Series 18 Pass Thru Air Lock Cleanroom Entry System



Similar documents
ATS Overhead Table Shelf System INSTRUCTION MANUAL

Cooktop Low-Profile Ventilation Hoods

Doorbell Intercom Security System

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

All-Season Sunroom Sliding Glass Door Installation Instructions

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

Spetec Laminar Flow Systems. Operating Instructions

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

OWNER S MANUAL Table Tennis Table Patent Pending

ROTOR LOADER OWNER S MANUAL

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

Speed-Mat Rectangle Cutter

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

STAINLESS STEEL WINE / BEVERAGE COOLER INSTRUCTION MANUAL HVBC31ST

Chemical Fume Hoods. Environmental Health and Safety

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

Sun Vinyl New Construction Windows Homeowner's Warranty

DCF Optimized Rack System

MIRAGE. Set-Up Instructions.

Andersen Electric Window Opener for Andersen Awning and Roof Windows

Installation Instructions

Digital Photo Picture Frame. Operation Manual

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

Stainless Steel Worksurface 3 Feet Hood A10-WS-PR3 A10-WS-SR3 4 Feet Hood A10-WS-PR4 A10-WS-SR4 6 Feet Hood A10-WS-PR6 A10-WS-SR6.

149mm. Walk-Thru Assembly Gate. MODEL NO: 1161, 1167 Owner s Manual.

ANI-64S-xRU. Single Section Wall Cabinet INSTRUCTION MANUAL

Destiny Shower Enclosure Installation Instructions

ARTS AND CRAFTS (open) 5412 (doors) H : 84" Tote Tray Storage. Damp Storage. Tote Tray Storage. Notebook Board Storage, Doors

Laboratory Safety and Environmental Health Assessment Program

LABORATORY SAFETY INSPECTION CHECKLIST

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

National Optical & Scientific Instrument Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Bottom Loading Water Dispenser

Calvert USA, Inc. Attic Stairs

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Wine Cooler with Thermo-Electric Cooling & Heating Technology

GenStore Archive Cabinet

TABLE OF CONTENTS QUICK START... 1 DIAGRAM OF THE DIGITAL PHOTO FRAME... 2 KEYPAD BUTTON FUNCTIONS... 3 REMOTE CONTROL FUNCTIONS..

Spetec. Laminar Flow Box. Portable Clean Room Technology

3 WATT LED SPOTLIGHT Model No. SLM

Retractable Screen. Replacement Screen Instructions

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

SECTION 6. Glass Storefront Doors:

XPanel V2. Remote Control Panel. User Manual. XILICA Audio Design

Mini-led spotlight with magnetic base

Installation Instructions

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

BUILT-IN WINE & BEVERAGE COOLER WITH DUAL TEMPERATURE ZONES INSTRUCTION MANUAL. Model No.: MCWBC77DZC

GSM Door Phone System

20 GALLON WET DRY VACUUM

Congratulations on your purchase of the Great Planes SLOT MACHINE, the first truly easy way to cut hinge slots in your model airplanes.

Rack installation instructions

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

MAINTENANCE & TROUBLESHOOTING

HOW TO... Channel Window Balances

-1- SPECIFICATIONS CONE SETTER PLATFORM ATTACHMENT INDEX

Unpacking, Installation, and Customization

758 Heavy-duty Ratchet Guy Wire Cutter

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

HOW TO INSTALL A BEAUTIFUL NEW KITCHEN

Laminar Flow Cabinets

Rack Installation Instructions

SSG PRODUCTS FOR SHIPS AND OFFSHORE

Packaged Terminal Air Conditioner Wall Sleeve Installation

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Owner s Guide and Installation Manual. Vancouver Model Name , Model No. English Español

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11

Customer Service or visit us online at smithnoble.com. Wood Shutters. Step by Step Installation. Troubleshooting Tips

