Imaging for Security Inspection Ed Morton

Similar documents
Cargo Container X-ray Inspection Systems

Experimental study of beam hardening artefacts in photon counting breast computed tomography

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington

Purchasing a cardiac CT scanner: What the radiologist needs to know

T(CR)3IC Testbed for Coherent Radio Cherenkov Radiation from Cosmic-Ray Induced Cascades

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

Chapter 3 SYSTEM SCANNING HARDWARE OVERVIEW

Fundamentals of Cone-Beam CT Imaging

Neutron Detection Setups proposed for

Electron-Muon Ranger (EMR)

Proton tracking for medical imaging and dosimetry

Development of the electromagnetic calorimeter waveform digitizers for the Fermilab Muon g-2 experiment

Towards large dynamic range beam diagnostics and beam dynamics studies. Pavel Evtushenko

Indirect X-ray photon counting image sensor with 27T pixels and 15 electrons RMS accurate threshold

Comparing Digital and Analogue X-ray Inspection for BGA, Flip Chip and CSP Analysis

Truly digital PET imaging

Instruction Sheet

Truly digital PET imaging

CT for the production floor: Recent developments in Hard- and Software for industrial CT Systems

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Silicon Lab Bonn. Physikalisches Institut Universität Bonn. DEPFET Test System Test DESY

ATLAS Tile Calorimeter Readout Electronics Upgrade Program for the High Luminosity LHC

Remote RadEye Product Family

Note monitors controlled by analog signals CRT monitors are controlled by analog voltage. i. e. the level of analog signal delivered through the

Synthetic Sensing: Proximity / Distance Sensors

CHAPTER 5 QC Test For Radiographic Equipment. Prepared by:- Kamarul Amin bin Abu Bakar School of Medical Imaging KLMUC

Reconfigurable System-on-Chip Design

Basler. Line Scan Cameras

CMS Tracker module / hybrid tests and DAQ development for the HL-LHC

CT scanning. By Mikael Jensen & Jens E. Wilhjelm Risø National laboratory Ørsted DTU. (Ver /9/07) by M. Jensen and J. E.

Development of on line monitor detectors used for clinical routine in proton and ion therapy

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950

U1602A Handheld Oscilloscopes, 20 MHz

Description: Multiparameter System (4 or 8 channels)

AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE

Radiation Detection and Measurement

X- and Gamma Ray Imaging Systems based on CdTe-CMOS Detector Technology

(Amplifying) Photo Detectors: Avalanche Photodiodes Silicon Photomultiplier

Electron-Muon Ranger (EMR)


MRC High Resolution. MR-compatible digital HD video camera. User manual

Applications: X-ray Microtomography, Streak Tube and CRT Readout, Industrial & Medical Imaging X-RAY GROUP

Performance Comparison of Four Commercial GE Discovery PET/CT Scanners: A Monte Carlo Study Using GATE

HI-SCAN T-2is. Hermetically sealed oil bath l single tank

MH - Gesellschaft für Hardware/Software mbh

Precision Tracking Test Beams at the DESY-II Synchrotron. Simon Spannagel DPG 2014 T88.7 Mainz,

Video eavesdropping- RF

Fiber Optic Distributed Temperature Sensor (B-DTS)

Advanced variance reduction techniques applied to Monte Carlo simulation of linacs

Information about the T9 beam line and experimental facilities

Feasibility Study of Neutron Dose for Real Time Image Guided. Proton Therapy: A Monte Carlo Study

CAPTAN: A Hardware Architecture for Integrated Data Acquisition, Control, and Analysis for Detector Development

Silicon Seminar. Optolinks and Off Detector Electronics in ATLAS Pixel Detector

Design and Test of Fast Laser Driver Circuits

Chapter 8. Low energy ion scattering study of Fe 4 N on Cu(100)

Testing thermo-acoustic sound generation in water with proton and laser beams

Lucien Antonissen Key Account Manager LIOS Technology Germany

Rb 82 Cardiac PET Scanning Protocols and Dosimetry. Deborah Tout Nuclear Medicine Department Central Manchester University Hospitals

Data. microcat +SPECT

Tom Wilson Product Marketing Manager Delivery Systems Varian Medical Systems International AG. CERN Accelerator School, May 2015

The data acquisition system of the XMASS experiment

Page: 1 of 6 Page: 1 of 6

GAMMA-RAY SPECTRA REFERENCES

product overview pco.edge family the most versatile scmos camera portfolio on the market pioneer in scmos image sensor technology

