Headstone Installation Standard

Similar documents
THE BLUE BOOK. British Register of Accredited Memorial Masons. Truly Independent

TASMAN DISTRICT COUNCIL CEMETERY

SECTION GUARDA SECURITY WINDOW SCREENS

How to build a Pizza Oven in 4 days

CLEAR-DIVISIONS CENTERFOLD

CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION

Minor Cracks in Horizontal Surfaces

1.02 DESCRIPTION A. This Section specifies furnishing and installing Cast in Place Detectable/Tactile Warning Surface tiles where indicated.

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

If stepping is required, step at 180mm as seen in this picture.

CLEAR-DIVISIONS VARIOFOLD

Profiles for floors of same height Cerfix Projoint

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

ITS specification Jointing chambers and pull pits (ITS-02-02)

Linkeo 19" freestanding cabinets

K2 STONE NATURAL VENEER

Technical Information

Chapter 36 - STRAW BALE CONSTRUCTION SECTION PURPOSE. SECTION SCOPE. SECTION DEFINITIONS.

DRY CLEANING PAPER DOCUMENTS

City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures

CLEAR-DIVISIONS APERTO

Hanson Building Products. precast basement solutions

How to build raised beds page

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

How To Retaining Wall Guide

Laying the First Course. 1. Excavate the site and construct the footing.

INSTALLATION. General. Important Note. Design. Transport

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

FLASHMAN WINDOW AND DOOR FLASHING SYSTEM. Product. Scope. Appraisal No. 573 [2013]

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render

The Difference Between Cast Stone and Adhered Manufactured Stone Masonry Veneer

Installation Instructions

Technical handbook Panel Anchoring System

MEMORIALS OF DISTINCTION

September 1, 2003 CONCRETE MANUAL CONCRETE PAVEMENT REHABILITATION

CITY OF SELMA, TEXAS Inspection Checklist: Commercial

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

White rust on galvanized and galvanized pre-painted steel. Technical Information

AA Solar and Sun Power Plus

8.7 Schluter -KERDI-LINE

TECHNICAL SPECIFICATIONS CONCRETE SIDEWALKS, DRIVEWAYS AND CURB AND GUTTER

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

Saferand easierinstallation

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

LAYING BLOCK AND BRICK

CEEN Geotechnical Engineering Laboratory Session 7 - Direct Shear and Unconfined Compression Tests

RAW INSTALLATION GUIDE

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

PROJECT TITLE : 2-STOREY RESIDENCE LOCATION : ALONG DAANG HARI,MOLINO.BACOOR,CAVITE OWNER : CUEVASVILLE REALTY

METHOD OF TEST FOR UNIT WEIGHT OF FRESH CONCRETE

BILL OF QUANTITY FOR THE WORK OF "REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP"


OIL SPILL CONTAINMENT CONTAINERS AND RACKING

The Minnesota Lath and Plaster Bureau Repairing Cracks in Stucco

SPECIFICATIONS. INTERLOCKING CONCRETE POROUS PAVING UNITS or Permeable Interlocking Concrete Pavers (PICP)

TopSky DLG Installation Manual

Connex. Mortarless Masonry Block System

Asphalt Shingle Application Requirements

NEGRP TEST SUMMARY. Joseph A. Lanzoni, November 2005

VOLUME AND SURFACE AREAS OF SOLIDS

INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS

Fixed Access Ladders. Table of Contents. 1. Legislative Requirements

CRASH RAIL INSTALLATION HEIGHT

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

Installation System. Existing Resilient Sheet Floors

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

HOUSE BUILDING DIGEST

SC2000 CEMENT BONDING PROCEDURES

Basic Principles & Common Practices

TARIFF CODE and updates standard

Guidelines for Earthquake Bracing of Residential Water Heaters

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

Grand Mesa Plus LAMINATE - WIRE BRUSHED. GAGVGM81012A Prairie. GAGVGM80012NA Colorado. GAGVGM84012A Pecan Rustic. GAGVGM85012A Saddle Walnut

Vinyl Composition Tile Installation System

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

AIRPORT SECURITY FENCING. A. American Society for Testing and Materials (ASTM):

Concrete Repair. Applications and Procedures

SECTION WINDOW WASHING SYSTEMS

Fixed Vertical Access Ladders

Superform Products Ltd.