Electric Egg Boiler. Instruction Manual. Model Number: AEB-917

K17.12 Door closers K17. Doors

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

IMPORTANT SAFETY RULES TO FOLLOW

ReadyKart Mobile Processing Station Instructions for Use

12-Volt 10-Amp Regulated Power Supply

E-PDD Duct Smoke Detector Installation Sheet

Instruction Manual. AWK-115S

Integral Kit Instructions

TABLE OF CONTENTS CABINET SAFETY

WHYNTER 21 Bottle Dual Temperature Zone Freestanding Wine Cooler

LAMINAR FLOW CABINETS

PUBLIC RESTROOMS, DESIGN INTENT

F-900 HOPEC Bench Hood Framed Vertical Sash

Installation Guide. 5 Series 15 W. Undercounter/Freestanding Nugget Ice Machine

HYLA NST Cleaning System

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

LIFT N RACK PRO OPERATING & INSTALLATION GUIDE 5500 Lb. LIFT CAPACITY

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

MGB Chrome Bumper Conversion

16/32 Channel 1U Rack Mount CCTV Power Supply

Customer Support

Ultra-Violet Products Ltd 2066 W 11th Street, Upland, CA Unit 1, Trinity Hall Farm Estate

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

DIRECTIONS FOR ASSEMBLING BASE & WALL CABINETS

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Installation Instructions

INSTRUCTION BOOK FOR. Lace And Grommet Theater-Type Screens

ELECTRIC KNIFE SHARPENER

Transcription:

OPERATION & MAINTENANCE INSTRUCTIONS FOR Series 18 Pass Thru Air Lock Cleanroom Entry System SOLUTIONS BUILT TO YOUR SPECIFICATIONS 8605 Wyoming Ave. N. Minneapolis MN 55445 fax: 763.425.2004 e-mail: sales@cleanairproducts.com

S O L U T I O N S Wall-mounted pass thru with mechanical interlock Floor-mounted pass thru Series 18 Pass Thru Air Lock Cleanroom Entry System Pass thru air locks are for the transfer of parts and equipment in and out of a cleanroom. They reduce the need for people to enter the cleanroom. Contamination is eliminated because of the reduced traffic within the cleanroom. Clean Air Products Series 18 features polypropylene or stainless steel construction not particle board. The Series 18 pass thru air locks are manufactured using two types of materials: white polypropylene and stainless steel. The polypropylene units are constructed of 1/2-in. white sheets that are welded together. Polypropylene is a solid plastic that contains no particle board and is a superior construction material. Pass thru cabinets made with laminated formica over particle board construction can crack, chip, delaminate, and promote the growth of biological contamination. The Series 18 uses solid polypropylene sheets to prevent this type of deterioration. The stainless steel cabinets are constructed with a welded stainless steel shell. They are extremely strong, durable, easily cleaned, and provide a superior look to your cleanroom. The stainless steel pass thrus are all metal except for the viewing window. They contain no particle board. The air lock doors are made with a heavy-duty stainless steel frame, stainless steel continuous-hinges, tempered safety glass viewing window, closed-cell PVC door gasket, and 90-degree turn-knob latch or cam action chrome-plated latch on larger units. The stainless steel door frame design adds strength, prevents long-term warpage, and prevents cracking of an all-plastic door. (Cracking of all-plastic doors is a common problem.) Mechanical door interlocks are available to prevent both doors from being opened at the same time. This prevents cleanroom depressurization and infiltration contamination. 8 For more information or to download or fax this product from the web, simply go to: /18

