Nelson Washbasin Pre-Install Instructions

Similar documents
Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

Saferand easierinstallation

UNIVERSAL MOUNTING SET (UMS) FOR ARTOLINK FSO EQUIPMENT

INSTALLATION & USER INSTRUCTIONS WALL MOUNTED LCD ELECTRIC FIRE

EVOKE LCD ELECTRIC WALL HEATER MODEL : L23LCD INSTALLATION AND USER INSTRUCTIONS

1. Geo Vertical 2. Geo Horizontal

Operating Instructions. Room temperature controller

AMS 120. EFT Guest Card Terminal & Refund unit

How To Use A Mnet Converter

Installation. Smart-UPS VT and MGE Galaxy Maintenance Bypass Panel with Power Distribution (wall-mount) kva 208 V

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

GENERAL SHIELDING REQUIREMENTS FOR DIAGNOSTIC X-RAY FACILITIES. Major Medical (Radio/Fluoro/CT/Cardiac/Chiropractic)

TYPICAL WIRING OF METER SOCKET FOR SINGLE PHASE, THREE WIRE OVERHEAD SERVICE

Wall installation for Samsung Galaxy

STR-600 Plate Dryer. 1. What it s meant for?

1. Description. 2. List of Accessories included A B C F G H

Awning Instructions. Full Cassette 1.5m to 6m

fischer Test Report Fixing Tests for Wienerberger Porotherm blocks

Samuel Shorty Bunk Bed

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

SIMULATION PRE-INSTALLATION GUIDELINES CONTRACTOR REQUIREMENTS FOR ROOM PREPARATION

LIEBERT VNSA Installation Sheet

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Installation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

Batibox TM flush-mounting boxes for dry partitions

Chapter 5 FLOOR LOADING AND WEIGHTS

ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.

CoolWave r 2 Phase Control Board and Cable Replacement Kits

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand

Installation Instructions

Requirements for Electrical Installations

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

Hollow or Cinder Block Wall Mount Job Aid

MOUNTING INSTRUCTIONS

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

Park View Place. Compass. House. Royal Wharf Gardens Endeavour. House. Thameside. Sienna. House. House. Apartments Townhouses.

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Rousseau 10. User Guide

ORION 40 DS lamp WALL version

Drayton Digistat +2RF/+3RF

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Installation options, Europe

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

SERVICE MANUAL Order No.WH0911S001V0

DM1101, DM1103, DM1104 DM1103-L, DM1103-S Manual call points Manual release button and emergency stop button

TECH SUPPORT NORTH SEMORAN BLVD ORLANDO FL32807

Split units TH with hermetic compressors

Mounting Plate / Screwdriver. Alignment Stickers Screws / Desiccant Bag / Double-sided Tape / Rubber Seal Plug / Rubber Washer

609 West Rock Road, Radford,VA / (fax) RECOMMENDED ATTACHMENTS & CONNECTION DETAILS

LAYING BLOCK AND BRICK

Achat 115MA full-range speaker. user manual

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

Achat 208 HL / 208 HR passive mid-range speaker. user manual

Vision Engravers and Routers PRE-Installation Guide Vision Engraving & Routing Systems

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Tablet Management Rack 16

March 14, Installation of Bay, Bow and Garden Windows

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

Safeguard Waterproofing Systems. Creating useable. living space. by making basements dry

INSTRUCTIONS: LocknCharge Laptop Carts

Bathroom Installation Guide

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Old people and nursing homes. Old people and nursing homes, rehab/medical. SPECIAL SOLUTIONS. Security and comfort for every stage of life.

Step by Step instructions How to screw in wood and plastic

172 Holesaws Overview Bosch Accessories for Power Tools 09/ Diamond holesaw. with Power-Change adapter. 190 Diamond drill bits

Steel Door Frame Installation in Steel Stud Construction

Number Wheeler P/N Description Set Rex P/N Notes Base 1 J Support, Right 1 J Support, Left 1 J Nut (M8)

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Number Wheeler P/N Description Set Rex P/N Notes

Installation GUIDE IMPORTANT: KEEP THIS MANUAL AND THE PRODUCT ID LABEL IN A SAFE PLACE

Please also see 10 golden rules for correct Saniflo installation on

16/32 Channel 1U Rack Mount CCTV Power Supply

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

SAN25 ( <00>)

Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions

Building Regulations P.4. Socket Outlets P.6. Other Considerations P.10. Training Seminars P.24

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

AL-System 6 AQUALOOP System 6. Installation and operating instructions WATER IS OUR ELEMENT.

