Industrial Bar Code Scanners



Similar documents
Industrial Bar Code Scanners

Industrial Bar Code Scanners

Industrial Bar Code Scanners

DS8100A QUICK REFERENCE GUIDE (Rev. D)

DX6400 QUICK REFERENCE GUIDE (Rev. E)

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

Bar code scanners CLV45x / CLV450 / Standard Density

Barcode Reader Series BCL 31, BCL 32, BCL 34

Set for Profibus DPV1 in IP20 TI-BL20-DPV1-8

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

DS6300 QUICK REFERENCE GUIDE (Rev. J)

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Bar code scanners CLX49x / CLX490 / Standard Density

FACTORY AUTOMATION LASER BARCODE SCANNERS FOR INDUSTRIAL AUTOMATION

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Cable Pinouts. SRP I/O Module

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

TCNM AD/EX Barcode Scanner. Instruction Manual

applicomio Profibus-DP

IntesisBox Modbus Server Fidelio IP

FACTORY AUTOMATION MANUAL VB6-240

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

FACTORY AUTOMATION MANUAL VB6-240-V BARCODE SCANNER

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing

SSI. Modbus Analogue Output DEVICENET ETHERNETIP. Zero Slip, Zero Wear. Exact Measurement. No Moving Parts. Permanently Calibrated.

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

MS2xxx SERIES Stratos PRODUCT GUIDE

IntesisBox KNX Modbus TCP master

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Cable Specifications and Information

VOICE RECORDING SYSTEM ISDN PRI / BRI

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

In-Sight Hardware specifications

3500/22M Transient Data Interface

User manual Compact Web PLC WP240 series IEC-line

Installation Guide. AXIS 2191 Audio Module Sight, Speech and Sound over IP!

Electronic Control Devices The European Product Catalogue 2007

EA7-T8C EA7-T10C EA7-T12C EA7-T15C

Telephone- and leased line modem for industrial applications TD-36

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Soft-Starter SSW-06 V1.6X - Profibus DP, DeviceNet and EtherNet/IP

Connectors and Cables

CLV440/442 Bar Code Scanner

How To Run An Nport I5000A Device Server

DTS/DRS-1000RV. Owner s Manual. DTS-1000RV: DVI/HDMI or VGA, Audio, RS-232C Transmitter Extender

Modbus Server SAMSUNG Air Conditioners

DK40 Datasheet & Hardware manual Version 2

MS9500 SERIES VOYAGER PRODUCT GUIDE. Single Line, Hand-Held, 1D, High-Density 1D, PDF-417 2D and Wireless Laser Bar Code Scanners

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

Rack mounted telephone- and leased line modem for industrial applications

Hardware Manual RM CANview Ethernet

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Matrix 400 QUICK REFERENCE GUIDE

MACHINEMATE. CNC SYSTEM Hardware SPECIFICATION

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

IntesisBox KNX Modbus RTU master

Automatic Transfer Switch-Controller ATS-C by Eaton. Automatic Transfer Switch- Controller ATS-C 96 and C 144

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

RS-232 COMMUNICATIONS

Bar Code CCD Scanner OPERATION MANUAL

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

connecdim Gateway G1 Ethernet TCP/IP to DALI

How To Power A Schen

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Alcalde # 1822 Col. Miraflores C.P Guadalajara, Jal. Mexico MX 01 (33) y USA 001 (619) (San Diego, CA.

Portable BACnet /IP to MS/TP Router

Perle 10/100 Ethernet Media Converters

MechoNet TM Network Interface (MNI) Specification Submittal

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

LwLVision-USB 2.0. Installation Guide

NX safety stand-alone

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

KSH-3000-MI. Swipe Card Reader. ( Magnetic / IC Card two in One Reader ) Revision Reason Date V

ABSOLUTE ROTARY ENCODER ETHERNET/IP

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

ewon COSY 141 Installation Guide

Moxa EtherDevice Switch

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

Contents. SPECIFICATIONS AND FEATURES GUIDE NI Serial Hardware

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite:

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

TPM Product Type 107-D162-NNT 48-channel digital input and 16-channel digital output module with pluggable terminal

MATRIX 210. Host Mode Programming

Electronic Control Devices The European Product Catalogue 2007

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

KNX Panasonic Air Conditioners

Why you need to monitor serial communication?

