LITEWALL Point Fixed Glass Facades

Similar documents
SCHOTT PYRANOVA Planline System

Heat-treated Glass. GUARDIAN A Company of Vision PATTERNED GLASS HORTICULTURAL GLASS SUN PERFORMANCE GLASS VISION GLASS SILKSCREENED GLASS THIN GLASS

IMPORTANT NOTE Technical data and contents may

Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems

The Warm Edge for insulating glass

PYROSWISS VETROFLAM CONTRAFLAM

7. Installation. installation CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME

Glass partitions SFB 3074

Fire Resistant Systems

TOPLIGHTS. NOTE: 2.4m high sliding doors are only available in certain configurations and sizes.

CDW Systems Ltd Contemporary Doors & Windows

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope

Unbeatable energy efficient glass curtain wall system

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

CATALOGO PRODOTTI PORTONI INDUSTRIALI COIBENTATI

EN Insulating glass units, intended to be used in buildings and construction works

Double Glazing Glass. Energy Saving Solutions. Harris Silicones & Glass (Pvt.) Ltd.

Energy Efficient Windows

The Ultimate in Weathersealing Versatility. Dow Corning 123 Silicone Seal

REPORT ON THE TESTING OF SEALED UNITS TO VERIFY THE IMPACT OF PRESSURE EQUALISATION ON INSULATION VALUES.

Installation Detailed installation instructions are provided which should be strictly followed.

SL30-ISO PROFILE SYSTEM

FIRE RATED GLAZING System Guide

PROPOSED SPECIFICATION FOR ALUCOBOND PLUS Aluminium Composite Panel Cladding System Fixed Watertight Cassette Panel System - 4mm thick

Pilkington Activ. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories.

Windows, French doors, folding windows, terrace doors SFB 1074 with low U-values

Pilkington Activ self-cleaning glass. The clear choice for your conservatory.

The answer. Cost-Benefit Ratio of different construction depths. Comparison of U f -values. profine GmbH Kömmerling Kunststoffe

Fall Protection Solutions

Rockwool Cladding Roll

Confort 26. Sliding Systems. Sapa Building System

INFORMATION REGARDING GLASS TYPES AND PROPERTIES

Linear thermal transmittance of the assembly of the glazing and the frame in windows

WINDOWS THE HEAT TRANSFER COEFFICIENT IN DIFFERENT TYPES OF WINDOWS

Self-Cleaning. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories.

ENERGY EFFICIENT WINDOWS & DOORS A GUIDE TO THERMAL PERFORMANCE. Building Solutions Automotive Industry

ATL Fuel Level Sender Probes

Pilkington Activ self-cleaning glass. The clear choice for your conservatory.

REHAU TOTAL70 WINDOW AND DOOR SYSTEM SYSTEM DESCRIPTION. Building Solutions Automotive Industry

TECHNICAL BULLETIN TECHNICAL DESCRIPTION DESCRIPTION OVERVIEW PROGRAMS. Data Sheet. Pilkington Toughened Safety Glass

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

Composite Panel Firewall Systems

BYG DTU. Thermal properties of window frame Type 1 Sheet: 1. Type: Side, top and bottom profile. Source file: Format: dwg/dxf bmp

Specification Guide. SmartSash. Fenestration Solutions for Public Sector & Commercial Applications ARCHITECTURAL. D11 +D13:X725 CI/SfB (31.4)+(31.

Pilkington Reflite Handling and Processing Guidelines Solar Control

Aluminium systems profile selection

PTFE Slide Bearings 04/10 149

Concepts. Products. Service. Glass partitions Lindner Life

Initial Type Testing Report

Suitable for large-area facades, commercial properties, conservatories, extensions plus detached, semi-detached and terraced houses.

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

Rooflighting and Glazing

Improving thermal insulation of concrete sandwich panel buildings

SOLAR SOLUTIONS BONDED MOUNTING TECHNOLOGY. DURABLE BONDING OF PV MODULES TO MOUNTING SYSTEMS WITH Sikasil

PART 1 GENERAL 1.1 SECTION INCLUDES

MOCK-UP TEST REPORT. Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up

The BASA Guide to the ISO Classification of Sealants for Building Construction

Drain Back systems Made in Germany

Innovation Beyond Double Glazing

STEP-BY-STEP. construction guide. Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet.

