridor System. The plank system can be used to provide totally clear, unobstructed access to M&E services in commercial buildings. Lay-in ceilings are generally simple to install, easy to maintain and can be dismantled, repositioned or even reused. Seamless Systems such as or GypLyner universal ceilings provide a smooth, seamless monolithic ceiling. These types of ceiling can be used to achieve high levels of sound insulation, absorption, or both. These systems provide a large degree of flexibility and can be installed horizontally, sloped, vertically or - using CasoLine curve - giving a contoured shape. Cleanability Commercial ceilings are subject to a diverse range of cleaning regimes. A typical sports hall, for example, may require little or no cleaning during its working life. A hospital ceiling, on the other hand, needs to cope with the frequent and/or aggressive cleaning regimes required in clinical areas. Ceiling systems such as Gyprex bio provide a wipeable vinyl surface with an integral biocide, preventing the growth of fungi and bacteria, including MRSA, E. coli O7 and Salmonella. Additional Information Our Gyptone range offers the highest level of accessibility to the ceiling cavity. Gyptone Hatch, Gyptone Plank and the Gyptone TRAP system are ideally suited to where regular or unrestricted access to the cavity is required and can be used either as a stand-alone solution or in conjunction with another Gyptone ceiling. For full details of these products and suitable systems, please refer to the British Gypsum Ceilings Installation Guide, available to download from british-gypsum.com. Seamless systems Plank GypLyner CasoLine curve Eurocoustic tiles Gyptone Tiles Gyptone Plank Gyptone board Rigitone board C09. S0. P0 british-gypsum.com

5 Gyptone performance Table Sound absorption data for Gyptone boards QUATTRO QUATTRO QUATTRO Sound absorption coefficient α p C0A09 Sound absorption coefficient α p C0A0 Sound absorption coefficient α p Gyptone quattro (plenum depth 87mm) 0 00 k k k α W AC NRC C 0.70 Gyptone quattro (plenum depth 0mm) 0 00 k k k α W AC NRC D 0. Gyptone quattro (plenum depth 00mm) Gyptone quattro (plenum depth 00mm plus 00mm Isover Spacesaver Ready-Cut) 0 00 k k k α W AC NRC (L) D Introduction Sound absorbing solutions C0A0 C0A (L) D 0. C09 AC Absorption Class. NRC Noise Reduction Coefficient. Due to installation limitations the minimum cavity size that can be constructed with or CasoLine curve system is 00mm. The sound absorption performance for these systems is estimated to be equivalent to that of the same system built with a 0mm plenum. All products have been tested to BS EN 0 and ISO. The single figure rating practical sound absorption coefficient α w is calculated in accordance with EN ISO. Suffix letters indicate where performance is limited at either low, medium or high frequencies. 0 9 bgtechnical.enquiries@bpb.com C09. S0. P0

6 C09 Sound absorbing solutions Introduction Gyptone performance (continued) Table (continued) Sound absorption data for Gyptone boards QUATTRO 7 LINE SIXTO Sound absorption coefficient α p Sound absorption coefficient α p C0A0 C0A C0A00 C0A00 Sound absorption coefficient α p C0A Gyptone quattro 7 (plenum depth 00mm) Gyptone quattro 7 (plenum depth 00mm plus 0mm Isover Acoustic Partition Roll (APR 00)) 0 00 k k k α W AC NRC (L) D 0. (L) D 0. Gyptone line (plenum depth 00mm) Gyptone line (plenum depth 00mm plus 00mm Isover Spacesaver Ready-Cut) 0 00 k k k α W AC NRC (L) D (L) D Gyptone sixto (plenum depth 00mm) 0 00 k k k α W AC NRC C 0 AC Absorption Class. NRC Noise Reduction Coefficient. All products have been tested to BS EN 0 and ISO. The single figure rating practical sound absorption coefficient α w is calculated in accordance with EN ISO. Suffix letters indicate where performance is limited at either low, medium or high frequencies. C09. S0. P0 british-gypsum.com

7 Rigitone performance Table Sound absorption data for Rigitone boards 8--0 SUPER Sound absorption coefficient α p C0A08 C0A09 C0A09 8/8 Sound absorption coefficient α p /8 Q Sound absorption coefficient α p C0A0 C0A07 C0A Rigitone 8--0 super (plenum depth 0mm) Rigitone 8--0 super (plenum depth 00mm) Rigitone 8--0 super (plenum depth 00mm plus 0mm Isover Frame Batt ) 0 00 k k k α W AC NRC (M) D (LM) D (LM) D 0.70 Rigitone 8/8 (plenum depth 0mm) Rigitone 8/8 (plenum depth 00mm) Rigitone 8/8 (plenum depth 00mm plus 0mm Isover Frame Batt ) 0 00 k k k α W AC NRC 0. (M) D (LM) D (LM) C Rigitone 8/8 q (plenum depth 0mm) Rigitone 8/8 q (plenum depth 00mm) Rigitone 8/8 q (plenum depth 00mm plus mm Isover Acoustic Partition Roll (APR 00)) 0 00 k k k α W AC NRC (M) D 0 Introduction Sound absorbing solutions C0A C0A C0A C B 0 C09 AC Absorption Class. NRC Noise Reduction Coefficient. Due to installation limitations the minimum cavity size that can be constructed with or CasoLine curve system is 00mm. The sound absorption performance for these systems is estimated to be equivalent to that of the same system built with a 0mm plenum. All products have been tested to BS EN 0 and ISO. The single figure rating practical sound absorption coefficient α w is calculated in accordance with EN ISO. Suffix letters indicate where performance is limited at either low, medium or high frequencies. 0 9 bgtechnical.enquiries@bpb.com C09. S0. P0

8 C09 Sound absorbing solutions Introduction Rigitone performance (continued) Table (continued) - Sound absorption data for Rigitone boards 0/ -0/ / Sound absorption coefficient α p Sound absorption coefficient α p C0A08 C0A09 C0A Sound absorption coefficient α p C0A0 C0A0 C0A C0A7 C0A9 C0A8 Rigitone 0/ (plenum depth 0mm) Rigitone 0/ (plenum depth 00mm) Rigitone 0/ (plenum depth 00mm plus 0mm Isover Frame Batt ) 0 00 k k k α W AC NRC (M) D (LM) D (LM) C 0 Rigitone -0/ (plenum depth 0mm) Rigitone -0/ (plenum depth 00mm) Rigitone -0/ (plenum depth 00mm plus 0mm Isover Frame Batt ) 0 00 k k k α W AC NRC (M) D (LM) D (LM) C 0.90 Rigitone / (plenum depth 0mm) Rigitone / (plenum depth 00mm) Rigitone / (plenum depth 00mm plus 0mm Isover Frame Batt ) 0 00 k k k α W AC NRC 0. 0.(M) D (LM) D (LM) C AC Absorption Class. NRC Noise Reduction Coefficient. Due to installation limitations the minimum cavity size that can be constructed with or CasoLine curve system is 00mm. The sound absorption performance for these systems is estimated to be equivalent to that of the same system built with a 0mm plenum. All products have been tested to BS EN 0 and ISO. The single figure rating practical sound absorption coefficient α w is calculated in accordance with EN ISO. Suffix letters indicate where performance is limited at either low, medium or high frequencies. C09. S0. P07 british-gypsum.com