Electrical Practices for Construction Work

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Electricity to your property

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Model Owner s Manual. Español - P. 19 Français - P. 39

Repair and Renew Grant. Croydon RRG Scheme

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Residential Inspection Guidelines

Detection System Model 3800 Series

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Awning Instructions. Standard Manual 1.5m to 4.5m

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE

2.18 INTERIOR & EXTERIOR FINISHES VAPOR & AIR BARRIERS

Packaged Terminal Air Conditioner Wall Sleeve Installation

Additions and Alterations

Fig B36 Stainless Steel 'T' Type or Basket Type Strainers

Operation manual and Spare parts list EL PUMP. November

Axor ShowerCollection with Philippe Starck Information & inspiration for professionals

Transcription:

Nelson Washbasin Pre-Install Instructions Pre-Install Instructions Please see the below for instructions to prepare site for installation. This product is designed for indoor use in a wet environment, such as a bathroom or washroom. It may only be used in an environment corresponding to the system s IPX6 rating. Ensure that the installation location environment also complies with the following operating parameters: Tempreture - 5 C to 40 C, Relative humidity - 20% to 90% @ 30 C (condensation free), Atmospheric pressure - 700 to 1060 hpa. Ensure a 230 volt (5 amps) fuse spur is installed by means of an approved moisture-resistant wall box (Fig 1.) or by leading an approved cable through the wall for connection outside the room (Fig 2.). The product is supplied with a plug attached, but this will need to be replaced with an IP-rated plug and socket combination appropriate to the location of the socket relative to moisture, or alternatively the product may be hardwired to a mains supply. All electrical connections are to be carried out by a qualified electrician. AC Power to be switched on in advance of OpeMed engineers arrival. All flooring must be level and complete. All walls must be decorated and complete (as per fixing instructions on page 3). Nelson Washbasin 1

Fig. 1 (Recommended) Fig. 2a Fig. 2b 666 (26 2 /8) Fig. 2c 170 (6 6 /8) Hot/Waste/Cold Feed Pipes 75 75 (3) (3) 120 ) (46 /8 340 (13 /8 3 ) 554 160 50 540 290 Fuse Spur 50 100 Fig. 2a Fig. 2c Fig. 2b 2

Fixing Instructions See below for weight limits, fixing recommendations and requirements. The load on each anchor (screw) has been calculated, both for the product sustaining normal load and the product sustaining maximum load. You will find a list of different anchor types and the load they can sustain when fitted into different wall types and suggestions as to how to reinforce a plasterboard wall with plywood. Please note: These suggestions are to be considered as guidelines only. When loaded with Maximum load each anchor supports... When loaded with Maximum load incl. safety factor each anchor supports... Nelson Washbasin 150kg 20kg 225kg 30kg Maximum Load 2 - Wall Anchors Choosing the appropriate anchor for a specific type of wall Wall Type Fischer Type Anchor Type Maximum load Concrete >B25 SX12 Coach Screw 10x80 230 kg Concrete >B25 SX12 Bolt 10x70 230 kg Concrete >B25 1150 kg Solid Brick >= Mz12 SX12 Coach Screw 10x80 75 kg Solid Brick >= Mz12 SX12 Bolt 10x70 75 kg Solid Brick >= Mz12 Solid Sand Lime Brick >= Hlz12 SX12 Coach Screw 10x80 220 kg Solid Sand Lime Brick >= Hlz12 SX12 Bolt 10x70 220 kg Solid Sand Lime Brick >= Hlz12 Hollow Brick >= Hlz12 SX12 Coach Screw 10x80 30 kg Hollow Brick >= Hlz12 SX12 Bolt 10x70 30 kg Hollow Brick >= Hlz12 Aerated Concrete P4 SX12 Coach Screw 10x80 50 kg Aerated Concrete P4 SX12 Bolt 10x70 50 kg Aerated Concrete P4 GB14 M10x105 90 kg Aerated Concrete P4 60 kg 3

Wall Anchors Continued... Hollow Sand Lime Brick >=KSL12 Hollow Sand Lime Brick >=KSL12 SX12 Coach Screw 10x80 40 kg SX12 Bolt 10x70 40 kg Plasterboard (2 x 12,5 mm) KD8 Toggle 39 kg Plasterboard (2 x 12,5 mm) water-resistant KD8 Toggle 58 kg Plasterboard (1 x 12,5 mm) re-enforced with 22 mm plywood KD8 Toggle 133 kg Plywood 22 mm KD8 Toggle 133 kg Chipboard 19 mm KD8 Toggle 86 kg Maximum Load 3 - Check List Recommended load if wall is built in compliance with national standards The OpeMed Nelson Washbasin is compatible with: Brick walls (solid brick or hollow brick) >Mz12 or >Hlz12 2 x1.5 studs, 22 mm plywood or equivalent 2x 12.5 mm plasterboard or equivalent Aerated concrete walls > G2 Concrete walls > B15 4

Maximum Load - 4 - Reinforcements Reinforcements of walls should always comply with national standards Plasterboard 12,5 mm (x2) (water-resistant) Plywood 22 mm (x 2) Please refer to mounting instructions for indication of the placement in height of plywood plate. Plasterboard 12,5 mm (x2) Product Plywood 22 mm (x 2 so that tip of anchor is not exposed) Hollow between walls Screw to fit wall type (see page 2) Plasterboard (other side) Washer 5