Data Sheet KTV2-8. Bearings Shielded ball bearings, maintenance-free

Similar documents
KTZ data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

Series description: Wilo-Drain TC 40

Submersible pumps Grundfos With top exit Mop sump pomps Simer en City With top exit Submersible pumps Homa Submersible pumps DAB

PS1800 Centrifugal Pumping Systems

Tsurumi BER. Submersible Ejectors

4" SUBMERSIBLE PUMPS

Bælte-lifte Crawlerlifts

The CLIPPER Solutions

Flygt 3068, 50Hz. Technical Specification

EVAC ONLINEVAC TECHNICAL DATA EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

GENERATOR SELECTION. a. Three phase - 120/208V, 3 phase, 4W wye; 277/408, 3 phase, 4W wye; * 120/240V 3 phase, 4W Delta

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

Flygt N-Pumps 3085, 3102 & For reliable and efficient wastewater handling

WANJET. Sprayers. Wanjet sprayers has been produced since 1978.

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Welcome to Grindex Pump handbook! With this handbook we want to share some of our wide experience in pumping with submersible pumps.

Technical data. Danfoss DHP-A

48 SERIES Relay interface modules 10 A

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

18. CARGO TROLLEYS, LIFTING TABLES, HYDRAULIC TABLE TRUCKS, HAND TROLLEYS

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Hydraulic Control Solutions

ELECTRIC PERISTALTIC MORTAR POINTING PUMP

49 Series - Relay interface modules A. Features

SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere.

MH 3M & 4M. High pressure washers with hot benefits

32/1/ /PVSE(Part-II) Ministry of New and Renewable Energy SPV Off Grid Division

M{ZD{ CX-5 z z MME_CX-5_COVER_14R1_V1.indd 1 23/04/ :04:59

MOBILE WATER TREATMENT FACILITY UMUV 01

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

Pure Efficiency. C.C.I.A.A.: N REA Cod. Fiscale e P. IVA: Capitale Sociale versato ,00

38 Series - Relay interface modules A

REGOLATORE ELETTRONICO DI FLUSSO ELECTRONIC PRESS CONTROL CARATTERISTICHE TECNICHE: TECHNICAL CARACHTERISTICS:

lifting stations motralec

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

The conditions below apply to the curves shown on the following pages.

ZF W325 Vertical offset, direct mount marine transmission.

MAGNETIC DRIVE PUMPS M35 TO M200 RANGE

Nilfisk-ALTO NEPTUNE 3 WHY COMPROMISE. Superior hot water technology and performance

EFC Frequency converters

Potential of Steam Energy in PV-Hybrid Systems. Prof. Dr.-Ing. Klaus Brinkmann

38 Series - Relay interface modules A

SIGMA GROUP a. s. Divize průmyslová čerpadla

Vacuum drying oven for non-flammable solvents

CONTENTS: 1. OVERVIEW OF SUMP,SUBMERSIBLE AND BILGE PUMPS 2 2. UNDERSTAND THE PUMP SERVICE DUTY,CONDITIONS AND ENVIRONMENT. 3

Max. Head (m) LVR V , Hz ~ 220 V Oval Flange G1. LVR V , Hz ~ 380 V Oval Flange G1

ZF W320 Vertical offset, direct mount marine transmission.

PART 1 - INTRODUCTION...

ROBOT PUMPS RT - TURBOTEX PUMPS

400W AUTOMATIC STAINLESS STEEL SUBMERSIBLE CLEAN WATER PUMP

Unico Inverter. Unique and efficient.

BASIS RANGE TMB SERIES

ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application

80 Series - Modular timers 16 A. Features

Highly flexible couplings

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

T U R B I N E G A S M E T E R

Series description: Wilo-Yonos MAXO

Servo drives. Compact converter IndraDrive Cs

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors

TECHNICAL SPECIFICATION TYPE ATESO ALFA

Reasons for reissue of this instruction sheet are provided in Section 5, REVISION SUMMARY.