9 Rigitone performance (continued) Table (continued) - Sound absorption data for Rigitone boards / Q Sound absorption coefficient α p AC Absorption Class. /0 Sound absorption coefficient α p C0A C0A0 C0A C0A00 C0A0 C0A0 Rigitone / q (plenum depth 0mm) Rigitone / q (plenum depth 00mm) Rigitone / q (plenum depth 00mm plus 0mm Isover Frame Batt ) NRC Noise Reduction Coefficient. Due to installation limitations the minimum cavity size that can be constructed with or CasoLine curve system is 00mm. The sound absorption performance for these systems is estimated to be equivalent to that of the same system built with a 0mm plenum k k k α W AC NRC (M) C (LM) C (L) B 0.90 Rigitone /0 (plenum depth 0mm) Rigitone /0 (plenum depth 00mm) Rigitone /0 (plenum depth 00mm plus 0mm Isover Frame Batt ) 0 00 k k k α W AC NRC (M) D (LM) D (LM) C All products have been tested to BS EN 0 and ISO. The single figure rating practical sound absorption coefficient α w is calculated in accordance with EN ISO. Suffix letters indicate where performance is limited at either low, medium or high frequencies. Introduction Sound absorbing solutions C bgtechnical.enquiries@bpb.com C09. S0. P08

10 C09 Sound absorbing solutions Concealed monolithic metal frame suspended ceiling system All our systems are covered by SpecSure when using genuine British Gypsum and Saint-Gobain Isover products

11 is a suspended ceiling system suitable for most internal drylining applications. The fully concealed grid and ceiling lining can be used in conjunction with Gyproc plasterboards and Gyptone and Rigitone acoustic ceiling boards to create a seamless, monolithic appearance. Key benefits High level of design flexibility; bulkheads, gradients and changes in height can all be fully integrated Services inspection and access points are easily included during design or installation Adaptable metal framing system fully compatible with a wide range of British Gypsum lining solutions to achieve a variety of performances tailored to meet individual project requirements Partition heights can be reduced as the partition channel can be supported by the ceiling framework rather than the soffit 0. α w Refer to C0. S0. P9 Refer to C0. S0. P07 Sound absorbing solutions C09 You may also be interested in... To achieve fire performances up to 0 minute airborne and impact sound insulation performances. Refer to C0. S0. P0 Floors and ceilings,. 0 9 bgtechnical.enquiries@bpb.com C09. S0. P0

12 C09 Sound absorbing solutions design Building design comprises Gypframe MF7 Primary Support Channels and Gypframe MF Ceiling Sections which forms a suspended frame to which Gyproc, Gyptone, Rigitone and Glasroc boards can be fixed. Planning key factors The depth of the ceiling cavity is a minimum 00mm. Relative humidity ceilings lined with Gyproc, Gyptone, Rigitone or Glasroc specialist boards are suitable for use under normal occupancy conditions. Buildings in which they are used should be dry, glazed and enclosed, with environmental conditions of no greater than 70% RH at 0 C to 0 C. For high humidity / high moisture conditions use Gyproc plasterboard mr variants or Glasroc F multiboard. Refer to C0. S0. P0 Robustness. Acoustic performance Gyptone and Rigitone boards are perforated and designed to provide sound absorption when used in conjunction with an airspace behind the ceiling. Increased levels of sound absorption can be achieved by including insulation over the back of the ceiling. Where sound insulation room-to-room is required, sound attenuation D n,c,w of 9dB can be achieved by the inclusion of 00mm Isover Spacesaver Ready-Cut over the back of the ceiling. Alternatively, other design considerations should be adopted such as extending adjoining partitions into the plenum void or installing a plenum barrier. Refer to C09. S0. P0 Sound absorbing solutions introduction, tables and. Thermal performance Isover insulation can be laid over the suspension grid to provide the required standard of thermal insulation. Contact the British Gypsum Technical Advice Centre for further guidance. Ceiling lift Changes to Building Regulations Approved Document L, airtightness requirements within dwellings, can lead to greater changes in air pressure when a door is opened. The ceiling is normally the lightest fixed element in the room, and therefore most likely to be affected by this change in pressure. This can cause the ceiling to lift, which may create a noise. Whilst this noise can be annoying to the occupier, it has no detrimental effect on the performance of the ceiling. The designer should consider incorporating a pressure release system to minimise the risk of ceiling lift. Where sufficient pressure relief cannot be designed in, it is recommended that the Gypframe MF Ceiling Section and the Gypframe MF7 Primary Support Channel should be screw-fixed together using two British Gypsum Wafer Head Jack-Point Screws at each intersection, particularly where non-perforated board linings are specified. Imposed loads Tables and provide loading data for the suspension grid for Gyproc, Glasroc specialist, Gyptone and Rigitone boards respectively. Maximum loads will be reduced by % when Gypframe FEA Steel Angle is fixed directly to the soffit (modified loads are shown in brackets). Table Maximum recommended loads on with Gyproc or Gyptone board linings Maximum load including weight of board, any insulation and finish plaster MF at 00mm centres kg/m (modified load) Suspension point centres mm MF7 channel centres mm (9) Gypframe MF Ceiling Section. Gypframe MF7 Primary Support Channel. Only applies to ceilings that have no fire resistance or acoustic insulation performance and single layer mm board. Table Maximum recommended loads on with Rigitone board linings Maximum load including weight of board, any insulation and finish plaster MF at 0mm centres kg/m (modified load) Suspension point centres mm MF7 channel centres mm 0 () Gypframe MF Ceiling Section. Gypframe MF7 Primary Support Channel. Suspension Gyproc, Glasroc specialist and Gyptone board linings Fixing points for suspending the metal grid are required at 00mm centres in each direction. Suitable fixing devices should be employed when fixing to the structure. The ceiling grid can be suspended from a concrete soffit using Gypframe MF Soffit Cleats and Gypframe MF8 Strap Hanger, or alternatively, Gypframe FEA Steel Angle. The latter provides a more robust suspension support, which restricts any flexing of the lining when pressure is applied from below. Gypframe FEA Steel Angle is therefore the preferred suspension option when a plaster finish is specified to Gyproc boards. If Gypframe FEA Steel Angle is used, it is recommended that it is fixed to the soffit via Gypframe MF Soffit Cleats. For single board solutions only, Gypframe FEA Steel Angle can be used to fix direct to the soffit. The angle should be cut along the spine with both flanges bent over. However, this will reduce the maximum loads that the grid is capable of supporting by %. Fixing Gypframe FEA Steel Angles direct is also not suitable if the ceiling is likely to deflect due to varying pressures and is not suitable for fixing to a sloping substrate. C09. S0. P0 british-gypsum.com