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

RAICO Bautechnik GmbH. Volker Massmann Area Sales Manager Copenhagen,

Light Architecture. Colors Sweden. Light

FederalDemocratic RepublicofEthiopia

Assessing Curtain Walls

WATER LEAKAGE IN GLAZED CURTAIN WALL SYSTEMS:

Barewood Octagon and Elongated Windows Installation Instructions

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

majestic install ation guide barcelona three sided enclosure 24mm surface mounted wall channels and underframe to base


A Complete Solution CREATING WALLS THAT DEFINE SPACE

Rockwool Flexi Insulation Application Guide

Module 3.7. Thermal bridging

Relieve the pressure with PYRAN S

Evidence of Performance. Class 2. Class 5A. Class C4 / B4. Test Report No PR01. ift Rosenheim

comar1,3,4 & 8 Ground Floor Treatment Innovative, integrated aluminium ground floor framing suites.

Installation Window Building In Details

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape

Sliding and Folding Door Fittings Sliding Door Accessories

Test Report No. C829QPEN

Residential Windows, 3 rd edition Corrected index 1

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa

Plaisance 24. Sliding Systems. Sapa Building System

How To Test For An Architectural Test

VDL 53 - Vacuum drying oven for flammable solvents

Photovoltaic on buildings. solarnova Strom aus Licht

High-speed folding doors. F Series

Layher. Protective Systems. More Possibilities. The Scaffolding System. Layher Keder Roof and Keder Hall Instructions for Assembly and Use

SGGMASTERGLASS Contemporary geometric textured glass

Superlight Compact Nano

Prefabricated building PVC vertical sliding window

Integral Shading & Privacy Solutions

Series 456 Commercial Awning Window

TEST REPORT. Report No.: A Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept

Installation Manuals Version n. 01 of 14/06/2013

iku windows the intelligent self cleaning window AUTOMATIC system

Light-Weight Panels. High quality panels.

Tested to BS 6375: Part 1: 1989 and achieved a weathertightness classification of 2000 Pa (Special)

SELECTIVE GLAZING FOR SUN CONTROL

PV Mounting System For Crystalline Solar Module THE POWER OF ASTRONERGY

Transcription:

Distribution and Technical Service for SAINT-GOBAIN-GLASS Unit 55 2495 Davies Ave. Port Coquitlam, BC Phone: 778.285.8530 Fax: 778.285.8520 LITEWALL Point Fixed Glass Facades Vast expanses of frameless, apparently weightless and transparent walls of light can be created using LITEWALL, the complete structural glazing system. LITEWALL blends versatility to a wide variety of subframe connection possibilities steel elbows, steel spiders, or glass fin.

Single-Glazing or Double-Glazing LITEWALL MONO LITEWALL ISO SGG LITEWALL is a patented point-fixed glazing system - designed, engineered and manufactured by Eckelt Glas GmbH in Steyr, Austria. Eckelt Glas is a wholly owned subsidiary of Saint-Gobain Glass the world s largest glass company. Distributed in North America by Greenlite Glass Systems Inc. History: The system has been in service on many prestigious projects throughout the world for over 10 years. It can be found in Shanghai, Bahrain, Seoul, Dubai, Oakland, Anchorage, and across Europe. It has been used by many leading architects and Contractors. It has withstood the most extremes of environmental conditions. It has been used on high towers, large skylights and extensive facades. The system has been acknowledged by both the Austrian and German governments as suitable for national accreditation under the most stringent regulations. Single-Glazing Applications LITEWALL MONO is the point-fixed performance unit of glass and fitting. The system bolt connections are factory pre-mounted onto the thermally toughened glass under controlled conditions. The units can be installed vertically or to a maximum angle of 10 to the vertical. For barrier-loadings or designed-in structural stiffening of the sub-construction it is necessary to apply for construction permission from Building Control. Max. Dimensions The system has possible maximum dimensions of 2800 x 6000mm (110 x 236 inches). This is possible using the latest in European glass manufacturing technology and machinery.