Wall-mounted Pass Thru B B H H D D Floor-mounted Pass Thru A W Optional stainless steel mounting frame W A Optional stainless steel mounting frame Wall Mount Dimensions (inches) Stainless Steel Pass Thrus Inside Outside Dimension Dimensions W H D A B 12 12 12 16.75 14 Quick Ship Size* 18 18 18 22.75 20 Quick Ship Size* 24 24 24 28.75 26 Quick Ship Size* 30 30 30 35.25 33.25 Polypropylene Pass Thrus 36 36 36 41.25 39.25 Inside Outside 46 46 30 51.25 49.25 Dimension Dimensions 46 46 46 51.25 49.25 W H D A B *Call factory for quantities available. 12 12 12 16.5 13 Custom sizes available upon request. 18 18 18 22.5 19 24 24 24 28.5 25 30 30 30 34.5 31 36 36 36 40.75 37.5 Custom sizes available upon request. Floor Mount Dimensions (inches) Stainless Steel Pass Thrus Inside Outside Dimension Dimensions W H D A B 30 36 30 35.375 37.625 30 48 30 35.375 49.625 30 54 48 35.375 55.625 36 36 36 41.375 37.625 36 48 36 41.375 49.625 36 48 48 41.375 49.625 36 48 60 41.375 49.625 42 48 36 47.375 49.625 42 60 54 47.375 61.625 Custom sizes available upon request. Options Optionally furnished with a 4-piece stainless steel angle perimeter frame for mounting the unit to the walls of the cleanroom. (One 4-piece frame per side.) The unit sizes are based on inside dimensions. Options for the Series 18 include: Stainless steel White polypropylene Wall or floor mount Mechanical interlock Perimeter frame Special sizes Shelves fixed or adjustable Doors with acrylic, acrylic amber, polycarbonate, PVC, safety glass, or conductive PVC in the viewing windows Solid stainless steel doors, no windows UV light Floor mounted for carts HEPA filters or air shower part cleaning 90 degree pass thru Fire rated pass thru Integrated sloped top pass thru Vertical sliding door pass thru Double door pass thru Additional options available upon request Guarantee A written 1 year warranty is furnished with each air lock. Specifications subject to change. Please contact factory for details. 2 Clean Air Products 2010 INDD0018-1D 1.4.10

Installation of Series 18 Air Lock Pass thrus are to be installed so that they are square. Units without mechanical interlock need to be square so the door lines up with the door catch. For units with mechanical interlock, there is a pin on the front door that fits into a rectangular slot on the face of the pass thru. If the Pass Thru is not installed squarely, the door pin will not fit through the hole and the unit will bind. The pass thru should be well supported on all sides so it will not shift when weight is inserted. Also, if it is not securely mounted, it will loosen over time. After installation, it may be required to adjust the tension on the door latch to make sure it holds the door closed but is not too hard to turn. Operation (Units without mechanical interlock) To open the door, turn the knob releasing the door latch. Open the door, put in or take out, then close the door. Do not have both doors open at the same time. This will cause the room to lose pressure. Operation (Units with mechanical interlock) The system uses a mechanical interlock that works by having a pin located on the door to through the rectangular hole in the front face of the pass thru. This door pin presses in a spring-loaded release inside the unit that unlocks the interlock mechanism and allows the tee handle to turn. With both doors shut, the tee handle will be vertical on one side and horizontal on the other. The tee handle can be rotated 90 degrees when both doors are shut. When the tee handle is vertical, that door can be opened. On the other door the tee handle will be horizontal. The handle will cover up the edge of the door, holding it shut, and preventing it from opening by the internal interlock mechanism. To open the door, the handle needs to be turned 90 degrees to the vertical position. However, if one of the handles cannot be rotated because of the internal mechanism, shut the open door. The tee handle will now allow the other door s tee handle to be vertical, allowing the door to be opened. Note: The internal spring release can be damaged by forcing the tee handle to turn. The interlock can be by-passed using a small round cylinder such as the eraser end of a pencil to push in the pin and turn the tee handle. For this reason, this style of interlock should not be used in high-security areas. It is to be used as a deterrent to both doors being opened at the same time. Troubleshooting Problem: The pin on the door does not fit into the rectangular slot. Check the square of the unit. Check to see that the zee pin on the door has not been bent. A very minor bend may be required to get it back into correct alignment. Problem: The tee handle turns regardless of what position the doors are in. Look inside the rectangular slot in the front of the cabinet to see if the spring loaded pin located inside the shell extends out. By pushing on the pin lightly with a blunt end of a pencil, the pin should move in and out. Push it in and turn the tee handle and check the other side. To replace the pin, either pull the pin out through the slot in the front of the pass thru or take off the interior side panel. Problem: Cannot get the tee handle to move when the door is closed. Check to see that the zee pin on the door is actually mounted on the door. Someone may have taken it off. Check that the zee has not been damaged so that it does not go into the pass thru long enough to depress the pin. Maintenance 3