13 design (continued) Suspension Rigitone board linings Gypframe MF7 Primary Support Channels are fixed at 000mm centres. Fixing points to the structure for the Gypframe MF7 Primary Support Channels are required at 900mm centres. In addition to this, the Gypframe MF Ceiling Section should be installed at nominal 0mm centres. Refer to British Gypsum Ceilings Installation Guide for full details. Partition to suspended ceiling junction Where a GypWall metal stud partition is fixed to the framework of a ceiling, in accordance with British Gypsum s installation instructions, its permissible maximum height is equal to that of where it is fixed direct to a structural soffit of the same height. In situations where a GypWall metal stud partition passes through a ceiling, which is to both sides of the partition and appropriately fixed to both this partition and perimeter partitions / walls, consideration can be given to the lateral restraint provided by the ceiling when developing the partition specification. The relevant maximum height is the greater of the floor to ceiling or ceiling to structural soffit height. Care should be taken during installation of tall partitions so as to not adversely affect their performance. Contact the British Gypsum Technical Advice Centre for further guidance. Services The plenum can be used to route all service requirements including ducting, pipework, electrical cables and conduit. Where light fittings, access panels and similar components are incorporated as part of the design requirements, consideration must be given to maintaining the integrity of the ceiling to meet fire resistance and sound insulation requirements. Refer to tables or for maximum recommended loads. Fixtures Fixings to the system should always be made into the metal grid or to supplementary framing. Some adjustment of the primary grid may be required to support heavier fixtures, refer to tables and. Where loads outside this range are anticipated, independent suspension should be provided from the structure. Control joints Gyproc Control Joints may be required in the ceiling to relieve stresses induced by expansion and contraction of the structure. It is recommended that they coincide with movement joints within the surrounding structure. Rigitone expansion joints Rigitone boards should be cut 0mm short of the perimeter wall and should not be fixed to the perimeter channel. Refer to construction details 9-0. Board finishing Refer to C08. S0. P0 Jointing. Additional care and attention should be exercised when jointing Gyptone and Rigitone boards so as not to fill the perforations and impair the acoustic performance of the finished ceiling. Refer to British Gypsum Ceilings Installation Guide for full details. SpecSure All our systems are covered by SpecSure when using genuine British Gypsum and Saint-Gobain Isover products. Sound absorbing solutions C bgtechnical.enquiries@bpb.com C09. S0. P0

14 C09 Sound absorbing solutions construction details Max. 00mm Max. 0mm Perimeter parallel to Gypframe MF Ceiling Section - screw-fixed 8 7 Max. 00mm Max. 0mm Max. 00mm Perimeter perpendicular to Gypframe MF Ceiling Section - screw-fixed Max. 0mm Max. 00mm Max. 0mm Bulkhead - screw-fixed Change of level - screw-fixed Gyproc plasterboard or Glasroc specialist board Gypframe MF Ceiling Section Gypframe MF Perimeter Channel Gypframe MF7 Primary Support Channel Gypframe MF8 Strap Hanger or Gypframe FEA Steel Angle British Gypsum Wafer Head Jack-Point Screw 7 Gypframe MF Nut and Bolt 8 Gypframe MF Soffit Cleat C09. S0. P0 british-gypsum.com

15 construction details (continued) Sound absorbing solutions C09 Secondary double ceiling Gyproc plasterboard or Glasroc specialist board Gypframe MF Ceiling Section Gypframe MF Perimeter Channel Gypframe MF7 Primary Support Channel Gypframe MF8 Strap Hanger or Gypframe FEA Steel Angle British Gypsum Wafer Head Jack-Point Screw 7 Gypframe MF Nut and Bolt 8 Gypframe FEA Steel Angle 9 Gyptone or Rigitone board 0 9 bgtechnical.enquiries@bpb.com C09. S0. P0

16 C09 Sound absorbing solutions construction details (continued) Max. 00mm Max. 00mm Perimeter parallel to Gypframe MF Ceiling Section - Gyptone 8 7 Max. 00mm Perimeter perpendicular to Gypframe MF Ceiling Section - Gyptone Reflected ceiling plan - Gyptone Gyptone boards Gypframe MF Ceiling Section Gypframe MF Perimeter Channel Gypframe MF7 Primary Support Channel Gypframe MF8 Strap Hanger or Gypframe FEA Steel Angle Gypframe MF9 Connecting Clip C09. S0. P07 british-gypsum.com

17 construction details (continued) 9 Max. 0mm 7 Max. 0mm Perimeter parallel to Gypframe MF Ceiling Section - Rigitone 0 Max. 00mm 7 Perimeter perpendicular to Gypframe MF Ceiling Section - Rigitone Sound absorbing solutions C09 Reflected ceiling plan - Rigitone Rigitone boards Gypframe MF Ceiling Section Gypframe MF Perimeter Channel Gypframe MF7 Primary Support Channel Gypframe MF8 Strap Hanger or Gypframe FEA Steel Angle Gypframe MF9 Connecting Clip 7 Rigitone Vario 0 filler A special procedure is used for fixing and jointing Rigitone boards. Detailed installation notes are given in the current British Gypsum Ceilings Installation Guide, available to download from british-gypsum.com 0 9 bgtechnical.enquiries@bpb.com C09. S0. P08

18 C09 Sound absorbing solutions construction details (continued) Access panel installation Gyptone Access Hatch installation Gyproc plasterboard or Glasroc specialist board Gypframe MF Ceiling Section Gypframe MF Perimeter Channel Gypframe MF7 Primary Support Channel Gypframe MF8 Strap Hanger or Gypframe FEA Steel Angle Gypframe MF Soffit Cleat with MF Nut and Bolt 7 Gypframe MF Ceiling Section with ends tabbed and fixed 8 Gyptone Access Hatch (0 x 0mm) with frame (00 x 00mm) 9 Access panel (by others) 0 Gyptone board C09. S0. P09 british-gypsum.com