BridgeWay Fixed Base Radio Telecom VoIP Gateway

Transcription:

DX8200A Industrial Bar Code Scanners Configuration SW Tool ACR4 technology PackTrack ASTRA technology APPLICATIONS Postal/Courier parcel sorting and tracking Automated warehousing identification systems Airport baggage sorting systems Cargo applications Loading/unloading systems ADVANTAGES Improved connectivity thanks to the introduction of built-in Ethernet with implemented TCP-IP, Ethernet/IP and Modbus TCP protocols DIGITECH Digitech technology permits full SW control over signal processing parameters Scanner setup can therefore be optimized quite simply by loading the right SW recipe, thus enabling excellent performance in all reading conditions Ease of use is increased due to a practical display with keyboard, offering a simple and complete human machine interface without PC Fully compatible with the DS8100A, the 6000 series (DS6300, DS6400) and the SC6000 industrial controller www.automation.datalogic.com 70

HIGHLIGHTS Omnidirectional reading ACR4 code reconstruction algorithm ASTRA technology for the electronic focusing system DIGITECH signal processing technology PACKTRACK to minimize the gap between objects and increase system productivity GENIUS multilanguage SW for easy scanner configuration/setup Display and keyboard Display and keyboard Built-in Ethernet TCP/IP connectivity GENERAL DESCRIPTION DX8200A is based on an innovative 3-diode structure that offers an unbeatable real time depth of field. As a result of improved ASTRA technology that increases its already impressive performance, 3 laser diodes are electronically switched from one to the other, depending on the bar code distance from the scanner. This means that the scanner is able to capture the bar code on an object of any possible shape and in any position, since as the DX8200A focuses on the bar code and not on the object profile. The PackTrack function reduces minimum object gap and increases system throughput. The SW platform of DX8200A, based on GENIUS configuration program, permits 100% control of scanner functionality via SW. Moreover, DIGITECH technology enables excellent reading performance along the entire depth of field. 71

DX8200A READING DIAGRAMS (0.25 mm/10 mils) DX8200A-3X2X (0.30 mm/12 mils) DX8200A-3X1X (0.38 mm/15 mils) DX8200A-3X1X (0.50 mm/20 mils) dimensions mm / inch www.automation.datalogic.com 72

Electrical Connections All the connectors available for each DX8200A model are the following: Scanner Model Standard Ethernet Connectors 26-pin male serial interface and I/O connector 17-pin male Lonworks connector* 17-pin female Lonworks connector* 26-pin male serial interface and I/O connector 17-pin male Lonworks connector* 17-pin female Lonworks connector* RJ45 Industrial modular connector The DX8200A Standard and Fieldbus models are equipped with a 26-pin male D-sub connector for connection to the host computer, power supply and input/output signals. 26-pin Connector 26-pin D-sub Connector Pinout Pin Name Function 1 CHASSIS Chassis - internally connected to GND Cable shield connected to chassis 20 RXAUX Receive data of auxiliary RS232 (referred to GND) 21 TXAUX Transmit data of auxiliary RS232 (referred to GND) 8 OUT 1+ Configurable digital output 1 - positive pin 22 OUT 1- Configurable digital output 1 - negative pin 11 OUT 2+ Configurable digital output 2 - positive pin 12 OUT 2- Configurable digital output 2 - negative pin 16 OUT 3A Configurable digital output 3 - polarity insensitive 17 OUT 3B Configurable digital output 3 - polarity insensitive 18 EXT_TRIG/PS A External trigger (polarity insensitive) for PS 19 EXT_TRIG/PS B External trigger (polarity insensitive) for PS 6 IN 2/ENC A Input signal 2 (polarity insensitive) for Encoder 10 IN 2/ENC B Input signal 2 (polarity insensitive) for Encoder 14 IN 3A Input signal 3 (polarity insensitive) 15 IN 4A Input signal 4 (polarity insensitive) 24 IN_REF Common reference of IN3 and IN4 (polarity insensitive) 9,13 VS Supply voltage - positive pin 23,25,26 GND Supply voltage - negative pin Pin RS232 RS232 RS485 Full-Duplex RS485 Half-Duplex 2 TX TX485 + RTX485 + 3 RX RX485 + 4 Main Interface Signals (SW Selectable) RTS TX485 - RTX485-5 CTS RX485-7 GND_ISO GND_ISO GND_ISO 73

