FLUSH STEEL DOOR FLUSH STEEL. 15mm rebated threshold. 5mm driveable (DDA compliant). 12 5mm 564A Aluminium (DDA compliant).

Similar documents
Standard Door Specification

Code of Practice for fire resisting metal doorsets

Modular mortice locks

What locks do I have Timber Doors

Panic Exit Devices. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

FIRE DOORS - GENERAL SPECIFICATIONS / EMPLOYERS REQUIREMENTS (ERs) & QUICK OVERVIEW

RADAR

PROOF ONLY. Police and Fire Service Home Security & Fire Safety Checklist. Student Accommodation Security Checklist

ABLOY EXIT. Functional and technical descriptions Single and double leaf doors. An ASSA ABLOY Group brand

PHA 2000 PHB 3000 EXIT PAD

WE ARE UNION. replace with new shot. Mortice Lock Range. ASSA ABLOY, the global leader in door opening solutions

Approved Document Q: Security

Narrow stile lock 1314

NEWSTAR BROCHURE. December 2007

Panic & emergency exit devices

Sliding and Folding Door Fittings Sliding Door Accessories

Fire doors guidance. Safety and Health Services. Document control information. Date issued: January Version: 2. Previous review dates: 2011

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

Automatic Door Selection Guide

COASTAL SERIES. 316 Solid Stainless Steel Door Furniture

Droveway ARCHITECTURAL SERVICES. Disability Access Audit. Sample Gospel Hall. 22 September For

Relevant British, European and International standards

Key in Knob & Key in Lever

Mortice Lock. ASSA ABLOY, the global leader in door opening solutions

Fire Doors Basic Guidance & Checklist

K17.11 DOOR BOLTS K17 DOORS

Architectural Nylon. Architectural. Nylon

CDW Systems Ltd Contemporary Doors & Windows

Protect your home with

NOT PROTECTIVELY MARKED

DOORS HOLLOW METAL MANUAL NAAMM STANDARD NAAMM HMMA METAL DOORS & FRAMES METAL. A Division of

ABLOY EXIT MECHANICAL LOCK CASES Technical descriptions

a practical guide to home security.

K17.12 Door closers K17. Doors

HARDWARE LOCATIONS FOR HOLLOW METAL DOORS AND FRAMES

Tel: Sales: STORAGE CABINETS. PREMIERSHIELD anti-bacterial powder coating system. quality products made in the UK

GENERAL FIRE SAFETY TERMS & DEFINITIONS

EXIT HARDWARE. Uniclass L CI/SfB (31.59) Xt7 VERSION: AUGUST-11. An ASSA ABLOY Group brand

Rose Door Handles. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

RIM MOUNTED AND DUAL ACCESS LOCKS

GLOSSARY OF LOCK TERMINOLOGY

CI/SfB. (31.59) X NOVEMBER 2003 Coburn Interior Sliding Systems

CATALOGO PRODOTTI PORTONI INDUSTRIALI COIBENTATI

Euro Profile Mortice Locks

Fire Resistant Systems

Basic Fire Door Requirements

MagTek A. Aluminium Manual Attack Resistant Doors

Windows, French doors, folding windows, terrace doors SFB 1074 with low U-values

Security steel door dw 52-1 Teckentrup DF WK 2 optionally with glazing/ventilation grille

A Complete Solution CREATING WALLS THAT DEFINE SPACE

HMMA 830 HARDWARE SELECTION FOR HOLLOW METAL DOORS AND FRAMES HOLLOW METAL MANUAL -02 NAAMM STANDARD METAL DOORS & FRAMES NAAMM 01 NAAMM 01

Security Screen Door Hardware

Office of the State Fire Marshal. Fire Rated Doors

2.02. Specifications. General. Products. Execution. Offset Pivots P-694 Top and Bottom Pivots

Planet Frameless Glazing. Planet 20 frameless glass swing door

Smooth & Seamless Hygienic Doors for the Food Sector

SECTION 6. Glass Storefront Doors:

Installation Detailed installation instructions are provided which should be strictly followed.