19 system components Gypframe metal components ( Board products ( Refer to C0. S0. P0 for details) Gypframe MF Perimeter Channel Perimeter section to support Gypframe MF Ceiling Section and fixing of board. Gypframe MF7 Primary Support Channel Primary section to support Gypframe MF Ceiling Section. Gypframe MF Ceiling Section Designed to provide seamless suspended ceilings and secondary section to support fixing of board. Gypframe MF8 Strap Hanger Alternative suspension of ceiling grid, typically metre maximum drop. Gypframe FEA Steel Angle Steel angle providing framing stability and board support. Preferred rigid hanger suspension of ceiling grid. Refer to C0. S0. P0 for details) Gyproc WallBoard Standard gypsum plasterboard. Gyproc FireLine Gypsum plasterboard with fire resistant additives. Gyproc SoundBloc Gypsum plasterboard with a high density core for enhanced sound insulation performance. Gypframe MF9 Connecting Clips Alternative method of connecting Gypframe MF Ceiling Section to Gypframe MF7 Primary Support Channel used in non-pressurised rooms. Gypframe MF Soffit Cleat Suspension point, one leg connected to structural soffit and the other leg connected to suspension hanger Gypframe FEA Steel Angle or Gypframe MF8 Strap Hanger recommended for all double and triple boarded solutions. Gypframe MF Nut & Bolt For connecting suspension hanger (Gypframe FEA or MF8) to Gypframe MF Soffit Cleat recommended for all double and triple boarded solutions. Gypframe GAH (mm) or GAH (70mm) Acoustic Hanger Suspension point for enhanced acoustic performance to timber floors. Gyproc DuraLine Gypsum plasterboard with fire resistant additives and a high density core for enhanced sound insulation and impact resistance performance. Gyproc Plank Standard gypsum plasterboard located as an inner layer. Glasroc F multiboard Non-combustible glass-reinforced gypsum board. Sound absorbing solutions Ceiling boards A full range of Gyptone and Rigitone boards are available to meet specific aesthetic and/or acoustic requirements. C09 Refer to C0. S08. P0 Also available in duplex grades where vapour control is required. Also available with ACTIVair technology. ACTIVair technology as standard. Also available in Moisture Resistant (mr) version. mr boards are specified in intermittent wet use areas. 0 9 bgtechnical.enquiries@bpb.com C09. S0. P0

20 C09 Sound absorbing solutions system components (continued) Fixing products ( Refer to C0. S0. P0 for details) British Gypsum Drywall Screws Corrosion resistant self-tapping steel screws for fixing board to metal framing less than mm thick. British Gypsum Collated Drywall Screws Corrosion resistant self-tapping steel screws for fixing board to metal framing less than mm thick. British Gypsum Wafer Head Drywall Screws Corrosion resistant self-tapping steel screws for fixing metal to metal framing less than mm thick. Plasterboard accessories ( Refer to C0. S0. P0 for details) Gyproc Jointing Material Jointing compounds, ready mixes and adhesives for reinforcement and finishing of board joints. Primers and sealers for treatment of boards for pre-decoration. Gyproc Control Joint To accommodate structural movement of up to 7mm. Gyproc edge and angle beads Protecting and enhancing board edges and corners. Finishing products ( Refer to C0. S0. P0 for details) Thistle MultiFinish To provide a plaster skim finish on Gyproc plasterboards. Thistle PureFinish To provide a plaster skim finish with ACTIVair technology. To provide a plaster skim finish on Gyproc plasterboards. Thistle ProTape FT0 Self-adhesive 8mm wide glass fibre mesh tape. British Gypsum Wafer Head Jack-Point Screws Corrosion resistant self-tapping steel screws for fixing metal to metal framing mm thick and greater. Rigitone Screws Specifically designed for fixing Rigitone board to metal framing. Gyproc Sealant Used to seal air paths for optimum sound insulation. Gyproc Drywall Primer A general purpose plasterboard primer, providing an ideal surface for decoration for most paints and wall coverings. Gyproc Joint Tape A paper tape designed for reinforcement of flat joints or internal angles. Thistle BoardFinish To provide a plaster skim finish to Gyproc plasterboards. Plaster accessories Designed for the reinforcement and finishing of board joints before plaster skimming. Thistle ProTape FT00 Self-adhesive 00mm wide glass fibre mesh tape. C09. S0. P british-gypsum.com

21 system components (continued) Ceiling products ( Refer to C0. S08. P0 for details) Gyptone quattro Acoustic board with square perforations capable of providing Class C sound absorption. Gyptone quattro Acoustic board with square perforations capable of providing Class D sound absorption. Gyptone sixto Gyptone board with a unique hexagonal perforated pattern capable of providing Class C absorption. Rigitone 8/8 q Acoustic board with a perforated pattern of 8mm squares capable of providing up to Class B absorption. Rigitone / q Acoustic board with a perforated pattern of mm squares capable of providing up to Class B absorption. Rigitone 0/ Acoustic board with a perforated pattern of 0mm circles capable of providing up to Class C absorption. Rigitone 8--0 super Acoustic board with a random pattern of 8mm, mm and 0mm circles capable of providing up to Class D absorption. Rigitone Spacing Tool Spacer tool used to ensure accurate installation of Rigitone boards. Rigitone Large Jointing Kit Jointing kit for application of Vario 0 into Rigitone boards. Gyptone quattro 7 Acoustic board with occasional square perforations and Class D absorption. Gyptone line Gyptone board with a linear perforated pattern capable of providing Class D absorption. Gyptone quattro Acoustic board with intermittent square perforations capable of providing Class D absorption. Rigitone -0/ Acoustic board with a perforated pattern of mm and 0mm circles capable of providing up to Class C absorption. Rigitone / Acoustic board with a perforated pattern of mm circles capable of providing up to Class C absorption. Rigitone /0 Acoustic board with a perforated pattern of mm circles capable of providing up to Class C absorption. Rigitone 8/8 Acoustic board with a perforated pattern of 8mm circles capable of providing up to Class C absorption. Rigitone Vario 0 Jointing Material High-strength jointing material used for jointing of Rigitone boards. Sound absorbing solutions C09 ACTIVair technology as standard. 0 9 bgtechnical.enquiries@bpb.com C09. S0. P

22 C09 Sound absorbing solutions system components (continued) Ceiling products (continued) ( Refer to C0. S08. P0 for details) Gyptone quattro Access Hatch Access hatch for providing access points in Gyptone quattro board ceilings. Gyptone quattro 7 Access Hatch Access hatch for providing access points in Gyptone quattro 7 board ceilings. Gyptone sixto Access Hatch Access hatch for providing access points in Gyptone sixto board ceilings. Access pannels ( Refer to profilex.co.uk for details) Profilex Access Panel Panel for access to cavity. Insulation products ( Refer to C0. S09. P0 for details) Isover Acoustic Partition Roll (APR 00) Glass mineral wool for enhanced acoustic performance. Isover Frame Batts Glass mineral wool for improved acoustic performance. Isover Spacesaver Ready-Cut Glass mineral wool for enhanced acoustic and thermal performance. ACTIVair technology as standard. Gyptone line Access Hatch Access hatch for providing access points in Gyptone line board ceilings. Gyptone quattro Access Hatch Access hatch for providing access points in Gyptone quattro board ceilings. Gyptone quattro Access Hatch Access hatch for providing access points in Gyptone quattro board ceilings. Isover Sound Deadening Floor Slab Glass mineral wool for enhanced acoustic performance. Stone Mineral Wool (by others) (kg/m or 00kg/m ) For fire performance. C09. S0. P british-gypsum.com