DX8200A Electrical Connections Lonworks INPUT/OUTPUT Connectors Lonworks INPUT/OUTPUT 17-pin Connector Pinout Pin Name Function A1 GND supply voltage (negative pin) A2 VS supply voltage 20 to 30 VDC (positive pin) 1 CHASSIS Cable shield A internally connected by capacitor to chassis 3 CHASSIS Cable shield B internally connected by capacitor to chassis 7 VS_I/O Supply voltage of I/O circuit 8 LON A+ Lonworks a line (positive pin) 9 LON A- Lonworks a line (negative pin) 10 LON B+ Lonworks b line (positive pin) 11 LON B- Lonworks b line (negative pin) 12 SYS_I/O System signal 13 SYS_ENC_I/O System signal 14 RES Internally connected 15 REF_I/O Reference voltage of I/O circuit 2,4,5,6 NC Not Connected In DS8100A Ethernet models a RJ45 Modular Jack is provided for Ethernet connection. This interface and the connector pinout are IEEE 802.3 10 BaseT and IEEE 802.3u 100 BaseTX compliant. RJ45 Modular Jack RJ45 modular jack pinout Pin Name Function 1 TX + Transmitted data (+) 2 TX - Transmitted data (-) 3 RX + Received data (+) 6 RX - Received data (-) 4,5,7,8 NC Not connected www.automation.datalogic.com 74

TECHNICAL DATA DIMENSIONS WEIGHT CASE MATERIAL OPERATING TEMPERATURE STORAGE TEMPERATURE HUMIDITY VIBRATION RESISTANCE SHOCK RESISTANCE PROTECTION CLASS LIGHT SOURCE SCANNING SPEED READING PATTERN RESOLUTION READABLE SYMBOLOGIES MULTILABEL READING COMMUNICATION INTERFACES OTHER AVAILABLE INTERFACES DIGITAL INPUTS DIGITAL OUTPUTS DISPLAY & KEYPAD LED INDICATORS DEVICE PROGRAMMING OPERATING MODES LASER CLASSIFICATION LASER CONTROL POWER SUPPLY: POWER CONSUMPTION: 319.5 x 248.7 x 99.7 mm (12.58 x 9.79 x 3.93 in) 3.3 Kg (7.26 lbs) Steel 0 to 50 C (32 to 122 F) -20 to 70 C (-4 to 158 F) 90% non condensing IEC 68-2-6 test FC 1.5mm; 10 to 55 Hz; 2 hours on each axis IEC 68-2-27 test EA 30 G 11 ms; OM: 15 G 11 ms; 3 shocks on each axis IP64 for standard models; IP65 on request Visible laser diode (630 to 680 nm) 1000 scans/s (500 scans per line) Single-cross See diagrams 22 symbologies including 2/5 family, Code39, Code93, Code128, EAN/UPC, EAN128, ISBN128 Up to 10 different symbologies during the same reading phase Main Port: RS232/RS485 up to 115.2 Kbit/s Auxiliary Port: RS232 up to 115.2 Kbit/s Lonworks (Master/Slave), Ethernet, Profibus, DeviceNet (optional) 3 programmable and 1 Encoder (optocoupled); Auxiliary Input, NPN/PNP transistor (optocoupled) Three SW programmable, optocoupled, event driven LCD 16 x 2 characters & 3 keys 6 LED status indicators Windows based SW (Genius ) via serial or Ethernet link Serial Host Mode Programming sequences On-line, Serial On-line, Automatic, Continuous, PackTrack, Test Class 2 - EN60825-1; Class II - CDRH Safety system to turn laser off in cases of motor slowdown or failure 10 to 30 VDC < 10 W 75