DIVISION HARDWARE FORMAT 1. Technical specifications content and numbering system shall be based on 2004 CSI MasterFormat.

Novoferm Interior Doors and Frames Just what you re looking for

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Hygienic Doors for the Healthcare Sector

Technical data sheet PVC Bi-fold doors

5.1. Smoke Sealing. General: The test procedure for smoke sealed doorsets is given by reference to BS476 Section 31.1.

Side Hinged Doors GSW 40-L

HMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES

Wood Sound Retardant Door Hardware Information Bulletin

Building Control Guidance Note

Exit Devices TABLE OF CONTENTS

BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401

Lift-off hinge. Rising hinge. Standard hinge. Heavy duty hinge. Parliament hinge. Spring hinge. Double action spring hinge. Concealed mortise hinge...

Fire Resisting Rolling Shutters & Doors

security solutions for your home

CHANNEL LETTERING INDOOR & OUTDOOR TRADE SHOW DISPLAYS CONSTRUCTION SIGNAGE VEHICLE GRAPHICS REAL ESTATE / DISPLAYS WINDOW GRAPHICS POSTERS

Safety. Fire Resistant. Gas Cylinder

An ASSA ABLOY Group brand. 4800LN Series. Interconnected Locks

Guidance on loft conversions in two-storey houses

Lock Function Chart Page 1 of 7

THE IDEAL SOLUTION SHELVING. Sales Telephone: Sales Fax:

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

Series 602 MAGNUM Sliding Window DESIGNER SERIES

The Role of Fire Doors. BWF-Certifire Fire Door and Doorset Scheme

C A T A L O G U E c l i c k a n y w h e r e t o c o n t i n u e

Synergy Mortice Locks

ISSUE 2. Installation Guide

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape

Garage Sectional Doors

FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.

BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping.

Manual on Door and Window Details for Residential Buildings. Volume-1. Govt. of India Central Public Works Department

Product Management - Glass ALEXA PRODUCT PRESENTATION. Region SAARC Nitin Lloyd, Product Management. Chennai, FY 2013 / 2014

Fabrication Illustration Part No. Description Door Frame. P092 Mortised Butt Hinge P092D P092F (includes P2092 $ 48 $ 21 frame/door reinforcing)

Security Shutters, Retractable Security Gates, SeceuroBar & Aluminium Folding Shutter

Glass partitions SFB 3074

FIRE RATED GLAZING System Guide

Mechanical Digital DX Locks

Transcription:

FLUSH STEEL DOOR DOOR LEAF Thickness: Material: Infill: 48mm 1 2mm corrosion resistant Zintec/Aluzinc sheets as standard, wide variety of colours and finishes available. Also Stainless Steel. Self supporting resin-impregnated honeycomb core as standard. Optionally Mineral Wool or Solid Timber. Doorblade manufactured from two 1 2mm sheets lockformed together, by bonding two steel skins around a rigid core, using a no-weld construction. Note: Stock doors are fitted with a universal lock which when not required can be replaced with a blanking plate. DOOR FRAME Profile: Folded from 1 6mm Zintec/Aluzinc. Screw and tab construction with 4no. adjustable fixing feet per jamb, variable subframe supplied as standard to accommodate site tolerance of -0/+30mm. The frame is fitted with 3no. Class 13 stainless steel hinges with 2no. security dog bolts. FLUSH STEEL THRESHOLD FINISHES SIZES Size: Stock: Type A Type B Type C Type D 15mm rebated threshold. 5mm driveable (DDA compliant). 12 5mm 564A Aluminium (DDA compliant). Standard Driveable 564A None (optional) (optional) (optional) Pre-primed steel (approximating to BS10A05 Goosewing Grey) requiring site painting. Polyester Powder Coating from standard colour range. PVC laminate from standard range. Woodgrain PVC laminate. Stainless steel, brushed, polished or patterned. Doors are custom manufactured in 10mm increments for single openings 690mm to 1390mm and double openings 1290mm to 2600mm, at heights up to 2900mm. Stock sizes are held in 50mm increments for single openings 690mm to 1390mm and double openings 1290mm to 2600mm, at a standard height of 2100mm. Contact the Sales office for special configurations and finishes.