NEW PRODUCT ANNOUCEMENT

Evaluation Tools for the Performance of a NESTOR Test Detector

Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies

Below is a diagram explaining the data packet and the timing related to the mouse clock while receiving a byte from the PS-2 mouse:

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL

AxioCam MR The All-round Camera for Biology, Medicine and Materials Analysis Digital Documentation in Microscopy

X-RAY IMAGING Emerging Digital Technology - CMOS Detectors

A PHOTOGRAMMETRIC APPRAOCH FOR AUTOMATIC TRAFFIC ASSESSMENT USING CONVENTIONAL CCTV CAMERA

ISTITUTO NAZIONALE DI FISICA NUCLEARE

Digital vs. Analogue Control Systems

Measuring Temperature withthermistors a Tutorial David Potter

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Clinical Photon Beams

Cone Beam Reconstruction Jiang Hsieh, Ph.D.

SPADIC: CBM TRD Readout ASIC

Product Data Sheets. Belt Conveyor System

Experiment 5. Lasers and laser mode structure

Digital Magnetometer Systems - DM Series

RFSPACE CLOUD-IQ #CONNECTED SOFTWARE DEFINED RADIO

Carlo Canziani Business Development EMEA Agilent Technologies

ON-LINE MONITORING OF AN HADRON BEAM FOR RADIOTHERAPEUTIC TREATMENTS

Variance reduction techniques used in BEAMnrc

MICE detectors and first results. M. Bonesini Sezione INFN Milano Bicocca

Pixie Viewer Online Help

AN INVESTIGATION INTO THE USEFULNESS OF THE ISOCS MATHEMATICAL EFFICIENCY CALIBRATION FOR LARGE RECTANGULAR 3 x5 x16 NAI DETECTORS

HEAVY WATER LEAK DETECTOR

New Inspection Systems Based on the Registration of the Backscattered X-rays

Development. Igor Sheviakov Manfred Zimmer Peter Göttlicher Qingqing Xia. AGIPD Meeting April, 2014

École Supérieure d'optique

Cooking at the Speed of light!

Gamma-ray Large Area Space Telescope (GLAST) Large Area Telescope (LAT) Calorimeter AFEE Board Parts Radiation Test Plan

Industrial X-ray for Nondestructive Testing Unrestricted Siemens AG All rights reserved

Transcription:

Imaging for Security Inspection Ed Morton

Overview 2 Low Energy Detectors Checkpoint X-Ray Occupied Vehicle High Speed Computed Tomography High Energy Detectors Standard Speed High Speed Reverse Geometry Imaging 2D Imaging 3D Imaging

Basic Physics

X-Ray Generation At low energies, X-ray production is almost isotropic Electron on Target At high energies, X-ray production is much more forward directed 4

5 X-Ray Spectra Low Energy

X-Ray Spectra High Energy Area of interest for NII 6

Material Attenuation High Energy Low Energy 7

Low energy X-Ray imaging systems

Checkpoint Inspection System Geometry X-ray detectors End View Conveyor X-Ray Source Performance measured in terms of Spatial resolution Steel penetration Material discrimination 9

Dual Energy Imaging Incident X-Rays Low Energy Detector (LE) LE HE Optional Filter High Energy Detector (HE) 10

Dual Energy Imaging HE - LE HE + LE 11

Scintillation Based Detectors 0.8 2.5mm pitch Charge integrating ADC (20 bit) Serial readout at 40MHz Maximum frame rate 500 Hz 12

13 HMEs and Benign Materials in ρ-zeff Space

14 Effect of Clutter in Bags

Example Images Automatic Identification - Explosives - Narcotics - LAGs 15

Semiconductor Based Detectors CdTe detector array 0.8mm pixel pitch Dual view with horizontal and vertical beams Detectors manufactured by MultiX Detection (64 energy bins) Alternative detectors manufactured by Kromek (5 energy bins) 160kV X-ray generators ~ 5 Mcps/mm2 16

Example Images CsI CdTe 17

Scintillator or Semiconductor? Scintillator Cost effective Image lag -> blurred images Good detection efficiency Large installed base Algorithm performance: Approved Semiconductor Expensive Sharp images Good detection efficiency No field reliability data Algorithm performance: To be approved, lower Pfa 18

Occupied Vehicle System Geometry 200kV X-ray source Tube current dependent on vehicle speed Data acquisition rate dependent on vehicle speed 2.5mm to 5.6mm detector pitch in linear array CdWO4 scintillators with low capacitance (20 50 pf) diode 19