23 installation overview This is intended to be a basic description of how the system is built. For detailed installation guidance refer to the British Gypsum Ceiling Installation Guide. Gypframe MF Perimeter Channels are fixed Gypframe FEA Steel Angle or to the perimeter walls at 00mm centres. Gypframe MF8 Strap Hanger is secured to Gypframe MF Soffit Cleats with Gypframe MF Nuts and Bolts to form hangers. Gypframe MF7 Primary Support Channels Gypframe MF Ceiling Sections are fixed to are fixed to the hangers with the underside of the Gypframe MF7 Primary British Gypsum Wafer Head Jack-Point Support Channels to form a grid with Screws, two per hanger. British Gypsum Wafer Head Jack-Point Screws. Gyproc plasterboards, Glasroc specialist boards, Gyptone boards or Rigitone boards are then screw fixed to the Gypframe MF Ceiling Sections and Gypframe MF Perimeter Channels with British Gypsum Drywall Screws. These hangers are then suitably fixed to the soffit at the required centres. Alternatively, in areas not prone to ceiling lift, Gypframe MF9 Connecting Clips. Sound absorbing solutions C09 Additional information For full installation details, refer to the British Gypsum Ceiling Installation Guide, available to download from british-gypsum.com 0 9 bgtechnical.enquiries@bpb.com C09. S0. P

C05. S03. P02 P08 FireWall. Including C05. S01. P02 Specialist partitions introduction

C05. S03. P02 P08 FireWall. Including C05. S01. P02 Specialist partitions introduction C05. S03. P02 P08 Including C05. S01. P02 Specialist partitions introduction C05 Specialist partitions Introduction Specialist partitions This section details specialist lightweight systems where high-security,

More information

FireWall. High performance fireresistant. FireWall. www.british-gypsum.com

FireWall. High performance fireresistant. FireWall. www.british-gypsum.com FireWall FireWall High performance fireresistant wall system FireWall is a non-loadbearing wall which provides up to 240 minutes fire resistance. It is used in certain ground floor basement situations

More information

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available. APR 1200 Acoustic Partition Roll CI/Sfb Ref: APR002 Glass mineral wool roll designed to provide high levels of sound insulation in walls and floors to meet Part E (England & Wales) and Section 5 (Scotland)

More information

Manual lifting and handling

Manual lifting and handling Manual lifting and handling When installing British Gypsum products and systems care should be taken to ensure that appropriate methods of handling and lifting are adopted. The following guidance details

More information

Glasroc F multiboard Five high performances in one board

Glasroc F multiboard Five high performances in one board Glasroc F multiboard Five high performances in one board Glasroc F multiboard is non-combustible and depending on which of the three thickness you use can give you up to 120 minutes fire resistance. Great

More information

CasoLine QUICK-LOCK grid systems

CasoLine QUICK-LOCK grid systems CasoLine QUICK-LOCK grid systems CasoLine QUICK-LOCK T grid 90-0mm up to 000-00mm Tile edge details swg CasoLine QUICK-LOCK T/8 000mm CasoLine QUICK-LOCK T/8 600mm A Gyprex / Gyptone CasoLine QUICK-LOCK

More information

Finishing guide. For Thistle plaster and Gyproc plasterboard. Telephone: 08705 456123 Fax: 08705 456356 Email: bgtechnical.enquiries@bpb.

Finishing guide. For Thistle plaster and Gyproc plasterboard. Telephone: 08705 456123 Fax: 08705 456356 Email: bgtechnical.enquiries@bpb. BUSINESS SUPERBRAND SINCE 008 Gyproc, Thistle, Gypframe and Glasroc are all registered trade names of BPB United Kingdom Limited. Isover is a registered trade name of Saint-Gobain. Proprietor: BPB United

More information

Guide to domestic building renovation. Telephone: 0844 800 1991 Fax: 0844 561 8816 Email: bgtechnical.enquiries@bpb.com

Guide to domestic building renovation. Telephone: 0844 800 1991 Fax: 0844 561 8816 Email: bgtechnical.enquiries@bpb.com BRITISH GYPSUM A BUSINESS SUPERBRAND SINCE 2008 Gyproc, Thistle, Gypframe and Glasroc are all registered trade names of BPB United Kingdom Limited. Isover is a registered trade name of Saint-Gobain. Proprietor:

More information

British Gypsum Guide to Timber Frame Construction. March 1998

British Gypsum Guide to Timber Frame Construction. March 1998 British Gypsum Guide to Timber Frame Construction March 1998 Timber frame construction has a centuries long tradition in the UK, however, over the last 80 years it has continuously evolved to meet the

More information

sound reduction systems for commercial, educational and industrial environments

sound reduction systems for commercial, educational and industrial environments sound reduction systems for commercial, educational and industrial environments Tel: +44 ()14 3874 Fax: +44 ()14 38957 E-mail: info@soundreduction.co.uk Web: www.soundreduction.co.uk soundblocker Acoustic

More information

Partitioning & Ceiling Product Information

Partitioning & Ceiling Product Information Partitioning & Ceiling Product Information tel + 44 (0) 1384 412448 fax + 44 (0) 1384 4494 email enquiries@drywallsteelsections.co.uk web www.drywallsteelsections.co.uk tel + 44 (0) 1384 412448 fax + 44

More information

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap Tile Backing Will not deteriorate in water Easy to score and snap Resistant to mould and mildew Knauf Aquapanel Interior Cement board for wet areas Knauf Aquapanel Interior Cement Board Drywall for Wet

More information

PART 1 GENERAL 1.1 SECTION INCLUDES

PART 1 GENERAL 1.1 SECTION INCLUDES J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including

More information

Rockwool Flexi Insulation Application Guide

Rockwool Flexi Insulation Application Guide Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed

More information

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01. Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice

More information

Ecophon Focus A. System range. Size, mm. XL 2000x600. XL 1800x600. XL 2400x600 T15 T24 Thickness (THK) Inst. Diagr. 1200x600 1200x1200 1600x600

Ecophon Focus A. System range. Size, mm. XL 2000x600. XL 1800x600. XL 2400x600 T15 T24 Thickness (THK) Inst. Diagr. 1200x600 1200x1200 1600x600 Ecophon Focus A For applications where a robust suspended ceiling system is required. Ecophon Focus A has an exposed grid system. Each tile is easily demountable. The systems consist of Ecophon Focus A

More information

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with Section Separating Floors Timber frame floor with I-Beams Product: Earthwool Acoustic Roll and Floorfoam Easy Edge Strip Timber frame floor with solid timber joists Product: Earthwool Acoustic Roll and

More information

Ecophon Focus Ds. System range. XL 1800x600. Size, mm. XL 2400x600 T24 Thickness (THK) XL 2000x600. 1200x600 1200x1200 1600x600 M206, M208, M238

Ecophon Focus Ds. System range. XL 1800x600. Size, mm. XL 2400x600 T24 Thickness (THK) XL 2000x600. 1200x600 1200x1200 1600x600 M206, M208, M238 Ecophon Focus Ds For applications where a suspended ceiling with a concealed grid is required, but individual tiles must be easily demountable. Ecophon Focus Ds has a concealed grid and syetrical edge

More information

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details D Installation Details D1 General D2 Walls D3 Ceilings D4 Reference D Installation Details D Contents D1 General Installation and Fastening Sequence for Steel Studs D1.1 Fastener Selection D1.3 D2 Walls

More information

OWAplan1. The seamless acoustic ceiling. Pure acoustics. Pure design.