1. Once a day wipe down the interior surfaces. Dirt will get into the pass thru while the dirty side door is open. Particles can float into the pass thru and settle on the interior. This dirt can then be transferred into the cleanroom. 2. Once a day wipe down the interior cleanroom knobs. Because people are going into a gray area, (the interior of the pass thru) the knobs can get dirty. 3. Wipe the acrylic doors LIGHTLY with soft cleanroom wipes. This will prevent scratching of the viewing window. 4. Once a year check that the pass thru is still securely mounted. Check all perimeter mounting screws. Service Parts Part # 18-zee 18-pin 18-knob 18-gask 18-door 18-plex Description Door zee Spring pin (on the interior of the pass thru) 90 degree turn door latch and knob Door gasket Door assembly with stainless steel frame and viewing window Need to give pass thru size Plex for the door. Goes into the stainless steel mounting frame. 4

Read and Save these Instructions! Please observe the following information related to the product: 1) Read this guide before installing and/or operating the unit. 2) Keep this guide to make references to the safety and operating instructions in the future. 3) Observe warnings associated with handling, installing, using, and maintaining the CAP18. 4) Follow all instructions for set-up, operation, and use. 5) Operate ONLY from the type of power source indicated. If you are unsure of the type of power available to you, contact your dealer or power company. 6) This unit may be equipped with a polarized alternating current (AC) plug with one blade wider than the other. This plug will only fit into the power outlet in one way for safety reasons. If the plug does not fit, call an electrician to replace the outlet. DO NOT REMOVE THE ROUND GROUNDING TERMINAL. THIS UNIT MUST BE GROUNDED FOR SAFETY REASONS AND FOR PROPER OPERATION. 7) Do not place power cords (optional) where they will have things placed on or against them, be walked upon, or be pinched, especially near the outlet, the plug, or where the power cord exits the unit. 8) Overloading outlets and/or extension cords can result in fire and/or electrical shock. 9) ONLY use parts supplied or authorized by the manufacturer. Substitutions may result in fire, electrical shock, or other safety hazards. Safety Warnings 1) NEVER expose the assembly to moisture or rain. 2) If the unit gets wet, disconnect the power at the source and have an authorized service inspection before using it again. 3) Do not pull on the optional power cord to unplug the unit, and never handle the cord with wet hands. 4) Do not clean the unit with flammable chemicals. 5) Do not expose to explosive or hazardous vapors or materials. 6) Make sure the unit is well supported to prevent falling. 7) Do not block airflow to the unit. 8) Disconnect the power before servicing. 9) Do not operate below 0 degrees Fahrenheit or above 110 degrees Fahrenheit. 10) This unit is designed to operate in a non-hazardous (non-explosive) environment with non-condensing air. 11) NEVER put objects into the blower. 12) Do not operate without metal blower guard. 13) Review application with your safety commissioner for proper use. 5