Applications: Back-ventilated facades, external cladding or space-enclosing external glazing. Glass Dimensioning: Individual structural analyses have been determined for the applications as described in the Permit. The number of point-fixings (4 or 6) and the type of connection (fixed or articulated) are differentiated with independent tables. The tables are divided into glass dimensions and positive / negative design wind loads. Basis for the analysis: 1. maximum bending stress giving a Safety Factor of > 2.4 2. maximum allowable deflection in glass of L/100 3. wind suction and pressure loads including forces from the assumption that the fixing points remain stiff and a temperature difference in the steel sub-frame of +30 C Important requirements of the Sub-Frame: 1. The Sub-Frame must be capable of supporting the self-weight of the Glass elements, Wind loads and the resulting loads. 2. The deflection of the sub-frame when the above mentioned loads are applied must not exceed 1/300 of the Facade height 3. Stabilisation of the sub-frame by means of the Glass is not allowed. 4. The connection of the glass units to the sub-frame is to follow the stiff- / loose-connection principle. 5. The design must be carried out ensuring that tolerances can be accommodated Weather sealing: It is possible to use wet sealing or a wet / dry combination of seal. It is important to use a suitable type of silicone. Engineering: The system is engineered using state-of-the-art Finite Element Analysis software. The software, developed by industry-leading professionals has been used on many sophisticated and challenging projects. The engineering is backed by a leading engineering company in Germany. Testing: Component and system testing has been carried out at Eckelt s own testing facility and at independent test institutes. The design principles and engineering are based on this testing. Pull-out, bending and seal testing have been carried out on the point-fixings. Performance of units for every project is tested in association with procedures laid down by Dow Corning. Each project carries a structural performance warranty backed by Dow Corning. Heat-Soak Testing: All glass is 100% Heat-Soak tested to stringent European standards to ensure that no spontaneous breakage results from Nickel Sulphide inclusions. Quality Control: The system is undergoes stringent quality control procedures as part of Eckelt s ISO 9000 Quality Control system. Installation Note: Installation is only to be carried out by experts. Eckelt & Greenlite Glass Systems offer training and or site-supervision for these purposes. Fixed- and sliding support system: The newly developed Eckelt Spider fittings fulfill the technical requirements of the fixed and loose support system. The patented inserts allow tolerances to be easily accommodated and ensure through correct use the performance of fixed, horizontal loose and loose support connections.

Recommended fixing locations (view from inside): Double Glazed Thermal LITEWALL LITEWALL ISO is a point-fixed insulating glass with ideal system separation between mechanical safety and thermal insulation. The patented glass connection characterises an uninterrupted outer surface with integrated safety against collapse. Applications For filigree glass facades, roofs and entrances

Design The system separation facilitates the non-drilled outer sheet to be designed with energy- or solarinsulating coatings as well as optional Seralit-LITEX screen-printing. Standard composition (variable with design) Outer sheet: 8 mm SECURIT tempered safety glass, coated Cavity: 12 mm air filled with thermal bridge Inner sheet: 14 mm STADIP laminated safety glass comprising: - 6 mm SECURIT tempered safety glass - 0,76 mm pvb - 8 mm SECURIT tempered safety glass Swisspacer-V (SS-V) in colour black is used as the standard cavity spacer bar providing improved thermal-insulation (U-Value) of 0,2 W/m2K when compared to conventional aluminium spacer bars (refer to LITEWALL-ISO TECHNOLOGY) The carrying inner sheet is laminated safety glass comprising two sheets of tempered safety glass and a highly tear-resistant pvb interlayer. Safety concept Wind pressure and suction loads aswell as the self-weight of the unit are transferred to the inner sheet via the structural silicone edge seal. The outer sheet of tempered safety glass has four mechanical restraint clips which connect it to the inner sheet. The restraining clips act as a mechanical restraint should the structural silicone seal ever fail. The clips are designed to hold the glass until structural overloading, Should this ever occur the tempered outer sheet will shatter typically into particles. Requirements of the Sub-Frame: 1. The Sub-Frame must be capable of supporting the self-weight of the Glass elements, Wind loads and the resulting loads. 2. The deflection of the sub-frame when the above mentioned loads are applied must not exceed 1/300 of the Facade height. 3. Stabilisation of the sub-frame by means of the Glass is not allowed. 4. The design must be carried out ensuring that tolerances can be accommodated Installation: is only to be carried out by experts. ECKELT offers training and/or site-supervision for these purposes. Thermal Insulation: Improvement using Swisspacer (SS-V). Conventional U-values of glazing are normally considered without influences of the warm edge condition of the glass element and frame. In order to document an improvement in the thermal insulation performance of a facade it is necessary to take the facade construction into account. An actual evaluation of our system is possible through EN ISO 10077 (provisional version 1999). This allows evaluation of the improvement of the energy transmission value of the facade (Uw-Value) using Swisspacer V in comparison to conventional aluminium spacer bars: Uv-Glass in W/m2K spacer bar aluminium spacer bar Swisspacer 1,6 2,1 1,9 0,2 Improvement in W/m2K