OWAplan1. The seamless acoustic ceiling. Pure acoustics. Pure design. OWAplan1 The seamless acoustic ceiling. Pure acoustics. Pure design. 3 Perspectives of freedom OWAplan It is time for a new way of thinking, for a new kind of freedom in room design, for taking a different

More information

PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ceilings & Floors

PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ceilings & Floors PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ceilings & Floors For distribution in Asia Pacific PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ceilings & Floors Contents

More information

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY PERFORMANCE CEILINGS M ore s c op e f or i n n ovat i on AMF Line; wall absorbers Wall mounted acoustic designs MADE IN GERMANY 138568_Prospekt Wandabsorber_GB int.indd 1 Acoustic elements on the wall

More information

Energy Company Obligation (ECO): Technical Monitoring Questions

Energy Company Obligation (ECO): Technical Monitoring Questions Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified

More information

NATIONAL INSTITUTE OF BIOLOGICALS

NATIONAL INSTITUTE OF BIOLOGICALS Short Term Notice Inviting Quotations Quotations No. S.1-36/07/NIB/Engg. (Civil) Invitation to short term quotations for Repairing of damaged gypsum board false ceiling and painting with epoxy paint in

More information

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight

More information

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01 Section Built-up Metal Roofs Rail and bracket system Product: Earthwool FactoryClad range Bu01 Standing seam system Product: Earthwool FactoryClad range and Earthwool Universal Slab Bu02 Built-up Metal

More information

VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD

VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board, vapor retarder and air and moisture barrrier. 1.2 RELATED WORK A. Installation

More information

Fiberglas, Exterior Wall Thermal Insulation

Fiberglas, Exterior Wall Thermal Insulation PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.

More information

Cover: Houghton Estate, luxury residential estate This page: Protea Hotel, Umhlanga Ridge

Cover: Houghton Estate, luxury residential estate This page: Protea Hotel, Umhlanga Ridge For Walls 1 Cover: Houghton Estate, luxury residential estate This page: Protea Hotel, Umhlanga Ridge Mass per m 2 CTN BPN Overview Description Gyproc RhinoBoard is manufactured according to the ISO 9001

More information

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing Schluter -KERDI-BOARD The universal substrate for tiles Flat. Level. Plumb. Square. No matter the quality, cost, or extravagance of

More information

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork HVAC - Fire protection of metal ductwork Fire protection Thermal insulation Isover ULTIMATE TM Protect - Fire protection

More information

Acoustic. Publication date June 2011. www.polymaxinsulation.com.au

Acoustic. Publication date June 2011. www.polymaxinsulation.com.au Acoustic Design Gui de Publication date June 2011 Contents Insulation Acoustic Design Guide Quick Product Selector Guide p.1 Introduction p.2 Acoustic Product Descriptions p.2 Sound Transmission p.3 Residential

More information

CEILING SYSTEMS. CI/SfB (35) Xy April 2006. [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design

CEILING SYSTEMS. CI/SfB (35) Xy April 2006. [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design CEILING SYSTEMS [Between us, ideas become reality.] CI/SfB (35) Xy April 2006 ULTIMA CANOPY Data sheet Acoustic performance meets High Design ULTIMA CANOPY Installation Instructions I. GENERAL 1. Product

More information

Acoustic Design Practices for Sustainable Buildings

Acoustic Design Practices for Sustainable Buildings Acoustics 2008 Geelong, Victoria, Australia 24 to 26 November 2008 Acoustics and Sustainability: How should acoustics adapt to meet future demands? Acoustic Design Practices for Sustainable Buildings Danny

More information

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST 0 RIVERSIDE DRIVE, OTTAWA, ON A0.0 COVER SHEET / DRAWING LIST A0. LEGEND AND GENERAL NOTES A0. GENERAL NOTES A0. GENERAL NOTES A0. TYPICAL WASHROOM WALL/SINK SECTION A0. DETAIL - CONTROL JOINT A0. DETAIL

More information

Innovation #9/12. of all Formaldehyde for up to

Innovation #9/12. of all Formaldehyde for up to Innovation #9/12 of all Formaldehyde for up to Gyproc Activ Air Benefits of Activ Air Improves the indoor air quality, providing healthier interior environments Permanently reduces Formaldehyde and other

More information

March 14, 2007. Installation of Bay, Bow and Garden Windows

March 14, 2007. Installation of Bay, Bow and Garden Windows March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed

More information

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas Powerpanel H 2 O is a cement based board from FERMACELL. Board Characteristics Board Thickness 12.5 mm Board Sizes 1000 x 1200 mm 50 sheets/pallet

More information

Section 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

Section 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining Section Timber Frame Walls Single layer between studs Product: Earthwool FrameTherm Rolls and Slabs Tf01 Single layer between studs with service void Product: Earthwool FrameTherm Rolls and Slabs Tf02

More information

Gypsum Board Systems Manual

Gypsum Board Systems Manual CertainTeed Gypsum Board Systems Manual Fire Resistance and Sound Control Design Manual Division 09 GYPSUM BOARD SYSTEMS MANUAL TABLE OF CONTENTS Introduction General Fire Resistance...1 Sound Control...3

More information

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS

More information

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.) Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.) Gyproc Plasters The cracks in cement sand plaster are an inherent feature which cannot be completely prevented but can only be controlled and

More information

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS NOISE TECHNICAL FACT SHEET FACT SHEET 5 SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS The sound insulation of exterior walls and roof-ceiling systems refers to their ability to reduce external

More information

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Services Enclosures and Protected Shafts - Maintaining Compartmentation Introduction When a fire resisting element is used to provide fire compartmentation, every opening that allows services to pass through the element must be adequately protected by sealing, or fire stopping

More information

CertainTeed. Shaftliner For A rea Separation Firewalls

CertainTeed. Shaftliner For A rea Separation Firewalls CertainTeed Shaftliner For A rea Separation Firewalls M2Tech Shaftliner Type X for Area Separation M2Tech Shaftliner is a specially formulated product for applications where enhanced mold resistance is

More information

Post and Beam Construction

Post and Beam Construction Post and Beam Construction A Presentation By the Canadian Wood Council Canadian Conseil Wood canadien Council du bois Early settlers introduced the concept of post and beam construction in North America

More information

Guide Specifications for Maple Flooring Systems

Guide Specifications for Maple Flooring Systems Guide Specifications for Maple Flooring Systems MFMA Guide Specification for Resilient Pre-Engineered Fixed Panel System Purpose This Guide Specification is designed to assist in the production of actual

More information

Lightweight Partition Design for Residential and Commercial Buildings

Lightweight Partition Design for Residential and Commercial Buildings Lightweight Partition Design for Residential and Commercial Buildings Stanley D. Gatland II, CertainTeed Corporation, Valley Forge, Pennsylvania Guidelines are presented for the design and proper installation

More information

Composite Panel Firewall Systems

Composite Panel Firewall Systems Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.