Warranty for Cleanroom & Equipment Clean Air Products Corporation warrants that it will repair FOB its factory or furnish without charge FOB its factory a similar part to replace any material in its equipment within one year after the date of sale if proved to the satisfaction of the company to have been defective at the time it was sold provided that all parts claimed defective shall be returned, properly identified to the company at its factory, freight charges prepaid. Factory installed equipment of accessories is warranted only to the extent guaranteed by the original equipment manufacturer, and this warranty shall not apply to any portion of the equipment modified by the user. Claims under this warranty should be directed to Clean Air Products, 8605 Wyoming Avenue North, Brooklyn Park, MN 55445, setting forth in detail the nature of the defect, the date of the initial installation, and the serial number and model number of the equipment. HEPA filters are warranted to have their given efficiency at the time of shipping. Parts shipped to replace warranty items shall be invoiced out with 60 day terms. Credit shall be issued when defective parts are returned to Clean Air Products factory. (Contaminated materials shall be credited after receipt of proper disposal is sent to Clean Air Products.) When special shipping containers are used to ship out new product, defective parts are to be returned in the same container. This shall be so stated on the Bill of Lading sent with the replacement parts. Contaminated Parts and Equipment Clean Air Products must be notified if defective parts, or other materials supplied to the purchaser are contaminated with hazardous chemicals or carcinogenic materials that are considered hazardous or carcinogenic by the EPA or other regulatory agencies. These parts are not to be shipped back to Clean Air Products factory. The purchaser shall be responsible for proper disposal and all costs associated with the disposal and/or storage of the defective contaminated equipment. Prior to their disposal, Clean Air Products may require inspection of said defective materials. The user and purchaser shall each be responsible and be back charged for cleanup and disposal of all contaminated materials shipped back to Clean Air Products factory. Specifications subject to change. Please contact factory for details. 6

CUSTOMERS WALL ANGLE EQUAL TO PASS THRU WIDTH WALL CUTOUT HEIGHT NOTE: CUT WALL HOLE 1/2" LARGER THAN PASS THRU SIZE WIDTH A THREAD FORMING SCREWS POSITION PASS THRU IN OPENING AND INSTALL 1 SET OF MOUNTING ANGLES TO PASS THRU - RE-INSTALL INTO OPENING, LEVEL AND ATTACH TO WALL - GO TO OPPOSITE SIDE AND ATTACH OTHER WALL ANGLES SCREWS TO MOUNT UNIT TO WALL (SELECT APPROPRIATE TYPE FOR YOUR APPLICATION) NOTCHED ANGLE IS 5 INCHES TALLER THAN PASS THRU HEIGHT DETAIL A SCALE 1 : 3 Clean Air Products Series 18 Pass Thru Mounting (A41834.9005) 7

4 7 CHECK LIST FOR SERVICED PARTS: CAP18 - PASS THRU 90 DEGREE TURN LATCH WITH INTERLOCK 1. 2. DOOR WINDOW MATERIAL DOOR HINGE (NOT SHOWN) 3. DOOR FRAME - 304 STAINLESS STEEL 6 4. DOOR LATCH (WALL MOUNT MODEL) - 110256.0101 A 5. DOOR LATCH (FLOOR MOUNT MODEL) - 110256.0201 6. MECHANICAL INTERLOCK HANDLE - 141147.0101 7. MOUNTING ANGLES (WALL MOUNT MODEL) 1 DETAIL A 3 WALL MOUNT MODEL 8. MOUNTING ANGLES (FLOOR MOUNT MODEL) OVER-CENTER DRAW LATCH WITH INTERLOCK 5 1 B 8 DETAIL B 6 3 FLOOR MOUNT MODEL Clean Air Products Series 18 Pass Thru Mounting (A41834.9002) 8 Clean Air Products 2010 INDD0018-3F 1.4.10

Cleanroom Solutions Made Easy! Laminar Flow Clean Benches Modular Cleanrooms Vertical Flow HArDWALL Dust Containment Cabinets Fume Hoods We Build Hassle-Free Modular Cleanrooms Vertical Flow SoFTWALL Wet Process Stations Coat racks Formica Tables Gowning Benches Cleanroom Solutions Filters Stainless Steel Tables Desiccator Cabinets Storage Cabinets Air Showers Pass Thru Air Locks Wall & Ceiling Modules 8605 Wyoming Ave. N. Minneapolis MN 55445 tel: 763.425.9122 800.423.9728 fax: 763.425.2004 e-mail: sales@cleanairproducts.com