VISION PANELS Guidance Notes: Options : To comply with Part M of the Building Regulations 2004 doors across circulation routes should have visibility glazing. (Vision panels less than 50% of the total door area are exempt from Part L of the Building Regulations.) Welded construction from 1mm cold rolled steel, screwed together from one side. Standard glazing is 6.4mm clear laminate. Alternative options include 6mm GWPP or a 19mm Double Glazed Unit (6.4/6/6.4 mm laminate). Custom sizes and glass are available to customer requirements. FLUSH STEEL LOUVRE PANELS Options : PANEL ARRANGEMENTS Sizes: Options: Standard Louvre offers 50% air flow with louvre blades constructed to stop birds. Frames are 1.2mm thick and blades 0.7mm. Fly mesh available as an optional extra. Custom sizes are available. Panels can be solid, glazed or louvred. Standard side panels are available up to 1340mm wide x 2900mm high. Standard over panels are available up to 1340 x 2900mm (single door) or 1340 x 2600mm (double door). Hinged panels. Removeable, flush, glazed or louvred are all available. Please consult the Sales office with specific requirements.

DOOR LOCKING All lock cases are tested to BS EN 12209 and all lever furniture is tested to BS 1906. MORTICE LOCKS & LATCHES DEADLOCK ALT 1 Deadlock fitted with external cylinder pull, double cylinder and internal escutcheon. Standard for plant rooms. DEADLOCK ALT 2 Deadlock fitted with 19mm bolt through handle, and push plate to opposite side. Double cylinder with escutcheons as standard. DEADLOCK ALT 3 Deadlock fitted with double 19mm bolt through handle. Double cylinder with escutcheons as standard. LATCH The standard latch fitting is with a pair of 19mm stainless steel levers, suitable for non-secure doors to provide privacy. DOOR LOCKING SASHLOCK The standard fitting for sashlocks is with pair of 19mm stainless levers and a double cylinder deadbolt. Illustrated is optional thumbscrew on non-secure side. NIGHTLATCH ALT 1 Suitable for automatic locking entrance doors, used manually or in conjunction with an electric strike. Illustrated optional cylinder pull. TOILET LOCK As the sash lock but the deadbolt is fitted with a privacy/indicator set instead of a cylinder. NIGHTLATCH ALT 2 As Alt 1 but fitted with a pull handle. Doors fitted electric strikes provide key access for authorised persons as a manual override, whilst the internal handle gives escape at all times. NIGHTLATCH WITH SNIB The snib allows the locking latch to be secured within the lockcase giving free access. Doors with night latches are normally fitted with closers. MORTICE MULTI-POINT LOCKING 3-POINT SASHLOCK This lock has a sashlock fitted centrally with top & bottom deadbolts. The cylinder operates all locks from the central point. Either a double or euro cylinder & turn can be fitted. An escape version is also available. Note this lock is only available on custom built doors. ADDITIONAL LOCKS Additional locks, usually deadlocks, can be fitted to standard doors to aid security. In the illustration are additional deadlocks & a sashlock, which can be fitted in either the upper or lower quarter, or both. The standard option is two locks, one fitted centrally and one in the lower quarter (it is more difficult to apply leverage to the upper half of a door when attacking it). Additional locks can be fitted with panic bolts and latches to provide night time security, subject to Fire Regulations.