More information

Ceilings without fi ller. VoglFuge / VoglJoint. Acoustic design ceilings

Ceilings without fi ller. VoglFuge / VoglJoint. Acoustic design ceilings Technical information VoglFuge / VoglJoint Ceilings without fi ller With air purification as standard Create perfect acoustic designer ceilings with the VoglFuge / VoglJoint system Perforation patterns

More information

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in REV 1-12.12.11/TB002 Technical Bulletin Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in conjunction with TRADA Technology and is intended to provide the reader with introductory

More information

PB301 July 2009. Lightweight Building Solutions. Bushfire Protection. www.boral.com.au/bushfireprotection

PB301 July 2009. Lightweight Building Solutions. Bushfire Protection. www.boral.com.au/bushfireprotection PB301 July 2009 Lightweight Building Solutions Bushfire Protection www.boral.com.au/bushfireprotection Attached or adjacent within 6m roofed structures such as garages, carports, verandas and the like,

More information

ACOUSTICS. Axiom Canopy Clouds Absorption Data Sabines (average 500, 1k, 2k, 4k Hz) ACOUSTICS TESTING DATA Sound Absorption in Sabines

ACOUSTICS. Axiom Canopy Clouds Absorption Data Sabines (average 500, 1k, 2k, 4k Hz) ACOUSTICS TESTING DATA Sound Absorption in Sabines ACOUSTICS ACOUSTICS TESTING DATA Sound Absorption in Sabines SABINE DEFINITION A Sabine is a measure of the sound absorption provided by a material when installed within an architectural space. The number

More information

Controlling the Transmission of Impact Sound through Floors

Controlling the Transmission of Impact Sound through Floors Construction Technology Update No. 35 Controlling the Transmission of Impact Sound through Floors by A.C.C. Warnock This Update presents guidelines for controlling the transmission of impact sound through

More information

The White Book Refurbishment Guide Effective ways to repair, maintain and improve buildings.

The White Book Refurbishment Guide Effective ways to repair, maintain and improve buildings. The White Book Refurbishment Guide Effective ways to repair, maintain and improve buildings. Welcome to the first edition of The White Book Refurbishment Guide. Within this guide we have compiled an overview

More information

BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping.

BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping. BOQ SPECIFICATIONS VERTICAL BLINDS Vertical Blinds made of glass fibre fabrics in width 5 (or 4 ). Minimum overlapping of ¾ in fabric. Top aluminium anodized rail of 1.4 mm thickness. 2 inch wide channel

More information

FIRE RATED GLAZING System Guide

FIRE RATED GLAZING System Guide SYSTEM GUIDE Issue date: 05-05-2015 Expiry date: 31-12-2016 System Guide Introduction Pyropanel Developments are specialists in fire rated glazing solutions, and our systems are designed for easy installation

More information

EcoTouch Insulation with PureFiber Technology

EcoTouch Insulation with PureFiber Technology PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.

More information

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.

More information

Concepts. Products. Service. From one source. Plafotherm Plasterboard Heated and Chilled Ceilings

Concepts. Products. Service. From one source. Plafotherm Plasterboard Heated and Chilled Ceilings Concepts Products Service From one source. Plafotherm Plasterboard Heated and Chilled Ceilings 1 Building new solutions. Lindner undertakes major projects worldwide in all areas of interior fit-out, insulation

More information

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,

More information

Hanson Building Products. precast basement solutions

Hanson Building Products. precast basement solutions Hanson Building Products precast basement solutions Hanson Building Products Basement Systems Add an extra dimension and combine the inherent flexible, structural and waterproof properties of concrete

More information

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED CERTIFICATE OF APPROVAL No CF 291 This is to certify that, in accordance with TS General Requirements for Certification of Fire Protection Products The undermentioned products of Drummond Road, Stafford.

More information

Multi-layer Insulation Blanket for Roofs

Multi-layer Insulation Blanket for Roofs Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof

More information

Window Installation Instructions

Window Installation Instructions Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for

More information

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope STEEL BUILDINGS IN EUROPE Single-Storey Steel Buildings Part 8: Building Envelope Single-Storey Steel Buildings Part 8: Building Envelope 2 - ii Part 8: Building Envelope emissions

More information

Mineral fibreglass insulation

Mineral fibreglass insulation Isover MULTIMAX 30 Specification code: MW - EN 13162 - T5 - MU1 - WS - WL(P) - AF r 5 TeChNICaL SPeCIFICaTION Insulating slabs made of Isover fibreglass wool. The production method is based on the fibering

More information

glass & Glazing Products

glass & Glazing Products glass & Glazing Products WallMaker Create an unlimited variety of bright, beautiful and secure interior environments with the easy-to-install Stylmark WallMaker glass wall system. This versatile system

More information

CLEAR-DIVISIONS APERTO

CLEAR-DIVISIONS APERTO CLEAR-DIVISIONS Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS moveable glass wall system. The yellow highlighted areas in the

More information

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM P r o d u c t a p p l i c a t i o n s a n d t e c h n i c a l i n f o r m a t i o n 2 below and above ground V OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM V The flexible, fast and cost-effective answer

More information

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES CERTIFICATE OF APPROVAL No CF 5055 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of 1 st Industrial Area,

More information

ONLINE VERSION. The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 ONLINE VERSION

ONLINE VERSION. The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 ONLINE VERSION The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 E1 E2 E3 E4 E Protection against sound from other parts of the building and adjoining buildings Protection against

More information

The Case for Cross Laminated Timber: Part 2

The Case for Cross Laminated Timber: Part 2 Learning Objectives The Case for Cross Laminated Timber: Part 2 Opportunities and Challenges for a New Class of Timber Product 1. Review answers to common questions regarding the design and construction

More information

Pipe Clamps and Accessories

Pipe Clamps and Accessories Products 4.0 Products 4.1 Connection options to pipe clamps with Triple-Thread Connector NT 3G (M16, M10, M8) 4.2 Connection options to pipe clamps with Triple-Thread Connector NT 3G (3/8", M12, M10) 4.3

More information

Building Control Guidance Note

Building Control Guidance Note Issued 01/01/13 Rev Page 1 of 5 If you intend to convert an existing loft space into additional rooms you will need to apply for Building Regulation Approval. You may also need Planning Permission if you

More information

Bafl-Sorb Sound Absorbing Ceiling Baffles

Bafl-Sorb Sound Absorbing Ceiling Baffles Bafl-Sorb Sound Absorbing Ceiling Baffles INC offers a complete line of Sound Absorbing Ceiling Baffles to compliment any environment. Our ceiling baffles are among the most cost-effective method of adding

More information

Fire Protection. CANADIAN STEEL CONSTRUCTION COUNCIL 201 Consumers Road, Suite 300 Willowdale, Ontario, M2J 4G8. Floor Assembly No.