FLAT ROOF CARPORT RECOMMENDED INSTRUCTION MANUAL

KITCHENS. Tip PAGE 1 FITTING YOUR KITCHEN GUIDE. How to mark out a kitchen. Tools required for installing a kitchen STEP ONE STEP TWO STEP THREE

SECTION GUARDRAILS

GENERAL SPECIFICATION FOR CIVIL ENGINEERING WORKS SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS

Services Enclosures and Protected Shafts - Maintaining Compartmentation

MultiPost-AP anchorage device

MONDOATHENS BASKETBALL SET (Reference PK110)

K17.11 DOOR BOLTS K17 DOORS

Site sampling and testing of concrete

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Selection, Use, and Care of Brushes

METHOD STATEMENT FOR INSTALLATION OF CABLE TRAY/TRUNKING/LADDER

STANDARD SPECIFICATIONS SECTION PRECAST REINFORCED CONCRETE MANHOLES AND MANHOLE BASES. 1. Structure Earthwork: 02200

Chapter. Restoration of Damaged Structures

OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide. GeneralShale.com

Transcription:

Headstone Installation Standard Private Bag 9002 Hastings 4156 207 Lyndon Rd E Tel: 06 871 5000 General Guide for Installation of Memorial The obtaining of a permit from the Sexton for installation of new memorial work is required. This assists with inspection procedures and with the conforming to Council bylaws and regulations. The permit should contain accurate measurements of the memorial work and not measurements that simply fit in with permitted limits. Checks will be made by the sexton and where memorial work has been installed that exceeds the stipulated limits of height, width, etc the memorial work will be required to be removed forthwith A Notice of Intended Work is required and is to be approved by the Sexton for any additional memorial work being undertaken on an existing memorial Explanation Concrete beam shall mean the beam for setting memorials and bases on Upright headstone shall mean erected vertically on base A base is placed for upright memorials. It may be of plastered concrete, granite or marble. A sub base of plastered concrete is used on sloping or uneven beams for levelling up purposes. The New Zealand Standard 4242: 1995, Headstones and Cemetery Monuments is to apply to all erection of memorial work 1) All structural materials used in the cemetery monument shall exhibit high atmospheric-corrosion resistant properties and have a minimum predicted service life of 50 years 2) All memorial headstones or plaques shall be erected level and plumb in both directions in accordance with standard trade practice. 3) All memorial bases shall line up in adjacent rows horizontally in accordance with the layout 4) Where a concrete base is installed for a memorial it should be poured or set on beam with nib access cut in beam or dowelled to prevent side or end movement, particularly where the beam is laid on a sloping lawn 5) Where a granite or marble base or plinth is installed, it shall be pinned to the beam or to the concrete sub base 6) All upright memorials and bases are to be securely pinned or dowelled to avoid tipping by accident or vandalism. The requirements of the Health and Safety in Employment Act must not be compromised.

7) Dowelling must consist of metal, resistant to atmospheric corrosion, such as copper alloy or stainless steel. Mild steel rod or galvanised rod is not permitted. Refer to NZ Standard 4242: 1995 (Headstones and Cemetery Monuments. Fibre rod described as high tensile FRP rod 12.75mm in diameter is also acceptable 8) For memorials up to 900mm high, dowelling shall be not less than 10mm in diameter and 140mm in length with dowel penetration being of equal part with each structural element. For memorials 900-1200mm in height dowelling shall be not less than 12mm in diameter and not less than 200mm in length 9) All concrete work shall be performed to sound construction practice and consist of not less than 5 parts of clean shingle and sand to 1 part cement. 10) All plaster shall be mixed in the proportions of 1½ -3 parts clean sharp sand to 1 part cement with plasticizer added if desired 11) All plaster shall be applied uniformly and smoothed with a steel or wooden float finish or sponge texture. The finish shall be even with no trowel or float marks visible. 12) All corners and checks shall be properly squared. The joins between memorial and base and base and ground beam shall be washed or wiped clean of surplus plaster residue. Joins shall be finished true and even with memorial and flushed level with ground beam. 13) Where the beam has been constructed for some time it is to be cleaned off before memorial installation and plaster finish is undertaken to promote good adhesion. Standard cleaning methods include wire brush scrubbing, water blasting or chemical cleaning 14) All work sites shall be left clean and tidy and free of surplus construction residue. All construction residue shall be removed from the cemetery grounds.

Illustration Appendix FRONT VIEW Dowels Level Sloping Beam END VIEW Level Dowels Sloping Beam

BACK TO BACK MEMORIALS BASE TO BEAM LAYOUT NOTE: maximum height is 900mm memorial in all areas except in Blocks B & C of Mangaroa Cemetery and Blocks G, H & T of Hastings Cemetery where the maximum height is 1200mm by Special Request Max height 900mm Width 915mm 450mm BURIAL PLOT HEADSTONE DIMENSIONS

NOTE: maximum height is 500mm memorial in all areas Plate width 500mm max Plate Height 400mm max Width 500mm 300mm HAVELOCK NORTH CEMETERY CREMATION PLOT HEADSTONE DIMENSIONS NOTE: maximum height is 600mm memorial in all areas Plate width 600mm max Plate Height 500mm max Width 600mm 250mm HASTINGS CEMETERY CREMATION PLOT HEADSTONE DIMENSIONS