Data Acquisition System Architecture DAB DAB Diode Array Board (DAB) DAB x16 Concentrator Card Ethernet 100Base-T DAB DAB Sync Network Switch DAB DAB x16 Concentrator Card Ethernet 100Base-T Ethernet 1000Base-T Array PC DAB More concentrator cards as needed TCP/IP Ethernet to Control PC 20

Scintillation Based Detectors 20-bit charge integrating ADC on detector boards Data propagated to DAQ via dedicated serial link DAQ supports 16 detector boards, outputs 100Base-T Ethernet (UDP format). Use cascaded Sync to create arbitrary array length Detector Inputs Sync Out Sync In Ethernet In-system programming of all programmable components Helps to manage single event upsets caused by radiation interactions 21

Example Image 200kV X-ray Source Drive through speed 10 km/h typical Spatial resolution 4 mm 22 Typical driver dose < 0.25 usv. Equivalent to approximately 3 minutes flight time at normal cruising altitude.

Real Time Tomography System Geometry Conventional CT Ring of X- ray sensors RTT 23 Conveyor Belt Ring of X-ray sources

Real Time Tomography System Geometry Multi-focus X-ray tube surrounds baggage conveyor belt. Electronic switching provides illusion of motion without actual physical movement 24

Scintillation Based Detectors 16-bit charge integrating ADCs Format data into 1.2Gbps data transmission protocol: HD video 720p 8 x 16 pixel array format 100-200us signal integration time 160kV X-ray source LYSO scintillator Liquid cooled for high system stability 25

26 Example Images

High Energy X-Ray Imaging Systems

System Geometry X-Ray Pulses Operator Workstation 28

Dual Energy Imaging Detector Linac 6MV 4MV - 6MV 4MV Dual Energy HE - LE HE - LE HE + LE 29

Dual Energy Imaging Mean LUT counts σ Signal 30

Scintillation Based Detectors CdWO4: 5 x 5 x 30 mm sensitive detector element Arrays of 8 x 1 elements per module, 16 x 1 elements per board. Typically 70+ modules per system = 1100 detector channels Charge integrating ADC with 20-bit resolution Same serial readout and data acquisition system as discussed previously Typical 400 Hz maximum pulse rate (limited by Linac magnetron) 31

32 Material Separation Capability

33 Material Separation Capability

High Speed Imaging Fan Beam Cone Beam LE HE LE HE LE HE LE HE 34

35 Scintillation Based Detectors

36 Eagle R60HS Full Scan

Eagle R60HS Image Container Full of Household Goods 37

Reverse Geometry Imaging

39 X-Ray Compton Backscatter Geometry

Scintillation Based Detectors 1000mm x 300mm x 20mm plastic scintillator MCA based detector electronics synchronised to collimator position 40

Scintillation Based Detectors Monte Carlo model (Geant4) of Compton X-ray scattering into detector panels Use weighting factors to minimise impact of natural background which will otherwise reduce SNR 41

Rapiscan RXU Imaging Gun and plastic explosive attached to underside of chassis. Gun and hand grenade placed in spare-wheel compartment underneath High-density plastic sheet for contrast. 42 Rapiscan Reflexion Product line is not available for sale or use in certain countries. Please check with your Sales Manager as to eligibility for sale

Rapiscan RXM / RXV Imaging 43 Rapiscan Reflexion Product line is not available for sale or use in certain countries. Please check with your Sales Manager as to eligibility for sale

3D Time-of-Flight Backscatter Geometry STFC Daresbury VELA Source 4.7MeV, 100pC bunch charge, 4 ps pulse width 3 diameter CeBr3 detector (Scionix) 44

Scintillation Based Detectors Digital pulse shape processing to deal with pulse pileup. 4GS/s sample rate (digital oscilloscope) with 7ns measured rise time 45

Feasibility Study Results Simultaneous scattering from three separate (nylon) test objects Photons of all energies included Single scatter object at two different locations Lowest energy photons rejected to reduce scatter background 46

Next Steps Array of 50mm x 50mm x 50mm plastic scintillator detectors with fast PMT (ET 9821KB) 2GB/s digitisers with simultaneous sampling on all channels Expect 300ps time resolution (equivalent to 10cm spatial resolution) Develop reconstruction algorithms for 3D imaging of large objects Next data collection planned at Daresbury Lab VELA facility autumn 2014. Consortium partners: UCL, STFC, Liverpool, Rapiscan 47

Imaging for Security Inspection