Fire Protection. CANADIAN STEEL CONSTRUCTION COUNCIL 201 Consumers Road, Suite 300 Willowdale, Ontario, M2J 4G8. Floor Assembly No. BULLETIN No. 28 (a) Fire Protection CANADIAN STEEL CONSTRUCTION COUNCIL 201 Consumers Road, Suite 300 Willowdale, Ontario, M2J 4G8 Floor Assembly No. NRC764-FF22 Fire Endurance Period 1 74 minutes Sound

More information

research highlight Highly Energy Efficient Building Envelope Retrofits for Houses

research highlight Highly Energy Efficient Building Envelope Retrofits for Houses research highlight June 2012 Technical Series 12-103 Highly Energy Efficient Building Envelope Retrofits for Houses introduction In Canada approximately 30% of all energy is consumed in buildings, with

More information

H-Stud Area Separation Wall System

H-Stud Area Separation Wall System 12 TH EDITION 09 21 16.33/NGC H-Stud Area Separation Wall System 09 21 16.33 139 H-STUD AREA SEPARATION WALL SYSTEM The fire-protection of gypsum-based Area Separation Walls is demonstrated in dramatic

More information

CLEAR-DIVISIONS CENTERFOLD

CLEAR-DIVISIONS CENTERFOLD CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in

More information

Data Centres A complete solution to noise control and acoustic packages

Data Centres A complete solution to noise control and acoustic packages Data Centres A complete solution to noise control and acoustic packages Introduction World class noise control. Expertise you can trust. IAC Acoustics is world-renowned for providing cost effective solutions

More information

GigaCrete Specification PlasterMax

GigaCrete Specification PlasterMax GigaCrete Inc. 6775 Speedway Blvd. Suite M105 Las Vegas, NV 89115 Ph (702) 643-6363 Fax (702) 643 1453 www.gigacrete.com GigaCrete Specification PlasterMax PlasterMax : Fire Rated Plaster for Direct Application

More information

How To Repair A Boat Landing Deck With A Boat Bed

How To Repair A Boat Landing Deck With A Boat Bed RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD IS Table of Contents Slab-on-grade-to Above Grade Wall...1 Foundation Wall at Footing

More information

CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. North America Version

CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. North America Version CEILING SYSTEMS Between us, ideas become reality Installing Suspended Ceilings North America Version 1 Installing Armstrong Suspended Ceilings An Armstrong suspended mineral fiber ceiling is functional,

More information

Rockwool Cladding Roll

Rockwool Cladding Roll Rockwool Cladding Roll High performance industrial insulation has been specifically developed for use in lightweight cladding applications to commercial or industrial framed buildings. Cladding Roll U/F

More information

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape ModuSec Secure and efficient IT room solutions Turnkey Modular Construction Fast clean build to any size or shape Room in room Standalone external build Transportable Modusec SR Options Modusec SR Options

More information

ROXUL Board Insulation Section 07 21 13 Master Guide Specification (CAVITYROCK ) Page 1 April 2016

ROXUL Board Insulation Section 07 21 13 Master Guide Specification (CAVITYROCK ) Page 1 April 2016 Master Guide Specification (CAVITYROCK ) Page 1 Click on the pilcrow in the MS Word Toolbar to toggle ROXUL GUIDE NOTES on and off. Delete this text before incorporating the section into a Project Manual.

More information

plumbing products guide

plumbing products guide plumbing products guide radiator pipe guide & seals A significant development in the drive to reduce air leakage and heat loss. Installations such as that shown are all too common. The detail is poorly

More information

EAST LYME HIGH SCHOOL

EAST LYME HIGH SCHOOL Overview: 1971 N 1966 GYM 1966 CLASSROOM WING 1966 AUD. 1971 GYM 1998 1998 POOL EAST LYME HIGH SCHOOL Original 1966 Building: The original East Lyme High School was constructed in 1966 and was composed

More information

How to Estimate the Cost of Interior Building Finishes from Schematic Drawings. CPE Candidate No. 0714108. December 2014

How to Estimate the Cost of Interior Building Finishes from Schematic Drawings. CPE Candidate No. 0714108. December 2014 How to Estimate the Cost of Interior Building Finishes from Schematic Drawings CPE Candidate No. 0714108 December 2014 1 How to Estimate the Cost of Interior Building Finishes from Schematic Drawings Table

More information

Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors.

Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors. Fire & Soundproofing Insulation Roxul SAFE N SOUND Fire and Soundproofing Insulation for Interior Partition Walls and Floors. Roxul SAFE N SOUND Sound control and fire safety from one batt Insulation.

More information

Mold Preventing I nterior System

Mold Preventing I nterior System interior insulation and renovation boards A system of components that have been designed to work perfectly together to repair damage caused by mold. The system consists of boards, insulation wedges, reveal

More information

eading Performance Solutions

eading Performance Solutions eading Solutions Manage Risk Save Time and Money Grow Business Responsive Leadership As a construction professional, you face countless challenges. Every day you are expected to finish projects efficiently

More information

FIRESTOPPING & SMOKE SEALS

FIRESTOPPING & SMOKE SEALS SPECIFICATION SECTION 07 84 00 FIRESTOPPING & SMOKE SEALS 1 GENERAL 1.1 SECTION INCLUDES 1.1.1 Comply with Division 1, General Requirements and Documents referred to therein. 1.1.2 It is the intent of

More information

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances. Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org

More information

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage: Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial

More information

SPREFIX SPRAY INSULATION _ in the marine market.

SPREFIX SPRAY INSULATION _ in the marine market. SPREFIX SPRAY INSULATION _ in the marine market. A self-adhesive glass or stone wool, sprayed directly onto surface.. Easily applied to wood, steel, plastic or other surfaces without any mechanical fasteners

More information

EPIC. Uniclass. L5161+L542:N373 Cl/SfB E122:Y45 (42)+(45) R (P3)

EPIC. Uniclass. L5161+L542:N373 Cl/SfB E122:Y45 (42)+(45) R (P3) Uniclass L5161+L542:N373 Cl/SfB EPIC E122:Y45 (42)+(45) R (P3) CMS SuperPhon range Sound absorption for walls and ceilings Sound absorption Reverberation time is a measure of how long it takes noise to

More information