L_PTL12_C01_E_P_TOKIOK_L_PTL12_C01_E_P_TOKIOK :50 Seite 17. Leonard Hausgeräte 2012 Leonard domestic appliances 2012

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Series description: Wilo-Yonos MAXO-D

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Flygt flexible cables

Solid Oxide Fuel Cell Development at Topsoe Fuel Cell A/S

2.24. Pump Controller 704. Data Sheet

HERZ-Thermal Actuators

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

Half the cost Half the carbon

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch

SPY-BATT Battery Tutor Device Installation Manual Rev /04/2016

Aerona Air Source Heat Pumps

Compact pumps from the wastewater experts. FLYGT 3045, 3057, Power range kw.

Product Family of Capacitor Chargers PS-17XX for 1500J/Sec in the range 500Vac to 1,000Vac PS-22XX for 2200J/Sec in the range 500Vac to 1,000Vac

Basic Parameters for Concrete Drilling and Sawing equipment

Standard offering (pumps)

80 Series - Modular timers 16 A. Features

Rotary screw compressors kw 5,5 7, , bar MODULO

Sheet 5:Chapter 5 5 1C Name four physical quantities that are conserved and two quantities that are not conserved during a process.

Series TMM Axial Piston Motor. Technical Information

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

AIR-CONDITIONER SPLIT TYPE

On the Influence of Stator Slot shape on the Energy Conservation Associated with the Submersible Induction Motors

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

CHEMICAL CLEANING UNIT Product number:

( ) = ( ) = {,,, } β ( ), < 1 ( ) + ( ) = ( ) + ( )

Copa Raked Bar Screen

EDS KV TRIPLEX CABLE

APPLICATIONS FOR MOTOR CURRENT SIGNATURE ANALYSIS

Pure Performance. Steady 1300 Series

Transcription:

Data Sheet KTV2-8 200 155 200 o 50 65 353 281 369 KTV2-8 Depth of submersion max. 20m Max. solid handling 6 Power input: 1,10kW Power output: 0,75kW Nominal current: 1,8A Start current: 9,0A 10m HO7RN-F 4Cx1,5 2 carbon on ceramic 2 (50) hose coupling Urethane rubber SUS420J2 (EN-X30Cr13) 11,5 kg (dry weight of the pump without cable) 3.03.2005

Data Sheet KTV2-15 240 187 o 50 80 392 310 396 240 M.W. KTV2-15 Max. solid handling 8,5 Direct on line Power input: 1,87kW Power output: 1,50kW Nominal current: 3,3A Start current: 19,0A 20m HO7RN-F 4Cx1,5 2 2 (50) hose coupling 19,5 kg (dry weight of the pump without cable)

Data Sheet KTV2-22 240 187 o 50 80 412 330 416 240 KTV2-22 Max. solid handling 8,5 Power input: 2,72kW Power output: 2,20kW Nominal current: 4,3A Start current: 30,0A 20m HO7RN-F 4Cx1,5 2 2 (50) hose coupling 23,0 kg (dry weight of the pump without cable)

Data Sheet KTV2-37 285 211 285 o 80 90 387 510 477 KTV2-37 Max. solid handling 8,5 Power input: 4,64kW Power output: 3,70kW Nominal current: 7,4A Start current: 48,0A 20m HO7RN-F 4Cx1,5 2 3 (80) hose coupling 35 kg (dry weight of the pump without cable) 11.01.2006

Data Sheet KTV2-37H 285 211 285 o 50 90 510 387 477 KTV2-37H Max. solid handling 8,5 Dry-type submersible induction motor Power input: 4,64kW Power output: 3,70kW Nominal current: 7,4A Start current: 48,0A 20m HO7RN-F 4Cx1,5 2 2 (50) hose coupling 35 kg (dry weight of the pump without cable)

Data Sheet KTV2-55 300 229 300 o 80 90 422 545 545 KTV2-55 Max. solid handling 8,5 Dry-type submersible induction motor Power input: 7,47kW Power output: 5,50kW Nominal current: 9,7A Start current: 65,0A 20m H07RN-F 4Cx2,5 2 3 (80) hose coupling 46,5 kg (dry weight of the pump without cable)