LOCKING: ACCESS CONTROL DOOR LOCKING MECHANICAL KEYPAD As standard this is provided with a latchbolt complete with a pair of stainless steel levers and a deadbolt for security, operated by a double cylinder. Illustrated is optional thumbscrew on non-secure side. ELECTRIC STRIKE As standard the door blade is fitted with a nightlatch complete with an external pull handle and internal half-lever. The lever allows manual egress from the inside (this can be replaced by a push button or a secure access system). A half-cylinder can be fitted to allow fail-safe override. The strike can be activated by the full range of secure access systems, eg. keypad, swipe card, etc. Available in 12 or 24vDC and with Fail Open (power to hold strike) or Fail Closed (power to open). DOOR LOCKING ELECTRO-MAGNET LOCK, SURFACE MOUNTED Available in 12 or 24vDC the magnet can be activated by the range of security access systems, eg. keypad, swipe card, etc. It is fitted to the frame with a bolt through armature plate on the door blade. The magnet is locked when power is applied and automatically Fails Open when is removed. The lock can be fitted to single or double doors. ELECTRO-MAGNET LOCK, CONCEALED MOUNTING The door is fitted with two mag-locks flush mounted into a special frame section, whilst the armature plates are recessed into the door blade. This arrangement is ideal for high traffic entrance doors to offices and flats, as it provides an esthetically pleasing door offering high secuirty and resistance to attack or abuse. The lock can be fitted to single or double doors (on double doors only active leaf operation is allowed).

FIRE RESISTANT STEEL DOORS Our Fire Resistant Steel Doors, are fitted in internal and external applications in a wide variety of wall constructions, and designed to protect personnel & property from the spread of flames & smoke. They offer substantial benefits over comparable timber doors; strength, durability & security. The range has been tested to BS 476 Parts 20 & 22, BS EN 1634 and holds appropriate FRS & Bodycote Warrington Assessments. VERSIONS FD60: Providing protection up to One Hour (60 minutes) in a traditional unlatched design. FD120: FD240: Providing protection up to Two Hours (120 minutes) with a latched design. Providing protection up to Four Hours (240 minutes) with a latched design. Please contact the Sales Office for special configurations DOOR LEAF Production Sizes: Thickness: Material: All fire resistant doors are custom made, to a maximum width of 1250mm as a single and 2600mm as a double. A maximum height of 2800mm in a single leaf. Infill panels to side or top can be provided as optional extras. 48mm. 1 2mm corrosion resistant Zintec/Aluzinc sheets as standard. Wide variety of colours and finishes available. FIRE RESISTANT Infill: DOOR FRAME Profile: THRESHOLD FINISHES Self supporting resin-impregnated honeycomb core as standard, with the option of mineral wool. A non-welded construction from two skins of Zintec folded around a rigid core. Folded from 1 6mm Zintec/Aluzinc. Screw and tab construction with 4no. adjustable fixing feet per jamb, variable subframe supplied as standard to accommodate site tolerance of -0/+30mm. The frame is fitted with 3no. Class 13 stainless steel hinges with 2no. security dog bolts. Type A Type B Type C Type D 15mm rebated threshold. 5mm driveable (DDA compliant). 12 5mm 564A Aluminium (DDA compliant). Standard Driveable 564A None (optional) (optional) (optional) Pre-primed steel (approximating to BS10A05 Goosewing Grey) requiring site painting. Polyester Powder Coating from standard colour range. PVC laminate from standard range. Woodgrain PVC laminate. Stainless steel, brushed, polished or patterned.

VISION PANELS Guidance Notes: Fire Assessment: Options : To comply with Part M of the Building Regulations 2004, doors across circulation routes should have visibility glazing. (Vision panels less than 50% of the total door area are exempt from Part L of the Building Regulations.) Under the BRE Assessment the following rules apply: Maximum panel size 637x592mm (0.377m²) No vision panel to be fitted within 200mm of any door leaf edge. Standard glazing is 6mm GWPP Safety (up to 2hrs. integrity). Alternative options include 6mm Firelite Clear Ceramic Glass (up to 4hrs. integrity). FIRE RESISTANT LOUVRE PANELS Fire Assessment: FD60 & FD120 The louvre panel has moveable steel blades which can be closed manually. The blades are also closed by a fail-save fusible link set to melt at 160. FD240 (optionally FD60 & FD120) The panel is constructed of 2 separate steel louvre panels fitted on either side of an intumescent fire block core. Under the BRE Assessment the following rules apply: Maximum panel size 610x610mm (0.372m²). No louvre panel to be fitted within 200mm of any door leaf edge. The louvre panel top should be not more than 1000mm from floor level. FD60 & FD120 FUSIBLE LINK LOUVRE FD240 (FD60 & FD120) INTUMESCENT BLOCK LOUVRE